Download as xlsx, pdf, or txt
Download as xlsx, pdf, or txt
You are on page 1of 4

Kind of fixtures No.

of fixtures Public/Private
2ND FLOOR Bidet 2 4
Lavatory 2 2
Water Closet (flush) 10 5
Urinal (stall) 4 5
3RD FLOOR Bidet 2 4
Lavatory 2 2
Water Closet (flush) 10 5
Urinal (stall) 4 5
Bar Sink 1 1
Shower 4 4
Sink 2 4
Bathtub 8 4
Lavatory 4 2
4TH FLOOR Bidet 2 4
Lavatory 2 2
Water Closet (flush) 10 5
Urinal (stall) 4 5
Laundry tub 8 4
Bar sink 1 2
5TH-9TH FLOOR Dishwasher Sink 12 2
Water Closet (flush) 12 3
Bathtub 8 2
Shower 12 1
Bidet 12 2
Lavatory 12 1
10TH-11TH FLOOR Lavatory 8 1
Dishwasher Sink 8 2
Water Closet (flush) 8 3
Bathtub 8 2
Shower 8 1
Bidet 8 2
12TH FLOOR Dishwasher Sink 3 2
Bidet 2 4
Lavatory 2 2
Water Closet (flush) 10 5
Urinal (stall) 4 5
TOTAL FIXTURES =

1229 𝐹𝑈 𝑥 (8 𝑔𝑎𝑙𝑙𝑜𝑛𝑠)/(1 𝐹𝑈)=9832 𝑔𝑎𝑙


1229 𝐹𝑈 𝑥 (8 𝑔𝑎𝑙𝑙𝑜𝑛𝑠)/(1 𝐹𝑈)=9832 𝑔𝑎𝑙

9832 𝑔𝑎𝑙 𝑥 (3.7854 𝐿)/(1 𝑔𝑎𝑙) x 〖 1� 〗 ^3/1000𝐿= 〖�� .𝟐𝟐� 〗 ^�

�= 𝜋/4 𝑑^2

where:
h = 2m d = 4.87m
h = 2.5m d = 4.35m
h = 3m d = 3.97m
h = 3.5m d = 3.68m

Through "Demand Load" graph, demand (L/s) is obtained.


: Therefore the diameter of pipe per floor is 25.4mm or 1in. > 3/4 𝑖𝑛

: Therefore the diameter of the main pipe is 25.4mm or 1in.


Total Demand (L/s)
8
4
50
20 2.4
8
4
50
20
1
16
8
32
8 3.47
8
4
50
20
32
2 2.97
24
36
16
12
24
12 3.1
8
16
24
16
8
16 2.5
6
8
4
50
20 2.5
1229
𝟐� 〗 ^�

> 3/4 𝑖𝑛 ∴𝒔𝒂𝒇�!