Technical features
Medium: Operating pressure: Internal leakage: Materials:
Air, oxygen or neutral gases 0 ... 7 bar (0 ... 101 psi) < 10-2 mbar l/s (≈0,6 ml/min) Body: Stainless steel only or
Orifice: Back pressure: 0 ... pmax stainless steel/brass
4,5 mm Maximum 10% of inlet pressure External leakage: PEEK (only when mounted on sub
Filtration: Mounting: < 10-2 mbar l/s (≈0,6 ml/min) base)
A filtration of 20 micrometer is Cartridge, manifold p = 9,5 bar Seal: FPM, NBR, EPDM
required before the inlet Size: Weight:
Operation: 16 mm < 50 g (0.11 lbs) Manifolds
2-way valve Normally closed Life expectancy: Ambient/media temperature: Contact your local fluid control
Hysteresis: ≥ 100 Mio. cycles (with triangular +10 ... +50 °C (+50 ... +122°F) specialist for information about
See diagrams on page 2 signal) our manifolding capabilities which
include laminated polymer
manifolds.
Our policy is one of continued research and development. We therefore reserve the right to amend, without 01/16
notice, the specifications given in this document. (2016 - 6008a) © 2015 Fluid Automation Systems s.a. en 6.6.009.01
FAS 16 mm FLATPROP EQI
Pressure compensated proportional valve
Additional information
Typical flows vs. supply pressure Typical Hysteresis curves
Air, 20°C, without back pressure Air, 20°C, without back pressure
Stdl/min
l/min
300
350 p = 7 bar
250
300
250 200
Max. flow
p = 3 bar
200 150
Flow
150
100
100
50
50
p = 0,1 bar
0
0
0 1 2 3 4 5 6 7 bar 0 100 150 200 250 300 350 400 mA
Note: Accessories
Flow vs. supply pressure curves are for informative purposes only and shall be used Manifold for cartridge version
only for the pre-selection of the orifice size. Preliminary testing is recommended to with G1/4 ports in aluminium
take into account all application specific requirements and to select the most
adequate orifice. For further information contact your local fluidic specialist.
Page 3
S120.0152
300 ± 10
5
2,5 ± 0,05
22,3
ø15 ± 0,1
± 0,4
38,1
44,7
0,75 ± 0,05
2 2
1
6,7
7,4
1 2 3
1
5
9,7 4,2
6
3,8
300 ± 10
4 14
,8
15,5
,8
ø1
14
6,6
17
Our policy is one of continued research and development. We therefore reserve the right to amend, without
en 6.6.009.02 notice, the specifications given in this document. (2016 - 6008a) © 2015 Fluid Automation Systems s.a. 01/16
FAS 16 mm FLATPROP EQI
Pressure compensated proportional valve
A-A
ø 5 +0
-0,2
A 0,2 A B
B 11,7
G1/4
0,2 x 45°
11,6 + 0,2
12
B 1
6,4 ± 0,2
ø14,8 ± 0,05
15°
ø7,6 H7
ø14 H7
ø 9,09
ø17
50
0,1 A B 0.8
≥8,5
30°
0.8
12
,45
R0 0,05 A B
30 10
A B 0,1 A B
3,7 ± 0,1 0,7 G1/4
1,5 11,3 30
20,5 0,02 A
0,2 A B 12,8
≥15,3 A
B-B
M3
11
0,1 A B
1,55
Warning
These products are intended for use in air, oxygen and neutral gas The system designer is warned to consider the failure modes of all
systems only. Do not use these products where pressures and component parts used in fluid power systems and to provide adequate
temperatures can exceed those listed under »Technical features«. safeguards to prevent personal injury or damage to equipment in the
event of such failure.
Before using these products with fluids other than those specified,
for non-industrial applications, life-support systems, or other System designers must provide a warning to end users in the system
applications not within published specifications, consult instructional manual if protection against a failure mode cannot be
IMI Precision Engineering, Fluid Automation Systems s.a. adequately provided.
Our policy is one of continued research and development. We therefore reserve the right to amend, without
01/16 notice, the specifications given in this document. (2016 - 6008a) © 2015 Fluid Automation Systems s.a. en 6.6.009.03
Diese Produkte sind ausschließlich mit Druckluft-, Sauerstoff- und neu- Systemauslegern wird dringend empfohlen, die Störungsarten aller
trale Gassysteme zu verwenden. Sie sind dort einzusetzen, wo die unter in Pneumatiksystemen verwendeten Komponententeile zu berück-