Aer-O-Foam®

XL-3C6
Fluoroprotein Foam Concentrate
NFC120

Assurance Use At 3% On Hydrocarbons, Fuel for use on most polar solvents or water
Oxygenates And Biodiesel miscible fuels such as alcohols, ketones,
Firefighting and environmental esters, and ethers. However, Aer-O-Foam
performance you can rely on Superior Quality Fluoroprotein Foam
XL-3C6 3% has been found to be suitable
Concentrate
National Foam prides itself on the open for use on slightly polar fuels such as
and honest way in which we conduct our Suitable for use with fresh or sea MTBE, ETBE, TAME, MTBE/gasoline motor
business throughout the world. Our foam water. fuel blends and biodiesel (methyl ester
concentrates are an extension of our from lipid sources).
Compatible with standard
ethical beliefs and we pride ourselves in proportioning and air aspirating
Typical storage tank systems include
being the responsible foam manufacturer, foam making devices.
surface (topside) application or subsurface
balancing high performance with
Stable long-lasting foam blanket injection. Other uses include, loading
minimal environmental impact.
provides excellent burnback resistance. racks, docks, process areas, spills, etc. For
best performance, fluoroprotein foam
C6 Technology Suitable for use with foam compatible
concentrates should be used with aspirating
C6
dry powder extinguishing agents.
Aer-O-Foam XL-3 3% is a superior nozzles and foam making devices.
quality, extremely versatile, fluoroprotein Underwriters Laboratories, Inc.
foam concentrate which is used at Typical Physical Properties
Underwriters Laboratories of Canada
3% to extinguish fires in hydrocarbon (ULC).
fuels and selected fuel oxygenates. Appearance......................... Dark Brown Color
The C6 Fluorosurfactants have been Aer-O-Foam XL-3C6 3% is manufactured Specific Gravity at 68°F(20°C) ..................1.16
developed and refined specifically utilizing a unique process which pH ................................................................................7.3
to lower the environmental impact produces unmatched quality protein Viscosity at 68°F(20°C) ........................19.0 cST
without reducing performance. This hydrolzate to form the foundation Freezing Point ......................................8°F(-13°C)
new formulation demonstrates National for the concentrate formulation. The Min Usable Temperature...............20°F(-7°C)
Foam’s commitment to superior protein base provides a long lasting Max Usable Temperature ..........120°F(49°C)
flexibility, firefighting performance, and stable foam blanket, highly resistive
environmental responsibility. to the effects of heat. This prevents Underwriters Laboratories Listed
reignition and enhances burnback Type II Application Rates
resistance. Fluorochemical surfactant
additives are combined with the protein Application Rate
Fuel Group gpm/ft2 (l/m/m2)
base to increase fluidity of the foam Hydrocarbons ....................................................0.10 (4.1)
enabling it to seal around obstructions. Methyl Tertiary Butyl Ether.........................0.12 (4.9)
Ethyl Tertiary Butyl Ether .............................0.12 (4.9)
Aer-O-Foam XL-3C6 3% is used in fire Tertiary Amyl Methyl Ether ........................0.12 (4.9)
suppression systems and manual 17.5% MTBE/82.5% Gasoline ....................0.10 (4.1)
applications to fight fires involving Biodiesel:
hydrocarbon fuels such as crude oil, (Methyl Ester from lipid sources) ...........0.10 (4.1)
gasoline, and fuel oils. It is not suitable Please refer to UL Fire Protection Online Certifications Directory for
additional information on application rates and other discharge devices.
Aer-O-Foam® XL-3C6
Fluoroprotein Foam Concentrate

Storage and Handling freeze during shipment or storage, no Environmental and Toxicological
performance loss is expected upon Information
Aer-O-Foam XL-3C6 3% is ideally stored thawing.
in its original shipping container or in National Foam Concentrates do not
tanks or other containers which have It is recommended that Aer-O-Foam XL- contain PFOS in accordance with USEPA
been designed for such foam storage. 3C6 3% not be mixed with any other type Stewardship Program 2010/15.
Recommended construction materials of foam concentrate in long term storage.
are carbon steel, high density cross-linked Such mixing could lead to chemical Prevent foam concentrate and foam
polyethylene or reinforced polyester changes in the product and a possible solution from entering ground water,
(isophthalic polyester resin) with a vinyl reduction in or loss of firefighting surface water, or storm drains. Discharge
ester resin internal layer coating (50-100 capability. Most expanded foams are and disposal of Aer-O-Foam XL-3C6 3%
mils). Refer to National Foam Technical compatible for side-by-side application concentrate or foam solution should be
Bulletin NFTB100 for further information. during an incident. made in accordance with federal, state,
and local regulations. Refer to National
Foam concentrates are subject to Shelf Life, Inspection, and Testing Foam Technical Bulletin NFTB110 for
evaporation which accelerates when further information.
the product is exposed to air. Storage The shelf life of any foam concentrate is
tanks should be sealed and fitted with maximized by proper storage conditions Aer-O-Foam XL-3C6 3% has not been
a pressure vacuum vent to prevent free and maintenance. Factors affecting tested for acute toxicity, primary skin
exchange of air. The recommended shelf life are wide temperature changes, or primary eye irritation. Repeated skin
storage environment is within the UL extreme high or low temperatures, contact will remove oils from the skin and
listed temperature range of 20°F to 120°F evaporation, dilution, and contamination cause dryness. Aer-O-Foam XL-3C6 3% is a
(-7°C to 49°C). When product is stored by foreign materials. Properly stored Aer- primary eye irritant and contact with the
in atmospheric storage tanks, contents O-Foam XL-3C6 3% has been tested and eyes should be avoided. Users are advised
must be covered with 1/4-inch (6.35mm) shown no significant loss of firefighting to wear protective equipment. If Aer-O-
of National Foam Seal Oil to ensure performance, even after 25 years. Foam XL-3 enters the eyes, flush them well
prevention of air coming into contact with with water and seek immediate medical
the foam concentrate. Use of Seal Oil is Annual testing of all firefighting foams attention. For further details, see the Aer-O-
only recommended in stationary storage is recommended by the National Fire Foam XL-3C6 3% Safety Data Sheet NMS120.
tanks. Refer to National Foam product Protection Association (NFPA). National
data sheet NFC950 for further information. Foam provides a Technical Service Program
to conduct such tests. Refer to National
Aer-O-Foam XL-3C6 3% foam concentrate Foam product data sheet NFC960 for further
is freeze/thaw stable. Should the product details on Technical Service Program.

Ordering Information
Container Shipping Weight Shipping Dimensions Part Number
3
5-Gallon Pails (19 liters) 51 lb. (23.1 kg) 1.13 cu. ft. (0.032 cu. m) 1111-1340-4
3
55-Gallon Drums (208 liters) 554 lb. (251.3 kg) 11.51 cu. ft. (0.326 cu. m) 1111-1481-4
275-Gallon IBC Reusable Tote Tank (1041 liters) 2794 lb. (1267.4 kg) 51.11 cu. ft.3 (1.1061 cu. m) 1111-1725-4
3
330-Gallon IBC Reusable Tote Tank (1249 liters) 3346 lb. (1517.7 kg) 55.8 cu. ft. (1.580 cu. m) 1111-1033-4
Bulk 9.67 lb./gal. (1.16 kg/l) 1111-1001-4

24hr RED ALERT® : 610-363-1400 • Fax: 610-431-7084 Page 2 of 2

National Foam National Foam operates a continuous programme of product development.


350 East Union Street, West Chester, PA 19382, USA The right is therefore reserved to modify any specification without prior notice
Email: info@nationalfoam.com and National Foam should be contacted to ensure that the current issues of all
technical data sheets are used.
www.nationalfoam.com
© National Foam
10/16 NFC120 (Rev J)