PowerCube 1000 Hybrid Power Solution

ICC500-HA2-C6 Datasheet

Introduction

ICC500-HA2-C6 is an outdoor cabinet system used for


diesel/grid scenario, it integrates a HEX cooling system. The
system configures DCDU-300AN1, maximum 300 A system
capacity, supports 6 rectifiers, the equipment cabin reserves 19-
inch rack space for other equipments, occupies small footprint,
easy installation and deployment.

Features

 Small size, easy deployment


 Compact design for installation of equipment
 Separated battery cooling from equipment for energy saving
 High rectifier efficiency of over 96%
 Rectifier modules are hot-swappable to simplify operation
 Intelligent battery management function helps to prolong
ICC500-HA2-C6
battery lifespan
 Easy installation & maintenance by front and rear door design

Scenarios

 Outdoor
 Diesel/grid hybrid system
Specifications
Product Type ICC500-HA2-C6
Dimension (W × D × H) 770 mm × 1305 mm × 1825 mm (Including base and protruding part)

Base (W × D × H) 770 mm × 895 mm × 100 mm

Weight ≤ 315 kg (without rectifier modules and battery)


System
Installation Mode Ground installation

Cabling Mode From the bottom

Maintenance Mode From the front and rear

Inner Rack & Space 14 U, 19-inch rack (according to actual configuration)


Equipment
Protection Level IP55
Cabin
Cooling Mode HEX: 150W/K

Inner Rack & Space NA

Battery Type TCB-A/FCB-A, Max. 650Ah


Battery Cabin
Protection Level IP55

Cooling Mode PC500D DC air conditioner

Power Model DCDU-300AN1

200-240/346-415 Vac, Three-phase, 50/60 Hz, Max. 34 A or


AC Input 200-240 Vac dual-live wire, 50/60 Hz, Max. 102 A or
Input 200-240 Vac single-phase, 50/60 Hz, Max. 102 A

DC1 Input -40 Vdc to -60 Vdc, Max. 300 A

Voltage -48 Vdc


Output
Capacity Max. 300 A

AC Output & Socket 1 × 10A/16 A MCB, 1 × 10 A (maintenance socket, optional)


Power System
Battery Branch 2 × 160 A Fuse

LLVD Branch 2 × 80 A MCB, 2× 63 A MCB

BLVD Branch 4 × 32 A MCB, 2× 16 A MCB, 1 × 10 A MCB

20/40 kA (8/20 μs) (optional)


AC Input
SPD 30/60 kA (8/20 μs) (optional)

DC Output 10/20 kA (8/20μs)

Signal Input & Output 9 DI, 2 AI, 1 SMOKE, 1 TEM_HUM, 1 WATER, 10 DO (according to actual configuration)

Noise ≤65 dB(A) @1.5m, satisfy the GR487 standard

Optional Lighting LED


Accessories Sensor Smoke, water, door switch, temperature & humidity etc.

Operating Temperature -10ºC to +50ºC (Including solar radiation)

Environment Storage Temperature -40ºC to +70ºC

Operating Relative Humidity 5% to +95% (no condensation)

Altitude 0 to 4000 m (1ºC per 200 m temperature derating from 2000 to 4000 m)

Remark:
 ICC: Integrated Control Cabinet  DCDU: Direct Current Distribution Unit  SPD: Surge Protective Device  HEX: Heat exchanger

 DC1 Input: 3rd part DC input, such as: solar energy input, reused existing -48V DC power input etc.

Copyright © Huawei Technologies Co., Ltd. 2016. All rights reserved. HUAWEI TECHNOLOGIES CO., LTD.
No part of this document may be reproduced or transmitted in any form or by any means without prior written consent of Huawei Technologies Co., Ltd. Huawei Industrial Base
General Disclaimer Bantian Longgang
The information in this document may contain predictive statements including, without limitation, statements regarding the future financial and operating Shenzhen 518129, P.R. China
results, future product portfolio, new technology, etc. There are a number of factors that could cause actual results and developments to differ materially
from those expressed or implied in the predictive statements. Therefore, such information is provided for reference purpose only and constitutes neither an Tel: +86-755-28780808
offer nor an acceptance. Huawei may change the information at any time without notice.
www.huawei.com