SUPRAFINE

100+Kgs
PULLOUT STRENGTH

Rotary Stitching Cross Tee Main Beam with Super Lock


With Hardened Clip Integrated C3 Coupling Standard lay-in installation of 15mm exposed
suspension system using Microlook tiles

BENEFITS
• Connection strength • Hot dipped galvanized
- Clip staked-on end detail (stamped from a separate piece - Resists red rusting better for long term system performance.
of high grade steel) provides double lock connection
between Tee to Tee & Tee to Main Beam for perfect alignment. • Peakform
- Superlock clip for strong, secure connection. Profile to increase stength & stability for improved performance.
- The stab system locates with an audible “click”, ensuring a
secured connection.
- Pull out strength over 100Kgs, exceeding seismic requirement. APPLICATION AREAS
• Offices
• Rotary Stitched for strength • School
- The unique “rotary stitched” construction mechanically locks • Hospitality
together the two metal layers of the vertical web in a • Retail
sophisticated in-line process enhancing the torsional strength • Healthcare
and stability.
SUPRAFINE
30 YEAR
warranty with Armstrong Tiles #

Rout Pcs /
Drawing Item Description Length Height Width Load (Kg/m)
Spacing Ctrn.
Suprafine43
Suprafine 43 MB

BP754042 Main Beam 100 3600 43 15 18.6 Kg/m 20

Suprafine 43 CT
BP753042 Cross Tee 600 1200 43 15
- 60
BP752042 Cross Tee - 600 43 15

Suprafine 38
BP754033I Main Beam 150 3600 38 15 20

38 MB BP753032CI Cross Tee 300 1200 38 15 15 kg/m 60


BP752032I Cross Tee - 600 38 15 60
BP752432I Cross Tee - 300 38 15 120
e38 CT BP751232I Cross Tee - 150 38 15 240
Suprafine 32 BP7542102I Main Beam 150 3000 32 8.8 kg/m 20
Suprafine 32+ 15
BP7542102Z120I* Main Beam 3000 32
e32 MB
BP7530102I Cross Tee 600 1200 32 60
BP7530102Z120I* Cross Tee 1200 32
15 -
BP7520102I Cross Tee 600 32 60
BP7520102Z120I* Cross Tee 600 32
e32 CTWall Angle
BPT1945HI Wall Angle 3000 19 19 30
- -
BPT 2222H Wall Angle 3000 22 22 30

BP784003I Shadow Moulding - 3600 19x7 7x14 - 30

* Suprafine 32+ for CPWD HANGER SPACING @1200mm

*ASTM Class Applicaion Armstrong Recommendation

HD - Heavy-duty (23.8 Kg/m) for Commercial with load of heavy service fixtures Seismic instalation of DEF* building material

ID - Intermediate-duty (17.88 Kg/m) for Residential/Commercial with load of service fixtures Seismic instalation of C* & area >250 sqm

LD - Light-duty (7.45 Kg/m) for Residential/Commercial without load of service fixtures

#
Warranty offered only when ceiling tiles installed with Armstrong steel angles and installation is carried out as per Armstrong recommendations.
For more details please refer the Armstrong India website.