Antenna line device 1. Check the compatibility between the antenna line device and the BTS SW.
configuration failure
detected 2. Check that the given parameters are in the valid range. In RET case tilt angle is
within range (-30 to 30 degrees).
4. Issue a HW reset for the RF module from BTS Site Manager to introduce
power-off reset to the antenna line devices.
Antenna line device 1. Check the compatibility between the antenna line device and the BTS SW.
operation failure detected
2. Check that the given parameters are in the valid range.
3. Issue an HW reset for the RF module from BTS Site Manager to introduce
power-off reset to the antenna line devices.
file:///C:/Users/mikael%20molina/Downloads/7607_TRX_Operation_Degraded.html 1/17/2020
7607 TRX Operation Degraded Page 2 of 8
Backoff applied by Radio 2. Either reduce the power level OR increase the power reduction threshold by
module is above the power append commissioning OR commission with default value "0" for power
reduction threshold reduction threshold.
Baseband bus major 1. Check that SFP plugins are correctly installed.
operation error occurred in
the System Module 2. Check that the optical SFP plugin matches the optical cable type (i.e. multi
mode or single mode cable).
3. Check the condition of the optical cables and connectors and replace them if
broken.
CMST licensing inadequate 1. Add CMST cell's RRH nodes count license at least equal to number of RRH
nodes minus 3 belonging to CMST cell
2. Decrease RRH nodes count belonging to one CMST cell in BTS SCF file
2. Replace RF module.
Frequency band mismatch or 1. Ensure that Antenna Line Device connected matches with the information
commissioning error in the provided in the SCF.
antenna line device
2. If Antenna line Device (MHA/RET) was added to a powered on RF Module, a
Manual RF Module reset must be triggered to cancel this alarm (recommendation
is to connect MHA/RET to a powered off RF Module and after connection,
power on the RF Module).
3. If the alarm still persist then replace the Antenna line Device (MHA/RET).
file:///C:/Users/mikael%20molina/Downloads/7607_TRX_Operation_Degraded.html 1/17/2020
7607 TRX Operation Degraded Page 3 of 8
RF module configuration Remote: Give BCF reset from BSC or issue a HW reset to the RF Module from
failure remote 2G Flexi BTS manager.
Local:
RF Module detected antenna 1. Check the antenna line and antenna line devices. Make sure that the antenna
line device failure line connectors are in the right torque.
2. Issue a HW reset for the RF module from BTS Site Manager to introduce
power-off reset to the antenna line devices.
RF module detected LNA 1. Issue a RF module HW reset from BTS Site Manager to allow alarm re-
failure evaluation.
2. Replace RF module.
RF module detected missing 1. Issue a RF module HW reset from BTS Site Manager.
TX feedback signal
2. If alarm persists, replace RF module.
file:///C:/Users/mikael%20molina/Downloads/7607_TRX_Operation_Degraded.html 1/17/2020
7607 TRX Operation Degraded Page 4 of 8
RF module detected RET 1. Check the antenna line for any damage affecting the current supply to the
Antenna Control Failure RET.
3. If RET is connected in chain with another ALD device, check for any fault on
the previous in chain ALD device, in case of fault in the previous in chain
device replace that device, and trigger a Radio Module reset.
RF module detected too high 1. Issue a RF module HW reset from BTS Site Manager.
or low Tx power
2. If alarm persists, replace RF module.
RF module detected VSWR This alarm is activated, when user definable minor VSWR alarm threshold has
above minor limit been exceeded.
1. Check the condition of the feeder and jumper cable, their connectors, sockets
and connector seals starting from BTS end and proceed towards the antenna
end.
3. With external test equipment, measure the Return loss/VSWR of the antenna
line. Perform step 1 again, if the measurement result is higher than expected.
4. Check the VSWR alarm threshold limits. If peer technology is radio master,
VSWR alarm limits are inherited from there.
5. Replace RF module.
RF module detected RF module uses an internal configuration file and now either conflicting or
configuration file failure corrupted data in the configuration file has been detected. Default internal
parameters are used, performance might be degraded.
file:///C:/Users/mikael%20molina/Downloads/7607_TRX_Operation_Degraded.html 1/17/2020
7607 TRX Operation Degraded Page 5 of 8
RF module TX output power 1. Observe the ambient temperature. If it reaches more than +50 degrees, the
is reduced (at max 3.0 dB) to behavior of RF module is expected. Try to cool down the environment a little.
prevent overheating
2. If ambient less, check that RF module is not covered with debris or is almost
touching other hot artefact. Otherwise, replace RF module.
RSSI detected Rx signal Supplementary information fields of RSSI alarm from the BSC history will give
difference exceeding further details of which antenna has exceeded the threshold value.
threshold
FlexiMulti/FlexiMulti10:
1. Check RSSI results with BTS Manager which antenna appears to have
abnormal values. If abnormal values are lower than values from other antennas,
it indicates a disconnected or faulty cable in the loop or a faulty LNA. If
abnormal values are higher than values from other antennas, it indicates
interference coming outside of the BTS or a faulty cable/module.
2. Check whether the selectable RSSI Sample Count is correct considering the
BTS site environment.
3. Check that the RXDL parameter at the BSC is set to a reasonable value,
taking into account the site condition in order to prevent unnecessary alarms.
Local:
file:///C:/Users/mikael%20molina/Downloads/7607_TRX_Operation_Degraded.html 1/17/2020
7607 TRX Operation Degraded Page 6 of 8
5. Check that optical cable is connected and correctly mated between System
Module and RF Module (FXxx).
6. Check that the optical SFP plug-in matches the optical cable type (that is, multi
mode or single mode cable) at both ends. Replace in case broken.
Too few antennas available 1. Check the antenna line settings to the local sector.
for Rx diversity
2. Check that all RF modules providiing Rx diversity are up and running.
TRX provides reduced Reduce sector's TRX configuration so that shared DTRX module
traffic services; invalid Rx
becomes unshared between two sectors, or add new DTRX module
diversity config at EXxA
to cope with diversity Rx for the sector that is sharing one DTRX
module with another sector.
file:///C:/Users/mikael%20molina/Downloads/7607_TRX_Operation_Degraded.html 1/17/2020
7607 TRX Operation Degraded Page 7 of 8
Tx antenna cannot be 1. If BTS platform is flexi multi 10 and release is GF1.0, avoid to configure
allocated for IDD Auxiliary following odd TRX ID:s 3,9,15,21,27,33. For these the auxiliary path
TRX in RF module configuration is not supported.
2. Ensure that 'per TRX power' value of the local sector is correct, so that
Auxilary TRX can be accomodated to the existing antenna lines.
3. Ensure that the IDD TRX is configured to the correct sector at BSC.
4. Allocate another antenna line in the same sector for the IDD TRX via
recommissioning.
5. After correcting the any of the above fault, issue TRX/Sector (b)lock/un(b)
lock.
TRX object allocation failed 1. Check the alarm diagnostic/supplementary info field (first digit):
in RF module
• "01": This indicates that RF Module is dumb or not connected.
• "02": Ensure that 'per TRX power' value of the local sector is correct and
not exceeding the maximum combined Tx output power. Additionally,
next digit (shelf info) "01" indicates that dynamic power pooling feature
is not allowed with MOBSS, Baseband/AH hoping, IDD 2UD/4UD
enabled sector.
file:///C:/Users/mikael%20molina/Downloads/7607_TRX_Operation_Degraded.html 1/17/2020
7607 TRX Operation Degraded Page 8 of 8
• "08" TRX added to the antenna hopping sector at runtime and cannot be
part of antenna hopping.
• "09" Frequency of the carrier is less than the lower bound frequency of
the pipe
2. After these checks and related corection(s), lock/unlock the sector containing
the impacted TRX objects.
4. Replace RM/RRH.
file:///C:/Users/mikael%20molina/Downloads/7607_TRX_Operation_Degraded.html 1/17/2020