2178

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

Abu Dhabi :- Tel : +97125502004 Dubai :- Tel : +97142668808 Doc No : CR/SD-07927/03

Fax : +97125503662 Fax : +97143388280 UID : 345259


Email : info@tuvsw.com Website : www.tuvsw.com Inspection Date : 10/04/2019

MAGNETIC PARTICLE INSPECTION REPORT


Owner / Customer GERMAN STEEL CONTRACTING LLC
Client Name GERMAN STEEL CONT.LLC
Project / Vessel Yas South Integrated Destination Resort (Family hotel Project) Order No 3443

Item Description EMBEDMENT PLATE STUD WELD


Job Location UMM AL QUWAIN Material Thickness VARIOUS THICKNESS
Surface Condition As Welded Surface Temperature Ambient
Post Weld Heat Treatment NA Weld Process SMAW
Ref Drawing No NA Illumination DAY LIGHT

Yoke Sl No Calibration Due Sensitivity Type of Magnetization


2035 28/01/2020 BC STRIP LONGITUDINAL
Testing Techniques Type Of Magnet Magnetic Ink Make White Contrast Make
WET CONTINUOUS PERMANENT MAGNET CHEMETALL CHEMETALL

Extent Of Testing Test Specification Test Procedure Acceptance Criteria


10% ASTM SE 709 SW/TIP-MPT/AWS/001RV3 AWS D1.1

Examination Remarks :-
10% Magnetic Particle Inspection was carried out on Stud Weld :

Stud Weld Located on Embedment Plate = A21 & A41

Lifting Pad Eye Located on Embedment Plate 100% MPI Done

Test Result : No relevant indications was observed during the inspection / Acceptable as per specification
SPACE FOR AUTHORISED SIGNATORIES
Test performed by Witnessed / Reviewed by
TUV Southwest CLIENT CLASS / TPI
Name : SATHYAN SELVAM Name : Name :

Qualification : ASNT NDT Level II Designation : Designation :

Signature : Signature : Signature :

Date : 10/04/2019 Date : Date :

DAC Accreditation No. IB-055


Powered by TCPDF (www.tcpdf.org)