Suitable for use in situations where heavy dynamic or mobile Conbextra EP300 product is resistant to oil, grease, fats,
loads are encountered. The gap between a base plate and most chemicals, mild acids and alkalis, fresh and sea water.
substrate will need to be filled in such applications as Consult Fosroc’s Technical Department when exposure to
reciprocating machinery, testing equipment, heavy crane and solvents or concentrated chemicals is anticipated.
transporter rails, high speed turbines, centrifuges and drop
forges. Exotherm
Also for use in conditions where chemical spillage may be Conbextra EP300 epoxy system will develop an increase in
encountered. Typical situations could be met in steelworks, temperature on mixing. Its extent will be a function of the
refineries, electroplating works and chemical plants. volume to surface ratio, the ambient temperature as well as
the mass and thermal conductivity of the surrounding
Conbextra EP300 is especially suitable where extended materials. Contact Fosroc for specific data on the product.
working time and large volume pours, deep gaps or high
ambient temperatures. It is also suitable for re-profiling and
Typical on-plate shutter system
waterproofing works of pile caps.
Removable hopper: For larger pours the grout may be
Advantages hand placed or pumped into a removable hopper (trough).
Technical Support
Page 1
Conbextra EP300
Properties Mixing
Test Method Typical Results Pour all the contents of the hardener pack into the base
Density (kg/m ):
3
1950 container. Mix using a slow speed power mixer until
Compressive strength @ 40oC homogeneous.
(N/mm2) ASTM C579:
3 days 80.0 Pour all the mixed liquid into a container then add all the
7 days 100.0 filler gradually. Mix using a slow speed power mixer for two
2 minutes or until a uniform colour is achieved in the grout.
Tensile strength (N/mm )
ASTM C307, 7 days: 16
Placing
Flexural strength (N/mm2)
ASTM C580, 7 days: 38
The mixed grout should be poured steadily from one side
Modulus of elasticity only to eliminate the entrapment of air.
2
(KN/mm ) ASTM C580, 7 days: 14.0
Linear shrinkage (%) Continuous grout flow is essential.
ASTM C531, 7 days: 0.08
Linear coefficient of thermal Sufficient grout must be available prior to starting.
-6 o
expansion 10 (mm/mm C)
ASTM C531: 45 The time taken to pour a batch should be regulated to the
Linear shrinkage of cured material time taken to prepare the next batch.
ASTM D2566: 0.0002
Pot life at 40oC ASTM D2471 (min): 120 Flow Characteristics
Peak exothermic temperature
at 40oC (ASTM D2471): 50 The maximum distance of flow is governed by the gap
Water absorption (%) thickness, the head of grout applied and the ambient
ASTM C413: 0.14 temperature. The following table gives typical data for flow
design.
Application Instructions
Gap thickness Hydrostatic Maximum
o
C (mm) head (mm) flow (mm)
Preparation
40 10 100 600
40 150 100 1500
Foundation surface 40 300 100 2000
All contact surfaces must be free from oil, grease, free Cleaning
standing water or any loosely adherent material. Concrete
surfaces should be cut back to a sound base. All dust must All tools and equipment should be cleaned immediately
be removed and boltholes or fixing pockets blown clean of after use with Fosroc Solvent 102. Spillages should be
any dirt or debris. absorbed with sand or sawdust and disposed in
accordance with local regulations.
Steel surfaces
Limitations
All steel surfaces should be shot blasted free of rust and flaky
mill scale SA 2½. Cleaned surfaces may be protected by the
Grouts should not be placed in any unrestrained situation,
application of Nitoprime 28.
i.e. base plate plinths, etc. Failure to comply may lead to
Formwork crack development in the grout.
o
The formwork should be constructed to be leakproof as Conbextra EP300, at temperatures below 20 C the cure
Conbextra EP300 product is free flowing grout. Loss of grout rate may be slow, but will go to completion provided the
once the material is placed, but not hardened, will result in temperature remains above 5oC.
incomplete filling of the gap.
Careful planning of shuttering should be made to reduce
For free flow grout conditions it is essential to provide a exposed surfaces of epoxy grout and shoulders to an
hydrostatic head of grout. To achieve this a feeding hopper absolute minimum. Exposure to cyclic temperature
system should be used. changes is likely to cause cracking and peeling in
unrestrained grout. Please contact Fosroc for further
For deep section placing in inaccessible, extended widths details.
chains may be used to encourage lateral movement and
complete filling of the gap, thus eliminating air pockets. For
further information please contact Fosroc for specific advice.
Fire
Important note:
Fosroc products are guaranteed against defective materials and manufacture and are sold subject to its standard Conditions
for the Supply of Goods and Services, copies of which may be obtained on request. Whilst Fosroc endeavours to ensure that
any advice, recommendation, specification of information it may give is accurate and correct, it cannot, because it has no di rect
or continuous control over where or how its products are applied, accept any liability either directly or indirectly arising from the
use of its products, whether or not in accordance with any advice, specification, recommendation of information given by it.
Registered Office: Industrial Area, Phase 4, Road No. 102, Street No. 82
Page 3 FO SA/CONBEXTRA EP300/2205/16