SPECIFICATION OF UNIVERSAL HART COMMUNICATOR

S. NPCIL REQUIREMNT VENDORS


NO. CONFIRMATION
01 The HART Communicator should be Universal HART
Communicator.
02 The Universal Hart Communicator is required to calibrate &
communicate with various Temperature , Pressure , Level
transmitters etc. of different standard manufacturer Like
Emerson/ Yokogawa/ ABB/ SMAR/ SEIMENS/ FUJI etc. Some
examples of the HART protocol support required for instruments
are:
Temperature
Manufacturer Pressure instruments
instruments
1151 3044C
2088 644
Rosemount
3001C 3144
3051, 3051S 3244, 3144P
YTA 110, 310
Yokogawa EJA
and 320
FCX
Fuji FRC
FCXAZ
Foxboro/Invensys I/A Pressure
03 The Hart Communicator Should have ability to read Message,
tag, descriptor, calibration date, sensor PV information, PV
output information, Write PV ranges (upper and lower), Write
tag, description etc.
04 The Universal HART Communicator should be able to select &
change Unit of Pressure & Temperature Through Universal
HART Communicator.
05 The Hart Communicator Should be able to Set zero offset, Trim
DAC zero (mA output 4 mA), Trim DAC gain (mA output 20 mA)
06 The HART communicator should be supplied alongwith
Standard Software to Update new device profiles (DD File) and
firmware via Internet connection
07 The Universal HART Communicator should have Memory
Dedicated memory / minimum 2 GB memory card for up to 1000
HART device profiles store more than 200 device
configurations.
08 The Universal HART Communicator should have a keyboard
with Alphanumeric & symbol Keyboard, Power On Of Button,
Up & Down, enter keys etc. for editing and operation.
09 The Universal HART Communicator should have wide screen 6
lines dot matrix graphic backlit LCD Display, 128 x 64 pixel dot
matrix or better
10 Continuous run time
--100 hours approx without backlit
-- 60 hours approx with minimum backlit
--Programmable auto power-off.
11 Operative limits
Temperature limits : –10 and +70 °C (+14 and +158 °F)
Storage : –20 and +70 °C (–4 and +158 °F)
12 Environmental limits
Humidity - Relative humidity: up to 100 %.
13 Case Materials
- Glass fiber reinforced, flame resistant, anti-static
14 The Universal HART Communicator should come alongwith
250ohm Resistor, Silicon rubber protective shell, Soft Carrying
bag, Hard Carrying case, Standard banana jack with lead set
with insulated minigrabbers clip, Software CD, Rechargeable
battery, 4 disposable battery with battery assembly, Charger,
Communication cable etc.
15. Lifelong valid licensed version OR Freely upgradable licenses for
software or firmware etc.
16. HART protocol revision: Rev. 6.0 OR Higher

Database Software: Should be easy compatible with OS Windows -7


and higher
17. Three (03) year warranty OR More for all hardware parts
18. Make & model