Dux Commercial Brochure JUL19
Accessories 19
1
GROUND BREAKING
COMMERCIAL WATER HEATING
We are dedicated to highest quality, great design and
innovation, offering a comprehensive range of continuous
flow solutions to suit most commercial projects
The Dux Commercial range Dux Commercial has a water flow rates of as low as 2.5L/min
has been especially developed heating system to meet your up to a massive 1,200L/min or up
and designed for commercial project requirement. 72,000L/hr.
applications by incorporating larger
Our range has the ability to link With safety, durability, and reliability
more robust heat exchangers.
together from 2 up to 24 units and our water heaters are the ultimate
Whether it is an apartment, hotel, the capacity to meet hot water commercial solution.
office block or restaurant,
The Dux Commercial range is designed for All Dux Commercial Continuous flow products have a 5 year
commercial applications which have greater warranty on the heat exchanger and a 2 year warranty on
daily water usage. heater parts and labour. When used in a domestic situation
12 year warranty on the heat exchanger and a 3 year
warranty on heater parts and labour.
1 hour a day 8 hours a day
Efficiency
Energy costs are reduced with up to 96.4% thermal efficiency
on the 32L & 50L condensing models. Modulating and
cascading the individual water heaters reduces the number
of units on at any time, thus improving plant efficiency and
reducing energy consumption - saving on total water
heating running costs.
Versatile installation
DOMESTIC COMMERCIAL
The Dux Commercial range has models for both indoor and
outdoor applications. Complete Manifold systems in wall
High grade commercial components such as mount or floor standing options are available, which reduce
heat exchangers with 25% thicker pipes and 20% installation time. This modular design also allow individual
thicker fins to allow the Dux Commercial range to water heaters and components to be transported with ease
meet the higher water use and flow rates required to buildings and where access may be difficult. There is also
for commercial applications. For greater water the option to order popular manifold arrangements with or
flow and lower pressure loss, Dux Commercial without water heaters installed on the manifold frame.
uses up to 50% larger pipes compared to those
used in domestic applications. Warranty*
All Dux Commercial Continuous flow products have a 5 year
warranty on the heat exchanger and a 2 year warranty on
heater parts and labour. When used in a domestic situation
12 year warranty on the heat exchanger and a
3 year warranty on heater parts and labour.
Commercial Domestic
2
THE BEST RANGE FOR COMMERCIAL HOT WATER
The Dux 50L commercial water heater is the largest capacity
50L OUTDOOR
DUX continuous flow water heater available in the Australian market. It
COMMERCIAL is specially designed for applications that demand extra delivery of
CONDENSING hot water with a smaller footprint.
50L & 32L
CONDENSING MODELS
Available in a range of Modular design enabling
capacities: 32L/min (indoor up to 24 units to be linked
& outdoor) and 50L/min together providing flow
(outdoor only) rates as low as 2.5L/min
up to 1,200L/min
The Dux 50L model
delivers savings - less time Low NOx burner provides
to plumb, less materials improved emissions and
used and less space air quality
consumed versus similarly
Commercial grade
32L INDOOR
32L OUTDOOR
>
>
> > > >
>
>
>
>
BURNER BURNER
>
>
>
>
>
>
>
>
>
>
>
HOT COLD
>
COLD WATER
>
>
28L OUTDOOR
enabling replacement of
Modular design enabling existing units
up to 24 units to be linked
Commercial grade
together providing flow
components throughout
rates as low as 2.5L/min
and durable silver finish
up to 672L/min
Indoor room sealed models
Low NOx burner provides
available with horizontal
improved emissions and
or vertical discharge and
air quality
open flue options
3
OUR INTELLIGENT CASCADING
MANIFOLD SYSTEM FUNCTION
ROTATION FUNCTION
4
A SOLUTION FOR
EVERY APPLICATION
Dux commercial continuous All frames come with
flow water heaters can be flexible connections
ordered either mounted on to water heaters
frame or supplied separately.
Manifold frame
Modular configuration installation options;
allows up to 12 units to be Wall mount, floor
manifolded, in combinations mount or back
of 2 and 3 water heater to back
frames
There are 6 different
Frames feature a solid frames available;
steel, hot dip galvanised
construction and are wind 28L; 2 unit or
rated up to 100m above 3 unit option
ground in regions A&B and 32L; 2 unit or
terrain category 2 3 unit option
All frames feature factory 50L; 2 unit or
mounted UV stable insulated 3 unit option
cold & hot water header
pipes, and a gas line.
Suitable for indoor and
outdoor installations
Manifold systems arrive to site ready for Frame comes with pipes, valves and hoses attached
connection to gas and water
Available to order in 2 & 3 manifold kits
Combinations of 2 and 3 manifold frames can be
combined for systems up to 12 units All kit models suit ‘wall’ or ‘floor’ mounting (feet are
provided with all models, & can be fitted if required)
Frames can be ordered with or without feet to suit
wall or floor mounting and also with the option for Once assembled on-site, the units will be as per a
'back-to back' installation complete systems supplied
Systems are custom built to specification ‘Back to back’ configuration available on request.
Large, commercial fit-outs Lifts on site to plant level are not available or too
small
Sites with goods lifts to plant level
Retrofit situations
Sites with crane access
For 'emergency' replacement situations where a
Reducing installation time on-site solution is required quickly
Note: Only available in 28L and 32L models.
Note: 50L models come as site mounted option only.
5
VARIATIONS OF THE SAME SYSTEM
EXAMPLE SYSTEM CONFIGURATION 2 X 28L MANIFOLD
FACTORY MOUNTED SYSTEM SITE MOUNTED SYSTEM
D22800ENF just add 'k' to the product code when ordering
D22800ENFK
6
ACCESSORY BOXES
All Dux commercial manifolded water heaters come The components of these boxes vary depending
standard with an accessory box on the system type
They typically contain a mixture of pumps, The most common accessory boxes are
system controllers, remote controllers, unions, displayed on this page
cables and end caps
2
8L; CFAB026 2 8L & 32L; CFAB020
3 2L & 50L; CFAB025 5 0L; CFAB027
2
8L; CFAB018 2
8L; CFAB007
3 2L; CFAB017
2
or 3 unit 50L; CFAB028 3
2L; CFAB019
5 0L; CFAB029
7
50L MANIFOLD SITE MOUNTED CODES
ONE CONTINUOUS FLOW WATER HEATER WITH STORAGE TANK
WATER HEATER FRAME ACCESSORY BOX STORAGE TANK
Manifold Kit
Model Number
Model Qty Model Qty Model Qty Model Qty
TWO CONTINUOUS FLOW WATER HEATERS WITH AND WITHOUT STORAGE TANK
WATER HEATER FRAME ACCESSORY BOX STORAGE TANK
Manifold Kit
Model Number
Model Qty Model Qty Model Qty Model Qty
THREE CONTINUOUS FLOW WATER HEATERS WITH AND WITHOUT STORAGE TANK
WATER HEATER FRAME ACCESSORY BOX STORAGE TANK
Manifold Kit
Model Number
Model Qty Model Qty Model Qty Model Qty
302
HOT WATER OUTLET(R1)
COLD WATER INLET(R1)
108
GAS INLET(R3/4)
67
35
830
85
800
125
181
UPWARD FLUE
246
DIVERTER 50L
CFC97
CONDENSATE DRAIN(R1/2)
466
428
302 HOT WATER OUTLET(R1)
184 COLD WATER INLET(R1)
108
GAS INLET(R3/4)
67
35
85
125
181
246
CONDENSATE DRAIN(R1/2) 8
32L MANIFOLD SITE MOUNTED CODES
ONE CONTINUOUS FLOW WATER HEATER WITH STORAGE TANK
TWO CONTINUOUS FLOW WATER HEATERS WITH AND WITHOUT STORAGE TANK
THREE CONTINUOUS FLOW WATER HEATERS WITH AND WITHOUT STORAGE TANK
9
28L MANIFOLD SITE MOUNTED CODES
ONE CONTINUOUS FLOW WATER HEATER WITH STORAGE TANK
TWO CONTINUOUS FLOW WATER HEATERS WITH AND WITHOUT STORAGE TANK
THREE CONTINUOUS FLOW WATER HEATERS WITH AND WITHOUT STORAGE TANK
10
OUR INTELLIGENT
MANIFOLD SYSTEM
CLIMATE WARM MODERATE ALPINE/COLD
MODEL Hot water set 40oC 60oC 75oC 85oC 40oC 60oC 75oC 85oC 40oC 60oC 75oC 85oC
Unit Minimum flow Maximum flow rate Maximum flow rate Maximum flow rate
Qty rate (L/min) (L/min) (L/min) (L/min)
50L Models
50L 1 2.5 50 31 23 19 50 28 21 18 42 25 19 17
D55000 5 2.5 250 156 114 96 250 139 104 89 208 125 96 83
D65000 6 2.5 300 188 136 115 300 167 125 107 250 150 115 100
D85000 8 2.5 400 250 182 154 400 222 167 143 333 200 154 133
D105000 10 2.5 500 313 227 192 500 278 208 179 417 250 192 167
D125000 12 2.5 600 375 273 231 600 333 250 214 500 300 231 200
32L Models
32L 1 2.5 40 20 15 12 32 18 13 11 27 16 12 11
D23200 2 2.5 80 40 29 25 64 36 27 23 53 32 25 21
D83200 8 2.5 320 160 116 98 256 142 107 91 213 128 98 85
D103200 10 2.5 400 200 145 123 320 178 133 114 267 160 123 107
D123200 12 2.5 480 240 175 148 384 213 160 137 320 192 148 128
28L Models
28L 1 2.5 35 18 13 11 28 16 12 10 23 14 11 9
D22800 2 2.5 70 35 25 22 56 31 23 20 47 28 22 19
D102800 10 2.5 350 175 127 108 280 156 117 100 233 140 108 93
D122800 12 2.5 420 210 153 129 336 187 140 120 280 168 129 112
11
TANK MANIFOLD SYSTEM
WITH STORAGE TANK
Tank Manifold systems are ideal The Tank Manifold systems come For example, a manifold pack of
when large flow rate is required. standard with 28L, 32L or 50L 12 x 32L units can provide up to
The 28L, 32L and 50L models continuous flow water heaters, 23,840L at a 50oC rise over a 2
can be used in a Tank Manifold a Dux Commercial storage tank, hour peak.
system. tank circulating pump and a
controlling thermostat.
Model Number UNIT QTY L/hr @ 50°C rise Storage (L) 1hr 2hr 3hr 6hr
50L Models
D15014 1 1500 400 1900 3400 4900 9400
32L Models
D13213 1 960 315 1275 2235 3195 6075
28L Models
D12813 1 840 315 1155 1995 2835 5355
12
32L INDOOR & OUTDOOR
FLUEING & DIMENSIONS
32L TWIN FLUEING OPTIONS
500mm
(VIEW FROM TOP)
min
ROOF TERMINAL
FOR 32L HEATER
464 240 Dux PART NUMBER:
99 CF32C001
70
135
1585mm
60
109
FLUE ADAPTOR
615
GAS INLE
586
TWIN TO COAX
HOT WATER Dux PART
NUMBER: CF32C002 COLD WATE
OUTLET (R3/4)
45 ELBOW FOR 32L HEATER
Dux PART NUMBER: CF32T002
DRAIN OUTLET 214
(R1/2) FLUE EXTENSION FOR 32L
362Dux PART NUMBERS: 1m
HEATER
VERSION
(CAN BE CUT) : CF32T004
CF32C005
171
min
90 ELBOW FOR 32L 230mm
HEATER Dux PART min
NUMBER: CF32C003 230mm
60
109
Number of elbows 0 1 2 3
Max length meters 14 12 11 9
Installation must comply with AS/NZS 5601
99
70
135
171
615
586
60
109
GAS INLET(R3/4)
HOT WATER
OUTLET(R3/4) 214 COLD WATER
INLET (R3/4)
DRAIN 362
OUTLET(R1/2)
428
13
32L INDOOR & OUTDOOR
FLUEING ACCESSORIES
The Dux 32 is a room sealed system that uses a twin flue system.
One pipe allows exhaust gases to travel out of the continuous flow
heater, whilst the other pipe allows air in for combustion. The flue pipes
are constructed from Polypropylene (PP), ensuring they are lightweight
and easy to work with. PP pipes can be used on the 32 as it’s a
condensing unit with lower temperature exhaust gases.
(CAN BE CUT)
FLUE EXTENSION
CF32T004 ROOF TERMINAL
1.0M TWIN 100 CF32C001
(CAN BE CUT) COAX 100/150
620mm
14
28L INDOOR & OUTDOOR
FLUEING & DIMENSIONS
28L TWIN FLUEING OPTIONS
350
1275mm
280
241
FLUE EXTENSION FOR 28L HEATER
Dux PART NUMBERS:
36
0.5m VERSION (CAN BE CUT): CF28C005
1m VERSION (CANNOT BE CUT) : CF28C006
199
125
79
45 ELBOW FOR
28L HEATER
Dux PART
NUMBER:
215
CF28C004
600
567
HOT WATER
OUTLET(R3/4) COLD WATER INLET(R3/4)
64.8
GAS INLET(R3/4)
90 ELBOW FOR 28L 262
HEATER Dux PART NUMBER:
CF28C003
WALL BRACKET
Dux PART
NUMBER: CF28C007
(VIEW FROM TOP)
241
min
200mm
HOT WATER
OUTLET (R3/4) COLD WATER INLET (R3/4)
775mm
262 GAS INLET (R3/4)
Number of elbows 0 1 2 3 4 5 6
Max length meters 13 11 9 7 5 4 2
Installation must comply with AS/NZS 5601
350 240
(VIEW FROM TOP)
241
36
97
171
50
600
567
HOT WATER
OUTLET (R3/4) COLD WATER INLET (R3/4)
15
28L INDOOR & OUTDOOR
FLUEING ACCESSORIES
The Dux 28 Indoor model is designed as a room sealed system that uses
a coaxial flue. The flue is made up of a durable, stainless steel inner pipe
which carries exhaust gases out of the continuous flow heater to the
outdoor atmosphere, whilst the white powder coated steel outer pipe
draws air in for combustion.
1275mm
m
775m
ELBOW 90º
CF28C003
COAX 90º 80/125
FLUE EXTENSION
CF28C005
0.5M COAX 80/125
(CAN BE CUT)
NOTE BE AWARE that you may have to adjust the dipswitches inside the
Dux commercial continuous water heater to achieve the specified system performance, depending
flow products are certified for on the total length of the flue pipe. Refer to the installation instructions
use with these flue components for maximum flue lengths, and dipswitch settings.
and accessories ONLY.
16
INDOOR & OUTDOOR SPECIFICATIONS
MODEL 50L Outdoor 32L Outdoor 32L Indoor 28L Outdoor 28L Indoor
50L Outdoor 32L Outdoor 32L Internal 28L Outdoor 28L Internal
NG - 50ECR6N NG - 32ECR6N NG - 32FCR6N NG - 28ENR6N NG - 28FNR6N
Product Codes 50L Outdoor 32L Outdoor 32L Internal 28L Outdoor 28L Internal
LPG - 50ECR6L LPG - 32ECR6L LPG - 32FCR6L LPG - 28ENR6L LPG - 28FNR6L
Water Pressure (kPa) 200 -800 200 -1,000 200 -1,000 200 -1,000 200 -1,000
Dimensions H X W X D (mm) 830 x 480 x 370 615 X 464 X 240 615 X 464 X 240 600 X 350 X 240 600 X 350 X 280
Weight (kg) 50 32 32 26 26
Water Inlet R1 (25mm) R 3/4 (20mm) R 3/4 (20mm) R 3/4 (20mm) R 3/4 (20mm)
Hot Water
R1 (25mm) R 3/4 (20mm) R 3/4 (20mm) R 3/4 (20mm) R 3/4 (20mm)
Connection Outlet
Sizes
Gas Inlet R 3/4 (20mm) R 3/4 (20mm) R 3/4 (20mm) R 3/4 (20mm) R 3/4 (20mm)
230 - 240 VAC 230 - 240 VAC 230 - 240 VAC 230 - 240 VAC 230 - 240 VAC
Supply
(50Hz) (50Hz) (50Hz) (50Hz) (50Hz)
Power Supply Operation 83 Operation 75 Operation 75 Operation 75 Operation 75
Consumption
Freeze Prevention Freeze Prevention Freeze Prevention Freeze Prevention Freeze Prevention
(W) 288 223 223 193 193
NG (kPa) 1.13 - 3.00 1.13 - 3.00 1.13 - 3.00 1.13 - 3.00 1.13 - 3.00
Gas Pressure
ULPG (kPa) 2.75 - 3.50 2.75 - 3.50 2.75 - 3.50 2.75 - 3.50 2.75 - 3.50
Temperature Dipswitch 55, 60, 75, 85 55, 60, 75, 85 55, 60, 75, 85 55, 60, 75, 85 55, 60, 75, 85
Range
pre-set 60 Controller 37 - 85 37 - 85 37 - 85 37 - 85 37 - 85
Thermal efficiency as tested with 15°C inlet water temperature and 60°C hot water outlet temperature at maximum burn capacity.
^
PERFORMANCE DATA
MODEL 50L Outdoor 32L Outdoor 32L Indoor 28L Outdoor 28L Indoor 5
Max 50 42 42 37 37
20oC rise 50 40 40 35 35
25oC rise 50 32 32 28 28
35oC rise 36 23 23 20 20
FLOW RATE L/min
50oC rise 25 16 16 14 14
60oC rise 21 13 13 12 12
70oC rise 18 11 11 10 10
17
TANK MANIFOLD SYSTEM DIMENSIONS
DIMENSION 'A' (mm) B: WALL MOUNT SYSTEMS
QTY OF
UNITS
28L 32L & 50L VERSION DIMENSION 'B'
3 UNIT
900 1170 1540 28L INDOOR 335
28L & 32L: 1540
50L: 1730 4 UNIT 1588 2080 32L OUTDOOR 310
FOR SINGLE
SIDE AND 5 UNIT 1964 2580 32L INDOOR 295
BACK TO BACK
SYSTEMS
6 UNIT 2340 3080 50L OUTDOOR 420
32L
28L & 32L: 1500 CRATED UNCRATED Model 50L
COLD WATER-210 /28l
50L: 1690
VERSION Frame Frame
FOR WALL Frame Frame GAS 50 40
MOUNT HOT WATER-405 Inc. Inc.
SYSTEM Only Only
Heater Heater COLD 50 40
2 X 28L 110 160 40 90
HOT 50 40
3 X 28L 125 200 45 120
18
COMMERCIAL ACCESSORIES
Unions H0256
WARRANTY
Full Warranty terms and conditions are in the product’s Owners Manual,
** Thermal efficiency tested to AS 4552-2005
© Dux Manufacturing Limited ABN 19 077 879 844. Lackey Rd, PO Box 209 Moss Vale, NSW 2577. The information supplied was
correct at time of printing. Specification and materials may change without notice. ® and ™ Trademarks of Dux Manufacturing Limited.
JUL19