ETABS 17.0.

1 License #

Pushover Curve - FEMA 440 Equivalent Linearization


Summary Description
This is the data for a FEMA 440 equivalent linearization pushover analysis.

General Input Data

Name Pushover5

Load Case push x Plot Type FEMA 440 EL

Demand Spectrum Input Data

Source ASCE 7-10 General Ss 0.09

Site Class D S1 0.036

Tl 8 sec

Effective Period and Effective Damping Parameters

Inherent Damping 0.05

Damping Params Default Value Period Parameters Default Value

A 4.2 G 0.11

B -0.83 H -0.018

C 10 I 0.09

D 1.6 J 0.14

E 22 K 0.77

F 0.4 L 0.05

Pushover Plot

ASSINMENT 1.EDB Page 1 of 2 1/4/2020


ETABS 17.0.1 License #

Plot Items

Demand Spectra Ductility Ratios 1; 1.5; 2; 2.5

Constant Period Lines 0.5; 1; 1.5; 2

Performance Point

Point Found Yes T secant 0.451 sec

Shear 632.0578 kN T effective 0.457 sec

Displacement -11.513 mm Ductility Ratio 1.109352

Sa 0.14486 Effective Damping 0.0545

Sd 7.4 mm Modification Factor 1.025299

Tabulated Plot Coordinates

Capacity Curve Coordinates


Sd Sa Period
mm g sec
0 0 0.448
6.671 0.13373 0.448
14.264 0.249582 0.48
25.474 0.321966 0.564
27.827 0.307391 0.604
29.44 0.318843 0.61