Download as pdf or txt
Download as pdf or txt
You are on page 1of 28

Wastewater Pump Products

EBARA Fluid Handling Division EngineeredforPerformance


EBARA water and wastewater pumps
are an integral part within the
wastewater treatment process and
cycle of cleaning our used water.
Why Treat Wastewater?
Water scarcity is among the most serious crises facing the world. It is under
constant threat due to climate change, explosive population growth and
waste. Even though the world is two-thirds water, most of it is not potable.

The world’s supply of fresh water is slowly running dry. Forty percent of
the world’s population is already reeling under today’s water crisis: an issue
of both scarcity and access. The growing water shortage will make food
scarcer, potable water less accessible and water-borne diseases even
more rampant. Currently, one in eight people do not have access to safe
drinking water; almost three times the population of the United States.
3.575 million people die each year from water borne illness, both caused
by lack of wastewater treatment and sanitation; the world’s largest cause
of infection. The number of people expected to suffer under these circum-
stances is predictedted to reach more than 500 million by the year 2025.

Over the past decade, the United States has been plagued by horrific
flooding and drought caused by less predicatable geographically interde-
pendent weather patterns and long periods of record high temperatures,
large snowfalls/melts and persistent rains. The severe swings in weather
conditions have been close together and drastic.

Recycling Our “Used” Water


With water scarcity increasing, the continued unpredictability of volatile
weather patterns and constraints in federal funding for municipality infra-
structure, the need to recycle and reuse our water is an abundantly clear
necessity. One of the most promising efforts to stem the global water crisis
is industrial and municipal water recycling – the reuse of treated waste-
water for beneficial purposes such as agricultural and landscape irrigation,
industrial processes, toilet flushing, or replenishing a groundwater basin.

Wastewater is water that comes from homes, businesses and industries


that includes substances such as run-off, human waste, food scraps, oils,
soaps and chemicals from the water from sinks, showers, bathtubs, toilets,
washing machines and dishwashers. Wastewater also includes storm
runoff that contains harmful substances that wash off roads, parking lots
and rooftops that can harm our rivers and lakes
and cannot not be used without some treatment.

Wastewater treatment is a multi-stage process


to renovate wastewater before it re-enters a body
of water, is applied to the land or is reused. As
the world endures major water challenges,
EBARA is committed to engineering and
producing water and wastewater pumps and
products integral to the wastewater reclamation,
treatment and recycling processes.
3
EBARA products: Engineered for Performance.

Founded in 1912, EBARA Corporation is recognized as a world leader in


the design, development and manufacture of industrial machinery with a
predominant focus on the production of pumps, pumping systems and
compressors for a wide range of applications. EBARA Corporation now
operates 77 subsidiaries and 11 affiliate companies in 14 countries under
three principal business groups: Fluid Machinery and Systems, Environmental
Engineering and Precision Machinery.

The variety of pump types and sizes produced by the EBARA Fluid Machinery
and Systems Group is tremendous, ranging from fractional horsepower
recirculation pumps to vertical mixed flow pumps with horsepower’s into
the thousands. EBARA’s engineering and manufacturing capabilities are
best demonstrated by the Futtsu manufacturing plant. The plant is focused
on the production of high pressure, large scale pumps and systems targeting
Overall view of the Futtsu Plant
specific applications in oil and gas, nuclear power, water and wastewater
infrastructure industries. EBARA’s Fujisawa plant is one of the most
technologically advanced manufacturing plants for the mass production of
small size pumps; including the D-series of cast iron pumps.

EBARA Fluid Handling (FHD), the US sales and service subsidiary, provides
engineered pump, pump products and related services for the water, waste-
water, commercial, municipal, energy and power industries offering reliable
product knowledge, application expertise and responsive support including
aftermarket replacement parts services.

Recognizing the continued strain on


water and wastewater facilities and
infrastructures with increased maintenance,
energy, and environmental demands and
costs, EBARA Fluid Handling strives to
deploy the best water and wastewater
pumps, pump products, and technologies
to meet these requirements.

4
With horsepower ranges up to 500 HP and capacities to 35,000 GPM,
EBARA FHD’s cast iron submersible pumps meet a wide range of industrial,
municipal, flood control, and residential water and wastewater applications.
The cast iron line of pumps includes submersible sewage, submersible
sump, semi-vortex, vortex, grinder, non-clog, and dry pit models.

EBARA Fluid Handling completed a 36,000 square foot expansion of its


Rock Hill facilities in 2009, doubling its size and allowing larger pumps and
products to be built, tested and shipped from the South Carolina location.
The Rock Hill facility includes a new 81,000 gallon computer-aided testing
area capable of handling large-scale pump models in both wet and dry pit
configurations up to 350 HP. The expanded facility houses a large, state-
of-the-art training facility to accommodate pump product training services
with access to amenities such as guest offices and facility services.

EBARA Fluid Handling maintains inventory that allows it to assemble, test,


and ship ½ to 150 HP cast iron submersible pumps in 5 to 14 working days,
and offer quick shipments of other standard product lines as well.

EBARA service and parts are available through an extensive service network
throughout North America to assist customers in replacement of parts or
complete pumps and motors.

5
EBARA products: designed for performance.
Ebara Flow Head Discharge Maximum Type of
Model Description (GPM) (feet) HP Size (inches) Temp Pumpage
EPD, Optima
High quality stainless steel 3 to 86 9 to 61 1
/3 to 11/2 11/4 to 11/2 122°F / 50°C water, semi-
submersible sump and dirty water;
drainage pump solids to 3/8"

DWU, DWXU
water,
High quality stainless steel
8 to 235 8 to 74 1
/2 to 3 2 104°F / 40°C wastewater;
submersible sump and solids to 2"
effluent pump

DSU, DSHU
Durable cast iron submersible 8 to 390 8 to 126 1
/2 to 10 2, 3, 4 122°F / 50°C (hot) water,
sump, drainage pump up to wastewater,
176°F / 80° C treated sewage
(hot) water,
DVSU, DVSHU wastewater,
Durable cast iron submersible 7 to 250 10 to 80 1
/2 to 5 2, 3 122°F / 50°C abrasive,
pump with semi-vortex up to
suspended
impeller 176°F / 80° C solids to 21/4"

DWP, DWPM severe


Portable, slim-line top discharge 30 to 2000 5 to 340 1.3 to 58 2, 3, 4, 6, 8 104°F / 40°C corrosive,
submersible dewatering pumps contaminated,
abrasive fluids
DMLEU water,
Durable cast iron submersible 55 to 1345 12 to 136 3 to 30 3, 4, 6 104°F / 40°C wastewater,
non-clog, single channel impeller effluent;
pump solids to 3"

EFQT, EFQU water,


Self-priming trash pump; large range to 3400 to 210 1 to 125 2 to 12 — wastewater,
of sizes with the ability to handle sewage, slurry;
solids and light slurries effectively solids to 11/4", 3"
DGUII, DGFU
Submersible grinder pump with heavy water,
duty high chrome iron grinder system 5 to 80 27 to 148 2 to 5 11/4, 2 104°F / 40°C wastewater,
reduce solid sizes for smooth, non- sewage,
clogging flow. solids to 3"
wastewater,
DLU
sewage,
Durable cast iron submersible pump 13 to 430 9 to 66 1 to 5 2, 3, 4 104°F / 40°C stringy, abrasive
with semi-open impellers with large
materials
wear area and open passageways
solids to 3"
DVU: wastewater,
DVU, DVFU 16 to 430 10 to 50 1 to 5 2, 3, 4 sewage,
Durable cast iron submersible 104°F / 40°C
abrasive,
pump with vortex impeller large DVFU:
suspended
solids handling capabilities 16 to 1200 13 to 121 2 to 30 2, 3, 4, 6 solids to 4", 5"
DLFU, DDLFU DLFU: water,
Cast iron submersible pump with 13 to 4000 7 to 243 2 to 60 2 to 12 104°F / 40°C wastewater,
high efficiency impeller and large sewage,
DDLFU (dry pit):
solids handling capabilities; dry fibrous
and wet pit configurations 80 to 4000 20 to 243 15 to 60 4 to 12 solids to 31/4"
DSC4, DSCA4, DSC wastewater,
Large cast iron submersible pump 530 to 35000 sewage,
8 to 300 40 to 500 6 to 24 104°F / 40°C stringy, abrasive
available with semi-open or enclosed
impellers with large passageways, materials
dry and wet pit configurations solids to 81/8"
6
applications

Page No.
Construction

Flood control
Commercial

Wastewater
Residential

Municipal

Industrial

Drainage

Irrigation

Transfer
Sewage
Effluent
Water

Sump
n n n n n n n n n 8

n n n n n n n n n n n 9

n n n n n n n n n 10

n n n n n n n n n 11

n n n n n n n n 12

n n n n n n n n n 13

n n n n n n n 14

n n n n n n n n n 16

n n n n n n n 17

n n n n n n n n n 18

n n n n n n n n n n 20

n n n n n n n n 24

7
Model EPD, Optima submersible stainless steel sump, drainage

Standard Specifications
Automatic Manual
Design Discharge 1
/3 HP - 11/4" 1/3 HP - 11/4"
1/2 HP and 3/4 HP - 11/2" 1/2 HP through 11/2 HP - 11/2"

Horsepower 1 1 3
/3, /2, and /4 HP 1/3, 1/2, 3/4, 1, and 11/2 HP

Capacity 2.7 to 72 GPM 2.7 to 86 GPM


Total head 9.3 to 57 feet 9.3 to 61 feet
Max. Liquid temp. 122°F/50°C (140°F/60°C intermittent duty)
Solids 3/8" Spherical (2% by concentration)

Speed 3600 RPM


Materials Casing 304L Stainless Steel
Impeller 304L Stainless Steel*
Features Shaft 303 Stainless Steel

High quality stainless steel (Note: Optima has Noryl Motor Frame 304L Stainless Steel
Fastener 304L Stainless Steel
impeller)
Construction Shaft Seal (Double)**

Single and three phase models available Material – Upper NBR Fitted Carbon/Ceramic - 1/2, 3/4, 1, and 11/2 HP

Air-filled, continuous duty rated, permanent split capacitor Material – Lower FPM Fitted Silicon Carbide/Silicon Carbide - 1/2, 3/4, 1, and 11/2 HP
Impeller Type Semi-Open
motors Bearing Sealed Ball Bearing

Built-in thermal protection with automatic reset Motor Air-filled, Insulation Class F, 2 Pole, Rated Continuous
Duty–Permanent Split Capacitor

Built to operate whether fully or partially submerged Single Phase 115 V 115 V

Oil lubricated double mechanical shaft seal 1/2 - 11/2 HP Three Phase 230V or 460V
Motor Protection† Built-in Motor Protection with Auto Reset
models
Power Cord Single Phase UL/CSA SJTOW-A with ECS No. 250 cap plug with grounding

20' UL/CSA approved, water resistant #16 AWG cord pin – 20 Ft. Length Rated 15 Amp 125V – NEMA 5-15P

Optima and EPD slimline automatic models can operate in Three Phase UL/CSA STOW-A water resistant,
stripped end jacket removed
a 12" diameter basin or 8" x 8" square basin 2" and conductor stripped
5/8"– 20 Ft. length

Automatic Float Switch Mechanical Float


*Note: UL and CSA listed; Model Optima UL certified only.
Notes: * ITEM NO. Optima-3AS1, Optima-3MS1 – Impeller material is Thermo Plastic-Noryl GFN2
** Optima-3 & EPD-3 – 1/3 HP Shaft Seal is single mechanical seal (lower side) and 1 lip seal (upper side)
– Mechanical Seal material: Carbon/Ceramic/FPM
† Three Phase models require user to provide motor protection

EPD, Optima selection chart


70

60

50

40
Head ( )

30

20

10

0
0 10 20 30 40 50 60 70 80 90 100
Flow (gpm)
8
Model DWU, DWXU submersible stainless steel sump, effluent

Standard Specifications
Automatic Manual
Design Discharge 2'' NPT or 2'' ANSI Flanged
Horsepower 1/2 HP to 11/2 HP 1
/2 HP to 3 HP
Capacity 8 to 180 GPM 8 to 235 GPM
Total head 8 to 54 feet 8 to 74 feet
Max. Liquid temp. 104°F (40°C)
Solids 2" Spherical
Speed 3600 RPM
Materials Casing 304L Stainless Steel

Features Impeller
Shaft
304L Stainless Steel
304L Stainless Steel

Constructed of high-quality, corrosion resistant 304 Motor Frame 304L Stainless Steel
stainless steel Fastener 304L Stainless Steel

Single and three phase models available Construction Mechanical Seal Double Mechanical Seal
Material – Upper Carbon/Ceramic/NBR

Motor is 2 pole submersible, rated continuous duty Material – Lower Silicon Carbide/Silicon Carbide/FPM

Class F motor insulation Impeller Type Single Channel/Vortex

104°F maximum fluid temperature continuous operation, Bearing Sealed Ball Bearing
Motor Air-filled, Insulation Class F
fully submerged; 140° F intermittent operation Single Phase 115 V (1/2, - 1HP) 115 V (1/2, 1HP), 230V

Automatic and manual operation 230V (1/2, - 11/2HP)

Auto float switch is mechanical/non-mercury Three Phase 230V or 460V

NPT thread discharge or 150 lb ANSI flange Motor Protection† Built-in Overload Protection (Single phase models)

Double mechanical seal with viton elastomers Submersible Cable 25 ft.
Consult factory for additional cable lengths.

Shielded, prelubricated ball bearings

Single channel and vortex impellers Accessories QDC System

Thermal overload protection Notes: * 2HP, 1-phase and 3HP, 3-phase units have a cast iron intermediate bracket.

QDC system available as an optional accessory
*Note: Model DW(A)(F)U, DWX(A)(F)U is listed by the Canadian
Standards Association (CSA) as certified (3HP excluded).

DWU, DWXU selection chart


m ft m ft
24.4 80 24.4 80

21.3 70 21.3 70

18.3 60 18.3 60

50D
50D WU6
15.3 50 WF 2.2
U6
2.2 3HP 15.2 50 50DW
3H 50DW XU62.2
TOTAL HEAD

50D P (manua XFU6 3HP


(3 p 2.2 3
W
50D U6 has l opera HP (ma
eo nu
WF 1.5 nly) tion) (3 p al ope
TOTAL HEAD

hase ra
12.2 40 U6 2 H only tion)
50D 1.5 P 12.2 40 50DW
)
2 HP (ma
50D W(A)U nua 50DW XU61.5 2
WF X FU 6 H
(A)U61.1 1
l op
50D
era
tion 1.5 2 P (m
61.1 ½HP only HP anua
9.1 30 50D W(A)U 1½ ) 50DW l oper
ation
WF HP 50DW X(A)U61.1
(A)U6.75 1 9.1 30 only
)
XF(A
6.7 HP
5 1 )U61 1½HP
.1 1½
HP HP
50DW
6.1 20 50DW X(A )U
6.1 20 XF(A 6.75 1H
50DW(A)U6.4 ½HP )U6.7 P
5 1H
50DWF(A)U6.4 ½HP P

3.1 10
3.1 10
50DWX(A)U6.4 ½HP
50DWXF(A)U6.4 ½HP

0 0
0 50 100 150 200 250 US GPM 0 0
m3/min 0 25 50 75 100 125 150 175 200 225 US GPM
0 .19 .38 .56 .75 .95
m3/min
CAPACITY 0 .1 .19 .28 .38 .47 .56 .66 .75 .85
CAPACITY

9
Model DSU, DSHU submersible cast iron sump

Standard Specifications
DSU DSHU (Hot Water pumps)
Design Discharge 2, 3, 4 inch 2, 3 inch
Horsepower 3 to 10HP 1/2 to 5HP

Capacity 8 to 390 GPM 8 to 250 GPM


Total head 10 to 126 feet 8 to 126 feet
Max. Liquid temp. 122°F/50°C 158°F/70°C - 1/2, 1HP
176°F/80°C - 2 to 5HP
200°F/93°C - limited to 10 minutes
Speed 3600 RPM
Materials Casing Cast Iron
Impeller Ductile Iron Cast Iron (1/2 to 2HP)
Features Ductile Iron (3, 5HP)
 Air-filled, heavy duty motor, rated for 20 starts/hour, dissipates heat Shaft 403 Stainless Steel
easily, operates cooler with higher efficiencies; longer service life Motor Frame Cast Iron
with lower operating costs Fastener 304 Stainless Steel

Built-in autocut motor protection safeguards motor against overheat, Construction Mechanical Seal Double Mechanical Seal
Material – Upper Carbon/Ceramic Silicon Carbide/Silicon Carbide
out of phase, single phasing and no load; saves money on costly Material – Lower Silicon Carbide/Silicon Carbide Silicon Carbide/Silicon Carbide
motor replacement Impeller Type Semi-open
 60,000 hour bearings ensure long dependable operation; lower Bearing Prelubricated Ball Bearing
maintenance costs Motor Air-filled, Insulation Class H (1/2, 1HP)

Semi-open impellers offer the best design for handling stringy and/or Class F Class F (2, 3, 5HP)
abrasive materials due to the large wear area and open passageways; Three Phase 208/230V/460V 208/230V, 460V - Single voltage
provide durability and longer life Motor Protection Built-in Auto Cut - overload Built-in Overload Protection
out of phase, single phasing
 Double mechanical seals – silicon carbide lower seals, carbon/ceramic protection
upper - hard faced upper and lower seals operate in an oil bath providing Submersible Cable 33 ft. standard cable length, Optional 66 ft.
longer service life and lower maintenance costs
Accessories Cast Iron discharge Cast iron companion flange

Small and light weight portability; easy to transport for temporary elbow (3 to 5HP) with NPT thread (1/2 to 2HP)
installations Optional QDC System
 Available for slide rail installations provides ease of maintenance for
small sump type installations

DSU, DSHU selection chart


m ft. 60 Hz (Synchronous Speed: 3600 RPM)
150
DSU-SC6-8412

40
50DSU/DSHU63.7 5HP 100DS
30 100 U67.5 1
0HP
50DSU/50DSHU62.2 3 HP 10
80 0D
50DSHU61.5 2HP SU
20 65
60 .5
7!
50DSHU6.75 1HP
80D

HP
15 50
SU
/80
Total Head

40
DS
HU

10 50DSHU6.4 !HP
63.

30
80D SHU62 P

75
80D

8
SU/

HP

6 20
3H
.2

5
15
4

3 10

8
6 8 10 15 20 30 40 50 60 80 100 150 200 300 400 US GPM

.03 .04 .05 .06 .08 .10 .15 .20 .30 .40 .50 .80 1.0 1.5 m3/min.

Capacity
10
Model DVSU, DVSHU submersible cast iron semi-open vortex sewage

Standard Specifications
DVSU DVSHU (Hot Water pumps)
Design Discharge 3 inch 2, 3 inch
Horsepower 3 to 5HP 1/2 to 5HP

Capacity 29 to 240 GPM 5 to 240 GPM


Total head 20 to 80 feet 10 to 75 feet
Max. Liquid temp. 122°F/50°C 158°F/70°C - 1/2, 1HP
176°F/80°C - 2 to 5HP
200°F/93°C - limited to 10 minutes
Speed 3600 RPM
Materials Casing Cast Iron
Impeller Cast Iron (1/2 to 2HP)
Features Shaft 403 Stainless Steel
 Air-filled, heavy duty motor, rated for 20 starts/hour, dissipates heat Motor Frame Cast Iron
easily, operates cooler with higher efficiencies; longer service life Fastener 304 Stainless Steel
with lower operating costs Construction Mechanical Seal Double Mechanical Seal
Material – Upper Carbon/Ceramic Silicon Carbide/Silicon Carbide

Built-in motor protection autocut protects motor against overheat, Material – Lower Silicon Carbide/Silicon Carbide Silicon Carbide/Silicon Carbide
out of phase, single phasing and no load; saves money on costly Impeller Type Semi-open vortex
motor replacement Bearing Prelubricated Ball Bearing
 60,000 hour bearings ensure long dependable operation; lower Motor Air-filled, Insulation
maintenance costs Insulation Class F Insulation Class H (1/2, 1, 2 HP)
Three Phase 208/230V, 460V Class F (3, 5HP)

Large solids handling capabilities prevents clogging
Motor Protection Built-in Auto Cut - overload Built-in Overload Protection

Semi-open vortex type recessed impeller; vortex action prevents clogging out of phase, single phasing
and handles stringy material better, high reliability, and lowers protection
maintenance costs Submersible Cable 33 ft. standard cable length, Optional 66 ft.

Double mechanical seals – silicon carbide lower seals, carbon/ceramic
upper - hard faced upper and lower seals operate in an oil bath away Accessories Cast Iron discharge elbow Cast Iron discharge elbow
(3 to 5HP) (3" 1 to 5HP)
from pumpage providing longer service life and lower maintenance costs Cast iron companion flange
 Available for slide rail installations provides ease of maintenance for with NPT thread (2", 1/2 to 2HP)
small sump type installations Optional QDC System

DVSU, DVSHU selection chart


m ft.
60 Hz (Synchronus Speed: 3600 RPM)
30 100
DVSU(S)-SC6-9101

80 80DV
20 80DVSSHU63.7
60 50DVS U 5HP
HU61 80D
50 .5 2H
15 P VS
HU
50DVS 62.
80

40
Total Head

HU6.7 23
DV

10
5 1HP HP
S

80D
HU

30
80D

VS
U
61

8
VSH

.5
2H

20
U6.

6
P

50DVSHU6.4 1/2HP
75

5
15
1HP

10
3

5 6 8 10 15 20 30 40 50 60 80 100 150 200 300 USGPM


.02 .03 .04 .05 .06 .08 .1 .15 .2 .3 .4 .5 .8 1.0 m 3/min.

Capacity
11
Model DWP, DWPM submersible dewatering

Standard Specifications
Standard construction Stainless Steel
Design Discharge 2, 3, 4, 6, 8 inch
Horsepower 1.3 to 58HP
Capacity 30 to 2000 GPM
Total head 5 to 34 feet
Max. Liquid temp. 104°F/40°C
Materials Inner casing
1.3 to 58 HP Epoxy coated aluminum 316 SS
58HP DWPM Cast iron 316 SS
Outer casing
1.3 to 10 HP Epoxy coated aluminum 316 SS
Features 16 to 58 HP Epoxy coated carbon steel 316 SS

Heavy duty motor 58HP DWPM Cast iron 316 SS
Shaft 431 SS
· Oversized shaft and bearings
Impeller
· Available in most voltage / frequency combination Open mixed flow 410 SS (optional 316SS)
· 2- pole squirrel cage induction type continuous rated, Class H insulation Diffuser/Wearplate Nitrile rubber coated
· Maximum 15 starts per hour Strainer 304 SS 316 SS

Tandem UPPER & LOWER mechanical seals operate enclosed in a Impeller nut 410 SS
pressure compensated oil chamber Mechanical Seal Tandem Mechanical Seal

Unique SAND GUARD seal housing prevents sand/debris from Material – Upper Tungsten Carbide/ Upper seal is lip seal only,
collecting on outer seal face during pump operation Tungsten Carbide for 1.3 - 2 HP models

Standard sacrificial zinc anodes provide protection from galvanic corrosion Material – Lower Tungsten Carbide/

Cable sealing system seals power cord AND individual leads in the Tungsten Carbide
gland assembly Bearing

SS impeller, shaft, strainer, hardware and outlet for maximum corrosion Upper Single row deep groove with high temperature grease
containing special anti-corrosion additive
resistance Lower

Standard impeller is nitride hardened 410 stainless steel to 56HRC; 1.3 to 10 HP Single row deep groove with high temperature grease
optional 316SS impeller available containing special anti-corrosion additive

Field adjustable rubber lined diffuser and wear plates provide for 16 to 58 HP Double angular contact lower bearings; enclosed with high
optimum pump efficiency temperature grease containing special anti-corrosion additive

Disch.
DWP, DWPM selection chart / Dimensions Curve Model NPT T U
350 A 50DWP 1.3HP 2 12-1/4 6-1/4
B 50DWPM 1.5HP 2 12-1/4 6-1/4
325 C 50DWP 2HP 2 13-1/2 6-1/4
300
D 50DWPM 2HP 2 13-1/2 6-1/4
E 80DWP 3HP 3 26-1/4 7-1/2
275 F 80DWP 5HP 3 28-1/2 7-1/2
T G 80DWPM 5HP* 3 28-1/2 10-3/4
250
H 100DWP 7.5HP 4 28-1/2 10-3/4
225 I 80DWPM 10HP* 3 29-1/2 10-3/4
J 100DWP 10HP 4 29-1/2 10-3/4
200
K K 100DWPM 16HP 4 33-1/4 14-1/4
Head (ft)

M
175 L 150DWP 16HP 6 33-1/4 14-1/4
I R
M 100DWPM 25HP 4 36 15-3/4
150 O N 150DWP 25HP 6 36 15-3/4
G U
125 O 150DWPM 35HP 6 40-1/2 15-3/4
P 200DWP 35HP 8 40-1/2 15-3/4
100 R 150DWPM 58HP 6 41-1/2 17-1/8
75
S 200DWP 58HP 8 41-1/2 15-3/4
N S * 2-stage pumps
B
D 50 P
A F J L
25
E H
C
0
0 200 400 600 800 1000 1200 1400 1600 1800 2000
Flow (gpm)
12
Model DMLEU submersible single channel sewage

Standard Specifications
Design Discharge 3, 4, 6 inch
Horsepower 3 to 30HP
Capacity 55 to 1345 GPM
Total head 12 to 136 feet
Max. Liquid temp. 104°F/40°C
Speed 1800 RPM
Materials Casing Cast Iron
Impeller Cast Iron
Shaft 403 Stainless Steel
Features Motor Frame
Fastener
Cast Iron
304 Stainless Steel
 Economical alternative – commercial/industrial use
Construction Mechanical Seal
 Non-clog, single channel impeller has 3'' spherical passage; prevents
Double Mechanical Seal
clogging; high efficiency and saves energy
Material – Upper Carbon/Ceramic

Robust construction – large diameter, short overhang shaft with Material – Lower Silicon Carbide/Silicon Carbide
stainless steel fasteners Impeller Type Non-clog single channel enclosed
 Air-filled, Class F insulated, heavy duty motor, rated for 20 starts/hour, Bearing Prelubricated Ball Bearing
dissipates heat easily, operates cooler with higher efficiencies; longer Motor Air-filled, dry submersible, Class F Insulation
service life with lower operating costs Three Phase 208/230V, 460V

Built in motor protection autocut protects motor against overheat, Service Factor 1.15
out of phase, single phasing, and no load; saves money on costly Motor Protection Built-in Auto cut (3HP model)
motor replacement Thermal Detector – Klixons
 60,000 hour bearings ensure long dependable operation; lower Mechanical seal leak detector – internal oil probe
maintenance costs

Double mechanical seals – silicon carbide lower seals, carbon/ceramic Submersible Cable 33 ft. standard cable length, Optional 66 ft.
upper - hard faced upper and lower seals operate in an oil bath; providing
Accessories Optional QDC System
longer service life and lower maintenance costs
 Available for slide rail installations provides ease of maintenance for
small sump type installations

DMLEU selection chart


m ft. 60 Hz (Synchronus Speed: 1800 RPM)
50
40 140
120 80DMLE622
30 100 80DMLE615
90 100DMLE622
80 80DMLE611
100DM
20 70 80DMLE67.5 LE615
60
15
0D

80DMLE65.5 100DMLE611
Total Head

50
ML
E6
15

22
0D

100
40 DM
ML

LE6
E6

80DMLE63.7 7.5
15

10 100D
15

9 30 MLE
0D

65.5
ML

8
E6
150

7
11
DM

6 20
LE6
150

80DMLE62.2 100DMLE63.7
7.5
DM

5
LE6
5.5

4
3 10

2
50 100 200 300 400 500 600 800 1000 1400 2000 USGPM

0.1 0.2 0.3 0.4 0.5 1.0 2 3 4 5 6 7 8 9 10 m 3/min.


Capacity
13
Model EFQT, EFQU self-priming trash pump

Standard Specifications
EFQT EFQU
Design Discharge 2 to 12 inch 3 to 6 inch
125# R.F. ANSI 125# R.F. ANSI
Horsepower 1 to 125 HP 11/2 to 75HP
Performance Capacity to 3400 GPM to 1500 GPM
Total head to 130 feet to 210 feet
Maximum Solid Diameter 3 inch 1.25 inch
Speed 650 to 2150 RPM
Standard Materials
Casing Cast Iron A48 CL 30
Features Impeller
Wear Plate
Ductile iron A 60-40-18
Carbon Steel SAE 1020
 Large solids handling capabilities prevents clogging – 3" solids ( EFQT), Cover Plate Cast Iron A48 CL 30
1.25" solids (EFQU) Shaft Alloy Steel 4140

Easy maintenance – Removeable cover plates and rotating elements Bearing Housing Cast Iron A48 CL 30
Flap Valve Reinforced Neoprene
for quick inspection and cleaning of the pump without having to Seal Sleeve 316 Stainless Steel
remove it from the piping Flanges Cast Iron A48 CL 30

Backside pump-out vanes reduce pressure on the seal and exclude O-rings Buna
solids from the seal area Mechanical Seal Silicon Carbide/Silicon Carbide, Viton, 316 Stainless Steel

External shimless wear plate adjustment Options Tungsten Carbide Seals
Base-plate mounting, coupling guards

Multivane, semi-open, high efficiency impellers
Horizontal V -belt

Robust cast iron casing with ductile iron impeller standard. Vertical V- belt

Cartridge seals with Silicon Carbide/Silicon Carbide faces; design Flex coupled
allows for quick replacement and ease of installation TEFC or OPD motors
Diesel Engine operation, trailer or skid mounted

EFQU series pumps are dimensionally interchangeable with the
NPT Threaded suction and discharge connections
EFQT series pumps in the 3", 4" & 6" sizes
*Note: Alternate construction materials avialable on request including 304ss, 316ss and CD4 MCU

Diesel engine operation, trailer or skid mounted

EFQT selection chart EFQU selection chart


TDH TDH
m ft m ft
42 140 68 225

61 200
36 120

53 175

30 100

46 150

24 80 EFQU3 EFQU4 EFQU6


38 125

EFQT2 EFQT4 EFQT6 EFQT8 EFQT10


31 100
18 60 EFQT3 EFQT12

23 75

12 40

15 50

6 20
8 25

0 0 0 0
0 500 1000 1500 2000 2500 3000 3500 USGPM 0 300 600 900 1200 1500 1800 USGPM

0 113 227 340 454 568 681 795


3
m /hr 0 68 136 204 272 340 408 m3/hr

14
FlexCoupled self-priming trash pump
EBARA
Flex Coupled Control Panel
ControlPanel Di h
Discharge
AtmosphericPressure

Datum

Vent

High
Level
Alarm
4
Inlet Lag
Pump
On
3
Lead
P
Pump 2
On
Pump 1
Minimum Off
g
Submergence
Flare
OffBottomDistance

VerticalVͲBelt EBARA
Vertical V-Belt Control Panel
ControlPanel Di h
Discharge
AtmosphericPressure

Datum

Vent

High
Level
Alarm
4
Inlet Lag
Pump
On
3
Lead
P
Pump 2
On
Pump 1
Minimum Off
Submergence
g
Flare
OffBottomDistance

HorizontalVͲBelt EBARA
Horizontal V-Belt Control Panel
ControlPanel Discharge
i h
AtmosphericPressure

Datum
SpoolPiece
EasesCleanout
l
Maintenance

Vent

High
Level
Alarm
4
Inlet Lag
Pump
On
3
Lead
P
Pump 2
On
Pump 1
Minimum Off
Submergence
g
Flare
OffBottomDistance

15
Model DGUII, DGFU submersible grinder

Standard Specifications
DGUII DGFU
Design Discharge 11/4 inch 11/4, 2 inch
Horsepower 2HP (single phase) 2 to 5HP
Capacity 5 to 30 GPM 5 to 80 GPM
Total head 27 to 112 feet 27 to 148 feet
Max. Liquid temp. 104°F/40°C
Speed 3600 RPM
Materials Casing Cast Iron
Impeller Cast Iron
Grinder Impeller High Chrome Cast Iron HRC 60
Features Grinder Disk
Shaft
High Chrome Cast Iron HRC 60
403 Stainless Steel
 Heavy-duty high chrome iron grinder system – powerful blades Motor Frame Cast Iron
reduce solids size for smooth, non-clogging flow Fastener 304 Stainless Steel
 Reversible grinder ring provides longer service life and less Construction Mechanical Seal Double Mechanical Seal
maintenance Material – Upper Carbon/Ceramic

Air-filled, Class F insulated, heavy duty motor, rated for 20 starts/hour, Material – Lower Silicon Carbide/Silicon Carbide
dissipates heat easily, operates cooler with higher efficiencies; longer Impeller Type Semi-open vortex
service life with lower operating costs Bearing
 Built-in motor protection; (DGUII models) protects motor against over- Upper/Lower Prelubricated Ball Bearing
heating, out-of-phase, single phasing, and no load; (DGFU models) Motor Air-filled, Insulation Class F Insulation Class F
provide overtemp and seal fail protection; saving money on costly Optional: FM Explosion Proof
motor replacement Class 1, Division 1, Group C, D

60,000 hour bearings ensures long dependable operation; lower Single Phase 208/230V
maintenance costs Three Phase 208/230V/460V

Semi-open vortex type recessed impeller; vortex action prevents Motor Protection Built-in Auto Cut - overload Built-in Thermal Detector - Klixon
clogging and handles stringy material better vs moving pumpage no load, out of phase, and Built-in Mechanical Seal Leakage
through impeller vanes; provides durability, high reliability, and lowers single phasing protection
maintenance costs Submersible Cable 33 ft. standard cable length, Optional 66 ft.
 Double mechanical seals – upper and lower seals operate in an oil
bath; providing longer service life and lower maintenance costs Accessories Optional QDC System

Small and light weight portability; easy to transport for temporary
installations

DGUII, DGFU selection chart


m ft
50 160 60 Hz (Synchronus Speed: 3600 RPM)
DGUII (T)-SC6-9101

140
40
120
50DGFU63.7 5HP
30 100
Total Head

80
20
60 30DGFU61.5 2HP 50DGFU62.2 3HP
32DGUII61.5 2HP
40
10
20

0
0 10 20 30 40 50 60 70 80 90 USGPM
l/min.
0 100 200 300
Capacity
16
Model DLU submersible sewage

Standard Specifications
Design Discharge 2, 3, 4 inch
Horsepower 1 to 5HP, Single Phase
1 to 2 HP, Three Phase
Capacity 13 to 430 GPM
Total head 9 to 66 feet
Max. Liquid temp. 104°F/40°C
Speed 1800 RPM
Materials Casing Cast Iron
Impeller Cast Iron
Feature Shaft
Motor Frame
403 Stainless Steel
Cast Iron
 Air-filled, Class F insulated, heavy duty motor, rated for 20 starts/hour, Fastener 304 Stainless Steel
dissipates heat easily, operates cooler with higher efficiencies; longer Construction Mechanical Seal
service life with lower operating costs Double Mechanical Seal

Built-in motor protection with autocut protects motor against overheat, Material – Upper Carbon/Ceramic
out of phase, single phasing, and no load; saves money on costly Material – Lower Silicon Carbide/Silicon Carbide
motor replacement Impeller Type Semi-open
 60,000 hour bearings – long dependable operation with lower main- Bearing Prelubricated Ball Bearing
tenance costs Motor Air-filled, Insulation
Class F

Large solids handling capabilities prevents clogging
Single Phase 208/230V

Semi-open impellers; offer the best design for handling stringy and/or
Three Phase 208/230V, 460V
abrasive materials better due to large wear area and open passageways,
Service Factor 1.15
providing durability and longer life Motor Protection Built-in Auto cut - overload, out of phase,

Double mechanical seals – silicon carbide lower seals, carbon/ceramic single phasing protection
upper - hard faced upper and lower seals operate in an oil bath; providing
longer service life and lower maintenance costs Submersible Cable 33 ft. standard cable length, Optional 66 ft.
 Available for slide rail installations provides ease of maintenance for
Accessories Optional QDC System
small sump type installations

DLU selection chart


m ft. 60 Hz (Synchronus Speed: 1800 RPM)
20
60 80DLM
U63.7S
5HP
15 50 3
40 50DLU61.5 2HP
80DLU63.7S 5HP
10
30 10
Total Head

8 0D
2 1 LU
63
.7S
6 20 50DLU6.75 1HP 10 5H
0D
LU P
5 62
.2S
15 3H
4 100DLU61.5 2HP P

10
3 10 15 20 30 40 50 60 80 100 150 200 300 400 500 US GPM
m 3/min.
0.1 0.2 0.3 0.4 0.5 0.6 0.8 1.0 1.5 2.0
Capacity
1 80DLU62.2S 3HP
2 80DLMU61.5 2HP
3 80DLMU62.2S 3HP
17
Model DVU, DVFU
Standard Specifications, DVU
Design Discharge 2, 3, 4 inch
Horsepower 1 to 5HP, Single Phase
Features
1 to 2 HP, Three Phase 
Air-filled, heavy duty motor, rated for 20 starts/hour,
Capacity 16 to 430 GPM dissipates heat easily, operates cooler with higher
Total head 10 to 50 feet efficiencies; longer service life with lower
Max. Liquid temp. 104°F/40°C operating costs

Speed 1800 RPM Built-in motor protection with autocut, protects
motor against overheating, single phasing, and
Materials Casing Cast Iron
no load; saves money on costly motor replacement
Impeller Cast Iron 
Molded watertight cable prevents capillary
Shaft 403 Stainless Steel
action; reduces maintenance costs
Motor Frame Cast Iron 
60,000 hour bearings; ensures long, dependable
Fastener 304 Stainless Steel
operation and lowers maintenance costs
Construction Mechanical Seal 
Large solids handling capabilities prevents
Double Mechanical Seal clogging
Material – Upper Carbon/Ceramic 
Semi-open vortex type recessed impeller; multi-vane vortex design
Material – Lower Silicon Carbide/Silicon Carbide handles stringy material better and prevents clogging providing high
Impeller Type Semi-open Recessed Vortex reliability, durability and lower maintenance costs
Bearing Prelubricated Ball Bearing 
Stainless steel shaft – high tensile strength and corrosion resistance
Motor Air-filled, Insulation 
Double mechanical seals-silicon carbide lower seals, carbon/ceramic
Class F (DVU); Class H (DVFU)
upper - hard faced upper and lower seals operate in an oil bath;
Single Phase 208/230V
providing longer service life and lower maintenance costs
Three Phase 208/230V, 460V 
High wire to water efficiencies reduced power consumption; reduced
Service Factor 1.15 cost of operation
Motor Protection Built-in Auto cut - overload, no load, out of phase, 
Available for slide rail installations provides ease of maintenance for
single phasing protection
small sump type installations

Submersible Cable 33 ft. standard cable length, Optional 66 ft. Three phase, FM explosion proof, Class 1, Div. 1, Group C & D
available in DVFMU series 2 HP and above
Accessories Optional QDC System

DVU selection chart


m ft. 60 Hz (Synchronous Speed: 1800 RPM)
15 50

40 80DVC
50DVU62.2S 3HP U63.7S
5HP
10
30 80DVC 80DVB
U62.2S U63.7S
50DVU61.5 2HP 3HP 5HP
8
80D
Total Head

80DVU VB 100
20 61.5 2 U6
6 HP 2.2 DV
S U 63.
50DVU6.75 1HP 3H 7S
5 P 5H
15 P
4

10
3
8 USGPM
15 20 30 40 60 80 100 150 200 300 400 600
m 3/min.
.06 .08 0.1 .015 0.2 0.3 0.4 0.5 0.6 0.8 1.0 1.5 2.0
Capacity

18
submersible vortex sewage

Standard Specifications, DVFU


Design Discharge 2, 3, 4, 6 inch
Horsepower 2 to 30HP
Capacity 16 to 1200 GPM
Total head 13 to 121 feet
Max. Liquid temp. 104°F/40°C
Speed 1800 RPM
Materials Casing Cast Iron
Impeller Cast Iron
Shaft 403 Stainless Steel, 2 to 5HP
420 Stainless Steel, 71/2 to 30HP
Motor Frame Cast Iron
Fastener 304 Stainless Steel
Construction Mechanical Seal - Double Mechanical Seal
Material – Upper Carbon/Ceramic
Material – Lower Silicon Carbide/Silicon Carbide
Semi-Open Vortex Impeller Design Impeller Type Semi-opne Recessed Vortex
Bearing Prelubricated Ball Bearing

Semi-open vortex type recessed impeller; multi-vane Motor Insulation Class H;
vortex design handles stringy material better and Optional: FM Explosion Proof
Class 1, Division 1, Group C, D
prevents clogging providing high reliability, durability and Three Phase 208/230V, 460V
lower maintenance costs Service Factor 1.15
Motor Protection Built-in Thermal Detector - Klixon
Built-in Mechanical Seal Leakage
Submersible Cable 2 to 5HP - 33 ft. standard cable length
71/2 to 30HP - 50 ft. standard cable length
Optional _____ ft. (customer specified)
DVFU selection chart Accessories Optional QDC System

6 7
8
80DVCFU611 15HP

80DVBFU611 15HP 14
80DVFU67.5 10HP 15
13
5 12
50DVFU62.2 3HP 4 16
11
2
3 10 17
50DVFU61.5 2HP
9
1
80DVFU61.5 2HP

1 80DVBFU62.2 3HP 10 100DVFU65.5 7HP


2 80DVCFU62.2 3HP 11 100DVFU67.5 10HP
3 80DVBFU63.7 5HP 12 100DVBFU611 15HP
4 80DVCFU63.7 5HP 13 100DVCFU611
5 80DVFU65.5 7HP 14 100DVCFU615
6 80DVFU615 20HP 15 150DVCFU622
7 80DVFU618 25HP 16 150DVBFU622
8 80DVFU622 30HP 17 150DVBFU622 15HP
9 100DVFU63.7 5HP
19
Model DLFU, DLKFU, DDLFU
Standard Specifications, DLFU, DLKFU
Design Discharge 2, 3, 4, 6, 8, 10, 12 inch
Horsepower 2 to 60
Capacity 13 to 4000 GPM
Total head 7 to 243 feet
1 50DLFU61.5 2HP Max. Liquid temp. 104°F/40°C
2 80DLMFU61.5 2HP Speed 1800 RPM
3 80DLMFU62.2 3HP
4 80DLMFU63.7 5HP Materials Casing Cast Iron
'/0)8ó+3 Impeller Cast Iron (2 to 60HP)
6 80DLCMFU67.5 10HP Ductile Iron (150-300DLFU, 40 to 60HP)
7 80DLCMFU611 15HP Shaft 403 Stainless Steel, 2 to 5HP
8 100DLFU61.5 2HP 420 Stainless Steel, 71/2 to 60HP
9 80DLFU61.5 2HP Motor Frame Cast Iron
10 100DLMFU61.5 2HP Fastener 304 Stainless Steel
11 80DLFU62.2 3HP
12 100DLMFU62.2 3HP Construction Mechanical Seal Double Mechanical Seal
13 80DLFU63.7 5HP Material – Upper Carbon/Ceramic
14 100DLMFU63.7 5HP Optional: Tungsten Carbide/Tungsten/Carbide
'/)8ó+3 Material – Lower Silicon Carbide/Silicon Carbide, 2 to 60HP
'/0)8ó+3 Optional: Tungsten Carbide/Tungsten/Carbide
17 80DLFU67.5 10HP Tungsten Carbide/Tungsten Carbide, 150-300DLFU, 50 & 60 HP
18 100DLMFU67.5 10HP Impeller Type Semi-open, 2 to 30HP
19 80DLFU611 15HP
Enclosed, 40 to 60HP
20 100DLMFU611 15HP
K-Series, Model DLKFU – Features
21 80DLFU615 20HP
Bearing
Motor
Prelubricated Ball Bearing
Insulation Class H
22 100DLMFU615 20HP
Model DLKFU series pumps 23 are designed
80DLFU618 to tackle clogging challenges
25HP Optional: FM Explosion Proof Class 1, Division 1,
with enhanced passage 24 capabilities for 25HP
100DLMFU618 handling of fibrous waste. The Group C, D
design features address the 25 most common
80DLFU622 30HP reasons for clogging caused Three Phase 208/230V, 460V
by fibrous materials: 26 100DLMFU622 30HP Service Factor 1.15
 27 100DLFU630 40HP Motor Protection Built-in Thermal Detector - Klixon
Reduces material caught on the vane tips
 28 100DLFU637
Increases inlet pressure which keeps debris50HP moving instead of recirculating Mechanical Seal Leakage - Float Switch
 29 100DLFU645 60HP
E-liminator groove disrupts the accumulation of fibrous debris.
30 100DLFU62.2 3HP
Submersible Cable 2 to 5HP - 33 ft. standard cable length
31 100DLFU63.7 5HP 71/2 to 60HP - 50 ft. standard cable length
DLFU selection chart '/)8ó+3
33 100DLFU67.5 10HP Accessories
Optional _____ ft. (customer specified)
Optional QDC System
1 50DLFU61.5 2HP 34 100DLFU611 15HP
2 80DLMFU61.5 2HP 35 100DLFU615 20HP
3 80DLMFU62.2 3HP 36 100DLFU618 25HP m ft 60Hz (Synchronous Speed – 1800 RPM)
4 80DLMFU63.7 5HP 37 100DLFU622 30HP 300
80
'/0)8ó+3 38 150DLFU630 40HP
6 80DLCMFU67.5 10HP 39 150DLFU637 50HP 60 200 28 29
7 80DLCMFU611 15HP 40 150DLFU645 60HP 50 27
150
8 100DLFU61.5 2HP 41 150DLFU67.5 10HP 40 25 / 26 40
9 80DLFU61.5 2HP 42 150DLFU611 15HP 23 / 24 39
10 100DLMFU61.5 2HP 43 150DLFU615 20HP 30 100 7 21 / 22 38 48
6 37 47
11 80DLFU62.2 3HP 44 150DLFU618 25HP 80 36
19 / 20 61
5 46
TOTAL HEAD

12 100DLMFU62.2 3HP 45 150DLFU622 30HP 20 35


60 17 / 18
13 80DLFU63.7 5HP 46 200DLFU630 40HP 4 44 45 60
14 100DLMFU63.7 5HP 47 200DLFU637 50HP 15 50 15 / 16 43 53
34 52 59
'/)8ó+3 48 200DLFU645 60HP 40 3 66
13 / 14
'/0)8ó+3 49 200DLFU67.5 10HP 10 1 42 51 58
30 33 65
17 80DLFU67.5 10HP 50 200DLFU611 15HP 2 57
8 9 / 10 11 / 12 32 50 64
18 100DLMFU67.5 10HP 51 200DLFU615 20HP 31
19 80DLFU611 15HP 52 200DLFU618 25HP 6 20 41 63
30 54
20 100DLMFU611 15HP 53 200DLFU622 30HP 5 15 49 62
21 80DLFU615 20HP 54 250DLFU611 15HP 4 55 56
8
22 100DLMFU615 20HP 55 250DLBFU615 20HP 10
3
23 80DLFU618 25HP 56 250DLCFU615 20HP 10 15 20 30 40 50 60 80 100 150 200 300 400 500 600 800 1000 1500 2000 3000 4000 USGPM
24 100DLMFU618 25HP 57 250DLFU618 25HP
25 80DLFU622 30HP 58 250DLFU622 30HP 0.1 0.2 0.3 0.4 0.5 0.6 0.8 1.0 1.5 2.0 3.0 4.0 5.0 6.0 8.0 10 15 m3/min
26 100DLMFU622 30HP 59 250DLFU630 40HP CAPACITY
27 100DLFU630 40HP 60 250DLFU637 50HP
Please note: Overlap in coverage is designated by the two numbers; for example "9 / 10". Refer to the legend
28 100DLFU637 50HP 61 250DLFU645 60HP
left for the specific model numbers.
29 100DLFU645 60HP 62 300DLFU618 25HP
30 100DLFU62.2 3HP 63 300DLFU622 30HP 1 50DLFU61.5 2HP 19 80DLFU611 15HP 37 100DLFU622 30HP 55 250DLBFU615 20HP
31 100DLFU63.7 5HP 64 300DLFU630 40HP
'/)8ó+3 65 300DLFU637 50HP 2 80DLMFU61.5 2HP 20 100DLMFU611 15HP 38 150DLFU630 40HP 56 250DLCFU615 20HP
33 100DLFU67.5 10HP 66 300DLFU645 60HP 3 80DLMFU62.2 3HP 21 80DLFU615 20HP 39 150DLFU637 50HP 57 250DLFU618 25HP
34 100DLFU611 15HP
20 4 80DLMFU63.7 5HP 22 100DLMFU615 20HP 40 150DLFU645 60HP 58 250DLFU622 30HP
35 100DLFU615 20HP
submersible sewage, wet/dry pit model

Standard Specifications, DDLFU


Design Discharge 4"×3", 6"×4", 8"×6", 8"×8", 10"×10", 12"×12"
Horsepower 15 to 60HP
Capacity 80 to 4000 GPM
Total head 20 to 243 feet
Max.Liquid temp. 104°F/40°C
Speed 1800 RPM
Materials Casing Cast Iron
Impeller Cast Iron
Shaft 420 Stainless Steel
Motor Frame Cast Iron
Fastener 304 Stainless Steel
Construction Mechanical Seal
Double Mechanical Seal – Tandem Arrangement
Material – Upper Carbon/Ceramic
Optional: Tungsten Carbide/Tungsten/Carbide
Material – Lower Silicon Carbide/Silicon Carbide
Optional: Tungsten Carbide/Tungsten/Carbide
Tungsten Carbide/Tungsten Carbide
(200×150DDLFU and greater, 50 & 60 HP only)
Impeller Type Semi-open for 15 to 30HP
Enclosed for 40 to 60HP
Bearing Prelubricated Ball Bearing
Motor Insulation Class H
Optional: FM Explosion Proof Class 1, Division 1,
Group C, D
Three Phase 208/230V, 460V
Service Factor 1.15 1 150x100DDLFU615 20HP
Motor Protection Built-in Thermal Detector - Klixon
2 150x100DDLFU618 25HP
Mechanical Seal Leakage - Float Switch
3 150x100DDLFU622 30HP
Submersible Cable 50 ft. standard cable length
4 150x100DDLFU637
Optional _____ ft. (customer specified) 50HP
5 150x100DDLFU645 60HP
6 200x150DDLFU615 20HP

DDLFU selection chart 7 200x150DDLFU618 25HP


8 200x150DDLFU622 30HP
9 200x150DDLFU630 40HP
10 200x150DDLFU637 50HP
5
150x100DDLFU630 40HP
4
1 150x100DDLFU615 20HP 11 200x150DDLFU645 60HP
100x80DDLFU622 30HP 2 150x100DDLFU618 25HP 12 200x200DDLFU630 40HP
11
100x80DDLFU618 25HP 10
9 14 3 150x100DDLFU622 30HP 13 200x200DDLFU637 50HP
100x80DDLFU615 20HP 3 13
2 4 150x100DDLFU637 50HP 14 200x200DDLFU645 60HP
12
1
16 17 5 150x100DDLFU645 60HP 15 250x250DDLFU630 40HP
8
100x80DDLFU611 15HP 7 6 200x150DDLFU615 20HP 16 250x250DDLFU637 50HP
150x100DDLFU611 15HP 6 20
7 200x150DDLFU618 25HP 17 250x250DDLFU645 60HP
15 19
8 200x150DDLFU622 30HP 18 300x300DDLFU630 40HP
200 x150DDLFU
611 15HP 18 9 200x150DDLFU630 40HP 19 300x300DDLFU637 50HP
10 200x150DDLFU637 50HP 20 300x300DDLFU645 60HP
11 200x150DDLFU645 60HP
12 200x200DDLFU630 40HP
13 200x200DDLFU637 50HP
14 200x200DDLFU645 60HP
15 250x250DDLFU630 40HP
16 250x250DDLFU637 50HP
21
1 150x100DDLFU615 20HP 9 200x150DDLFU630 40HP 17 250x250DDLFU645 60HP
Model DLFU, DLKFU, DDLFU
Features

Watertight cable entry system prevents capillary
action and protects against moisture; reduces
maintenance costs

Heavy duty, high efficiency, air filled, Class H insulated,
rated for 356°F with a 1.15 service factor dissipates
heat easily; thermal protection in each phase of
windings protects; operates cooler with higher 

efficiencies; longer service life with lower operating 

costs

Self cooling jacket (Model DDLFU) eliminates the
need for external pumping devices or special heat 

transfer fluids; offers simplicity and high reliability by


effectively dissipating heat in dry pit applications only

Single and double row thrust bearings carries thrust
loads with L-10 life of 60,000 hours; ensures long, 

dependable operation and lowers maintenance costs



Mechanically actuated float switch provides early
warning of mechanical seal failure; avoids costly
motor repairs
 Double mechanical seals – silicon carbide lower
seals, carbon/ceramic upper – hard faced upper and
lower seals operate in an oil bath; providing longer

service life and lower maintenance costs

High efficiency impellers pass large solids with 

high outputs and reduces power consumption;


impellers are optimized for hydraulic coverage;
lowers operating costs 

Model DLKFU series pumps are designed to tackle


clogging challenges with enhanced passage capabilities 

for handling of fibrous waste.The design features


address the most common reasons for clogging 

caused by fibrous materials: Reduces material


caught on the vane tips, increases inlet pressure
which keeps debris moving instead of recirculating
and E-liminator groove disrupts the accumulation
of fibrous debris 


Replaceable wear components maintains working
clearances while reducing casing and volute costs

22
submersible sewage, wet/dry pit model

Cable Entry System


Primary seal – grommet (NBR)  Cable gland
(grey cast iron)


Secondary sealing – O-rings (NBR)


Epoxy resin –  
Solid joint butt connector

prevents capillary action (copper)

Note: Entry system is the same for both power and control cables.

QDC & Slide Rail System

23
Model DSC4, DSCA4, DSC
Standard Specifications
Design Discharge 6 to 24 inch
Horsepower 50 to 500
Capacity 530 to 35000 GPM
Total head 23 to 300 feet
Max. Liquid temp. 104°F/40°C
Materials Casing Cast Iron
Impeller Cast Iron
Casing Ring 420 Stainless Steel (enclosed Impeller models)
Shaft 420 Stainless Steel
Motor Frame Cast Iron
Cooling Jacket Steel
Fastener 304 Stainless Steel
Construction Impeller Type Semi-open
Enclosed
Optional: Impeller Ring (enclosed impeller models)
Shaft Seal Cartridge type duplex mechanical seals in
tandem arrangement
Material – Upper Carbon/Ceramic
Material – Lower Silicon Carbide/Silicon Carbide
Optional materials available, consult factory.
Bearing Grease Lubricated Ball Bearing
Motor Class H insulation
Air filled water tight with cooling jacket
15 starts/hour, 1.15 Service Factor
Optional: FM explosion proof, Class 1, Group C, D
Built-in winding temperature detector
Built-in float type leak detector
Optional: Temperature detector for thrust bearing
Mounting method Wet Pit: Quick discharge connector (QDC)
Dry Pit: with baseplate (DSCA4)
Accessories 50 ft (15.24 m) water tight rubber insulated
flexible cable
Optional cable lengths available, consult factory.

DSC4, DSCA4 selection chart Cable Entry Detail


(Ft) (m)
100
300
CC-46145
250 HO-46075
BC-46120
200 HO-46060
HO-46050 BC-46100
50
150
EO-66145 Power cable
(chloroprene
 rubber)
EO-66120
TOTAL HEAD

100
EO-66100 Cable housing
(gray cast iron)

AO-46075 Grommet
Cable clamp bolt
50 AO-46060 (304SS) 
(NBR)
AO-46050
40
GO-66075

Washer
10 FO-66060 (304SS)
30 
FO-66050


Gland bolt 
O rings
20 (304SS)  (NBR)

5 
Butt connector
(copper)
1 5 10 50 (m3/min) Epoxy resin
compound
0.5 1 1. 5 2 3 4 5 10 15 ×10 3 (prevents Cable gland
(USGPM) (gray cast iron)
CAPACITY capillary action)

24
large submersible sewage, wastewater wet/dry pit model

Double Mechanical Seal Detail Sealed Junction Area

Upper seal
 Oil Chamber


Lower seal Shaft sleeve


 

Pumpage

Impeller


Upper seal O rings – NBR
Upper seal faces – Carbon vs Ceramic
Leak Detection Area

Lower seal O rings – Viton

Lower seal faces – Silicon carbide vs Silicon carbide

Seal springs – 304SS Seal leak

Shaft sleeve – 304SS path

Optional seal face materials available 


Float Switch
Mechanical
seal oil

DSC3, DSCA3 selection chart Impeller


(Ft) (m)
100
300 90 60HZ
80
250
70 G1232-1780
200 60
G1102-1780
50 G1012-1770 F1302-1780
150
40 G0932-1770
G1233-1180 F1593-1180
G0852-1760
F1102-1780
100 30 E1262-1780
90 F0852 1760 G1232-1180 E1543-1180
G1102-1180 E1152-1770 E2424-685
80
E1052-1760
70 G0932-
20 E0852 1760 G1012-1180 D1262
TOTAL HEAD

60 1180 E0952 E2244-885


F1302-1180 -1770 D1553-1175
-1760
50 D2503-710
G0852-1180 C1203-1770
40 D1002-1760 C1103-1760
C1583-1175 C2113-885
E1262-1180 C2573-710
D0922 1760
10 C1463-1170
30 9 D0852 1760 C1943-885
E1152-1180
8 C2373-710 C2953-590
7 E1052-1180 C1793-885
C1583-880
20 6 C2113-710 C2573-590
C1463-880 C1943-710
5 C2373-590
15
4 C2113-590
FOR PRESELECTION ONLY

10 3
3 4 5 6 7 8 9 10 20 30 40 50 60 70 80 90 100 150 m 3/m
0.6 0.7 0.8 0.6 1.0 1.5 2 3 4 5 6 7 8 9 10 15 20 25 30 40,000 USGPM

CAPACITY

25
Accessories
EBARA Fluid Handling provides complete solutions for a wide range of applications across
various industries and offers additional accessories from control panels to drives, basin
packages, lifting chains, adapters, guide brackets, hoists and hatch covers for water and
waste water treatment submittal and bid packages.

Control Panels
Features Applications
· Basic, standard or custom · Industrial/Municipal
· All Nema rated enclosures; Components are UL Listed · Water
· IEC or Nema starters · Wastewater
· Separate alarm and control circuits
· Build to engineers’ or customer specifications
· Build to customer specifications

Single/Multiple pump flow controller


Features Applications
· Built-in SCADA software - program, startup, system trending, · Booster pump systems
status readout and diagnose · Commercial/Residential Irrigation
· Pump applications simulator - simulate drive parameters · Submersible deep wells
· Pump specific operator keypad · Fluid storage tanks
· Digital output monitoring · Metering pumps
· Simplex - simple setup · Sludge pumps
· Duplex/Triplex - Automatically starts and stops lead/lag · Settling ponds
pumps on demand
· Maintains constant system pressure
· Built to UL 508A Standards
· Serial communications options

Basin Packages Hatch Covers


Project: Model: Chk’d: Date:

EBARA Fluid Handling


26 www.pumpsebara.com
(t) 803 327 5005 • (f) 803 327 5097
The EBARA Group is constantly thinking
of what will be required in the future and
is seeking to accurately grasp the current
and future needs of its customers, while
continuing to pursue the development of
superior products in all its businesses
and by providing high quality support
and services.
Wastewater Experience
EBARA blends superior engineering expertise with state
of the art production techniques to produce pumps of
unsurpassed quality and long life. EBARA remains the
largest single brand pump company in the world and
strives to develop high quality, efficient products and key
system components for addressing improvements and
solutions in the fields of water supply, energy and
environmental issues. EBARA provides a full range
of services from engineering, project design and
construction to operation and maintenance for solid
waste treatment, water treatment, gasification, incineration
and other facilities.

Your Local EBARA representative:

EngineeredforPerformance

EBARA Fluid Handling


1651 Cedar Line Drive, Rock Hill, SC 29730
t (803) 327-5005 | f (803) 327-5097
www.pumpsebara.com
©2011 EBARA International Corporation, All rights reserved. 0914

You might also like