Project: Univotec

Element: upper Floor


REFERENCE DESIGN OF COMPOSITE SLAB UNITE

DATA
Deck Properties:
Overall depth of composite slab, D mm
Depth of composite deck, yb mm
b mm
a mm
lf mm
lw mm
Steel deck thickness, t mm
Steel grade,py N/mm2
Trough spacing mm
Self weight of deck kN/m2
Young's modulus of steel deck, Es kN/mm2
Deck span
Span m
Construction stage clear span m
After construction clear span m
Concrete
Cube strength,fcu N/mm2
Density(dry) kg/m3
Density(wet) kg/m3
Ec kN/mm2
Loads
Imposed load kN/m2
Partitions (imposed loads) kN/m2
Ceiling kN/m2
Self weight(slab) kN/m2
Construction load (temporary) kN/m2
CONSTRUCTION CONDITION
Self weight of slab, wd kN/m2
Self weight of deck kN/m2

sumedha
Total self weight , WT kN/m2
Design moment in construction condition,
kNmMu

Eq 20.1, Effective breath of flat compression plate, be mm


BS 5950: Neutral axis possision, X mm
Part 4 Second moment of area, I mm4/trough
mm4/m width
Depth of web in compression mm
d/t
Elastic section modulus, Ze mm3/m
Elastic resistance of momont saggin
BS 5950: (saggin moment), Mc kNm
Part 4, Bending moment after construction kNm
0.93Py Equevalant stress in compression plate, N/mm2
Second moment of area using equevalent stress,mm4/m width
Deflection of sofit of deck after
construction (simply supported),d mm

sumedha
COMPOSITE CONDITION
Area of deck mm2/trough
Ap mm2/m
Tensile resistance kN
Neutral axis depth in to concrete,Xc mm
Plastic moment resistance of
composite section,Mp kNm
Applied moment in composite condition,M
kNmu

Eq 20.2 Chech for incomplete shear connection


de mm
p
Lv mm
Md
kd
Vu kN
Applied ultimate shear force, V kN
Check shear stress on concrete, Vc N/mm2
Check deflection of composite slab
Properties of crack section
Neutral axis depth below upper surface of slab
modular ratio ,αe
Xe mm
Second moment of area of cracked section, Ic mm4/mm width
service load on composite slab,ws kN/m2
Deflection under service load, d mm

sumedha
Date: 19/09/2010

Designed: sumedha
VALUE REMARKS

125
50
55
25
125
56
1.2
280
300
0.12
205

3.00
2.90
2.90

30
1800
1900
26

5.0
1.0
0.5
2.0
1.5

1.86
0.12

sumedha
1.98
5.44

46.5
22.6
181600
605332
26.2
21.9
22563

5.9 FAILS
2.1
92
618870

14 OK

sumedha
434.4
1448
377
31.4

31.8
13.7 Mu<Mc, OK

100
0.0145
750
130
0.004
21.8
19.0 V<Vu, OK

0.19 OK

7.9
37.7
8504
6.5
3.4 SATISFACTORY

Mesh
reinforcment is
required for
crack control and
fire resistance

sumedha