1 Overview
1.1 Introduction
This document provides a high level description of the distributed baseband processing
Unit (BBU) ZXSDR B8200 (hereinafter B8200) that used in ZTE multi-mode wireless
solutions.
The baseband unit B8200, can be inserted into the integrated macro base station, or
connected to RRU in distributed base station. It is responsible for processing the
baseband signals. Based on ZTE SDR platform, it supports GSM, UMTS and FDD LTE
single-mode or multi-mode by software configuration. It enables operators to deploy one
unified radio access network rather than independent GSM, UMTS or LTE/LTE-A
network, which brings simplicity and convenience with low CAPEX and OPEX. Figure 1
shows the position of the ZXSDR B8200 in the typical multi-mode network.
1.2 Benefits
Large Capacity
B8200 adopts Plug-in design with 19-inch, 2U in height and 8.75 kg (with full
configuration) in weight. It can be conveniently mounted on the wall, ground, or in
the 19-inch rack, etc.
Flexible Networking
As the baseband processing unit, B8200 is widely used in ZTE series of base stations,
including indoor macro BS of ZXSDR BS8800, outdoor macro BS of ZXSDR
BS8900A/BS8900B, distributed BS of ZXSDR BS8700 and outdoor compact BS of
ZXSDR BS8906.
RRU Installation
RRU
B8200 Accommodation
B8200
2 Product Architecture
1 3 4
1. Power module (PM) 2. Site alarm board (SA) 3. Fabric switch board (FS) 4. Baseband processing
board (BP) 5. Fan array module (FAM) 6. Control & clock board (CC)
The baseband unit consists of control & clock board, fabric switch board, baseband
processing board, site alarm board, site alarm extension board (optional), universal
Ethernet switch (optional), tower mounted amplifier control module (optional), power
module, and fan module.
PM Power Module
Baseband Unit
Antenna
Baseband
Processing
FS
CPRI
(Optional RRU/RSU
for LTE)
SA/
E1
SE CC
Radio Unit
GE/FE
Control Signaling
Clock
Data
CC is the control & clock board, used for control and management of baseband unit,
providing Ethernet and system clock. There are mainly 3 types of CC boards in order to
meet different application requirements, illustrated in the following figures.
CC2:
CC16B:
CCE1:
Note: The boards are differentiated by the label attached on the panel, not included in the above
Note: 1. The above table describes the maximum hardware capability. The actual capability is up to
the licenses configured. 2. There is the GPS module embedded in CC16B/CCE1 but not in CC2.
Accomplishes LTE control plane protocol processing, including S1AP, X2AP, RRC,
etc.
Supports Ethernet switching function and implements data switching for service and
control flow within the system
Support aggregating traffic for switch which can be used for microwave, PDH,
Ethernet.
Reads various hardware management marks in the system, including the rack
number, backplane type number, slot number, board function type, board version,
and board function configuration mark
Monitors, controls and maintains the base station system with LMT interface
Provides a real-time clock for system operation and maintenance and calibrates the
real-time clock
Supports 2 CC boards for different modes: one for GU dual-mode and the other for
LTE mode
1. UBPG /UBPG3
Both UBPG and UBPG3 are GSM baseband processing boards, processing the physical
layer protocol and frame protocol specified by 3GPP, illustrated in the following figure.
Note: The boards are differentiated by the label attached at the left-bottom corner, not included in
the above figures. The product you receive is subject to the actual object.
UBPG supports 12 TRXs and UBPG3 supports 24 TRXs. Their main functions are listed
as follows:
Reads all the hardware management identifiers, including the backplane type
number, slot number, board function type, board version, board function
configuration identifier, and the CPU serial number
2. BPK_e1/BPK_e/BPK_d
BPK_e1, BPK_e and BPK_d are all UMTS baseband processing boards, processing the
physical layer protocol and frame protocol specified by 3GPP, illustrated in the following
figure.
Note: The boards are differentiated by the label attached at the left-bottom corner, not included in
the above figures. The product you receive is subject to the actual object.
They provide the same functions but with different CE, cell processing capability and
data throughput. The key indices are specified in the following table.
Note: The above table describes the maximum hardware capability. The actual capability is up to
Achieves uplink baseband signal processing, including uplink data RAKE receiving,
demodulator, and transmits data to lub interface for processing
Reads all the hardware management identifiers, including the backplane type
number, slot number, board function type, board version, board function
configuration identifier, and the CPU serial number
3. BPN0A/BPN0
BPN0A/BPN0 are all LTE baseband processing boards, processing the physical layer
protocol and frame protocol specified by 3GPP, illustrated in the following figure.
Note: The boards are differentiated by the label attached at the left-bottom corner, not included in
the above figures. The product you receive is subject to the actual object.
They provide the same functions but with different CPRI interfaces, cell processing
capability and data throughput. The key indices are specified in the following table.
Note: The above table describes the maximum hardware capability. The actual capability is up to
4. BPN2
Note: The boards are differentiated by the label attached at the left-bottom corner, not included in
the above figures. The product you receive is subject to the actual object.
They provide the same functions but with different processing capabilities. The key
indices are specified in the following table.
Board BPN2
GSM 72 TRXs
12 CSs(1024CEs)
UMTS
DL 518.4Mbps/UL 138Mbps
12 TRXs + 12 CSs(768CEs)
24 TRXs + 9 CSs(640CEs)
GU dual-mode
36 TRXs + 6 CSs(512CEs)
48 TRXs + 6 CSs(256CEs)
Note: The above table describes the maximum hardware capability. The actual capability is up to
FS is fabric switch board which provides the optical interface between BBU and RRU and
processes the IQ signal. There are 5 types of FS boards, illustrated in the following
figure.
FS3:
FS3A:
FS5:
FS5A:
CR0:
Note: The boards are differentiated by the label attached at the left-bottom corner, not included in
the above figures. The product you receive is subject to the actual object.
Max. CSs,
working with one 6 12 12 12 12
UMTS BP board
Max. CSs,
working with
30 48 60 60 60
UMTS BP
boards per BBU
Receives the signal from the rear board in the downlink and retrieves the data and
timing.
Supports I/Q mapping in the downlink and multiplexes I/Q signal to the optical
signals
Exchanges the CPU interface signaling through HDLC interface with RU module
There are two types of SA boards with different number of interfaces, as specified in the
following table.
SE is site alarm extension board, and shares the bottom-right slot with baseband
processing board. It is used to extend the interface number if SA cannot fulfill the
requirements. The SE panel is illustrated in the following figure.
There are two types of SE boards with different number of interfaces, as specified in the
following table.
UES is used for synchronized Ethernet and the panel is illustrated in the following figure.
UCI is the RGPS clock interface board. There are two types of UCI boards: UCI and
UCI-C. UCI/UCI-C panel is illustrated in Figure 2-12.
Note: The boards are differentiated by the label attached at the left-bottom corner, not included in
the above figures. The product you receive is subject to the actual object.
TAM is used for tower mounted amplifier control when TMA is needed. Panel of TAM is
shown as following figure.
Supports working status detection of tower amplifier and reports alarm signals to
CC board
Provides power on and off for tower amplifier with +28V, +12V or +13V power
supply
PM is the power module, including PM3 and PM5. PM5 has 50% more power supply
than PM3 for full configuration of new high power consumption boards, shown in the
following figure.
PM3:
PM5:
Note: The boards are differentiated by the label attached at the left-bottom corner, not included in
the above figures. The product you receive is subject to the actual object.
ON/OFF (PM3 only) Power switch, turning on/off 12V power to/from BBU
FAM is fan array module. Its panel is illustrated in the following figure.
The software architecture of the ZXSDR B8200 can be divided into three layers:
Hardware layer
OMC-B OSS
Linux
Hardware (BSP)
RNLC (radio network layer control) provides common and dedicated radio resource
management and control functions for control plane
The SDR platform software provides the functions of Operation Support Sub-system
(OSS), Operating And Maintenance (OAM), Data Base Sub-system (DBS), Bearer
Sub-system (BRS) and System Control Sub-system (SCS):
OSS is the support layer in this entire framework, which is a hardware independent
platform for running software and provides basic functions like scheduling, timer,
OAM provides the configuration, alarm and performance measurement function for
base station.
Board Support Package (BSP) is the software closely connected with the board
hardware and supports Real Time Operation Support Sub-system (RT OSS) to work on
the board.
2.4 Functionality
Power control
Synchronization
DTX
BBU support the FDD part of ETSI EN 301 908 V5.2.1 which are specifications for
electromagnetic compatibility and radio spectrum matters by ESTI.
3 Technical Specifications
Item Indices
60 CSs
36 cells
(1T1R/1T2R/2T2R/2T4R)
LTE(2C
36 Cells (4T4R) 2CCE1+6BPN2+2PM+1SA
CE1)
21600 RRC_connnected users
3.6Gbps UL/7.2Gbps DL
12 cells
LTE(1C 1CC16B+1BPN2+2PM+1SA
(1T1R/1T2R/2T2R/2T4R)
C16B) *2PM:1+1 backup
6 Cells (4T4R)
900Mbps DL/600Mbps UL
Note: 1. CC16B board supports GE/FE interface and thus limits the total data throughput to
1000Mbps in the physical layer (900Mbps in application layer for LTE single mode). 2. The above
table describes the maximum hardware capacity. The actual capacity is up to the licenses
configured.3. GUL multi-mode capacity can be calculated according the capacity of the configured
12 TRXs/1 UBPG 75
24 TRXs/1 UBPG3 80
6CSs/3 BPK_e/BPK_e1 85
6 cells/1 BPN0 85
1
10M/100M/1000M 10/100/1000BASE-
electrical RJ45 T IEEE 802.3
Auto-Negotiation. compatible
Abis/Iub/S1/X2 Ethernet Auto-MDI/MDIX
(CC2/CC16B) (either or) 1000BASE-LX
IEEE 802.3
1 1000M optical
SFP (LC) compatible,
Or 1 100M optical
100BASE-FX IEEE
802.3 compatible
2
10M/100M/1000M 10/100/1000BASE-
electrical RJ45 T IEEE 802.3
Auto-Negotiation. compatible
Auto-MDI/MDIX
Abis/Iub/S1/X2 10GBASE-SR,10G
Ethernet BASE-SW,10GBAS
(CCE1)
E-LR,10GBASE-L
2 10G optical
W IEEE 802.3
Or 2 1000M SFP (LC)
compatible,
optical
1000BASE-LX
IEEE 802.3
compatible
1
Cascading,
10M/100M/1000M 10/100/1000BASE-
Debugging or
Ethernet electrical RJ45 T IEEE 802.3
Local
Auto-Negotiation. compatible
Maintenance
Auto-MDI/MDIX
6 pairs
Baseband Electrical
/FS/BPN0A/BPN0 SFP (LC) CPRI
/Radio /Optical
/BPN2
Item Requirement
Item Requirement
The reliability of the ZXSDR B8200 system conforms to the national military GJB/Z299B
Electronic Equipment Reliability Estimation Manual and the IEC TR62390 standard.
The Reliability characteristics vary at different configurations. The reliability indices are
calculated based on typical configuration supporting GUL multi-mode, listed in table 3-8.
Item Value
4 Configurations Principles
B8200 is the baseband unit of macro base station, which is composed of the following
boards: CC, BP, FS, SA/SE, UES, TAM, PM, FAM, etc. Configuration principles of these
boards are described in the following table:
Refer to table 2-5 for the key indices. Maximally 5 boards can be
BPK_e1
configured.
Refer to table 2-5 for the key indices. Maximally 5 boards can be
BPK_e
configured.
Refer to table 2-5 for the key indices. Maximally 5 boards can be
BPK_d
BP configured.
Refer to table 2-6 for the key indices. Maximally 6 boards can be
BPN0A
configured.
Refer to table 2-6 for the key indices. Maximally 6 boards can be
BPN0
configured.
Refer to table 2-8 for the key indices. Maximally 6 boards can be
BPN2
configured in LTE single mode or 5 boards in GUL multi-mode.
Note: The above table describes the maximum hardware capacity. The actual capacity is up to the
licenses configured.
5.1 BC8910B/BC8911B
BC8910B is the largest cabinet out of three cabinets, including baseband unit shelf, fan
and ventilation system, AC/DC power system and additional 4U space reserved for
transmission or other equipments. Moreover, BC8910B contains 2 sets of batteries,
which maximally supports 2*150AH/135AH.
BC8911B has similar hardware structure with BC8910B, except that it contains 1 set of
battery and 11U space reserved for transmission or other equipments.
1. Fan and ventilation vessel 2.AC/DC power system 3. Power distribution unit 4. B8200
5. Reserved space (for transmission, etc) 6. Battery
5.2 BC8910A
BC8910A is the medium-sized one in the three cabinets. It can be used when there are
auxiliary devices should be contained but without battery. There are mainly five parts in
BC8910A: baseband unit, power supply system, power distribution module, heat
exchanging system and reserved space for transmission or other equipments. Together
with the fan system and ventilation vessel, the heat exchanger located in the cabinet
door makes the heat exchanging system. The fan system contains fan control element
(FCE) and 6 fans. BC8910A hardware architecture is shown in the following figure.
1. Fan and ventilation vessel 2.AC/DC power system 3. B8200 4.Cable chute 5.Lightning
Protection 6.Reserved space (for transmission, etc) 7.Heater 8.Heat exchange
In the case of DC power supply, AC/DC power system (5U) should be replaced by DC
power distribution with 2U in height.
1. Fan and ventilation vessel 2.DC power system 3.B8200 4.Cable chute 5.Lightning protection
6.Reserved space (for transmission, etc) 7.Heater 8.Heat exchange
ZXSDR BS8906 is the smallest one out of three cabinets. It is the outdoor compact base
station, with two kinds of cabinets: compact Cabinet, consisting of BBU, RSU and
supporting modules, and standalone cabinet, consisting of BBU and supporting modules.
If used outdoor for containing BBU without many ancillary devices, standalone cabinet
can be chosen to accommodate BBU inside. The physical structures are shown in the
following figure.
5
2
6
3
1. Fan control element 2.B8200 3. AC/DC protection module 4. Fan and ventilation vessel 5. Power
supply unit 6. Lightning protection/MW indoor unit/SDH
ZXSDR BS8906
Item BC8910B/BC8911B BC8910A
(Standalone)
Dimension (H*W*D)
With silencing cover:
(mm *mm*mm) 800*600*600 670*300*525
1600*700*780
(Without the base)
BBU Number 2 1 1
Note: If needed, the base is additionally configured for BC8910B/BC8911B, and the
cover and base are additionally configured for BC8910A.
6 Glossary
Abbreviations Full Characteristics
rd
3GPP 3 Generation Partnership Project
BP Baseband Processing
DL Downlink
FE Fast Ethernet
GE Gigabit Ethernet
PM Power Module
UE User Equipment
UL Uplink