Professional Documents
Culture Documents
Vibration Check For LO Purifier
Vibration Check For LO Purifier
Measuring
point 1 2 3 4 5 6 7
With
2.2 2.6 1.8 1.2 1.1 2.4
product
Without
product
2.4 2.2 2.0 1.5 1.3 3.5
During
10.5
ejection
Remarks:
-max 2.8 mm/s means acceptable running behavior.
-max. 4.5 mm/s means, the machine has to be de-sludged.
-max. 7 mm/s means, the machine has to be stopped and the cause for this high vibration level
must be investigated and eliminated.