Ring Terminal https://quickserve.cummins.com/qs3/pubsys2/xml/en/procedures/99/99-...

Connector Replacement
Terminals are used for various connections including grounds
and fuel shutoff valve supply.

Use wire crimp tool, Part Number 3822930, to cut and


remove the ring terminal connector as shown.

Use wire crimp tool, Part Number 3822930, to remove 6 mm


[1/4 in] of insulation from the harness wire.

Install the proper-size ring terminal on the bare wire. The ring
terminals that are included in the wiring repair kit, Part
Number 3164572, are as follows:

Ring Terminal Size Part No.


No. 10 3823760
1/2 inch 3823761

1 of 2 19/02/2020 19:08
Ring Terminal https://quickserve.cummins.com/qs3/pubsys2/xml/en/procedures/99/99-...

CAUTION

Only use wire crimping pliers, Part Number 3822930,


when repairing electrical terminals.

Crimp the repair wire on the bare wire.

Use a heat gun, Part Number 3822860, or open flame to


heat the shrink tubing. The tubing will shrink and make the
connection waterproof.

Last Modified: 21-Mar-2012

2 of 2 19/02/2020 19:08