Professional Documents
Culture Documents
Ankraj Ve Filiz Ekimine Uygun HIT-HY 150 Kimyasal Dübel Için Teknik Bilgi Formu PDF
Ankraj Ve Filiz Ekimine Uygun HIT-HY 150 Kimyasal Dübel Için Teknik Bilgi Formu PDF
PROFIS
Small edge Variable High
Fire Corrosion Anchor
Concrete distance embedment corrosion
resistance resistance design
and spacing depth resistance
software
Approvals / certificates
Description Authority / Laboratory No. / date of issue
Fire test report MFPA Braunschweig UB 3027 / 0274-6 / 1994-06-30
Assessment report (fire) warringtonfire WF 166402 / 2007-10-26
a) All data given in this section according ETA-05/0051 issue 2011-03-17.
632 10 / 2012
Hilti HIT-HY 150
with HIT-V / HAS
Embedment depth a) and base material thickness for the basic loading data.
Mean ultimate resistance, characteristic resistance, design resistance, recommended
loads.
Anchor size M8 M10 M12 M16 M20 M24 M27 M30
Typical embedment depth hef [mm] 80 90 110 125 170 210 240 270
Base material thickness h [mm] 110 120 140 165 220 270 300 340
a) The allowed range of embedment depth is shown in the setting details. The corresponding load values can be
calculated according to the simplified design method.
10 / 2012 633
Hilti HIT-HY 150
with HIT-V / HAS
Materials
Mechanical properties of HIT-V / HAS
Anchor size M8 M10 M12 M16 M20 M24 M27 M30
HIT-V/HAS 5.8 [N/mm²] 500 500 500 500 500 500 500 500
Nominal HIT-V/HAS 8.8 [N/mm²] 800 800 800 800 800 800 800 800
tensile
strength fuk HIT-V/HAS -R [N/mm²] 700 700 700 700 700 700 500 500
HIT-V/HAS -HCR [N/mm²] 800 800 800 800 800 700 700 700
HIT-V/HAS 5.8 [N/mm²] 400 400 400 400 400 400 400 400
Yield HIT-V/HAS 8.8 [N/mm²] 640 640 640 640 640 640 640 640
strength fyk HIT-V/HAS -R [N/mm²] 450 450 450 450 450 450 210 210
HIT-V/HAS -HCR [N/mm²] 600 600 600 600 600 400 400 400
Stressed HAS [mm²] 32,8 52,3 76,2 144 225 324 427 519
cross-
section As HIT-V [mm²] 36,6 58,0 84,3 157 245 353 459 561
Moment of HAS [mm³] 27,0 54,1 93,8 244 474 809 1274 1706
resistance
W HIT-V [mm³] 31,2 62,3 109 277 541 935 1387 1874
634 10 / 2012
Hilti HIT-HY 150
with HIT-V / HAS
Material quality
Part Material
Threaded rod Strength class 5.8, A5 > 8% ductile
HIT-V(F), steel galvanized ≥ 5 µm,
HAS 5.8: M8 – M24 (F) hot dipped galvanized ≥ 45 µm,
Threaded rod Strength class 8.8, A5 > 8% ductile
HIT-V(F), steel galvanized ≥ 5 µm,
HAS 8.8: M27 – M30 (F) hot dipped galvanized ≥ 45 µm,
Stainless steel grade A4, A5 > 8% ductile
Threaded rod
strength class 70 for ≤ M24 and class 50 for M27 to M30, 1.4401; 1.4404;
HIT-V-R, HAS-R
1.4578; 1.4571; 1.4439; 1.4362
High corrosion resistant steel, 1.4529; 1.4565
Threaded rod
strength ≤ M20: Rm = 800 N/mm², Rp 0.2 = 640 N/mm², A5 > 8% ductile
HIT-V-HCR, HAS-HCR
M24 to M30: Rm = 700 N/mm², Rp 0.2 = 400 N/mm², A5 > 8% ductile
Steel galvanized, hot dipped galvanized,
Washer
Stainless steel, 1.4401; 1.4404; 1.4578; 1.4571; 1.4439; 1.4362
ISO 7089
High corrosion resistant steel, 1.4529; 1.4565
Strength class 8,
steel galvanized ≥ 5 µm,
hot dipped galvanized ≥ 45 µm
Nut
Strength class 70, stainless steel grade A4,
EN ISO 4032
1.4401; 1.4404; 1.4578; 1.4571; 1.4439; 1.4362
Strength class 70, high corrosion resistant steel,
1.4529; 1.4565
Anchor dimensions
Anchor size M8 M10 M12 M16 M20 M24 M27 M30
M12x110
M16x125
M20x170
M24x210
M27x240
M30x270
M10x90
Anchor rod
M8x80
Embedment depth hef [mm] 80 90 110 125 170 210 240 270
Anchor rod
Anchor rods HIT-V (-R / -HCR) are available in variable length
HIT-V, HIT-V-R, HIT-V-HCR
Setting
installation equipment
Anchor size M8 M10 M12 M16 M20 M24 M27 M30
Rotary hammer TE 2 – TE 16 TE 40 – TE 70
Other tools compressed air gun or blow out pump, set of cleaning brushes, dispenser
10 / 2012 635
Hilti HIT-HY 150
with HIT-V / HAS
Setting instruction
a)
b)
a) Note: Manual cleaning for element sizes d ≤ 16mm and embedment depth hef ≤ 10 d only!
b) Note: Extension and piston plug needed for overhead installation and/or embedment depth > 250mm!
For detailed information on installation see instruction for use given with the package of the product.
636 10 / 2012
Hilti HIT-HY 150
with HIT-V / HAS
Setting details
Marking of the
embedment depth
d0
df
Fixture
Bore hole depth h0 = anchorage depth hef Thickness tfix
10 / 2012 637
Hilti HIT-HY 150
with HIT-V / HAS
Setting details
Anchor size M8 M10 M12 M16 M20 M24 M27 M30
Nominal diameter of
d0 [mm] 10 12 14 18 24 28 30 35
drill bit
Effective embedment and hef,min [mm] 60 60 70 80 90 100 110 120
drill hole depth range
a)
for HIT-V hef,max [mm] 160 200 240 320 400 480 540 600
Effective anchorage and
drill hole depth hef [mm] 80 90 110 125 170 210 240 270
for HAS
Minimum base hef + 30 mm
hmin [mm] hef + 2 d0
material thickness ≥ 100 mm
Diameter of clearance
df [mm] 9 12 14 18 22 26 30 33
hole in the fixture
b)
Torque moment Tmax [Nm] 10 20 40 80 150 200 270 300
Minimum spacing smin [mm] 40 50 60 80 100 120 135 150
Minimum edge
cmin [mm] 40 50 60 80 100 120 135 150
distance
Critical spacing
scr,sp [mm] 2 ccr,sp
for splitting failure
For spacing (or edge distance) smaller than critical spacing (or critical edge distance) the design loads have to be
reduced.
a) Embedment depth range: hef,min ≤ hef ≤ hef,max
b) Maximum recommended torque moment to avoid splitting failure during installation with minimum spacing
and/or edge distance.
c) h: base material thickness (h ≥ hmin), hef: embedment depth
d) The critical edge distance for concrete cone failure depends on the embedment depth hef and the design bond
resistance. The simplified formula given in this table is on the save side.
638 10 / 2012
Hilti HIT-HY 150
with HIT-V / HAS
For more complex fastening applications please use the anchor design software PROFIS Anchor.
Tension loading
10 / 2012 639
Hilti HIT-HY 150
with HIT-V / HAS
Design concrete cone resistance NRd,c = N0Rd,c ⋅ fB ⋅ f1,N ⋅ f2,N ⋅ f3,N ⋅ fh,N ⋅ fre,N
Design splitting resistance NRd,sp = N0Rd,c ⋅ fB ⋅ f1,sp ⋅ f2,sp ⋅ f3,sp ⋅ f h,N ⋅ fre,N
Anchor size M8 M10 M12 M16 M20 M24 M27 M30
0
N Rd,c [kN] 24,1 24,0 32,4 33,6 53,3 73,2 89,4 106,7
Influencing factors
640 10 / 2012
Hilti HIT-HY 150
with HIT-V / HAS
Influence of reinforcement
hef [mm] 40 50 60 70 80 90 ≥ 100
fre,N = 0,5 + hef/200mm ≤ 1
a) a) a) a) a) a)
0,7 0,75 0,8 0,85 0,9 0,95 1
a) This factor applies only for dense reinforcement. If in the area of anchorage there is reinforcement with a
spacing ≥ 150 mm (any diameter) or with a diameter ≤ 10 mm and a spacing ≥ 100 mm, then a factor fre,N = 1
may be applied.
Shear loading
Design concrete pryout resistance VRd,cp = lower valuea) of k ⋅ NRd,p and k ⋅ NRd,c
k = 2 for hef ≥ 60 mm
a) NRd,p: Design combined pull-out and concrete cone resistance
NRd,c: Design concrete cone resistance
10 / 2012 641
Hilti HIT-HY 150
with HIT-V / HAS
Influencing factors
Influence of angle between load applied and the direction perpendicular to the free edge
Angle ß 0° 10° 20° 30° 40° 50° 60° 70° 80° ≥ 90°
1
fβ =
(cosα V )2 + sin α V
2
1 1,01 1,05 1,13 1,24 1,40 1,64 1,97 2,32 2,50
2,5
Influence of anchor spacing and edge distance a) for concrete edge resistance: f4
f4 = (c/hef)1,5 ⋅ (1 + s / [3 ⋅ c]) ⋅ 0,5
Single Group of two anchors s/hef
c/hef
anchor 0,75 1,50 2,25 3,00 3,75 4,50 5,25 6,00 6,75 7,50 8,25 9,00 9,75 10,50 11,25
0,50 0,35 0,27 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35
0,75 0,65 0,43 0,54 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65
1,00 1,00 0,63 0,75 0,88 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00
1,25 1,40 0,84 0,98 1,12 1,26 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40
1,50 1,84 1,07 1,22 1,38 1,53 1,68 1,84 1,84 1,84 1,84 1,84 1,84 1,84 1,84 1,84 1,84
1,75 2,32 1,32 1,49 1,65 1,82 1,98 2,15 2,32 2,32 2,32 2,32 2,32 2,32 2,32 2,32 2,32
2,00 2,83 1,59 1,77 1,94 2,12 2,30 2,47 2,65 2,83 2,83 2,83 2,83 2,83 2,83 2,83 2,83
2,25 3,38 1,88 2,06 2,25 2,44 2,63 2,81 3,00 3,19 3,38 3,38 3,38 3,38 3,38 3,38 3,38
2,50 3,95 2,17 2,37 2,57 2,77 2,96 3,16 3,36 3,56 3,76 3,95 3,95 3,95 3,95 3,95 3,95
2,75 4,56 2,49 2,69 2,90 3,11 3,32 3,52 3,73 3,94 4,15 4,35 4,56 4,56 4,56 4,56 4,56
3,00 5,20 2,81 3,03 3,25 3,46 3,68 3,90 4,11 4,33 4,55 4,76 4,98 5,20 5,20 5,20 5,20
3,25 5,86 3,15 3,38 3,61 3,83 4,06 4,28 4,51 4,73 4,96 5,18 5,41 5,63 5,86 5,86 5,86
3,50 6,55 3,51 3,74 3,98 4,21 4,44 4,68 4,91 5,14 5,38 5,61 5,85 6,08 6,31 6,55 6,55
3,75 7,26 3,87 4,12 4,36 4,60 4,84 5,08 5,33 5,57 5,81 6,05 6,29 6,54 6,78 7,02 7,26
4,00 8,00 4,25 4,50 4,75 5,00 5,25 5,50 5,75 6,00 6,25 6,50 6,75 7,00 7,25 7,50 7,75
4,25 8,76 4,64 4,90 5,15 5,41 5,67 5,93 6,18 6,44 6,70 6,96 7,22 7,47 7,73 7,99 8,25
4,50 9,55 5,04 5,30 5,57 5,83 6,10 6,36 6,63 6,89 7,16 7,42 7,69 7,95 8,22 8,49 8,75
4,75 10,35 5,45 5,72 5,99 6,27 6,54 6,81 7,08 7,36 7,63 7,90 8,17 8,45 8,72 8,99 9,26
5,00 11,18 5,87 6,15 6,43 6,71 6,99 7,27 7,55 7,83 8,11 8,39 8,66 8,94 9,22 9,50 9,78
5,25 12,03 6,30 6,59 6,87 7,16 7,45 7,73 8,02 8,31 8,59 8,88 9,17 9,45 9,74 10,02 10,31
5,50 12,90 6,74 7,04 7,33 7,62 7,92 8,21 8,50 8,79 9,09 9,38 9,67 9,97 10,26 10,55 10,85
a) The anchor spacing and the edge distance shall not be smaller than the minimum anchor spacing smin and the
minimum edge distance cmin.
642 10 / 2012
Hilti HIT-HY 150
with HIT-V / HAS
a)
Influence of edge distance
c/d 4 6 8 10 15 20 30 40
0,19
fc = (d / c) 0,77 0,71 0,67 0,65 0,60 0,57 0,52 0,50
a) The edge distance shall not be smaller than the minimum edge distance cmin.
Recommended loads can be calculated by dividing the design resistance by an overall partial safety factor for
action γ = 1,4. The partial safety factors for action depend on the type of loading and shall be taken from national
regulations.
10 / 2012 643
Hilti HIT-HY 150
with HIT-V / HAS
644 10 / 2012
Hilti HIT-HY 150
with HIT-V / HAS
10 / 2012 645
Hilti HIT-HY 150
with HIT-V / HAS
a)
Design resistance: concrete C 20/25 – fck,cube = 25 N/mm² - embedment depth = 12 d
Anchor size M8 M10 M12 M16 M20 M24 M27 M30
Embedment depth hef = 12 d a) [mm] 96 120 144 192 240 288 324 360
Base material thickness h = hmin [mm] 126 150 174 228 288 344 384 430
Tensile NRd: single anchor, no edge effects
HIT-V 5.8 [kN] 12,0 19,3 28,0 41,4 61,0 82,7 98,2 113,1
HIT-V 8.8 [kN] 17,7 23,0 33,2 41,4 61,0 82,7 98,2 113,1
HIT-V-R [kN] 13,9 21,9 31,6 41,4 61,0 82,7 80,4 98,3
HIT-V-HCR [kN] 17,7 23,0 33,2 41,4 61,0 82,7 98,2 113,1
Shear VRd: single anchor, no edge effects, without lever arm
HIT-V 5.8 [kN] 7,2 12,0 16,8 31,2 48,8 70,4 92,0 112,0
HIT-V 8.8 [kN] 12,0 18,4 27,2 50,4 78,4 112,8 147,2 179,2
HIT-V-R [kN] 8,3 12,8 19,2 35,3 55,1 79,5 48,3 58,8
HIT-V-HCR [kN] 12,0 18,4 27,2 50,4 78,4 70,9 92,0 112,0
a) d = element diameter
a)
Design resistance: concrete C 20/25 – fck,cube = 25 N/mm² - embedment depth = 12 d
Anchor size M8 M10 M12 M16 M20 M24 M27 M30
Embedment depth hef = 12 d a) [mm] 96 120 144 192 240 288 324 360
Base material thickness h = hmin [mm] 126 150 174 228 288 344 384 430
Edge distance c = cmin [mm] 40 50 60 80 100 120 135 150
Tensile NRd: single anchor, min. edge distance (c = cmin)
HIT-V 5.8
HIT-V 8.8
[kN] 10,3 13,4 19,3 25,2 37,7 51,9 62,6 73,4
HIT-V-R
HIT-V-HCR
Shear VRd: single anchor, min. edge distance (c = cmin) , without lever arm
HIT-V 5.8
HIT-V 8.8
[kN] 3,9 5,7 7,8 12,9 18,9 25,9 31,8 38,1
HIT-V-R
HIT-V-HCR
a) d = element diameter
a)
Design resistance: concrete C 20/25 – fck,cube = 25 N/mm² - embedment depth = 12 d
(load values are valid for single anchor)
Anchor size M8 M10 M12 M16 M20 M24 M27 M30
Embedment depth hef = 12 d a) [mm] 96 120 144 192 240 288 324 360
Base material thickness h = hmin [mm] 126 150 174 228 288 344 384 430
Spacing s=smin [mm] 40 50 60 80 100 120 135 150
Tensile NRd: double anchor, no edge effects, min. spacing (s = smin)
HIT-V 5.8 [kN] 12,0 15,5 22,0 28,0 41,2 55,8 66,6 77,3
HIT-V 8.8
HIT-V-R [kN] 12,1 15,5 22,0 28,0 41,2 55,8 66,6 77,3
HIT-V-HCR
Shear VRd: double anchor, no edge effects, min. spacing (s = smin) , without lever arm
HIT-V 5.8 [kN] 7,2 12,0 16,8 31,2 48,8 70,4 92,0 112,0
HIT-V 8.8 [kN] 12,0 18,4 27,2 50,4 78,4 112,8 147,2 179,2
HIT-V-R [kN] 8,3 12,8 19,2 35,3 55,1 79,5 48,3 58,8
HIT-V-HCR [kN] 12,0 18,4 27,2 50,4 78,4 70,9 92,0 112,0
a) d = element diameter
646 10 / 2012
Hilti HIT-HY 150
with HIT-V / HAS
10 / 2012 647
Hilti HIT-HY 150
with HIS-(R)N
PROFIS
Small edge
Corrosion Anchor
Concrete distance
resistance design
and spacing
software
Embedment depth and base material thickness for the basic loading data.
Mean ultimate resistance, characteristic resistance, design resistance, recommended
loads.
Anchor size M8x90 M10x110 M12x125 M16x170 M20x205
Embedment depth hef [mm] 90 110 125 170 205
Base material thickness h [mm] 120 150 170 230 270
648 10 / 2012
Hilti HIT-HY 150
with HIS-(R)N
10 / 2012 649
Hilti HIT-HY 150
with HIS-(R)N
Materials
Mechanical properties of HIS-(R)N
Anchor size M8x90 M10x110 M12x125 M16x170 M20x205
HIS-N [N/mm²] 490 490 460 460 460
Nominal Screw 8.8 [N/mm²] 800 800 800 800 800
tensile
strength fuk HIS-RN [N/mm²] 700 700 700 700 700
Screw A4-70 [N/mm²] 700 700 700 700 700
HIS-N [N/mm²] 410 410 375 375 375
Yield Screw 8.8 [N/mm²] 640 640 640 640 640
strength fyk HIS-RN [N/mm²] 350 350 350 350 350
Screw A4-70 [N/mm²] 450 450 450 450 450
Stressed HIS-(R)N [mm²] 51,5 108,0 169,1 256,1 237,6
cross-
section As Screw [mm²] 36,6 58 84,3 157 245
Moment of HIS-(R)N [mm³] 145 430 840 1595 1543
resistance W Screw [mm³] 31,2 62,3 109 277 541
Material quality
Part Material
a)
Internal threaded sleeve C-steel 1.0718,
HIS-N Steel galvanized ≥ 5µm
a)
Internal threaded sleeve
Stainless steel 1.4401 and 1.4571
HIS-RN
a) related fastening screw: strength class 8.8, A5 > 8% Ductile
steel galvanized ≥ 5µm
b) related fastening screw: strength class 70, A5 > 8% Ductile
stainless steel 1.4401; 1.4404; 1.4578; 1.4571; 1.4439; 1.4362
Anchor dimensions
Anchor size
Internal threaded sleeve M8x90 M10x110 M12x125 M16x170 M20x205
HIS-N / HIS-RN
Embedment depth hef [mm] 80 90 110 125 170
Setting
installation equipment
Anchor size M8x90 M10x110 M12x125 M16x170 M20x205
Rotary hammer TE 2 – TE 16 TE 40 – TE 70
Other tools compressed air gun or blow out pump, set of cleaning brushes, dispenser
650 10 / 2012
Hilti HIT-HY 150
with HIS-(R)N
Setting instruction
a)
b)
For detailed information on installation see instruction for use given with the package of the product.
10 / 2012 651
Hilti HIT-HY 150
with HIS-(R)N
Setting details
hS
df
d
d0
652 10 / 2012
Hilti HIT-HY 150
with HIS-(R)N
For spacing (or edge distance) smaller than critical spacing (or critical edge distance) the design loads have to be
reduced.
a) Maximum recommended torque moment to avoid splitting failure during installation with minimum spacing
and/or edge distance.
b) h: base material thickness (h ≥ hmin), hef: embedment depth
c) The critical edge distance for concrete cone failure depends on the embedment depth hef and the design bond
resistance. The simplified formula given in this table is on the save side.
10 / 2012 653
Hilti HIT-HY 150
with HIS-(R)N
For more complex fastening applications please use the anchor design software PROFIS Anchor.
Tension loading
Design concrete cone resistance NRd,c = N0Rd,c ⋅ fB ⋅ f1,N ⋅ f2,N ⋅ f3,N ⋅ fh,N ⋅ fre,N
Design splitting resistance NRd,sp = N0Rd,c ⋅ fB ⋅ f1,sp ⋅ f2,sp ⋅ f3,sp ⋅ f h,N ⋅ fre,N
Anchor size M8 M10 M12 M16 M20
0
N Rd,c [kN] 28,7 38,8 47,1 62,2 82,3
654 10 / 2012
Hilti HIT-HY 150
with HIS-(R)N
Influencing factors
Influence of reinforcement
hef [mm] 40 50 60 70 80 90 ≥ 100
fre,N = 0,5 + hef/200mm ≤ 1
a) a) a) a) a) a)
0,7 0,75 0,8 0,85 0,9 0,95 1
a) This factor applies only for dense reinforcement. If in the area of anchorage there is reinforcement with a
spacing ≥ 150 mm (any diameter) or with a diameter ≤ 10 mm and a spacing ≥ 100 mm, then a factor fre,N = 1
may be applied.
10 / 2012 655
Hilti HIT-HY 150
with HIS-(R)N
Shear loading
Design concrete pryout resistance VRd,cp = lower valuea) of k ⋅ NRd,p and k ⋅ NRd,c
k = 2 for hef ≥ 60 mm
a) NRd,p: Design combined pull-out and concrete cone resistance
NRd,c: Design concrete cone resistance
Influencing factors
Influence of angle between load applied and the direction perpendicular to the free edge
Angle ß 0° 10° 20° 30° 40° 50° 60° 70° 80° ≥ 90°
1
fβ =
(cosα V )2 + sin α V
2
1 1,01 1,05 1,13 1,24 1,40 1,64 1,97 2,32 2,50
2,5
656 10 / 2012
Hilti HIT-HY 150
with HIS-(R)N
Influence of anchor spacing and edge distance a) for concrete edge resistance: f4
f4 = (c/hef)1,5 ⋅ (1 + s / [3 ⋅ c]) ⋅ 0,5
Single Group of two anchors s/hef
c/hef
anchor 0,75 1,50 2,25 3,00 3,75 4,50 5,25 6,00 6,75 7,50 8,25 9,00 9,75 10,50 11,25
0,50 0,35 0,27 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35
0,75 0,65 0,43 0,54 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65
1,00 1,00 0,63 0,75 0,88 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00
1,25 1,40 0,84 0,98 1,12 1,26 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40
1,50 1,84 1,07 1,22 1,38 1,53 1,68 1,84 1,84 1,84 1,84 1,84 1,84 1,84 1,84 1,84 1,84
1,75 2,32 1,32 1,49 1,65 1,82 1,98 2,15 2,32 2,32 2,32 2,32 2,32 2,32 2,32 2,32 2,32
2,00 2,83 1,59 1,77 1,94 2,12 2,30 2,47 2,65 2,83 2,83 2,83 2,83 2,83 2,83 2,83 2,83
2,25 3,38 1,88 2,06 2,25 2,44 2,63 2,81 3,00 3,19 3,38 3,38 3,38 3,38 3,38 3,38 3,38
2,50 3,95 2,17 2,37 2,57 2,77 2,96 3,16 3,36 3,56 3,76 3,95 3,95 3,95 3,95 3,95 3,95
2,75 4,56 2,49 2,69 2,90 3,11 3,32 3,52 3,73 3,94 4,15 4,35 4,56 4,56 4,56 4,56 4,56
3,00 5,20 2,81 3,03 3,25 3,46 3,68 3,90 4,11 4,33 4,55 4,76 4,98 5,20 5,20 5,20 5,20
3,25 5,86 3,15 3,38 3,61 3,83 4,06 4,28 4,51 4,73 4,96 5,18 5,41 5,63 5,86 5,86 5,86
3,50 6,55 3,51 3,74 3,98 4,21 4,44 4,68 4,91 5,14 5,38 5,61 5,85 6,08 6,31 6,55 6,55
3,75 7,26 3,87 4,12 4,36 4,60 4,84 5,08 5,33 5,57 5,81 6,05 6,29 6,54 6,78 7,02 7,26
4,00 8,00 4,25 4,50 4,75 5,00 5,25 5,50 5,75 6,00 6,25 6,50 6,75 7,00 7,25 7,50 7,75
4,25 8,76 4,64 4,90 5,15 5,41 5,67 5,93 6,18 6,44 6,70 6,96 7,22 7,47 7,73 7,99 8,25
4,50 9,55 5,04 5,30 5,57 5,83 6,10 6,36 6,63 6,89 7,16 7,42 7,69 7,95 8,22 8,49 8,75
4,75 10,35 5,45 5,72 5,99 6,27 6,54 6,81 7,08 7,36 7,63 7,90 8,17 8,45 8,72 8,99 9,26
5,00 11,18 5,87 6,15 6,43 6,71 6,99 7,27 7,55 7,83 8,11 8,39 8,66 8,94 9,22 9,50 9,78
5,25 12,03 6,30 6,59 6,87 7,16 7,45 7,73 8,02 8,31 8,59 8,88 9,17 9,45 9,74 10,02 10,31
5,50 12,90 6,74 7,04 7,33 7,62 7,92 8,21 8,50 8,79 9,09 9,38 9,67 9,97 10,26 10,55 10,85
a) The anchor spacing and the edge distance shall not be smaller than the minimum anchor spacing smin and the
minimum edge distance cmin.
10 / 2012 657
Hilti HIT-HY 150
with HIS-(R)N
Recommended loads can be calculated by dividing the design resistance by an overall partial safety factor for
action γ = 1,4. The partial safety factors for action depend on the type of loading and shall be taken from national
regulations.
658 10 / 2012
Hilti HIT-HY 150
with HIS-(R)N
10 / 2012 659
Hilti HIT-HY 150
with rebar
PROFIS
Small edge Variable
Anchor
Concrete distance embedment
design
and spacing depth
software
660 10 / 2012
Hilti HIT-HY 150
with rebar
Embedment depth a) and base material thickness for the basic loading data. Mean
ultimate resistance, characteristic resistance, design resistance, recommended loads.
Anchor size Ø8 Ø10 Ø12 Ø14 Ø16 Ø20 Ø25
b)
Embedment depth hef = hef,typ [mm] 80 90 110 125 170 210 240
Base material thickness h [mm] 110 120 140 165 220 270 300
a) The allowed range of embedment depth is shown in the setting details. The corresponding load values can be
calculated according to the simplified design method.
b) hef,typ: Typical embedment depth
10 / 2012 661
Hilti HIT-HY 150
with rebar
Materials
Mechanical properties of rebar BSt 500S
Anchor size Ø8 Ø10 Ø12 Ø14 Ø16 Ø20 Ø25
Nominal
tensile BSt 500 S [N/mm²] 550
strength fuk
Yield
BSt 500 S [N/mm²] 500
strength fyk
Stressed
cross- BSt 500 S [mm²] 50,3 78,5 113,1 153,9 201,1 314,2 490,9
section As
Moment of
resistance BSt 500 S [mm³] 50,3 98,2 169,6 269,4 402,1 785,4 1534
W
Material quality
Part Material
rebar Mechanical properties according to DIN 488-1:1984
BSt 500 S Geometry according to DIN 488-21:1986
Anchor dimensions
Anchor size Ø8 Ø10 Ø12 Ø14 Ø16 Ø20 Ø25
rebar
rebar are available in variable length
BSt 500 S
Setting
installation equipment
Anchor size Ø8 Ø10 Ø12 Ø14 Ø16 Ø20 Ø25
Rotary hammer TE 2 – TE 16 TE 40 – TE 70
Other tools compressed air gun or blow out pump, set of cleaning brushes, dispenser
662 10 / 2012
Hilti HIT-HY 150
with rebar
Setting instruction
a)
b)
a) Note: Manual cleaning for element sizes d ≤ 14mm and embedment depth hef ≤ 10 d only!
b) Note: Extension and piston plug needed for overhead installation and/or embedment depth > 250mm!
For detailed information on installation see instruction for use given with the package of the product.
10 / 2012 663
Hilti HIT-HY 150
with rebar
Setting details
d0
664 10 / 2012
Hilti HIT-HY 150
with rebar
for rebar BSt 500 S hef,max [mm] 160 200 240 280 320 400 500
Minimum base hef + 30 mm
hmin [mm] hef + 2 d0
material thickness ≥ 100 mm
Minimum spacing smin [mm] 40 50 60 70 80 100 150
Minimum edge
cmin [mm] 40 50 60 80 100 120 150
distance
Critical spacing
scr,sp [mm] 2 ccr,sp
for splitting failure
For spacing (or edge distance) smaller than critical spacing (or critical edge distance) the design loads have to be
reduced.
a) Embedment depth range: hef,min ≤ hef ≤ hef,max
b) h: base material thickness (h ≥ hmin), hef: embedment depth
c) The critical edge distance for concrete cone failure depends on the embedment depth hef and the design bond
resistance. The simplified formula given in this table is on the save side.
10 / 2012 665
Hilti HIT-HY 150
with rebar
For more complex fastening applications please use the anchor design software PROFIS Anchor.
Tension loading
Design concrete cone resistance NRd,c = N0Rd,c ⋅ fB ⋅ f1,N ⋅ f2,N ⋅ f3,N ⋅ fh,N ⋅ fre,N
Design splitting resistance NRd,sp = N0Rd,c ⋅ fB ⋅ f1,sp ⋅ f2,sp ⋅ f3,sp ⋅ f h,N ⋅ fre,N
Anchor size Ø8 Ø10 Ø12 Ø14 Ø16 Ø20 Ø25
0
N Rd,c [kN] 24,1 24,0 32,4 33,6 42,0 53,3 73,2
666 10 / 2012
Hilti HIT-HY 150
with rebar
Influencing factors
Influence of reinforcement
hef [mm] 40 50 60 70 80 90 ≥ 100
fre,N = 0,5 + hef/200mm ≤ 1
a) a) a) a) a) a)
0,7 0,75 0,8 0,85 0,9 0,95 1
a) This factor applies only for dense reinforcement. If in the area of anchorage there is reinforcement with a
spacing ≥ 150 mm (any diameter) or with a diameter ≤ 10 mm and a spacing ≥ 100 mm, then a factor fre,N = 1
may be applied.
10 / 2012 667
Hilti HIT-HY 150
with rebar
Shear loading
Design concrete pryout resistance VRd,cp = lower valuea) of k ⋅ NRd,p and k ⋅ NRd,c
k = 2 for hef ≥ 60 mm
a) NRd,p: Design combined pull-out and concrete cone resistance
NRd,c: Design concrete cone resistance
Influencing factors
Influence of angle between load applied and the direction perpendicular to the free edge
Angle ß 0° 10° 20° 30° 40° 50° 60° 70° 80° ≥ 90°
1
fβ =
(cosα V )2 + sin α V
2
1 1,01 1,05 1,13 1,24 1,40 1,64 1,97 2,32 2,50
2,5
668 10 / 2012
Hilti HIT-HY 150
with rebar
Influence of anchor spacing and edge distance a) for concrete edge resistance: f4
f4 = (c/hef)1,5 ⋅ (1 + s / [3 ⋅ c]) ⋅ 0,5
Single Group of two anchors s/hef
c/hef
anchor 0,75 1,50 2,25 3,00 3,75 4,50 5,25 6,00 6,75 7,50 8,25 9,00 9,75 10,50 11,25
0,50 0,35 0,27 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35
0,75 0,65 0,43 0,54 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65
1,00 1,00 0,63 0,75 0,88 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00
1,25 1,40 0,84 0,98 1,12 1,26 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40
1,50 1,84 1,07 1,22 1,38 1,53 1,68 1,84 1,84 1,84 1,84 1,84 1,84 1,84 1,84 1,84 1,84
1,75 2,32 1,32 1,49 1,65 1,82 1,98 2,15 2,32 2,32 2,32 2,32 2,32 2,32 2,32 2,32 2,32
2,00 2,83 1,59 1,77 1,94 2,12 2,30 2,47 2,65 2,83 2,83 2,83 2,83 2,83 2,83 2,83 2,83
2,25 3,38 1,88 2,06 2,25 2,44 2,63 2,81 3,00 3,19 3,38 3,38 3,38 3,38 3,38 3,38 3,38
2,50 3,95 2,17 2,37 2,57 2,77 2,96 3,16 3,36 3,56 3,76 3,95 3,95 3,95 3,95 3,95 3,95
2,75 4,56 2,49 2,69 2,90 3,11 3,32 3,52 3,73 3,94 4,15 4,35 4,56 4,56 4,56 4,56 4,56
3,00 5,20 2,81 3,03 3,25 3,46 3,68 3,90 4,11 4,33 4,55 4,76 4,98 5,20 5,20 5,20 5,20
3,25 5,86 3,15 3,38 3,61 3,83 4,06 4,28 4,51 4,73 4,96 5,18 5,41 5,63 5,86 5,86 5,86
3,50 6,55 3,51 3,74 3,98 4,21 4,44 4,68 4,91 5,14 5,38 5,61 5,85 6,08 6,31 6,55 6,55
3,75 7,26 3,87 4,12 4,36 4,60 4,84 5,08 5,33 5,57 5,81 6,05 6,29 6,54 6,78 7,02 7,26
4,00 8,00 4,25 4,50 4,75 5,00 5,25 5,50 5,75 6,00 6,25 6,50 6,75 7,00 7,25 7,50 7,75
4,25 8,76 4,64 4,90 5,15 5,41 5,67 5,93 6,18 6,44 6,70 6,96 7,22 7,47 7,73 7,99 8,25
4,50 9,55 5,04 5,30 5,57 5,83 6,10 6,36 6,63 6,89 7,16 7,42 7,69 7,95 8,22 8,49 8,75
4,75 10,35 5,45 5,72 5,99 6,27 6,54 6,81 7,08 7,36 7,63 7,90 8,17 8,45 8,72 8,99 9,26
5,00 11,18 5,87 6,15 6,43 6,71 6,99 7,27 7,55 7,83 8,11 8,39 8,66 8,94 9,22 9,50 9,78
5,25 12,03 6,30 6,59 6,87 7,16 7,45 7,73 8,02 8,31 8,59 8,88 9,17 9,45 9,74 10,02 10,31
5,50 12,90 6,74 7,04 7,33 7,62 7,92 8,21 8,50 8,79 9,09 9,38 9,67 9,97 10,26 10,55 10,85
a) The anchor spacing and the edge distance shall not be smaller than the minimum anchor spacing smin and the
minimum edge distance cmin.
hef/d 12 13 14 15 16 17 18 19 20
0,05 ⋅ (hef / d)
1,68
f hef = 3,25 3,72 4,21 4,73 5,27 5,84 6,42 7,04 7,67
10 / 2012 669
Hilti HIT-HY 150
with rebar
Recommended loads can be calculated by dividing the design resistance by an overall partial safety factor for
action γ = 1,4. The partial safety factors for action depend on the type of loading and shall be taken from national
regulations.
BSt 500 S [kN] 8,5 8,9 12,5 12,6 16,2 22,4 27,7
BSt 500 S [kN] 9,3 14,7 20,7 25,1 32,3 44,9 55,5
BSt 500 S [kN] 5,3 6,0 8,5 9,4 13,0 17,4 21,5
Shear VRd: single anchor, min. edge distance (c = cmin), without lever arm
BSt 500 S [kN] 3,5 4,9 6,6 10,0 13,2 17,4 21,8
BSt 500 S [kN] 5,9 6,2 8,5 8,7 11,1 15,2 19,3
Shear VRd: double anchor, no edge effects, min. spacing (s = smin), without lever arm
BSt 500 S [kN] 9,3 11,4 16,0 16,2 20,9 29,9 40,4
670 10 / 2012
Hilti HIT-HY 150
with rebar
BSt 500 S [kN] 11,4 13,4 19,6 19,6 26,0 38,1 58,9
BSt 500 S [kN] 9,3 14,7 20,7 28,0 36,7 57,3 90,0
BSt 500 S [kN] 7,0 8,3 12,1 13,4 18,8 26,9 37,0
Shear VRd: single anchor, min. edge distance (c = cmin), without lever arm
BSt 500 S [kN] 3,7 5,3 7,3 11,2 15,8 21,5 27,5
BSt 500 S [kN] 8,0 9,3 13,4 13,7 18,0 25,8 40,2
Shear VRd: double anchor, no edge effects, min. spacing (s = smin), without lever arm
BSt 500 S [kN] 9,3 14,7 20,7 23,3 30,8 45,6 72,9
10 / 2012 671
Hilti HIT-HY 150
with rebar
a)
Design resistance: non- cracked concrete C 20/25 - embedment depth = 12 d
Anchor size Ø8 Ø10 Ø12 Ø14 Ø16 Ø20 Ø25
Embedment depth hef = 12 d a) [mm] 96 120 144 168 192 240 300
Base material thickness h = hmin [mm] 126 150 176 204 232 290 364
Tensile NRd: single anchor, no edge effects
BSt 500 S [kN] 13,7 17,8 25,6 26,4 34,5 53,9 84,1
BSt 500 S [kN] 9,3 14,7 20,7 28,0 36,7 57,3 90,0
a)
Design resistance: non- cracked concrete C 20/25 - embedment depth = 12 d
Anchor size Ø8 Ø10 Ø12 Ø14 Ø16 Ø20 Ø25
Embedment depth hef = 12 d a) [mm] 96 120 144 168 192 240 300
Base material thickness h = hmin [mm] 126 150 176 204 232 290 364
Edge distance c = cmin [mm] 40 50 60 80 100 120 135
Tensile NRd: single anchor, min. edge distance (c = cmin)
BSt 500 S [kN] 8,4 11,0 15,8 18,1 24,9 37,9 55,9
Shear VRd: single anchor, min. edge distance (c = cmin), without lever arm
BSt 500 S [kN] 3,9 5,7 7,8 12,0 16,9 23,6 30,5
a)
Design resistance: non- cracked concrete C 20/25 - embedment depth = 12 d
(load values are valid for single anchor)
Anchor size Ø8 Ø10 Ø12 Ø14 Ø16 Ø20 Ø25
Embedment depth hef = 12 d a) [mm] 96 120 144 168 192 240 300
Base material thickness h = hmin [mm] 126 150 176 204 232 290 364
Spacing s = smin [mm] 40 50 60 80 100 120 135
Tensile NRd: double anchor, no edge effects, min. spacing (s = smin)
BSt 500 S [kN] 9,7 12,5 17,9 18,7 24,2 37,3 59,2
Shear VRd: double anchor, no edge effects, min. spacing (s = smin), without lever arm
BSt 500 S [kN] 9,3 14,7 20,7 28,0 36,7 57,3 90,0
a) d = element diameter
672 10 / 2012
Hilti HIT-HY 150
post-installed rebars
Drinking
Corossion
Concrete water
tested
appoved
Approvals / certificates
Description Authority / Laboratory No. / date of issue
Fire test report IBMB Braunschweig 3162/6989 / 1999-07-16
Assessment report (fire) Warringtonfire WF 166402 / 2007-10-26
Materials
Reinforcmenent bars according to EC2 Annex C Table C.1 and C.2N.
830 10 / 2012
Hilti HIT-HY 150
post-installed rebars
Properties of reinforcement
Product form Bars and de-coiled rods
Class B C
Characteristic yield strength fyk or f0,2k (MPa) 400 to 600
1,15
Minimum value of k = (ft/fy)k 1,08
< 1,35
Characteristic strain at maximum force, Huk (%) 5,0 7,5
Bendability Bend / Rebend test
Maximum deviation from Nominal bar size (mm)
nominal mass 8 ± 6,0
(individual bar) (%) >8 ± 4,5
Bond: Nominal bar size (mm)
Minimum relative rib area, 8 to 12 0,040
fR,min > 12 0,056
Setting details
For detailed information on installation see instruction for use given with the package of the product.
10 / 2012 831
Hilti HIT-HY 150
post-installed rebars
a)
a) Note: Manual cleaning for element sizes d d 16mm and embedment depth hef d 10 d only!
832 10 / 2012
Hilti HIT-HY 150
post-installed rebars
These tests show an excellent behaviour of the post-installed connection made with HIT-HY 150: low
displacements with long term stabilisation, failure load after exposure above reference load.
Electrical conductivity
HIT-HY 150 in cured state shows low electrical conductivity. Its electric resistivity is 2.10 :.m
11
(DIN VDE 0303T3). It suits well electrically insulating anchoring (ex: railway applications, subway).
10 / 2012 833
Hilti HIT-HY 150
post-installed rebars
Drilling diameters
Concrete class
Rebar (mm)
C12/15 C16/20 C20/25 C25/30 C30/37 C35/45 C40/50 C45/55 C50/60
8 - 25 1,6 2,0 2,3 2,7 3,0 3,0 3,0 3,0 3,0
0,15
Increasing factor for other concrete class: fB,p=(fcck/25) (fcck: characteristic compressive strength on cube)
834 10 / 2012
Hilti HIT-HY 150
post-installed rebars
Fire Resistance
"inst
a) fire situation “anchorage”
Maximum force in rebar in conjunction with HIT-HY 150 as a function of embedment depth for the fire
resistance classes F30 to F180 (yield strength fyk = 500 N/mm²) according EC2a).
Bar Drill hole Max. Fs,T "inst R30 R60 R90 R120 R180
[mm] [mm] [kN] [mm] [kN] [kN] [kN] [kN] [kN]
80 3,5 1,5 0,6 0,3 0,0
120 10,6 5,0 2,8 1,9 0,7
160 16,2 11,9 7,9 5,2 2,7
8 12 16,2 190 16,2 13,2 10,4 4,7
210 16,2 13,9 6,4
230 16,2 8,5
280 16,2
100 8,8 3,6 1,9 1,1 0,2
150 19,8 12,7 7,7 5,1 2,6
180 25,3 19,3 14,3 10,7 4,9
10 14 25,3 210 25,3 20,6 17,3 7,6
240 25,3 23,9 12,5
250 25,3 14,4
310 25,3
120 15,9 7,5 4,1 2,9 1,0
180 31,7 23,1 17,1 12,9 5,9
200 36,4 28,4 22,4 18,1 8,0
12 16 36,4 240 36,4 32,9 28,7 14,4
260 36,4 34,0 19,7
270 36,4 22,3
330 36,4
140 24,7 14,6 7,9 5,8 2,7
210 44,0 36,2 29,2 24,2 10,6
230 49,6 42,4 35,4 30,4 13,9
14 18 49,6 260 49,6 44,0 39,6 23,0
280 49,6 44,0 29,1
300 49,6 32,2
350 49,6
160 35,2 23,8 15,8 10,4 5,3
240 57,5 51,9 43,9 38,3 19,2
250 64,7 55,5 47,5 41,8 22,7
16 20 64,8 280 64,7 57,5 52,3 33,2
300 64,7 57,5 40,3
320 64,7 47,3
370 64,7
200 61,6 47,3 37,3 30,2 13,3
290 101,2 86,9 76,9 69,8 45,9
330 101,2 94,5 87,4 63,5
20 25 101,2
350 101,2 96,2 72,3
370 101,2 81,1
420 101,2
10 / 2012 835
Hilti HIT-HY 150
post-installed rebars
Bar Drill hole Max. Fs,T "inst R30 R60 R90 R120 R180
[mm] [mm] [kN] [mm] [kN] [kN] [kN] [kN] [kN]
250 104,5 86,6 74,1 65,3 35,4
350 158,1 141,6 129,1 120,2 90,4
380 158,1 145,6 136,7 106,9
25 32 158,1
410 158,1 153,2 123,4
420 158,1 128,9
480 158,1
836 10 / 2012
Hilti HIT-HY 150
post-installed rebars
Minimum anchorage and lap lengths for C20/25; maximum hole lengths
Hammer drilling,
Rebar
Compressed air drilling
Diameter ds fy,k lb,min* l0,min* lmax
[mm] [N/mm²] [mm] [mm] [mm]
8 500 170 300 1000
10 500 213 300 1000
12 500 255 300 1000
14 500 298 315 1000
16 500 340 360 1500
20 500 425 450 2000
25 500 532 563 2000
*lb,min (8.6) and l0,min (8.11) are calculated for good bond conditions with maximum utilisation of rebar yield strength
fyk = 500 N/mm² and D6 = 1,0
10 / 2012 837