Automatic Gas Release

AN ISO 9001:2000 COMPANY- FILE NO: A13166

Solenoid Valve A conventional CD-02 Panel fitted with


Pressure Switch Manual Abort and release Switches
Gas Release Nozzle
and connected to detectors in two
Fire Alarm Panel. zones makes a reliable Gas release
panel.
Optical Detector Ionisation Detector
Extinguishing When an alarm is detected in any
Gas Protected Area. one zone the panel Hooter will sound.
However when one detector in each
zone go into alarm then a
Isolated RS485 Port. To Main panel. programable timer starts a count
Optional down.
NO Contact Timer ON
NO Contact Solenoid ON After the programmed time delay 24v
Manual Pressure
is sent to operate the solenoid
NO Contact Fire Signal
Timer Discharge Solenoid
Abort ON Gas Release Low
ON

operated valve and gas is released in


Stand by
NO Contact Fault Signal
CD-02-GR the protected area.
Main

Gas Release Panel

Addressable Gas Release with Timer


MM-1 Timer Module
An Addressable System
can be used for Gas Solenoid Valve Cross Zone Timer

Z1
release by connecting a Pressure Switch CM-1
combination of Gas Release Nozzle
24v 0v

addressable Monitor and Extinguishing 0v Z2


Power CM-2
Control modules along Gas 0v

with a Timer and Local 24v


Abt+
Ionisation Detector Optical Detector
Power supply 0v
Abt-

Protected Area. 24v DC Solenoid CF


PCD Make timers are Power Supply MM-2
CF
programable in steps of 2 Wire Addressable Loop
15 seconds up to 225
seconds. They are Break Glass release & abort switches.
microprocessor based Break Glass switches with Built in LED are provided
and have built in under for Manual release and Abort functions. These
voltage and brown out switches ensure that accidental release does not
protection, The Input occur. The Break Glass is of the Press to break
section has dual inputs type and can be reset by replacing the Glass
with cross zone detection

Ionization
Detector Addressable Gas Release
Optical
Detector with ZM-02 Module
An addressable Gas
release system with
Conventional detectors,
Manual
Manual release, abort
Release switches etc can be
connected to form an
Manual economically priced Gas
Abort
release Panel. This ideal
Discharge for multi zone protection
Solenoid systems. All Cables
Gas
Discharged originating from this panel
are monitored for open
Alert and short circuit. Two
Hooter
Evacuate hooter outputs are
Hooter provided for Dual stage
alarms.