C ATA LO G
START
—
Providing sustainable solutions
for renewables
1 3
Solar
2
Wind
3
Energy Storage System
2
4
EV charging
START
BACK NEXT
—
Delivering sustainable
renewables
Power
generation
Monitoring Balance of
& Control System (BoS)
We understand the complexity of implementing solutions that are both sustainable and future-proof.
START
BACK NEXT
—
Digitalization for renewables
through ABB Ability™
ABB Ability™ is our unified, cross-industry digital solution, giving
you the ability to know more, do more, do better, together. Automation and Service and asset
ABB Ability™ is built on a state of- the-art hardware and software digitalization management
architecture for data collection, processing and storage, which has been
developed together with Microsoft in order to enhance performance and
guarantee the highest reliability and security.
Our leading integrated and collaborative digital solutions build on our knowledge and
expertise in renewables, which contributes to:
• Maximized service continuity through smart • Reduction of more than 60% of installed
algorithms, even in an emergency components for the same function
• Savings of up to 30% on operational costs • Switchgear footprint reduction
DC AC Other Power Grid
through energy management system of up to 50% by embedding logics
products collection connection
START
BACK NEXT
—
Benefits and advantages
for photovoltaic
Systems, products and solutions answering customers needs and market trends.
ABB portfolio for photovoltaic applications focus on delivering continuous operation,
higher reliability and return on investments, enabling customers to take full advantage
of savings by adopting 1500V DC and 800V AC technologies.
— — — — — —
Reduced costs and resources Energy efficiency Reliable in extreme conditions Continuous operation Global availability Speed up your projects
Challenge/trend Hidden costs are Challenge/trend The demand for lower Challenge/trend Solar plants are Challenge/trend Keeping priority loads Challenge/trend Having the ability to Challenge/trend An optimized
typically neglected, but they solar energy cost and higher efficiency commonly located in high temperature running during an utility outage is streamline operations and serve manufacturing operation can provide
significantly impact any business. have pushed higher voltages and more environments or at high altitudes, crucial for business continuity. multiple markets are survival factors in that extra advantage needed to secure
energy efficient equipment: requiring equipment that can work such a competitive market. projects.
ABB answer Simplified bidding and 800V AC: properly under harsh conditions: ABB answer ABB’s power manager
negotiation costs with one single 14% savings in transformer up to 70°C or 5000 m altitude. capabilities allow continuous operation ABB answer ABB’s multi-listed ABB answer ABB’s factory accessorized
supplier thanks to ABB’s complete copper windings of critical loads when an outage (eg.: IEC/UL/CCC and more) products products and easy-to-install
sun-to-socket offering can save up to 1500V DC: ABB answer ABB’s offering is designed happens in the utility side and and systems allow customers to export accessories save up to 15% in
50% in time. 35% savings on arrays in parallel taking into account the specific renewables are present. one single design virtually anywhere in installation and commissioning time.
33% savings on array components. application requirements to deliver the the world.
most reliable solution with high
ABB answer ABB’s complete offering performance without deratings
helps increase the “Electrical Balance of the main characteristics:
of System” efficiency related to power up to 55°C or 4000 m altitude.
losses by up to 35%, allowing more
power to be delivered to the consumer.
START
BACK NEXT
—
Solar power
1 DC
2 AC
3 Power collection
4 Grid connection
START
BACK NEXT
—
Application overview
Residential system ≤20kW LV
1 6 UTF-certified
measurement group
2 for produced energy
Id kWh Id kWh
ID
Energy meter at
connection point
3 4 5 7 8 9 10
Low-voltage products:
1. Rapid Shutdown 2.0 4. Surge protection devices: OVR PV QS
2. String boxes 5. Residual current devices: F202B, F204B
Switchboards: Gemini 6. Energy meters: EQmeters and current transformers
Consumer units: MISTRAL65H 7. Contactors: AF Series
Circuit breakers: S200 M UC Z, S800 PV-SP Grid-feeding monitoring relays: CM-UFD.MxxM
Fuse disconnectors: E 90 PV Power supplies: CP-x
Fuses: E 9F PV 8. Fuse disconnectors: E 90
Spring and screw terminal blocks: SNK PI 9. Surge protective devices: OVR T1 / T1-T2 / T2 QS
3. Switch-disconnectors: OTDC, S800 PV-SD 10. Residual current circuit breakers: DS202C
START
BACK NEXT
RESIDENTIAL COMMERCIAL / INDUSTRIAL UTILITY
DC AC OTHER PRODUCTS
—
Protection and safety
MISTRAL65H E90 PV Fuse Holders and fuses OVR PV High-performance string protection
Strong, resistant and with a modern The E90 PV fuse holders have been Surge Protective Devices are now well MCB S800PV-SP
look, MISTRAL65H is the most specifically designed for photovoltaic integrated in the solar system to The High-Performance MCB S800PV-SP,
innovative series of IP65 rated applications. Thanks to their rated protect DC and AC sides with the aim specially developed for photovoltaic
consumer units, designed to reduce voltage up to 1500V DC, they are to provide continuity of service and systems, offers reliable protection for
cabling times as well as allow total perfect for protection of strings in PV reduce risk of fire, protecting from PV modules and lines against reverse
integration between modular DIN-rail applications. Their compact size is overvoltages due to lightning strikes or currents from defective strings and AC
and front panel devices. Thanks to the perfect for installation in a string network disturbances. We designed the regenerative feedback due to defective
elegant design, MISTRAL65H can be combiner box or in an inverter. OVR PV to improve performance and inverters. The high demands of PV
installed in residential environments E90 PV can be used in combination protect any photovoltaic system systems have been considered a
where high level of IP protection is with E9F PV cylindrical fuses for 1000 according to IEC 61643-31 Standard. priority in the development of the
required. or 1500V DC. S800PV-SP.
START
BACK NEXT
RESIDENTIAL COMMERCIAL / INDUSTRIAL UTILITY
DC AC OTHER PRODUCTS
—
Switch and disconnection
START
BACK NEXT
RESIDENTIAL COMMERCIAL / INDUSTRIAL UTILITY
DC AC OTHER PRODUCTS
—
Metering, monitoring and installation
CMS-660 - Solar string monitoring Insulation monitoring relays Conduit & fittings Metal framing & support systems
How can you detect impairments such The insulation monitoring relays of the An electrical system is as reliable as its ABB saves time and labor with its
as leaves and dirt or even broken cables CM-IWx range guarantee a continuous conductors and conduit comprehensive lines of metal framing
without great effort? insulation monitoring of an IT system. systems & fittings, which provide and cable tray, including the industry’s
CMS-660 is a solar monitoring system The devices recognize insulation faults unsurpassed protection for wires and only 100% plated products, our 1 1/2"
that remotely checks the DC current as they develop and trip immediately if cables in any demanding applications: modular system and hundreds of
produced by each string, allowing to the value falls below the minimum set power generation and solar panels. accessories to complete any job.
compare it not only with its previous threshold. This ensures a reliable
performance but also with the operation of the system and prevents
performance of other strings. operational interruption caused by a
CMS allows detection of over-voltages, second, more severe, insulation fault
breaker trips or high temperatures. which may lead to a short-circuit trip of
the main circuit-breaker.
START
BACK NEXT
RESIDENTIAL COMMERCIAL / INDUSTRIAL UTILITY
DC AC OTHER PRODUCTS
—
Protection and safety
START
BACK NEXT
RESIDENTIAL COMMERCIAL / INDUSTRIAL UTILITY
DC AC OTHER PRODUCTS
—
Protection and safety
START
BACK NEXT
RESIDENTIAL COMMERCIAL / INDUSTRIAL UTILITY
DC AC OTHER PRODUCTS
—
Switch and disconnection
START
BACK NEXT
RESIDENTIAL COMMERCIAL / INDUSTRIAL UTILITY
DC AC OTHER PRODUCTS
—
Switch and disconnection
START
BACK NEXT
RESIDENTIAL COMMERCIAL / INDUSTRIAL UTILITY
DC AC OTHER PRODUCTS
—
Metering, monitoring and installation
Energy Meters Circuit Measurement Systems Grid feeding monitoring relays System pro E comfort MISTRAL
Energy consumption awareness is key With the rise of digitalization and the CM-UFD ABB's series of consumer units
to reduce energy costs and improve Internet of Things (IoT), data collection ABB’s CM-UFD range are multi- combine versatility and performance
energy efficiency on your machines from the entire network for analysis functional grid feeding monitoring with an elegant design, reducing
and electrical assets. Energy meters becomes easier, enabling optimization relays, installed between the renewable installation time while integrating
allow to identify areas for of energy usage and assets. energy system and the public grid. several kinds of devices for DIN-rail and
improvement and to generate From monitoring energy consumption They detect unusual events in the devices to be installed on mounting
benefits for owners, facility managers to control of operations and costs, public power grid and automatically plate or on blind front panels. With the
and users. They enable to run smarter connectivity-based solutions can disconnect and reconnect the wide range of sizes and versions, ABB’s
buildings in a more energy and cost improve energy efficiency while renewable power plant. consumer units are one of the most
efficient way. reducing costs. complete ranges on the market,
providing a smarter space for all your
installation ideas.
START
BACK NEXT
RESIDENTIAL COMMERCIAL / INDUSTRIAL UTILITY
DC AC OTHER PRODUCTS
MC4-Evo2 photovoltaic connectors Ty-Rap high performance cable ties Wire termination & connectors External Lightning Protection - OPR
MC4-Evo2 PV connectors are the latest Innovative design and engineered ABB is a recognized leader in providing To provide effective protection, the
generation of MC4 PV connectors. materials make Ty-Rap® cable ties the electrical connectors suitable for the Solar system must be protected
ABB proposes a complete range of perfect fastening solution where majority of all electrical applications. against direct lightning strikes and
connectors including plug connectors, performance really matters. have a proper grounding system in
panel receptacles and branch Often imitated but never equaled, addition to protection against
connectors. Ty-Rap® cable ties provide superior overvoltage on both sides of the
performance in any application. inverter. OPR, ESE lightning rod is an
active system that protects against
direct lightning.
START
BACK NEXT
—
Application overview
Commercial system 20-1000 kW LV/MV
2 3 9 5 8 13 14 15
1
Loads
10 11 16 14
7
Id kWh Id kWh
ID
8 5 12 17 18 B C
A
kWh
6 Low-voltage products:
1. String combiners 1000V DC 15. Contactors: AF Contactor Series
Switchboards: Gemini; Consumer units: MISTRAL65H, Gemini Grid-feeding monitoring relays: CM-UFD.MxxM
2. Fuse disconnectors: E 90 PV; Fuses: E 9F PV Power supplies: CP-x
kWh
3. Switch-disconnectors: OTDC; S800 PV-SD 16. Energy meters: EQ meters and current transformers
4. Current measurement system: CMS; Power supplies: CP-x 17. Surge protective devices: OVR T1 / T1-T2 / T2 QS ID+GPD
5. Surge protection devices: OVR PV QS 18. Fuse disconnector: E 90
6. String monitoring controller 19. GSM telephone actuator: ATT
7. Recombiner
8. Miniature circuit breakers: S200 M UC Z, S800 PV-SP Medium-voltage products: Loads
4 5 9. Switch-disconnectors: Tmax PV, OTDC series A. Modular Systems: Compact Secondary Substation, D 19
10. Contactors: GAF Series + IOR Series rail contactor Secondary Skid Unit, Secondary Enclosed Unit
11. Insulation monitoring devices: CM-IWx B. Transformers: Dry-type transformers,
12. GFDI Application: S804U-PVS5 oil-immersed transformers
13. Residual current devices: F202B, F204B C. Gas-insulated secondary switchgear: SafeRing / Safeplus
14. Residual current blocks: DDA 200 B Air-insulated secondary switchgear: UniSec
Residual current circuit breakers: F200 type B Air-insulated switch-disconnector: NALF
Miniature circuit breakers: S 200 Recloser: Gridshield®
Moulded case circuit breakers: Tmax XT, Tmax T, Circuit breaker: VD4
Tmax XT RCD BType D. Interface protection system: ABB Relion® Family
START
BACK NEXT
RESIDENTIAL COMMERCIAL / INDUSTRIAL UTILITY
—
Protection and safety
String combiner boxes GEMINI E90 PV Fuse Holders and fuses OVR PV
In a photovoltaic system, the modules The E90 PV fuse holders have been Surge Protective Devices are now well
are arranged in strings and arrays specifically designed for photovoltaic integrated in the solar system to
depending on the type of inverter used, applications. Thanks to their rated protect DC and AC sides with the aim
the total power and the technical voltage up to 1500V DC, they are to provide continuity of service and
characteristics of the modules. ABB perfect for protection of strings in PV reduce risk of fire, protecting from
offers a complete range of all-in-one applications. Their compact size is overvoltages due to lightning strikes or
combiner boxes hosting string optimal for installation in a string network disturbances. We designed the
protection devices, disconnectors and combiner box or in an inverter. OVR PV to improve performance and
surge protective devices (SPDs). E90 PV can be used in combination protect any photovoltaic system
It is possible to add also monitoring with E9F PV cylindrical fuses for 1000 according to IEC 61643-31 Standard.
devices. or 1500V DC.
START
BACK NEXT
RESIDENTIAL COMMERCIAL / INDUSTRIAL UTILITY
—
Protection and safety
START
BACK NEXT
RESIDENTIAL COMMERCIAL / INDUSTRIAL UTILITY
—
Switch and disconnection
START
BACK NEXT
RESIDENTIAL COMMERCIAL / INDUSTRIAL UTILITY
—
Metering, monitoring and installation
CMS-660 - Solar string monitoring Insulation monitoring relays Conduit & fittings Metal framing & support systems
How can you detect impairments such The insulation monitoring relays of the An electrical system is as reliable as its ABB saves time and labor with its
as leaves and dirt or even broken cables CM-IWx range guarantee a continuous conductors and conduit comprehensive lines of metal framing
without great effort? insulation monitoring of an IT system. systems & fittings, which provide and cable tray, including the industry’s
CMS-660 is a solar monitoring system The devices recognize insulation faults unsurpassed protection for wires and only 100% plated products, our 1 1/2"
that remotely checks the DC current as they develop and trip immediately if cables in any demanding applications: modular system and hundreds of
produced by each string, allowing to the value falls below the minimum set power generation and solar panels. accessories to complete any job.
compare it not only with its previous threshold. This ensures a reliable
performance but also with the operation of the system and prevents
performance of other strings. operational interruption caused by a
CMS allows detection of over-voltages, second, more severe, insulation fault
breaker trips or high temperatures. which may lead to a short-circuit trip of
the main circuit-breaker.
START
BACK NEXT
RESIDENTIAL COMMERCIAL / INDUSTRIAL UTILITY
—
Protection and safety
OVR QuickSafe® E90 50A/125A Miniature circuit-breakers - MCBs Residual current devices - RCDs
QuickSafe is our new generation of Fuse switch-disconnectors Miniature circuit-breakers ensure Residual current devices protect people
Surge Protective Devices (SPD) with The E 90 50A/125A fuse switch electrical safety in multiple from life-threatening indirect contacts
improved performance. Thanks to disconnectors range for cylindrical applications. They have two different according to IEC/EN 61008 or
innovative technology this new range fuses 14x51mm and 22x58mm, is tripping mechanisms, the delayed IEC/EN 61009 Standards. ABB offers a
of SPDs covers residential and specifically designed to provide thermal tripping mechanism for comprehensive range of devices like
industrial applications with an protection against short-circuits and overload protection and the magnetic RCCBs, RCBOs, RCD-blocks, Earth
extremely good protection level, simple overloads. It is available in a complete tripping mechanism for short-circuit Leakage Relays DIN-Rail and front
installation and preventive range from 1 to 4 poles and provides protection. panels in order to cope with all the
maintenance. All according to disconnection properties according applications in residential, commercial
IEC/EN 61643-11 Standard. to IEC 60947-3 Standard. and industrial segments.
START
BACK NEXT
RESIDENTIAL COMMERCIAL / INDUSTRIAL UTILITY
—
Protection and safety
START
BACK NEXT
RESIDENTIAL COMMERCIAL / INDUSTRIAL UTILITY
—
Switch and disconnection
START
BACK NEXT
RESIDENTIAL COMMERCIAL / INDUSTRIAL UTILITY
—
Metering, monitoring and installation
Energy Meters Circuit Monitoring Systems Grid feeding monitoring Gemini multipurpose enclosures
Energy consumption awareness is key With the rise of digitalization and the relays CM-UFD Gemini switchboards are made through
to reduce energy costs and improve Internet of Things (IoT), data collection ABB’s CM-UFD range are multi- co-injection technology and ABB is the
energy efficiency on your machines from the entire network for analysis functional grid feeding monitoring first manufacturer to use it as a
and electrical assets. Energy meters becomes easier, enabling optimization relays, installed between the renewable molding technique. This process
allow to identify areas for of energy usage and assets. energy system and the public grid. obtains a compact external hard
improvement and to generate From monitoring energy consumption They detect unusual events in the covering and an expanded internal soft
benefits for owners, facility managers to control of operations and costs, public power grid and automatically core, guaranteeing the highest level of
and users. They enable to run smarter connectivity-based solutions can disconnect and reconnect the mechanical protection against impacts
buildings in a more energy and cost improve energy efficiency while renewable power plant. (IK10). Gemini keeps its mechanical
efficient way. reducing costs. characteristics in the long term.
START
BACK NEXT
RESIDENTIAL COMMERCIAL / INDUSTRIAL UTILITY
START
BACK NEXT
RESIDENTIAL COMMERCIAL / INDUSTRIAL UTILITY
START
BACK NEXT
RESIDENTIAL COMMERCIAL / INDUSTRIAL UTILITY
MC4-Evo2 photovoltaic connectors Metal framing & support systems Cable protection and insulation External Lightning Protection - OPR
MC4-Evo2 PV connectors are the latest ABB saves time and labor with its ABB offers a wide range of products to To provide effective protection, the
generation of MC4 PV connectors. comprehensive lines of metal framing guide, protect and insultate your wires Solar system must be protected
ABB proposes a complete range of and cable tray, including the industry’s and cables in your control panels and against direct lightning strikes and
connectors including plug connectors, only 100% plated products, our 1 1/2" equipment. Our range includes braided have a proper grounding system in
panel receptacles and branch modular system and hundreds of sleeving, extruded grommeting, addition to protection against
connectors. accessories to complete any job. heatshrink and spiral wrap. overvoltage on both sides of the
inverter. OPR, ESE lightning rod is an
active system that protects against
direct lightning.
START
BACK NEXT
—
Application overview
Utility scale system 1000 kW MV/HV - CENTRAL INVERTERS - Low-voltage products
To next
inverter
11 16
1 2 3
4
12 15
3
9
Id
ID+GPD
6
14 13
8
7 10
8 Low-voltage products:
1. Fuse disconnectors: E 90 PV; Fuses: E 9F PV 9. Switchboards: System pro E power
2. Current measurement system: CMS 10. Insulation monitoring devices: CM-IWx ID+GPD
3. Switch-disconnectors: OTDC 11. Contactors: GF and GAF series
4. String combiners: 1000V DC/1500V DC 12. GFDI Application: S804U-PVS5
Switchboards: Gemini 13. Fuse disconnectors: E 90
5 3 5. Surge Protection Devices: OVR PV QS 14. Surge protection devices: OVR T1 / T1-T2 / T2 QS
6. String Monitoring Controller 15. Contactors: AF Series
7. Recombiner 16. Moulded case circuit breakers: Tmax XT, Tmax T
8. Moulded Case Circuit Breakers: Tmax PV Air circuit breakers: Emax 2
START
BACK NEXT
—
Application overview
Utility scale system 1000 kW MV/HV - CENTRAL INVERTERS - Medium-voltage products
To next
inverter
C G G
A F
E
Id
ID+GPD
B D
Medium-voltage products: D
A. eHouse E. Modular Systems: Compact Secondary Substation,
B. Transformers: Dry-type transformers, Secondary Skid Unit, EcoFlex eHouse ID+GPD
oil-immersed transformers F. EcoFlex, eHouse, skid-mounted substation
C. Gas-insulated secondary switchgear: SafeRing / Safeplus G. Gas-insulated primary switchgear: ZX product family
Air-insulated secondary switchgear: UniSec Air-insulated primary switchgear: UniGear product family
Air-insulated switch-disconnector: NALF Air-insulated secondary switchgear: UniSec
Recloser: Gridshield Outdoor breakers: R-MAG® (dead tank), OVB-VBF (life tank)
Circuit breaker: VD4 Recloser: Gridshield
D Interface protection system: ABB Relion® Family, REG615
START
BACK NEXT
—
Application overview
Utility scale system 1000 kW MV/HV - STRING INVERTERS - Low-voltage products
Low-voltage products:
1 1. String Combiner 10. Moulded Case Circuit Breakers: Tmax XT
2. Molded Case Circuit Breakers Tmax PV (e.g. T4N/PV-E) 11. Insulation monitoring devices: CM-IWx
3. Recombiner 12. Switch Fuse (up to 690V AC): OS
4 4. Fuse Switch Disconnectors: InLine II ZLBM and EasyLine XLP 13. Contactors: AF seriesv
5. Molded Case Circuit Breakers for AC applications 14. GFDI Application: S804U-PVS5
(e.g. T4V-HA) 15. Switch-disconnectors: OT
3 6. Switchboard 16. Fuse disconnectors: E 90
7. Molded Case Circuit Breakers for AC applications 17. Surge protection devices: OVR T1 / T1-T2 / T2 QS
(e.g. T5V-HA) 18. Moulded case circuit breakers: Tmax XT, Tmax T
8. Switch Disconnectors Fuse: SlimLine XR Air circuit breakers: Emax 2
9. Switchboards: System pro E power
11 12 13 15
7
6
To next
17 inverter
Id
ID+GPD
2 5
17 16
10 18
ID+GPD
START
BACK NEXT
—
Application overview
Utility scale system 1000 kW MV/HV - STRING INVERTERS - Medium-voltage products
Medium-voltage products:
A. Modular Systems: Compact Secondary Substation, D Interface protection system: ABB Relion® Family, REG615
Secondary Skid Unit, EcoFlex eHouse E. EcoFlex, eHouse, skid-mounted substation
B. Transformers: Dry-type transformers, F. Gas-insulated primary switchgear: ZX product family
oil-immersed transformers Air-insulated primary switchgear: UniGear product family
C. Gas-insulated secondary switchgear: SafeRing / Safeplus Air-insulated secondary switchgear: UniSec
Air-insulated secondary switchgear: UniSec Outdoor breakers: R-MAG® (dead tank), OVB-VBF (life tank)
Air-insulated switch-disconnector: NALF Recloser: Gridshield
Recloser: Gridshield
Circuit breaker: VD4
To next
inverter
C F F
A E
Id
ID+GPD
B D
ID+GPD
START
BACK NEXT
RESIDENTIAL COMMERCIAL / INDUSTRIAL UTILITY
—
Protection and safety
String combiner boxes GEMINI E90 PV Fuse Holders and fuses OVR PV S800PV Ground Fault Detector
In a photovoltaic system, the modules The E90 PV fuse holders have been Surge Protective Devices are now well Interrupter
are arranged in strings and arrays specifically designed for photovoltaic integrated in the solar system to S800PV is used for GFDI application
depending on the type of inverter used, applications. Thanks to their rated protect DC and AC sides with the aim (Ground-Fault Detector Interrupter) in
the total power and the technical voltage up to 1500V DC, they are to provide continuity of service and photovoltaic systems. The
characteristics of the modules. ABB perfect for protection of strings in PV reduce risk of fire, protecting from S804PV-SP5, S804U-PVS5 and S804U-
offers a complete range of all-in-one applications. Their compact size is overvoltages due to lightning strikes or PVSP5 provide ground fault protection
combiner boxes hosting string optimal for installation in a string network disturbances. We designed the according to IEC60947-2 for 1500 VDC,
protection devices, disconnectors and combiner box or in an inverter. OVR PV to improve performance and UL489B for 1000 VDC and UL489B
surge protective devices (SPDs). E90 PV can be used in combination protect any photovoltaic system (recognized) for 1500 VDC. In case of a
It is possible to add also monitoring with E9F PV cylindrical fuses for 1000 according to IEC 61643-31 Standard. ground fault, the breaker will trip, so
devices. or 1500V DC. that the PV generator will not be
damaged.
START
BACK NEXT
RESIDENTIAL COMMERCIAL / INDUSTRIAL UTILITY
—
Switch and disconnection
START
BACK NEXT
RESIDENTIAL COMMERCIAL / INDUSTRIAL UTILITY
—
Metering, monitoring and installation
CMS-660 - Solar string monitoring Insulation monitoring relays Conduit & fittings Metal framing & support systems
How can you detect impairments such The insulation monitoring relays of the An electrical system is as reliable as its ABB saves time and labor with its
as leaves and dirt or even broken cables CM-IWx range guarantee a continuous conductors and conduit comprehensive lines of metal framing
without great effort? insulation monitoring of an IT system. systems & fittings, which provide and cable tray, including the industry’s
CMS-660 is a solar monitoring system The devices recognize insulation faults unsurpassed protection for wires and only 100% plated products, our 1 1/2"
that remotely checks the DC current as they develop and trip immediately if cables in any demanding applications: modular system and hundreds of
produced by each string, allowing to the value falls below the minimum set power generation and solar panels. accessories to complete any job.
compare it not only with its previous threshold. This ensures a reliable
performance but also with the operation of the system and prevents
performance of other strings. operational interruption caused by a
CMS allows detection of over-voltages, second, more severe, insulation fault
breaker trips or high temperatures. which may lead to a short-circuit trip of
the main circuit-breaker.
START
BACK NEXT
RESIDENTIAL COMMERCIAL / INDUSTRIAL UTILITY
—
Protection and safety
Residual current devices - RCDs OVR QuickSafe® SACE Emax 2/E9 Tmax T4V-HA, T5V-HA and T5X-HA
Residual current devices protect people QuickSafe is our new generation of • Smart, plug-and-play architecture, Tmax PV can be used in plants with
from life-threatening indirect contacts Surge Protective Devices (SPD) with easy to use voltage up to 800V AC and do not
according to IEC/EN 61008 or improved performance. Thanks to • The best performance up to 900V of require derating in voltages and
IEC/EN 61009 Standards. innovative technology this new range any device on the market breaking capacity up to 4000m.
ABB offers a comprehensive range of of SPDs covers residential and • The first smart circuit-breaker that SACE Tmax PV T4V-HA, T5X-HA and
devices like RCCBs, RCBOs, RCD-blocks, industrial applications with an enables direct communication with T5V-HA circuit-breakers for AC
Earth Leakage Relays DIN-Rail and front extremely good protection level, simple ABB Ability™ EDCS applications are available in UL,
panels in order to cope with all the installation and preventive • Emax 2/E9 all-in-one is the most IEC 60947-2 and GB14048.2 versions.
applications in residential, commercial maintenance. All according to compact circuit-breaker on the market The T4V-HA bearing the three UL,
and industrial segments. IEC/EN 61643-11 Standard. IEC and CCC marks and T5V-HA bearing
both the IEC and UL marks, while
T5X-HA fulfils the UL 489 requirements
START
BACK NEXT
RESIDENTIAL COMMERCIAL / INDUSTRIAL UTILITY
—
Switch and disconnection
Switches Fusegear
The switch family consists of a complete The 800V AC ratings for InLine II,
range of switch-disconnectors, switch EasyLine XLP and SlimLine XR ranges
fuses, change-over switches, automatic are the latest technological update,
transfer switches, bypass switches, cam boosting our Fusegear portfolio
switches and fuses. performance and making the range a
ABB’s switches are designed for flexibility leading-edge solution that anticipates
and reliable performance in a wide variety market trends.
of applications: power distribution for
residential and industrial buildings, HVAC,
water pumping stations, data centers and
photovoltaic installations.
START
BACK NEXT
RESIDENTIAL COMMERCIAL / INDUSTRIAL UTILITY
—
Metering, monitoring and installation
Energy Meters Circuit Monitoring Systems Grid feeding monitoring relays Power supplies
Energy consumption awareness is key With the rise of digitalization and the CM-UFD The CP range offers the newest
to reduce energy costs and improve Internet of Things (IoT), data collection ABB’s CM-UFD range are multi- technology in a compact construction
energy efficiency on your machines from the entire network for analysis functional grid feeding monitoring of power supplies. Modern power
and electrical assets. Energy meters becomes easier, enabling optimization relays, installed between the renewable supply units are a vital component in
allow to identify areas for of energy usage and assets. energy system and the public grid. They most areas of energy management and
improvement and to generate From monitoring energy consumption detect unusual events in the public automation technology. ABB pays the
benefits for owners, facility managers to control of operations and costs, power grid and automatically utmost attention to the resulting
and users. They enable to run smarter connectivity-based solutions can disconnect and reconnect the requirements. Innovation is the key to a
buildings in a more energy and cost improve energy efficiency while renewable power plant. substantial enlargement of our power
efficient way. reducing costs. supply product program.
START
BACK NEXT
RESIDENTIAL COMMERCIAL / INDUSTRIAL UTILITY
START
BACK NEXT
RESIDENTIAL COMMERCIAL / INDUSTRIAL UTILITY
START
BACK NEXT
RESIDENTIAL COMMERCIAL / INDUSTRIAL UTILITY
Main distribution enclosures Low voltage switchgear External Lightning Protection - OPR Scalable Electrical Monitoring
System pro E power is the innovative At the core of ABB low-voltage To provide effective protection, the and Control Systems
ABB’s main distribution switchboard solutions is the MNS solution platform Solar system must be protected This solution leverages and maximizes
solution with rated current up to 6300A which, in the age of Industry 4.0, has against direct lightning strikes and ABB portfolio across medium- and
and short-circuit current up to 120kA. integrated capabilities to sense, collect have a proper grounding system in low-voltage segments.
Designed to easily fulfill all electrical and analyze the current and upcoming addition to protection against The deployed products are diverse in
installation requirements in terms of condition of the electrical assembly overvoltage on both sides of the nature and include EkipUp units, ABB
protection degree, segregation form through ABB Ability™ inverter. OPR, ESE lightning rod is an AbilityTM EDCS, COM600, ABB zenon
and electrical characteristics, active system that protects against Energy Edition, AC500, AC800M
according to the latest international direct lightning. together with ABB Relion/legacy relays,
Standards and in perfect synergy with 3rd party devices, MV, LV switchgear
all ABB low-voltage equipment. and associated systems, using
communication protocols and
Standards such as IEC 61850, Modbus,
IEC 60870-5, Profibus and OPC.
START
BACK NEXT
—
ABB Ltd.
Affolternstrasse 44
CH-8050 Zurich
Switzerland
https://new.abb.com/low-voltage/industries/solar
9AKK107492A3196 - 05.2019
The information contained in this document is for general information purposes only.
While ABB strives to keep the information up to date and correct, it makes no representations
or warranties of any kind, expressed or implied, about the completeness, accuracy, reliability,
suitability or availability with respect to the information, products, services, or related graphics
contained in the document for any purpose. Any reliance placed on such information is therefore
strictly at your own risk.
ABB reserves the right to discontinue any product or service at any time.
© Copyright 2019 ABB. All rights reserved.