USE THIS CHECKLIST AS A GUIDE WHEN PREPARING SHOP DRAWINGS

SHOP DRAWING GUIDELINES

Name and location of project and name ROOF PLAN Vinyl weatherseal
of roofing installer printed on every page
Substructure, open framing purlins,
INSTALLATION INSTRUCTIONS Roof plan shows all roof slopes solid sheathing

Written instructions for the general Berridge panel system(s) called out Underlayment type called out and
handling and installation of panels, on roof plan locations shown
flashing, underlayment and fasteners
(Berridge has produced such Roof plan shows all roof penetrations Additional layers of underlayment
instructions for its roofing systems (plumbing stacks etc.) required at eave, valley, gable, etc.
and with a degree of modification can refer to Berridge typical details
be tailored to meet the requirements of Detail section cuts called out for every
individual projects) detail Flashings and counter flashings

UNDERLAYMENT PANEL(S) OVERVIEW Flashing laps called out to a minimum


of 4”, 12” for valleys
Underlayment details showing type of Section of panel with dimensions of
underlayment, method of installation panel, seams, type of clip or continuous Laps caulked w/ Tremco Spectrem
and how underlayment is installed rib and type of vinyl weatherseal One caulking.
in relationship to flashings, decking,
blocking, etc. (Berridge has produced DETAILS
such details for its roofing systems and Spacing of fasteners at flashings
with a degree of modification can be Each detail shall show and
tailored to meet the requirements of have explanatory notes on the Any field work such as cutting or forming
individual projects) following: of panels or flashings

Panel system All components required to produce a


functional and aesthetically pleasing
Type of clip or continuous rib (2 clips roof system
are required at eave and valley)

The panel and underlayment requirements will be determined during the Berridge Manufacturing Co.
review of the Architectural drawings. Please refer to these requirements during your production of shop
drawings. Submit (2) sets of shop drawings along with an Application Form for a Berridge Watertightness
Warranty for review and approval.

Shop drawings must show the relationship between the roof panel, panel clips/rib, flashings, fasteners,
underlayment, caulking, penetrations the building, and all areas of the roof.

Technical, Submittals, Procedures, Inspectors, & Training: Pricing, Sales, or Credit Inquiries:
BMC Houston - WTW Department BMC San Antonio - Sales Department
Phone: (800) 231-8127 Phone: (800) 669-0009
Local: (713) 223-4971 Local: (210) 650-3050
Fax: (713) 236-9422 Fax: (210) 650-0379
Email: BMCWatertightDept@Berridge.com Email: Sales@Berridge.com