Download as pdf or txt
Download as pdf or txt
You are on page 1of 62

Head

EVAC MANUALS

ppAGE
DALIAN SHIPBUILDING
INDUSTRY CO.,LTD 1. VACUUM TOILET
EVAC VACUUM TOILET SYSTEM . TECHNICAL DATA
. INSTALLATION
. OPERATION AND MAINTENANCE
. TROUBLE SHOOTING
. SPARE PARTS

USERS HANDBOOK
CS4250 SERIES VESSELS
2. COLLECTING UNITS
COMPONENTS
. TECHNICAL DATE
. INSTALLATION
. OPERATION & MAINTENANCE
. TROUBLE SHOOTING
. SPARE PARTS
Delivery year :2006
EVAC Project : CS4250

3. DRAWINGS
. ELECTRICAL DRAWINGS
Postal address
EVAC OY
Veininlaaksontie 1
FIN-02620 ESPOO
FINLAND

Telephone
358-20 7630 200
Telefax
358-20 7630 222

Email
Evac,marine@evac.fi
Internet
www.evacgroup.com
EVAC Date: 20 Dec 2004 Doc. 5:01001C
Environmental Solutions Marine Sector PIPING

PIPING
DESIGN AND INSTALLATION

1. General system description

In vacuum systems sewage transport is done by vacuum (air) instead of water and gravity. Sewage is transported in
"slugs". Optimal "slug" transport is obtained by following these Design and Installation instructions.

System capacity must be dimensioned considering normal daily variations in use and different operation conditions.

System load (flushings) should be divided evenly between main lines. Ships pitch, a roll and trim shall be considered
in horizontal pipe design to prevent sewage back flow. The best horizontal transport solution is obtained with sloped
pipe, transport pocket at interval of 25 - 30m and/or non-return valve. Piping shall be designed so that possible clogging
or maintenance is not stopping the whole system. System pipe tightness must be tested, documented and maintained
for good system operation and low energy consumption. Piping shall be accessible and divided in sections for easy
maintenance.

Ventilation

Vent pipe
Vacuum interface valve
Urinal

Exhaust-air Main line


pipe Non-return valve

Inspection opening
Transport pocket

Vacuum Shore
interface valve connection

Vacuum gauge Main line valve


Sloped Pressure Air inlet valve
min. 1:20 switch
Inlet manifold
Over flow pipe Shut-off valve
Ejector Discharge valve

Pump Connection to a
Collecting unit * sewage treatment
plant or holding tank

*) The collecting unit can be based on Evac ejector system, where the collecting tank
is under atmospheric pressure, or on Evac vacuum tank system, or On-line vacuum
generating system.

EVAC reserves the right to make alterations to this specification without prior notice.
© Copyright Evac Oy. All rights reserved. 2
1. VACUUM TOILET
. TECHNICAL DATA
. INSTALLATION
. OPERATION AND MAINTENACE
. TROUBLE SHOOTING
. SPARE PARTS
3. ELECTRICAL DRAWINGS
. ELECTRICAL DRAWINGS

You might also like