15
Undercut anchor KH AA
TECHNOLOGY
=9 =7
=3
ANCHOR
Execution
ETA ETA
DIBt
min
6,0 4,0 1,5 M6x8.5 14 555 020 820
6,0 4,0 3,0 M6x10 14 555 020 742
8,0 5,5 0,0 M6x8.5 14 * 555 020 856
FASTENERS
Surcharges
` If quantites lower than the packing unit are
ACCESSORIES
Comments
` * See appropriate approval table 13
` KEIL undercut anchors are monitored by
approved bodies
` Other dimensions on request
WALL ANCHOR
Usage
` Application only as per approval and KEIL
installation instructions 22
INFO
Photo: KEIL
16
Undercut anchor KH AA
TECHNOLOGY
► The undercut anchor consists of an anchor sleeve and its hex screw.
► Hole, anchor sleeve and screw length have to be matched to the hole depth required and to the panel bracket
chosen. Only the use of matching components results in quick, simple and safe installation.
► The anchor sleeve, which is compressed in the lower end, is placed in the hole with the specified panel
bracket.
► The screw is screwed in while exerting slight pressure on the panel bracket (to fix the anchor). The locking
ANCHOR
mechanism of the screw cuts into the panel bracket to secure it.
► The panel bracket forms a rigid unit with the KEIL facade anchor for this type of installation.
► The anchor sleeve is expanded to its original dimension by inserting the screw to a controlled depth,
so that the sleeve sits snugly against the undercut section of the hole in the facade panel. After installation,
the anchor sits stress-free in the undercut hole (i.e. the bracket can still be rotated with a certain amount of
effort).
FASTENERS
DRILLING TOOLS
DRILLING TECHNOLOGY
ACCESSORIES
WALL ANCHOR
INFO
Photos: Shackerley
17
Spacer
TECHNOLOGY
555 Spacer
SW A
7,5 6
SW B
ø
ANCHOR
Execution
ETA
ETA DIBt SWA SWB
` Washer with internal hex socket and hex head Ø15x6/7,5 * SW9 SW9 15 555 432 200
` Consisting of AlCuMgPb Ø20x6x7,5 * SW9 SW12 20 555 432 201
obnxf_A
Iuhe-fus
For use in
Product information 555
FASTENERS
unrg_tU
fichsebr
Application
` U sed for bracket installation
Accessories
` Diamond tipped facade drill bit with countersink
33
DRILLING TECHNOLOGY
Packaging
100 pcs
Comments
` * See appropriate approval table 13
Usage
ACCESSORIES
18 Photo: Ortmeyer
Undercut anchor KH BH
TECHNOLOGY
555 Undercut anchor KH BH
=9
= 14
=7
=3 =9
ANCHOR
Execution
ETA ETA
DIBt
min
9,5 7,0 4,0 M6x20 555 020 708
9,5 7,0 14,0 M6x30 555 020 736
11,0 8,5 2,5 M6x20 555 020 790
FASTENERS
` Anchor sleeve inc. A4 socket grub screw and 11,0 8,5 12,5 M6x30 555 020 822
nut with locking ratchet, stainless steel
13,0 10,0 11,0 M6x30 * 555 020 741
obnxf_A
Iuhe-fus
DRILLING TOOLS
` Manufactured stone ` Glass-fibre reinforced
18,0 15,0 1,5 M6x25 * 555 020 714
` Ceramics concrete
` Ceramic glass 18,0 15,0 6,5 M6x30 * 555 020 710
` HPL
18,0 15,0 11,5 M6x35 * 555 020 781
Accessories 18,0 15,0 16,5 M6x40 * 555 020 749
` Depth control guide for anchor hole 56 18,0 15,0 26,5 M6x50 * 555 020 764
` Wrench socket DIN 3126 E6.3 59 18,0 15,0 36,5 M6x60 * 555 020 788
` Special open jaw spanner AF9 58
DRILLING TECHNOLOGY
18,0 15,0 46,5 M6x70 * 555 020 803
` Socket for studs 61
Packaging
Product information 555
Undercut anchor KH BH
` The undercut anchor consists of an anchor ` The anchor sleeve is expanded to its origi-
sleeve a grub screw and a locking nut. nal dimension by inserting the screw
500 pcs ` Hole, anchor sleeve and screw length have to a controlled depth, so that the sleeve sits
to be matched to the hole depth required snugly against the undercut section of the
and to the panel bracket chosen. Only when hole in the facade panel.
Surcharges matching components are used is installati- After installation, the anchor sits stress-
free in the undercut hole (i.e. the bracket
ACCESSORIES
` If quantites lower than the packing unit are on fast, simple and safe.
can still be rotated with a certain amount of
ordered, the following surcharges apply: ` The anchor sleeve, which is compressed in effort).
` 499 - 100 pieces + 10% the lower end, is placed in the hole with the
specified panel bracket.
` 99 - 50 pieces + 25%
` 49 - 1 pieces + 40%
Comments
` * See appropriate approval table
` Stainless steel nut with locking ratchet, A2
WALL ANCHOR
Usage
` The screwed-in part must be flush with the
anchor sleeve at the front
` Application only as per approval and KEIL
installation instructions
INFO
M
=9 =7
=3 =9
ANCHOR
Execution
M
ETA
hs l4 DIBt
ETA
15 8 15 * 555 720 713 ◦
15 8 100 555 720 716 •
15 8 150 555 720 620 •
15 8 200 555 720 625 •
15 8 300 555 720 629 •
FASTENERS
Usage
` From I4 > 90 mm surface grooving
` Application only as per approval and KEIL
installation instructions 22
INFO
20
Undercut anchor KH AA 9/12
TECHNOLOGY
555 Undercut anchor KH AA 9/12
= 12
= 12 =9
=3
ANCHOR
Execution
min
` Anchor sleeve inc. hexagon bolt with locking
ratchet in stainless steel A4 25,0 20,0 0,0 M6x23 14 555 020 601
25,0 20,0 1,5 M6x24.5 14 555 020 602
obnxf_A
Iuhe-fus
unrg_tU
fichsebr
For use in
FASTENERS
` For the invisible, rear fixed attachment of faca- 25,0 20,0 3,0 M6x26 14 555 020 603
de panels made of (soft) sedimentary rocks
25,0 20,0 6,0 M6x29 14 555 020 604
Accessories
Product information 555
` Depth control guide for anchor hole 56
` Torque wrench 2-6 Nm 58 Undercut anchor KH AA
Packaging ` The undercut anchor consists of an anchor ` The panel bracket forms a rigid unit with
sleeve and its hex screw. the KEIL facade anchor for this type of
DRILLING TOOLS
` Hole, anchor sleeve and screw length have installation.
to be matched to the hole depth required ` The anchor sleeve is expanded to its
and to the panel bracket chosen. Only the original dimension by inserting the screw to
use of matching components results in a controlled depth, so that the sleeve sits
100 pieces
quick, simple and safe installation. snugly against the undercut section of the
` The anchor sleeve, which is compressed in hole in the facade panel. After installation,
Surcharges the anchor sits stress-free in the undercut
the lower end, is placed in the hole with the
` If quantites lower than the packing unit are specified panel bracket. hole (i.e. the bracket can still be rotated
ordered, the following surcharges apply: with a certain amount of effort).
` The screw is screwed in while exerting
DRILLING TECHNOLOGY
` 99 - 50 pieces + 25% slight pressure on the panel bracket (to
` 49 - 1 pieces + 40% fix the anchor). The locking mechanism of
the screw cuts into the panel bracket
to secure it.
Comments
` Other dimensions on request
Usage
` To be used in accordance with the KEIL
installation instructions
ACCESSORIES
WALL ANCHOR
INFO
21
General installation instructions
TECHNOLOGY
The KEIL System tools comprise the KEIL facade drill bit, the KEIL
drill head and the undercutting and drilling machine (e.g. KEIL porta-
ANCHOR
ble drill, KEIL bench drill or automatic drilling machine with KEIL drill
head).
The undercut hole is produced in one step (cylindrical drilling [1] and
undercutting [2]).
2
Correct installation of the undercut anchor is possible only if a
precisely undercut hole exists [3]. The hole geometry is regularly
FASTENERS
monitored with the KEIL gauge matching the insertion depth of the
anchor. The hole depth is set by means of this gauge, and all major
hole dimensions can be checked efficiently with it.
3
DRILLING TOOLS
DRILLING TECHNOLOGY
Assembly
The undercut anchor consists of an anchor sleeve and its hex screw. 4
The panel bracket forms a rigid unit with the KEIL facade anchor for
this type of installation.
22
General installation instructions
TECHNOLOGY
Safety Information
Correct functioning is only guaranteed if all components of the KEIL undercut facade system are used. Expansion
of the anchor sleeve controlled by insertion depth requires precise matching of the screw length to the anchor and
panel bracket by KEIL. Production of the undercut holes and installation should be carried out under workshop
conditions.
Workshop conditions in this sense can also be created on site.
ANCHOR
The dimensions of the undercut hole are to be monitored in accordance with the regulations in force. The appro-
vals, standards, guidelines and relevant regulations applicable to design and use must be observed.
Once the new Construction Product Regulations within the EU are ratified, instead of a ‘declaration of conformity’
a CE marking is required for a declaration of performance. ETA’s will in the future not make reference to, or provide
information with respect to a products application. For further information regarding the corresponding product
application it can be found (download area) at the following website www.keil.eu
FASTENERS
Notes on anchor installation
Anchor sleeves and locking screws for specified clamping thicknesses
If the appropriate screw is used for a defined clamping thickness, the insertion depth is always correct! Installation
is quick, easy and safe in this case. Similarly, the system ensures that the precise insertion depth is guaranteed
for KEIL plug-in anchors. The screwed-in part must be flush with the anchor sleeve at the front.
DRILLING TOOLS
CAUTION: Before final installation, it must be checked whether the screwed-in part is flush with the anchor sleeve
at the front and whether the correct installation tool is being used, by means of a test assembly.
DRILLING TECHNOLOGY
is used and the installation steps described below
are followed. The appropriate projection Ü is
automatically obtained.
Ü= S -D
Installation steps:
1. Place anchor sleeve into undercuted hole.
Ü 2. Place grub screw in screw driver.
3. Hold anchor sleeve with open-ended spanner and
screw in grub screw with screw driver to stop. -
ACCESSORIES
Release screw driver handle -
4. Check dimension Ü
5. Screw on panel bracket with nut.
Hole geometry
WALL ANCHOR
Legend
View of drilled hole geometry
D1 = hole diameter (dia. 7 mm)
D2 = undercut diameter (≥ dia. 9 mm)
xA xZ
D2 ≥ Ø 9
INFO
23
Undercut anchor KH AA 9/11 „autoundercut“
TECHNOLOGY
= 11 =9
=3
ANCHOR
Execution
min
` Anchor sleeve inc. hexagon bolt with locking
ratchet in stainless steel A4 12,0 7,0 0,0 M6x10 14 555 020 652
20,0 15,0 0,0 M6x18 14 555 020 651
obnxf_A
Iuhe-fus
unrg_tU
fichsebr
For use in
` For the invisible, rear fixed attachment of faca-
FASTENERS
Foto: Muhs
24