A3

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

PROJECT TITLE:

CEILING FINISH LEGEND: PROPOSED TWO STOREY


C-5 C-4
C-1 USE 10mm GYPSUM BOARD FOR RESIDENCE
CEILING.
C-3
0.90 LOCATION:
C-2 USE MOISTURE RESISTANT GYPSUM
BOARD FOR ALL T & B. PHASE 5, LOT NO 26 BLK 76, RAILEY ST.
C-2 DREAMCREST SUBDIVISION, BRGY
LONGOS, MALOLOS, BULACAN
17 DN
1 ARCHITECTURAL DETAILS
SCALE 1:50MTS
C-3 USE HARDIEFLEX BOARD FOR
CARPORT & SERVICE AREA CEILING
C-1
OWNER:
A 3

STAIRWELL
16
C-1
C-4 USE SPANDREL FOR MAIN ROOF EAVES
3.25M (270MM EACH STEP)

15
14 C-5 USE POLYCARBONATE ROOFING FLORENCIO VILLEGAS/ MARY JANE VILLEGAS
13 C-1 C-2
12
F F F F C-4
11
10
PLAN M + A DESIGN STUDIO
ARCHITECTURE | INTERIOR DESIGN | CONSTRUCTION
4.15

MOBILE NO: +639064039868 EMAIL: ma_designstudio@yahoo.com


9
C-2
8
7
6
2ND FLOOR C-1
17 FIN. FLR LINE C-1
5 16 C-3
BEAM ELEVATION 15
14
0.90

13
ARCHITECT
4 UP
3 2 1
12
C-3
11 AUDREY JANINE AVILLA

1.80
CONCRETE STEPS
10 PRC. REG. NO. 0041954
RISER @ 200MM EACH
9 17 STEPS GOING 2ND FLR C-4 IAPOA CERT. NO. -UAP #/UAP O.R. #/Date Issued

3.40
38619 215716 020918
8
PTR NO. 7551290 * QUEZON CITY * 01-19-2019 TIN NO. 491 112 897
7 C-5
0.90 .27 EACH STEP 6 C-3 R.A. 9266 ARTICLE IV SECTION 33:
5 Drawings and specifications duly signed, sealed or
4 REF

1.48
stamped, as instruments of service, are the intellectual
1.20 3
STORAGE property and documents of the architect, whether the
2
BENEATH object for which they are made is executed or not. It
1 STAIRS
GROUND FLOOR SECOND FLOOR shall be unlawful for any person to duplicate or to make
copies of said documents for use in the repetition of and
3 REFLECTED CEILING PLAN
SCALE
4 REFLECTED CEILING PLAN
SCALE for other projects or buildings, whether executed partly
A 3 1:175MTS
A 3 1:175MTS
or in whole, without the written consent of the architect
STAIRS ELEV or author of said documents.

SCHEDULE
DOOR SCHEDULE
LONG SPAN ROOFING
(PAINTED TERRACOTTA) 0.60 0.30
0.80 0.70 0.60

2" x 4" C - PURLINS


GAUGE 11 @ 0.60 M.O.C.

17 2'' X 2'' ANGLE CLEATS


2ND FLOOR FIN. FLOOR LINE

0.40
16 FOIL INSULATION
SINGLE BUBBLE DOUBLE FOIL
15 BEAM ELEVATION 0.20
F

0.60

1.40
14
13 G.I. GUTTER G.A. 21
(PAINTED CHOCO BROWN)
12 CONCRETE TILED

2.40

2.40

2.40

2.40

0.40

2.40
11 RISER @ 200MM EACH
1/2" THK x 5" HARDIE SENEPA
(PAINTED SAME COLOR AS SPANDREL CEILING
RB-1 REVISIONS
1.80

17 STEPS GOING 2ND FLR


10 1/2" THK x 6" HARDIE SENEPA
NO. DATE DESCRIPTION
9 SPANDREL EAVES
3.40

BEIGE COLOR

1.00

1.00
8
7 TO SUPPORT TRUSS
METAL RAILING

WINDOW
6
5 ROOFING: GUTTER & PURLINS DETAILS
4
D D D W W
1.20

3
2
01 02 03 01 02
1 D - 01 D - 02 D - 03 W-01 W-02
DESIGNATION DESIGNATION DESIGNATION DESIGNATION DESIGNATION

GROUND FLOOR FIN. FLR. LINE


SCHEDULE OF DESCRIPTION

NO. OF SETS
WOOD PANEL DOOR
SWING TYPE DOOR

2
DESCRIPTION

NO. OF SETS
WOOD PANEL DOOR
SWING TYPE DOOR

4
DESCRIPTION

NO. OF SETS
WOOD PANEL DOOR
SWING TYPE DOOR

3
DESCRIPTION
PVC CASEMENT GLASS WINDOW
W/ 8MM THK
TEMPERED GLASS
DESCRIPTION
PVC FIXED GLASS WINDOW
W/ 8MM THK
TEMPERED GLASS

DOORS
NO. OF SETS 1 NO. OF SETS 1
SIZE 0.80 X 2.40 MTS SIZE 0.70 X 2.40 MTS SIZE 0.60 X 2.40 MTS
SIZE 0.60 MTS X 1.40 MTS SIZE 0.30 MTS X 1.40 MTS
LOCATION LIVING & BALCONY LOCATION ALL BDRMS & SERVICE AREA LOCATION ALL T&B
LOCATION LIVING AREA LOCATION LIVING AREA
NOTE:
STAIRS ELEV FINISH POWDER COATED FINISH POWDER COATED

2 & WINDOWS ALL MEASUREMENTS MUST BE VERIFIED AT THE SITE


BEFORE CONSTRUCTION. CONTRACTORS SHALL NOTIFY
SCALE
A 3 1:50MTS THE ARCHITECT/DESIGNER OF ANY DISCREPANCY BEFORE
COMMENCEMENT OF WORK, AGC DESIGN CONCEPTS SHALL
NOT BE HELD RESPONSIBLE FOR ANY ERRORS SHOULD THE
CONTRACTOR FAIL TO OBSERVE THIS PROCEDURE. THE
CONTRACTOR SHALL BE RESPONSIBLE FOR ANY ERRORS
1.80 1.00 1.60 1.20 2.40 2.20 0.60 0.40
RESULTING FROM FAILURE TO DO SO.
0.30
0.45 0.45 0.45 0.45 0.50 0.50 0.60 0.40 0.60 0.60 0.60 0.60 0.60 0.60 0.60 1.00 0.60 0.60
SHEET CONTENTS:

STAIR PLAN & DETAILS


0.41

0.40

0.40

0.40
REFLECTED CEILING PLANS

0.60

0.60
ARCHITECTURAL DETAILS
1.20

1.20
0.60

0.60

0.60

0.60
1.40

F F F F SCHEDULE OF DOORS
SCHEDULE OF WINDOWS
2.40

2.40

2.40

2.40

0.40

2.40

0.40

2.40

2.40

2.40

2.40
0.60

1.80

1.80
1.40

1.20

1.20

0.60
1.00

1.00

1.00

0.20
W W W W W W W W W NOTE:
03 04 05 06 07 08 09 10 11 DO NOT SCALE DRAWINGS. FIGURED DIMENSIONS ARE TO BE
FOLLOWED. READ THIS DRAWING IN CONNECTION WITH THE
DESIGNATION W-03 DESIGNATION W-04 DESIGNATION W-05 DESIGNATION W-06 DESIGNATION W-07 DESIGNATION W-08 DESIGNATION W-09 DESIGNATION W-10 DESIGNATION W-11 GENERAL ARCHITECTURAL WORKING DRAWINGS,
PVC SLIDING GLASS WINDOW PVC SLIDING GLASS WINDOW PVC CASEMENT GLASS
PVC AWNING & CASEMENT
GLASS WINDOW PVC CASEMENT GLASS WINDOW PVC FIXED GLASS WINDOW PVC AWNING GLASS WINDOW PVC AWNING GLASS WINDOW PVC AWNING GLASS WINDOW STRUCTURAL, SANITARY, ELECTRICAL & MECHANICAL PLANS &
DESCRIPTION W/ 8MM THK DESCRIPTION W/ 8MM THK DESCRIPTION WINDOW W/ 8MM THK DESCRIPTION DESCRIPTION W/ 8MM THK DESCRIPTION W/ 8MM THK DESCRIPTION W/ 8MM THK DESCRIPTION W/ 8MM THK DESCRIPTION W/ 8MM THK
TEMPERED GLASS TEMPERED GLASS TEMPERED GLASS
W/ 8MM THK
TEMPERED GLASS TEMPERED GLASS TEMPERED GLASS TEMPERED GLASS TEMPERED GLASS
OTHER RELATED DRAWINGS. ANY DISCREPANCY FOUND
TEMPERED GLASS
NO. OF SETS 1 NO. OF SETS 1 NO. OF SETS 1 NO. OF SETS 1 NO. OF SETS 3 NO. OF SETS 1 NO. OF SETS 1 NO. OF SETS 1 NO. OF SETS 1 THEREIN SHALL BE NOTIFIED TO THE ARCHITECT OF RECORD
SIZE 0.60 MTS X 1.80 MTS SIZE 1.20 MTS X 1.20 MTS SIZE 0.30 MTS X 1.20 MTS SIZE 1.60 MTS X 1.20 MTS SIZE 1.20 MTS X 1.20 MTS SIZE 2.40 MTS X 1.40 MTS SIZE 2.20 MTS X 2.20 MTS SIZE 0.60 MTS X 0.60 MTS SIZE 0.40 MTS X 0.60 MTS IMMEDIATELY.
LOCATION STAIRWELL LOCATION KITCHEN LOCATION KITCHEN LOCATION BEDROOM 2 LOCATION MASTERS, BDRM 1 & FAMILY AREA LOCATION 2ND FLOOR STARIWELL LOCATION MASTERS BEDROOM LOCATION MASTERS BEDROOM LOCATION POWDER ROOM
FINISH POWDER COATED FINISH POWDER COATED FINISH POWDER COATED FINISH POWDER COATED FINISH POWDER COATED FINISH POWDER COATED FINISH POWDER COATED FINISH POWDER COATED FINISH POWDER COATED DRAWN BY:
DATE
CHECKED:
DATE
PROJECT NO.