STP Calculation
STP Calculation
STP Calculation
Influent BOD 367 BOD load/Hydraulic Load If Influent BOD is too high, it is advisable to dilute before
treatment
Design of Septic Tank calculate as below or read from T 2,3,4
no. of WC 40.00
rate of discharge 9.00 l
Peak flow rate 252.00 l /min assume 70% of the fixtures discharge simutanously
Primary Sedimentation Tank Design
Rectangular Basin
Code Reference Ten States Standard
Step 1 List Ten State Standard
BOD removal % 33% 121 BOD
2
surface settling rate,v 700 gal/d.ft 600~1200
3 2
28.5 m /m d 24.5~49
depth 3 m >3
3
weir loading 250 m /d.m 250~373
10000 gal/d.ft 20000~30000
inlet velocity 0.3 m/s
free board 0.3 m
Step 13 Check organic loading rate and mass of ultimate BODu utlized
𝑄 𝑆0 3
𝐿𝑜𝑎𝑑𝑖𝑛𝑔 = 0.79 kg BOD 5/m d
𝑉
BOD5 = 0.67 BODu , BOD5 = Q(S0-S)
𝐵𝑂𝐷𝑢 = 𝑄(𝑆0 − 𝑆)/0.67 21 kg/d
3 2
Overflow rate 3.37 m /m d
Q r, S, Xr
Return Activated Q ea, Xr
< design 2400 mg/l
Slug (RAS) sludge wasting
form return slug
line
Clorination Tank Design
Detention time: 30 min
Volume Flowrate 60.00 m3/day
Clorination tank vol 1.25 m3
Length 1m
Depth 2m
Width 0.625 m