C USTOMER SERVICE SHORT INFORMATION N O : 04/010

...................................

.....
M OTOR TRANSMITTER E RROR

DMG Service UFB GmbH Seebach


Prepared: J. Sinsel Zentraler Service
Date: 09/2004 Neue Strasse 61
D-99846 Seebach

09/2004 Customer service short information No: 04/010


ERROR CORRECTION: SPORADIC EMERGENCY STOPS

Error correction: Sporadic emergency stops


At all the machines with
speed monitoring module PNOZms1p
it can come to sporadic emergency stops after the error message
'temperature monitoring motor and/or motor transmitter error'
(spindle, X-, Y-, Z-axis).

Error cause:
At the adapter plug speed monitoring (between the plug A-LINE motor transmitter and
the plug motor transmitter at the N/C control
at SIEMENS: X411,
at iTNC: X15,X16...)
are the fixing bolts too long (tolerance fluctuations). Thus the adapter plug cannot be
fixed firmly. These bad contact problems lead to above errors.
Bild 1: adapter plug SIEMENS: X411 adapter plug iTNC

Solution:
Attach an auxiliary or an exchange plain washer between screw head and current lam-
ina. (lamina DMG Ident NR. 27069927).

2 Customer service short information No: 04/010 09/2004