Download as pdf or txt
Download as pdf or txt
You are on page 1of 84

DC

Motor
Increase 7%
Length

Cross Flow Fan

2018 Residential General Catalogue


EU Sep. 2018

27°
Version 1.0

Detachable Bottom Cover 175mm

EU
ADDRESS
No.1 Haier Road, Hi-tech Zone, Qingdao 266101 P.R.China
CONTACTS
Tel: +86-532-8893-7937
Website: www.haierac.com
2018 RESIDENTIAL
AIR CONDITIONING
Our Vision :
To be a recognized leader in global HVAC industry by innovation in technology,
product and business model.

Our Mission :
Through all of our efforts in innovation in control, air quality, heating & cooling
performance & service to make comfort easier.

Our Promise :
Comfort Made Easier.
CONTENT
01.
Haier Group Product Line
01/ Haier Brand Story
02/ Haier Global Position 43/ Seasonal Green R32
02/ Haier Global Network 43/ -Dawn Series
45/ -Flexis Series

02.
47/ -Flare Series
49/ -Tundra Green Series

Haier Air Conditioning 51/ Seasonal Nordic


03/ Haier AC Milestones 51/ -Crystal Series (for Nordic)
05/ AC R&D Center
07/ Global Manufacturing Capacity
53/ Seasonal Super Match
08/ Haier Air Conditioning in Europe
53/ -Nebula Series
55/ -Brezza Series

03.
65/ -Console Series

57/ Seas
asson
nal
al Bas
asic
ic
Air Conditioning
Key Functions 57/ -Tund
dr Seri
dra ries
es

13/ Whispering Air


17/ Smart Control 67// Ca
67 Cabi
biine
et
25/ Easy Installation
67// -C
67 Cab
bin
nett Serrie
ies
29/ Differentiated Function
-Energy Saving
-Comfort Care
-Health Care
71
1/ Po
Port
rttab
able
le Airr Con
ondi
ditti
di tion
onin
ing
-User Friendly 71
71/ -Po
Port
rtab
rta le Air Condi
d ti
tio
onin
ng
Our Vision :
To be a recognized leader in global HVAC industry by innovation in technology,
product and business model.

Our Mission :
Through all of our efforts in innovation in control, air quality, heating & cooling
performance & service to make comfort easier.

Our Promise :
Comfort Made Easier.
CONTENT
01.
Haier Group Product Line
01/ Haier Brand Story
02/ Haier Global Position 43/ Seasonal Green R32
02/ Haier Global Network 43/ -Dawn Series
45/ -Flexis Series

02.
47/ -Flair Series
49/ -Tundra Green Series

Haier Air Conditioning 51/ Seasonal Nordic


03/ Haier AC Milestones 51/ -Crystal Series (for Nordic)
05/ AC R&D Center
07/ Global Manufacturing Capacity
53/ Seasonal Super Match
08/ Haier Air Conditioning in Europe
53/ -Nebula Series
55/ -Brezza Series

03.
65/ -Console Series

57/ Seas
asson
nal
al Bas
asic
ic
Air Conditioning
Key Functions 57/ -Tund
dr Seri
dra ries
es

13/ Whispering Air


17/ Smart Control 67// Ca
67 Cabi
biine
et
25/ Easy Installation
67// -C
67 Cab
bin
nett Serrie
ies
29/ Differentiated Function
-Energy Saving
-Comfort Care
-Health Care
71
1/ Po
Port
rttab
able
le Airr Con
ondi
ditti
di tion
onin
ing
-User Friendly 71
71/ -Po
Port
rtab
rta le Air Condi
d ti
tio
onin
ng
Global Position
Established in 1984, Haier is the world's No. 1 major appliance brand. In the Internet age, Haier aims to become a Networked Enterprise
and its global revenue reaching 30.7 billion USD in 2016.

30.7
billion

USD
Networking
Strategy
25.8
billion

Global Brand
16.7 Strategy
billion

Internationalization
Strategy
2.69
billion

Diversification
133 Strategy
million
Brand Building
Strategy
557K

1984 1991 1998 2005 2012 2016 year

Global Network
Haier has built up its infrastructures globally to meet the customers' quick evolving demands, including R&D centers, production
facilities, trading companies and sales networks etc.
Haier's five R&D centers around the world have forged strategic partnerships with first-class suppliers, research institutions, and
prestigious universities to create an innovative ecosystem composed of internal and external scientists and engineers connected by
virtual and physical networks.

America-GEA Industry America-GEA R&D Europe-R&D Center in Asia-R&D Center in China Asia-GEA R&D Center in China
Park in USA Center in USA Germany x42 x54 x2

x12

x4 x1 Asia-AQUA R&D Center


x1 x26 x3 x2 in Japan
x1

Brand Story
x4
East Asia
Europe
America
South Asia China
x8 x3 x1
Dubai
Asia-GEA R&D Center
x1 Saudi Arabia in Korea

x5 x14

The Internet era is a diverse and unconvention


nal time, where “one size fits all” productss and solutions simply are not enough. Middle East & Southeast Asia
x4
America-GEA R&D
Customers want to be treated as individuals and resppec
ecte
ted for who they are. Center in Mexico Africa
x1

Everyone wants their unique lifestyle acknowledged. That is why Haier listens closely to you in order to gain a genuine understanding of x2 x8
x2
x1

what is going on in your life and what is on your mind. So each of you can get the smart home experience you deserve: be it simple, Oceania
Worldwide Network Overseas Global x2 x2
x2 x1

sophisticated, organized or enjoyable. Trading Company


x1

As a worldwide industry leader, Haier innovates beyond products and solutions and turns the organization into a wholly connected R&D Center

platform. In doing so, internal and external resources are connected quickly and easily. We believe only by doing so, we can best meet Manufactory 54 108
Africa-Manufactory in Nigeria Africa-Manufactory in Tunis Asia-GEA R&D Center Oceania-FPA R&D Center
our consumers’ expectations in this rapidly evolving world. Industry Park 12 24 in India in New Zealand

Sales Network 143330


Be part of the Haier Network. Create new possibilities.

01 02
Global Position
Established in 1984, Haier is the world's No. 1 major appliance brand. In the Internet age, Haier aims to become a Networked Enterprise
and its global revenue reaching 30.7 billion USD in 2016.

30.7
billion

USD
Networking
Strategy
25.8
billion

Global Brand
16.7 Strategy
billion

Internationalization
Strategy
2.69
billion

Diversification
133 Strategy
million
Brand Building
Strategy
557K

1984 1991 1998 2005 2012 2016 year

Global Network
Haier has built up its infrastructures globally to meet the customers' quick evolving demands, including R&D centers, production
facilities, trading companies and sales networks etc.
Haier's five R&D centers around the world have forged strategic partnerships with first-class suppliers, research institutions, and
prestigious universities to create an innovative ecosystem composed of internal and external scientists and engineers connected by
virtual and physical networks.

America-GEA Industry America-GEA R&D Europe-R&D Center in Asia-R&D Center in China Asia-GEA R&D Center in China
Park in USA Center in USA Germany x42 x54 x2

x12

x4 x1 Asia-AQUA R&D Center


x1 x26 x3 x2 in Japan
x1

Brand Story
x4
East Asia
Europe
America
South Asia China
x8 x3 x1
Dubai
Asia-GEA R&D Center
x1 Saudi Arabia in Korea

x5 x14

The Internet era is a diverse and unconvention


nal time, where “one size fits all” productss and solutions simply are not enough. Middle East & Southeast Asia
x4
America-GEA R&D
Customers want to be treated as individuals and resppec
ecte
ted for who they are. Center in Mexico Africa
x1

Everyone wants their unique lifestyle acknowledged. That is why Haier listens closely to you in order to gain a genuine understanding of x2 x8
x2
x1

what is going on in your life and what is on your mind. So each of you can get the smart home experience you deserve: be it simple, Oceania
Worldwide Network Overseas Global x2 x2
x2 x1

sophisticated, organized or enjoyable. Trading Company


x1

As a worldwide industry leader, Haier innovates beyond products and solutions and turns the organization into a wholly connected R&D Center

platform. In doing so, internal and external resources are connected quickly and easily. We believe only by doing so, we can best meet Manufactory 54 108
Africa-Manufactory in Nigeria Africa-Manufactory in Tunis Asia-GEA R&D Center Oceania-FPA R&D Center
our consumers’ expectations in this rapidly evolving world. Industry Park 12 24 in India in New Zealand

Sales Network 143330


Be part of the Haier Network. Create new possibilities.

01 02
AC Milestones

2017
2016 Haierr
Haie
launching
2015 Haier easyy
launch hin
ingg inst
stal
alla
lati
t on
o
2014 Haier build
Haie fullll range of
fu prod
products
u the
up
2013 Haier
H worl
wo rld'
d's
air
coondndititio
ioners
Flexis
Series.
estaabl
blis
ish
h AC mostt with the
Haierr
Haie R&D
R& D cent nte
er Haier India
Haie
adva
ad vancnced lo
owe
west st noise
i trod
in duc
uceses to enh
nhan ance air
2011
intelllig
igen
entt in the
Empe
Em peror the
the R&D D condn itione
nerr
factoryy
fa indu
in dust stry
ry..
fact
fa ctor
ory put
2001
series and ab
bilit
ityy with
Aero
Ae ro ser
eries m re foccus
mo in
n use.
Haierr
Haie
1999
floor
flo or on useser's
in
ntr
t odduc
uces
es
Haier builds
Haie standing e perience
ex ce
full range
1998 Haier begins
up inddus
park in
ustr
tryy of Sup
match
uper
er
mode
mo dels
ls
which lead
1994 Haie er
expo
p rt of air
conditiones
Pakist
Pa s an
catches
a and s lution
so
the
th e
innovation in
1993
covering
intrrod
oduc
uces
es to the United No.1 market design and
Haier on-off and
the first airr su
ai supp
pplyly
1985
States and shar
share in inve
in vert
rter
er
r ceives
re es ISO digital DC reac
re ache
hess #11 s stem
sy
Ha er
Haie 2005
05 models as
9001
90 0
1984
inve
in vert
rter
er air brand status
intr
in trod
oducuces
es cert
ce rtifi
ificaati
t on well as
Qingda
Qing dao co
cond
onditioone
nerr for Room
C ina's firrst
Ch mono and
Qingkong Haaie
H
Haieer in
n Chinana and Portable
inve
in vert
rter
er air multi
Haie
er air exxpo
expo ort
rts it
is Air system
condndit
itioner
grou
up was conditio oner firstt air Conditioners
founded in fact
fa ctoryy co
ond
ndititiione
n rs in 2005
Q ngdao,
Qi o, essta
esta
tabl
blis
bl ishe
is hed
hed to Europe
China

Super match

03 04
AC Milestones

2017
2016 Haierr
Haie
launching
2015 Haier easyy
launch hin
ingg inst
stal
alla
lati
t on
o
2014 Haier build
Haie fullll range of
fu prod
products
u the
up
2013 Haier
H worl
wo rld'
d's
air
coondndititio
ioners
Flexis
Series.
estaabl
blis
ish
h AC mostt with the
Haierr
Haie R&D
R& D cent nte
er Haier India
Haie
adva
ad vancnced lo
owe
west st noise
i trod
in duc
uceses to enh
nhan ance air
2011
intelllig
igen
entt in the
Empe
Em peror the
the R&D D condn itione
nerr
factoryy
fa indu
in dust stry
ry..
fact
fa ctor
ory put
2001
series and ab
bilit
ityy with
Aero
Ae ro ser
eries m re foccus
mo in
n use.
Haierr
Haie
1999
floor
flo or on useser's
in
ntr
t odduc
uces
es
Haier builds
Haie standing e perience
ex ce
full range
1998 Haier begins
up inddus
park in
ustr
tryy of Sup
match
uper
er
mode
mo dels
ls
which lead
1994 Haie er
expo
p rt of air
conditiones
Pakist
Pa s an
catches
a and s lution
so
the
th e
innovation in
1993
covering
intrrod
oduc
uces
es to the United No.1 market design and
Haier on-off and
the first airr su
ai supp
pplyly
1985
States and shar
share in inve
in vert
rter
er
r ceives
re es ISO digital DC reac
re ache
hess #11 s stem
sy
Ha er
Haie 2005
05 models as
9001
90 0
1984
inve
in vert
rter
er air brand status
intr
in trod
oducuces
es cert
ce rtifi
ificaati
t on well as
Qingda
Qing dao co
cond
onditioone
nerr for Room
C ina's firrst
Ch mono and
Qingkong Haaie
H
Haieer in
n Chinana and Portable
inve
in vert
rter
er air multi
Haie
er air exxpo
expo ort
rts it
is Air system
condndit
itioner
grou
up was conditio oner firstt air Conditioners
founded in fact
fa ctoryy co
ond
ndititiione
n rs in 2005
Q ngdao,
Qi o, essta
esta
tabl
blis
bl ishe
is hed
hed to Europe
China

Super match

03 04
AC R&D Center Comfort Evaluation Labs

Haier Air Conditiooni


ning R&D Center, loc
ocated in Qingdao, Chihina, completed in Dec ecember 2013, covers 20,00 00 square meters. It has
more than 120 0 laboratories, includ
din
i g testing laboratories
es, key part research laabo
boratories and all-weather usser experience simulation
laboratories
es.. Th
The R&D center also has the world tallest “d
“dro
rop tower” for testing g lon
o g refrigerant piping tests
ts(3
(350
5 feet tall).
User Comfort Simulated
Evaluation Rainfall Test
In April 2014, Haier established joint laboratories with Hig
ghl ng &cooling technology and wit
hlyy for research in heatin ith
h Mitsubishi Electric
forr innovative technology fo
fo f r us
user
er experrience. Research
h by the user experience cen entet r covers the fields of user comfort evaluation,
aerodynamics, acoustics, EMC MC(Electro o-Magnetic Compat atib
ibility) and mechanics etcc. ThT e labs can carry out more e th
than
an 600 international
tests as per ISO, IEC, EN, CIS
I PR and ANSI etc. to meet thehe requirements of Europe, e, Asi
s a, America, Australia, Middle East and other 100
countries and regions.
Simulated Simulated
Snow Test Sunshine Test

Air Enthalpy Test Labs

Performance Test Safe Test

Humidity
Reliability Test Condition Handling
Haier & Mitsubishi joint laboratoryy

Acoustic Labs EMC Test Double 85 Test Drop Test

Haierr & HIC


H HLY joint laboratory

05 06
AC R&D Center Comfort Evaluation Labs

Haier Air Conditiooni


ning R&D Center, loc
ocated in Qingdao, Chihina, completed in Dec ecember 2013, covers 20,00 00 square meters. It has
more than 120 0 laboratories, includ
din
i g testing laboratories
es, key part research laabo
boratories and all-weather usser experience simulation
laboratories
es.. Th
The R&D center also has the world tallest “d
“dro
rop tower” for testing g lon
o g refrigerant piping tests
ts(3
(350
5 feet tall).
User Comfort Simulated
Evaluation Rainfall Test
In April 2014, Haier established joint laboratories with Hig
ghl ng &cooling technology and wit
hlyy for research in heatin ith
h Mitsubishi Electric
forr innovative technology fo
fo f r us
user
er experrience. Research
h by the user experience cen entet r covers the fields of user comfort evaluation,
aerodynamics, acoustics, EMC MC(Electro o-Magnetic Compat atib
ibility) and mechanics etcc. ThT e labs can carry out more e th
than
an 600 international
tests as per ISO, IEC, EN, CIS
I PR and ANSI etc. to meet thehe requirements of Europe, e, Asi
s a, America, Australia, Middle East and other 100
countries and regions.
Simulated Simulated
Snow Test Sunshine Test

Air Enthalpy Test Labs

Performance Test Safe Test

Humidity
Reliability Test Condition Handling
Haier & Mitsubishi joint laboratoryy

Acoustic Labs EMC Test Double 85 Test Drop Test

Haierr & HIC


H HLY joint laboratory

05 06
Global Manufacturing Capacity Air Conditioning in Europe
Domestically, Haier AC is running 8 factories, 1 of which is MHAQ, a JV between Haier and Mitsubishi Heavy. In overseas markets, Value We Provide
Haier is running 8 manufacturing plants.
Haier AC commits to be a recognized leaders in global HVAC industry by innovation in technology, product and business model.
With all these factories, Haier AC has a product capacity amounts to 20.1 million sets per year. In Europe, Haier AC provides a best experience and solution to end users , Distributors/Installers and Environment.

End Users
Whispering Air
Quiet to 15dB(A).
Chongqing Wuhan Zhengzhou Hefei Dalian MHAQ Huangdao Jiaozhou
Distributors / Installers

51% less stock and logistic,


Saving 30% installation time,
Saving 60% service time.

Environment
High efficiency.
R32 Refrigerant.
Friendly
68% less GWP, ODP=0.

European Presence
Haier air conditioning focuses on building local organizations to offer more efficient and professional solution and service to our
customers and users in France, Italy, Spain, Germany, UK, Belgium, Poland and Russia, while in other Europe countries listed below we
mainly cooperate with the local professional HVAC partners to ensure our presence and service.

Haier Local Haier Agent


Offices

P nd
Pola
Belg
gium
m

Algeria Nigeria Tunis Pakistan India Bangladesh Thailand Vietnam


07 08
Global Manufacturing Capacity Air Conditioning in Europe
Domestically, Haier AC is running 8 factories, 1 of which is MHAQ, a JV between Haier and Mitsubishi Heavy. In overseas markets, Value We Provide
Haier is running 8 manufacturing plants.
Haier AC commits to be a recognized leaders in global HVAC industry by innovation in technology, product and business model.
With all these factories, Haier AC has a product capacity amounts to 20.1 million sets per year. In Europe, Haier AC provides a best experience and solution to end users , Distributors/Installers and Environment.

End Users
Whispering Air
Quiet to 15dB(A).
Chongqing Wuhan Zhengzhou Hefei Dalian MHAQ Huangdao Jiaozhou
Distributors / Installers

51% less stock and logistic,


Saving 30% installation time,
Saving 60% service time.

Environment
High efficiency.
R32 Refrigerant.
Friendly
68% less GWP, ODP=0.

European Presence
Haier air conditioning focuses on building local organizations to offer more efficient and professional solution and service to our
customers and users in France, Italy, Spain, Germany, UK, Belgium, Poland and Russia, while in other Europe countries listed below we
mainly cooperate with the local professional HVAC partners to ensure our presence and service.

Haier Local Haier Agent


Offices

P nd
Pola
Belg
gium
m

Algeria Nigeria Tunis Pakistan India Bangladesh Thailand Vietnam


07 08
AC in Europe
The ERP Directive (Eco-design)
Haier air conditioning commits to offer upgrade solutions meeting the requirements of EU environment protection regulations!
Haier AC has developed full range solutions covering all levels of energy class according to new ERP directive.
Preventing dangerous climate change is a key priority for the European Union, EU is working hard to improve energy efficiency and cut
its greenhouse gas emissions.

• Haier minimum energy class is leveled up to A++/A+ (9k) which


is much higher than the compulsory entry level (B/A) required
New F-gas Regulation from 2015 AS25S2SD1FA/1U25S2PJ1FA by the regulation.
SEER SCOP

The original F-gas Regulation, adopted in 2006, is being replaced by anew Regulation (EU) No 517/2014 adopted in 2014 which applies A+++ A+++ A+++ A+++ A+++
from 1 January 2015. This strengthens the existing measures and introduces a number of far-reaching changes by: A++ A++
A+ A+
A A
B B
C C
D D • In 2018, Haier developing full range of R32 products reaching
• Limiting the total amount of the most important F-gases that can be
kW 2,6
SEER 8,5
kW 1,4
SCOP 6,2
2,6
5,1
X
X
SCOP A+++/A++/A+ and guarantee the reliable operation in
kWh/annum 107 kWh/annum 320 716 X
sold in the EU from 2015 onwards and phasing them down in steps cold ambient temperature place like Nordic area.
to one-fifth of 2014 sales in 2030. 54 dB

61 dB

ENERGIA · ЕНЕРГИЯ · ΕΝΕΡΓΕΙΑ · ENERGIJA · ENERGY · ENERGIE ENERGINER


For detailed information about ERP, please visit Haier B2B website:
• Banning the use of F-gases in many new types of equipment where 626/2011
http://www.haierac.com
less harmful alternatives are widely available, such as fridges in homes
or supermarkets, air conditioning and foams and aerosols;

European
• Preventing emissions of F-gases from existing equipment by
Commission requiring checks, proper servicing and recovery of the gases at the
end of the equipment's life.

Haier AC Listed in Eurovent from 2004


Haier has been committed to develop reliable AC systems with high performance, our residential ranges and light
commercial ranges continue to be recommended in EUROVENT certification list as we have done in the last over 10 years, this ensures
Haier products & solutions are certified as one of the best choices by the installers and users.
120%
100%
Baseline Total quantity of HFC allowed
to be placed on the EU market
100% 93%
Of Baseline MT CO2 eq
2015 100% 182.9
80% 2016-2017 93% 170.1 Eurovent Certita Certification S.A.S. - 48/50, rue de la victoire - 75009 PARIS FRANCE
R.C.S. PARIS 513 133 637 - NAF 7120B

Accreditation #5-0517 Products and Services Certification


according to NF EN ISO/CEI 17065:2012 - Scope available on
www.cofrac.fr.
COFRAC is signatory of EA MLA, list of EA members is available in
http://www.european-accreditation.org/ea-members

63% 2018-2020 63% 115.2 Certification Diploma N° : 17.03.211


Eurovent Certita Certification certifies that

European Heat Pumps


60% from

Haier Overseas Electric Appliances Corp. Ltd


45% Located at
South room #401, Brand Center Building - Haier High-Tech Industrial Park, Lao Shan District,
266101 Qingdao (Shandong Province), China
Range
Super Match - Nebula

40% Trade name


31% HAIER

have been assessed according the requirements of following standard


OM-17-2016
24%
21% The list of certified products is displayed at :
http://www.eurovent-certification.com

20%

Haier Overseas Electric Appliances Corp. Ltd


is authorised to use the EUROVENT CERTIFIED PERFORMANCE mark
in accordance with the rules specified in the Operational Manual
OM-17-2016

0%
2015

2016

2017

2018

2019

2020

2021

2022

2023

2024

2025

2026

2027

2028

2029

2030

2031

2032

2033

2034

2035

Erick MELQUIOND Approval date : 2017/03/07


President Re-checked on : 2017/03/07
Valid until : 2017/12/31

Claris version: Prod 6.3b (03/03/2017)

Quantity of HFC Allowed to be Placed on the Market (% of the Baseline)

09 10
AC in Europe
The ERP Directive (Eco-design)
Haier air conditioning commits to offer upgrade solutions meeting the requirements of EU environment protection regulations!
Haier AC has developed full range solutions covering all levels of energy class according to new ERP directive.
Preventing dangerous climate change is a key priority for the European Union, EU is working hard to improve energy efficiency and cut
its greenhouse gas emissions.

• Haier minimum energy class is leveled up to A++/A+ (9k) which


is much higher than the compulsory entry level (B/A) required
New F-gas Regulation from 2015 AS25S2SD1FA/1U25S2PJ1FA by the regulation.
SEER SCOP

The original F-gas Regulation, adopted in 2006, is being replaced by anew Regulation (EU) No 517/2014 adopted in 2014 which applies A+++ A+++ A+++ A+++ A+++
from 1 January 2015. This strengthens the existing measures and introduces a number of far-reaching changes by: A++ A++
A+ A+
A A
B B
C C
D D • In 2018, Haier developing full range of R32 products reaching
• Limiting the total amount of the most important F-gases that can be
kW 2,6
SEER 8,5
kW 1,4
SCOP 6,2
2,6
5,1
X
X
SCOP A+++/A++/A+ and guarantee the reliable operation in
kWh/annum 107 kWh/annum 320 716 X
sold in the EU from 2015 onwards and phasing them down in steps cold ambient temperature place like Nordic area.
to one-fifth of 2014 sales in 2030. 54 dB

61 dB

ENERGIA · ЕНЕРГИЯ · ΕΝΕΡΓΕΙΑ · ENERGIJA · ENERGY · ENERGIE ENERGINER


For detailed information about ERP, please visit Haier B2B website:
• Banning the use of F-gases in many new types of equipment where 626/2011
http://www.haierac.com
less harmful alternatives are widely available, such as fridges in homes
or supermarkets, air conditioning and foams and aerosols;

European
• Preventing emissions of F-gases from existing equipment by
Commission requiring checks, proper servicing and recovery of the gases at the
end of the equipment's life.

Haier AC Listed in Eurovent from 2004


Haier has been committed to develop reliable AC systems with high performance, our residential ranges and light
commercial ranges continue to be recommended in EUROVENT certification list as we have done in the last over 10 years, this ensures
Haier products & solutions are certified as one of the best choices by the installers and users.
120%
100%
Baseline Total quantity of HFC allowed
to be placed on the EU market
100% 93%
Of Baseline MT CO2 eq
2015 100% 182.9
80% 2016-2017 93% 170.1 Eurovent Certita Certification S.A.S. - 48/50, rue de la victoire - 75009 PARIS FRANCE
R.C.S. PARIS 513 133 637 - NAF 7120B

Accreditation #5-0517 Products and Services Certification


according to NF EN ISO/CEI 17065:2012 - Scope available on
www.cofrac.fr.
COFRAC is signatory of EA MLA, list of EA members is available in
http://www.european-accreditation.org/ea-members

63% 2018-2020 63% 115.2 Certification Diploma N° : 17.03.211


Eurovent Certita Certification certifies that

European Heat Pumps


60% from

Haier Overseas Electric Appliances Corp. Ltd


45% Located at
South room #401, Brand Center Building - Haier High-Tech Industrial Park, Lao Shan District,
266101 Qingdao (Shandong Province), China
Range
Super Match - Nebula

40% Trade name


31% HAIER

have been assessed according the requirements of following standard


OM-17-2016
24%
21% The list of certified products is displayed at :
http://www.eurovent-certification.com

20%

Haier Overseas Electric Appliances Corp. Ltd


is authorised to use the EUROVENT CERTIFIED PERFORMANCE mark
in accordance with the rules specified in the Operational Manual
OM-17-2016

0%
2015

2016

2017

2018

2019

2020

2021

2022

2023

2024

2025

2026

2027

2028

2029

2030

2031

2032

2033

2034

2035

Erick MELQUIOND Approval date : 2017/03/07


President Re-checked on : 2017/03/07
Valid until : 2017/12/31

Claris version: Prod 6.3b (03/03/2017)

Quantity of HFC Allowed to be Placed on the Market (% of the Baseline)

09 10
In ord
rder
er to me
meetet the F-GAS AS reg
e ulation and d upgradded requirementts of energy effi fficiiency in
n EU
EU, Ha
H ier
has madede cono si
s derable investment in R&D to provide full range R32 solution which has much less
CO₂₂ em
CO emisissi
sion
on,, Be
Besi
side
de,, Hai
aier
er air con
ondi
d ti
tion
oner
e s realize the lowest noise level in industry which bring
outs
ou tsta
tand
ndining
g ex
expeperi
rien
ence
ce to us
uses
es..

Dawn
(SEER/SCOP:A+++/A+++) 15
dB(A)

Flexis
(S
SEE
EER/
R/SC
SCOP
OP:A
:A++
+++/
+/A+
A++)
+) 16
dB(A)

Flair
(S
(SEE
EER/
EE R/SC
SCOP
OP:A
:A++
+ +/A++)
+) 19
dB(A)
Tundra Green
(S
SEE
EER/
R/SC
S OP:A
SCOP
P:A
:A++
++
++/A
+/A
/A+)
+ 20
dB(A)

11 12
In ord
rder
er to me
meetet the F-GAS AS reg
e ulation and d upgradded requirementts of energy effi fficiiency in
n EU
EU, Ha
H ier
has madede cono si
s derable investment in R&D to provide full range R32 solution which has much less
CO₂₂ em
CO emisissi
sion
on,, Be
Besi
side
de,, Hai
aier
er air con
ondi
d ti
tion
oner
e s realize the lowest noise level in industry which bring
outs
ou tsta
tand
ndining
g ex
expeperi
rien
ence
ce to us
uses
es..

Dawn
(SEER/SCOP:A+++/A+++) 15
dB(A)

Flexis
(S
SEE
EER/
R/SC
SCOP
OP:A
:A++
+++/
+/A+
A++)
+) 16
dB(A)

Flare
e
(SEE
(SEER/
EER/SC
SCOP
OP:A
:A++
++/A++)
+) 19
dB(A)
Tundra Green
(S
SEE
EER/
R/SC
S OP:A
SCOP
P:A
:A++
++
++/A
+/A
/A+)
+ 20
dB(A)

11 12
Whispering
Air

15
dB(A)

Whispering Air

Whispering Air Quiet to 15dB(A)


13 14
Whispering
Air

15
dB(A)

Whispering Air

Whispering Air Quiet to 15dB(A)


13 14
Lowest at
15dB (A)
15 Whispering Air
dB(A)

Technology

1 Optimized Air Duct Design


Benefit With optimized air duct, the air inlet area is
enlarged by 17%. The outlet area and the space Normal
mal Advanced
Enjoying whispering air [quiet to 15dB(A)] with optimized airflow system. between the evaporator and front cover are also
enlarged. It helps to increase the airflow and The wind areaa
Disturbed by the operating noise of air conditioner? Haier air conditioning upgrades the noise control with optimized air duct and cross Return
rn air area is expanded
reduce the noise.
fan design with specialized QUIET design. The wind area
The streamline spiral casing is optimized to the ture
The shell curvature
The volute onable
change is reasonable
return air in the front side and lower down loss at
the back side so as to eliminate abnormal sound The Eliminate the
omenon o
phenomenon off phenomenon of reflu
eflu
flu
ux
reflux
and enlarge airflow volume. lence
turbulence and turbulencee

10 meters away from the car


2 Optimized Cross Flow Fan Design
The cross flow fan is redesigned to be longer
than the conventional one to increase the air
Cross Flow Fan length Tubular fan
volume. By optimizing the inclination angel of increase optimization
cross flow fan blade, the airflow surrounding the
fan blade is less distorted and the fan noise is Advanced 7% 25˚
minimized.

20dB(A)

15
3 Special Design Electronic Control System
Haier air conditioning supported by the special
electronic control system, with the A-PAM DC DC Motor
dB(A) inverter technology and DC fan motor lower the
sound level of motor and provide high static
pressure capability, and also reduce the sound
level of the indoor unit. Conductor
(Note: For detailed data refer to 9000&12000BTU Dawn indoor Permanent
(Note: 15 dB(A) refers Dawn series 9000BTU model.) Magnet
unit comparing with Geos indoor unit.)

15 16
Lowest at
15dB (A)
15 Whispering Air
dB(A)

Technology

1 Optimized Air Duct Design


Benefit With optimized air duct, the air inlet area is
enlarged by 17%. The outlet area and the space Normal
mal Advanced
Enjoying whispering air [quiet to 15dB(A)] with optimized airflow system. between the evaporator and front cover are also
enlarged. It helps to increase the airflow and The wind areaa
Disturbed by the operating noise of air conditioner? Haier air conditioning upgrades the noise control with optimized air duct and cross Return
rn air area is expanded
reduce the noise.
fan design with specialized QUIET design. The wind area
The streamline spiral casing is optimized to the ture
The shell curvature
The volute onable
change is reasonable
return air in the front side and lower down loss at
the back side so as to eliminate abnormal sound The Eliminate the
omenon o
phenomenon off phenomenon of reflu
eflu
flu
ux
reflux
and enlarge airflow volume. lence
turbulence and turbulencee

10 meters away from the car


2 Optimized Cross Flow Fan Design
The cross flow fan is redesigned to be longer
than the conventional one to increase the air
Cross Flow Fan length Tubular fan
volume. By optimizing the inclination angel of increase optimization
cross flow fan blade, the airflow surrounding the
fan blade is less distorted and the fan noise is Advanced 7% 25˚
minimized.

20dB(A)

15
3 Special Design Electronic Control System
Haier air conditioning supported by the special
electronic control system, with the A-PAM DC DC Motor
dB(A) inverter technology and DC fan motor lower the
sound level of motor and provide high static
pressure capability, and also reduce the sound
level of the indoor unit. Conductor
(Note: For detailed data refer to 9000&12000BTU Dawn indoor Permanent
(Note: 15 dB(A) refers Dawn series 9000BTU model.) Magnet
unit comparing with Geos indoor unit.)

15 16
Smart
Control
Easy Installation
Easy Use
Easy Service

Smart Wi-Fi

Eco-pilot Sensor

17 18
Smart
Control
Easy Installation
Easy Use
Easy Service

Smart Wi-Fi

Eco-pilot Sensor

17 18
Wi-Fi Control

USB
Control

Benefit 2 Easy Use


1. New APP Version 2.0 “Haier Smart Air2”, updated users experience.
1 Easy Installation & Service 2. New server located at Europe offer very quick response of control.
The Wi-Fi module is designed to be a plug-in USB kit, which is very easy to install and uninstall. 3. Functions:

Su
Weekly Timer Sleep Curve
Mo
Tu Users can previously set the Four typical sleeping curves
IOS Android air conditioners on or off at are given for children, the
We
any time on any day in one aged, adult woman and
Th week and also can choose man. End users can adjust
Fr operating mode, set the sleeping curve by
Sa temperature and select fan themselves.
speed.

Error Alarm Filter Status


Error code can be shown in Detection
the APP, which will enable Regularly remind the filter
service easier. need to be cleaned and 
maintain fresh air to
increase the efficiency of air
ventilation and energy
saving.

Group Control Convenient Control


End user can not only 3G/4G End users can control the air
control one AC but also conditioners from wherever
control group AC units. through WI-FI or 3G
network.

1.Switch off power and open the panel 2.Remove Wi-Fi cover 3.Connect the USB Wi-Fi module 4. Put the Wi-Fi cover back and close the panel

19 20
Wi-Fi Control

USB
Control

Benefit 2 Easy Use


1. New APP Version 2.0 “Haier Smart Air2”, updated users experience.
1 Easy Installation & Service 2. New server located at Europe offer very quick response of control.
The Wi-Fi module is designed to be a plug-in USB kit, which is very easy to install and uninstall. 3. Functions:

Su
Weekly Timer Sleep Curve
Mo
Tu Users can previously set the Four typical sleeping curves
IOS Android air conditioners on or off at are given for children, the
We
any time on any day in one aged, adult woman and
Th week and also can choose man. End users can adjust
Fr operating mode, set the sleeping curve by
Sa temperature and select fan themselves.
speed.

Error Alarm Filter Status


Error code can be shown in Detection
the APP, which will enable Regularly remind the filter
service easier. need to be cleaned and 
maintain fresh air to
increase the efficiency of air
ventilation and energy
saving.

Group Control Convenient Control


End user can not only 3G/4G End users can control the air
control one AC but also conditioners from wherever
control group AC units. through WI-FI or 3G
network.

1.Switch off power and open the panel 2.Remove Wi-Fi cover 3.Connect the USB Wi-Fi module 4. Put the Wi-Fi cover back and close the panel

19 20
60°

Eco-pilot
Sensors
67%
Energy Saving

Benefit Technology
Eco-pilot Sensors detects and saves energy 67% in all the right way to make comfort and convenience. In order to achieve energy saving and comfort, the following methods is adopted.

High Performance Sensors


It can monitor the light intensity, the movement of the human, activity level, detect human, and then adjust the cooling ability to
achieve energy saving.

LOW
W H
HIGH

Human Sensor Light Sensor

Energy Saving

1 Eco-pilot Sensors―Human & Light Sensors


The human sensor divide the room into 6 sections. By detecting the number, location and movements of people it realizes
intelligent control on the temperature and airflow. People could choose the airflow to follow or avoid their movements.
Besides,light sensor detects changes in sunlight intensity in the room and enter the sleep mode automatically. In addition the
temperature could be automatically adjusted to energy-saving operation according to the number of people.

°
60
11.8m 2m
65º 65º
Inverter 1U12JECERA VS On/off 1U12BY3QAA (Setting temperature:23ºC with high fan speed for 3 hours)
130° 11.8m 6 5 4 3 2 1

Horizontal Sensing Area Vertical Sensing Area Detection Area

21 22
60°

Eco-pilot
Sensors
67%
Energy Saving

Benefit Technology
Eco-pilot Sensors detects and saves energy 67% in all the right way to make comfort and convenience. In order to achieve energy saving and comfort, the following methods is adopted.

High Performance Sensors


It can monitor the light intensity, the movement of the human, activity level, detect human, and then adjust the cooling ability to
achieve energy saving.

LOW
W H
HIGH

Human Sensor Light Sensor

Energy Saving

1 Eco-pilot Sensors―Human & Light Sensors


The human sensor divide the room into 6 sections. By detecting the number, location and movements of people it realizes
intelligent control on the temperature and airflow. People could choose the airflow to follow or avoid their movements.
Besides,light sensor detects changes in sunlight intensity in the room and enter the sleep mode automatically. In addition the
temperature could be automatically adjusted to energy-saving operation according to the number of people.

°
60
11.8m 2m
65º 65º
Inverter 1U12JECERA VS On/off 1U12BY3QAA (Setting temperature:23ºC with high fan speed for 3 hours)
130° 11.8m 6 5 4 3 2 1

Horizontal Sensing Area Vertical Sensing Area Detection Area

21 22
2 Follow/Avoid 4 Sunlight Detection & Automatic Control
Operates under a special program while SLEEP mode is chosen.
Follow Waking up at midnight because feeling cold with air conditioner on? Thinking to turn off the air conditioner before going
Person in single area: to send the wind in the area where the person is. asleep to save energy? Haier air conditioning has a special program designed for the night sleep so it will become not so hot
or cold at night to ensure the utmost comfort and energy saving during night sleep.
Person in two areas: the louver will be alternated with two persons, stay 15 seconds for each person.
Person in three or more areas: running every area with automatic pendulum.
Cooling Control Activity

① ② ③ ④ ⑤

Activity

Set Temperature

26°C OFF
+1°C
25°C
+1°C
24°C

Avoid Time/H 0 1 2 3 4 5 6 7 8
Person in single area: to send the wind to the most far area by opposite side.
Person in two areas: to send the wind to the most far area, if the persons are in the middle area , then the louver will be
set to both sides.
Person in three or more areas: running every area with automatic pendulum.

On-Off Card
This function is adopted in the building, hotel or other commercial
space. By connecting with room electronic circuit system, it can realize
the on-off control of air conditioner.
When people return the room, insert the room card to realize the air
conditioning automatic turn on.
When people leave the room, remove the room card to realize the air
conditioning automatic turn off.

3 Activity Detection & Automatic Control


Cooling Activity Controlling Methodology.
Wired Controller Transfer Kit
Single Mode Multi Mode
① ② ③ ④ ⑤ The device is used to connect the indoor unit with wired controller, to realize the smart wired control.
Cooling activity It can realize not only the connection between single split unit and wired controller ,but also the connection between multi split units
controlling and wired controllers.
The indicator light can enable the installer and user to easily adjust the connection status and operation status.
Set Temperature
+1
+0.5°C
Set Speed
0°C
-1
-0.5°C

0 20 40 60 80 100
Cooling Speed
Time/Min

Single User Mode:


① Average activity amount are 2, adjust 0.5 degree lower than the setting temperature, the fan speed to keep the current setting .
② Average activity amount is 1 or 0, adjust 0.5 degree higher than the setting temperature,the fan speed to keep the current setting.

Multi User Mode: Indoor Unit Wired controller transfer kit Wired controller
③ Average activity amount are 2, adjust 0.5 degree lower than the setting temperature, fan speed setting up one level.
④ Average activity amount is 1, adjust 0.5 degree higher than the setting temperature, the fan speed to keep the current setting .
⑤ Average activity amount is 0, adjust 0.5 degree higher than the setting temperature, fan speed setting down one level.

23 24
2 Follow/Avoid 4 Sunlight Detection & Automatic Control
Operates under a special program while SLEEP mode is chosen.
Follow Waking up at midnight because feeling cold with air conditioner on? Thinking to turn off the air conditioner before going
Person in single area: to send the wind in the area where the person is. asleep to save energy? Haier air conditioning has a special program designed for the night sleep so it will become not so hot
or cold at night to ensure the utmost comfort and energy saving during night sleep.
Person in two areas: the louver will be alternated with two persons, stay 15 seconds for each person.
Person in three or more areas: running every area with automatic pendulum.
Cooling Control Activity

① ② ③ ④ ⑤

Activity

Set Temperature

26°C OFF
+1°C
25°C
+1°C
24°C

Avoid Time/H 0 1 2 3 4 5 6 7 8
Person in single area: to send the wind to the most far area by opposite side.
Person in two areas: to send the wind to the most far area, if the persons are in the middle area , then the louver will be
set to both sides.
Person in three or more areas: running every area with automatic pendulum.

On-Off Card
This function is adopted in the building, hotel or other commercial
space. By connecting with room electronic circuit system, it can realize
the on-off control of air conditioner.
When people return the room, insert the room card to realize the air
conditioning automatic turn on.
When people leave the room, remove the room card to realize the air
conditioning automatic turn off.

3 Activity Detection & Automatic Control


Cooling Activity Controlling Methodology.
Wired Controller Transfer Kit
Single Mode Multi Mode
① ② ③ ④ ⑤ The device is used to connect the indoor unit with wired controller, to realize the smart wired control.
Cooling activity It can realize not only the connection between single split unit and wired controller ,but also the connection between multi split units
controlling and wired controllers.
The indicator light can enable the installer and user to easily adjust the connection status and operation status.
Set Temperature
+1
+0.5°C
Set Speed
0°C
-1
-0.5°C

0 20 40 60 80 100
Cooling Speed
Time/Min

Single User Mode:


① Average activity amount are 2, adjust 0.5 degree lower than the setting temperature, the fan speed to keep the current setting .
② Average activity amount is 1 or 0, adjust 0.5 degree higher than the setting temperature,the fan speed to keep the current setting.

Multi User Mode: Indoor Unit Wired controller transfer kit Wired controller
③ Average activity amount are 2, adjust 0.5 degree lower than the setting temperature, fan speed setting up one level.
④ Average activity amount is 1, adjust 0.5 degree higher than the setting temperature, the fan speed to keep the current setting .
⑤ Average activity amount is 0, adjust 0.5 degree higher than the setting temperature, fan speed setting down one level.

23 24
Saving 30% Installation Time Easy
Saving 60% Service Time
Installation

Easy Installation

25
5 26
Saving 30% Installation Time Easy
Saving 60% Service Time
Installation

Easy Installation

25
5 26
Saving

30 %
Installation Time

Easy
Installation

Technology

1 Mounting Plate Improvement 2 Easy Support Clip


Benefit With calibration, measure and space for tape line on
mounting plate, it is more convenient for quick positioning
It is more convenient for installation by extending space with
additional support clip, meanwhile, saving time.
and save installation time.
Advanced technology of component, system and control to make comfort easier for professional customers/users

27°

175mm

3 2-Way Drain Pipe 4 Wider Tubing Space


The indoor unit offers the possibility of left or right piping It is more convenient and save installation time to extend
direction, easy for installation. operation space for connecting pipe and wires.

48%
increase

5 Quick & Easy Repair Motor 6 Detachable Bottom Cover


It can realize motor dismounting and maintenance without With only opening decoration plate, installers can connect
disassembling evaporator. piping and wires.

27 28
Saving

30 %
Installation Time

Easy
Installation

Technology

1 Mounting Plate Improvement 2 Easy Support Clip


Benefit With calibration, measure and space for tape line on
mounting plate, it is more convenient for quick positioning
It is more convenient for installation by extending space with
additional support clip, meanwhile, saving time.
and save installation time.
Advanced technology of component, system and control to make comfort easier for professional customers/users

27°

175mm

3 2-Way Drain Pipe 4 Wider Tubing Space


The indoor unit offers the possibility of left or right piping It is more convenient and save installation time to extend
direction, easy for installation. operation space for connecting pipe and wires.

48%
increase

5 Quick & Easy Repair Motor 6 Detachable Bottom Cover


It can realize motor dismounting and maintenance without With only opening decoration plate, installers can connect
disassembling evaporator. piping and wires.

27 28
Differentiated Function Comfort Care

Long Distance
Energy Saving 20m

Air Supplying 20m+

Speed(m/s)
Airflow
Airflow
No even temperature in too big room with 8 8.0

air conditioner? Having to be seated near to


PID Inverter Control the air conditioner to enjoy the coolness or
2 2.0 1.9
warmth? Haier air conditioner, with specially
PID (Proportion Integration Differentiation) Super Cooling Curve designed cross flow fan and optimized air 1 0.8 0.7 0.4 Airflow
inverter Control realizes automatic 30 duct, can make air supply as far as 20+ Speed(m/s)
0
adjustment of temperature difference 29 meters for 24000BTU models.
5 10 15 20 23 Distance(m)

variables based on the proportional integral 28

theory. By comparison with targeted value, 27


PID Control
26
it corrects the response of error correction Normal Control
25
system. 24
23
Super Cool Comfort
Time
3D Airflow
Through horizontal and vertical movement of blades to realize the air flows upwards, downwards, left and right. Make the
customer feel comfortable at every corner of the room.

5 Vertical Stages 6 Horizontal Stages

A-PAM Inverter Control Temperature


Temperature Reducing Comparison 1
30 2 1 6
Original intelligent A-PAM(Adoption-Pulse 29 3 2 5
28 4 3 4
Amplitude Modulation) voltage adjusting 5
27
control technology automatically adjusts dc
26
bus voltage based on compressor load.
25

24

26

22 Mins
8 16 24

A-PAM
32 40

S-PAM
48
Intelligent Air
With twin air outlet blades design, according to the person's location in thefollowing diagram, the person is able to select
the direction in which the air flows out of the air conditioner, to avoid the air flow directly targeting the body.

1W Standby The airflow is directed upwards in cooling mode. The airflow is directed downwards in heating mode.

Energy
Through programme control optimization, Saving

the standby power consumption has been 88%


lowered from 8W to 1W, which realizes 88%
energy saving.( Wi-Fi standard, the standby
power consumption >1 W )

3D Motor Comfortable Sleep


Air conditioning motor is one of the core components, and also the energy consumption and noise components, DC motor is
widely used in the air conditioner due to its high efficiency and low noise, it can provide energy saving and comfortable experience
Heating operation
to users. Tempe C set
mp rature/°C
e/°C s Temperature/°C set
et
In heating operation, temperature is set to be 2°C 2
28 27
Unit stop operation
Both inside and outside unit applied DC motor, achieved high efficiency, energy saving and noise reduction via full DC motor. down in the 1st hour and another 2°C down in the 2
26
2°C
26
after 8 hours

2nd hour, after two hours, 1°C increased then Unit stop operation 1°C
24 after 8 hours 25
maintains 6 hours before the unit turns off. 2°C 1°C 1°C
2
22 24

1 Compressor Motor 2 Outdoor Motor 3 Indoor Motor 0 1 2 3 4 5 6 7 8 0 1 2 3 4 5 6 7 8

Cooling operation
In cooling operation, temperature is set to be 1°C up
in the 1st hour and another 1°C up in the 2nd hour,
then maintains 6 hours before the unit turns off.

29 30
Differentiated Function Comfort Care

Long Distance
Energy Saving 20m

Air Supplying 20m+

Speed(m/s)
Airflow
Airflow
No even temperature in too big room with 8 8.0

air conditioner? Having to be seated near to


PID Inverter Control the air conditioner to enjoy the coolness or
2 2.0 1.9
warmth? Haier air conditioner, with specially
PID (Proportion Integration Differentiation) Super Cooling Curve designed cross flow fan and optimized air 1 0.8 0.7 0.4 Airflow
inverter Control realizes automatic 30 duct, can make air supply as far as 20+ Speed(m/s)
0
adjustment of temperature difference 29 meters for 24000BTU models.
5 10 15 20 23 Distance(m)

variables based on the proportional integral 28

theory. By comparison with targeted value, 27


PID Control
26
it corrects the response of error correction Normal Control
25
system. 24
23
Super Cool Comfort
Time
3D Airflow
Through horizontal and vertical movement of blades to realize the air flows upwards, downwards, left and right. Make the
customer feel comfortable at every corner of the room.

5 Vertical Stages 6 Horizontal Stages

A-PAM Inverter Control Temperature


Temperature Reducing Comparison 1
30 2 1 6
Original intelligent A-PAM(Adoption-Pulse 29 3 2 5
28 4 3 4
Amplitude Modulation) voltage adjusting 5
27
control technology automatically adjusts dc
26
bus voltage based on compressor load.
25

24

26

22 Mins
8 16 24

A-PAM
32 40

S-PAM
48
Intelligent Air
With twin air outlet blades design, according to the person's location in thefollowing diagram, the person is able to select
the direction in which the air flows out of the air conditioner, to avoid the air flow directly targeting the body.

1W Standby The airflow is directed upwards in cooling mode. The airflow is directed downwards in heating mode.

Energy
Through programme control optimization, Saving

the standby power consumption has been 88%


lowered from 8W to 1W, which realizes 88%
energy saving.( Wi-Fi standard, the standby
power consumption >1 W )

3D Motor Comfortable Sleep


Air conditioning motor is one of the core components, and also the energy consumption and noise components, DC motor is
widely used in the air conditioner due to its high efficiency and low noise, it can provide energy saving and comfortable experience
Heating operation
to users. Tempe C set
mp rature/°C
e/°C s Temperature/°C set
et
In heating operation, temperature is set to be 2°C 2
28 27
Unit stop operation
Both inside and outside unit applied DC motor, achieved high efficiency, energy saving and noise reduction via full DC motor. down in the 1st hour and another 2°C down in the 2
26
2°C
26
after 8 hours

2nd hour, after two hours, 1°C increased then Unit stop operation 1°C
24 after 8 hours 25
maintains 6 hours before the unit turns off. 2°C 1°C 1°C
2
22 24

1 Compressor Motor 2 Outdoor Motor 3 Indoor Motor 0 1 2 3 4 5 6 7 8 0 1 2 3 4 5 6 7 8

Cooling operation
In cooling operation, temperature is set to be 1°C up
in the 1st hour and another 1°C up in the 2nd hour,
then maintains 6 hours before the unit turns off.

29 30
Health Care User Friendly

Nano-aqua Ionizer R32 Refrigerant


Haier unique Nano-aqua ionizer can ionize water molecules into H+ and O- as well as small cluster of water, which can keep
your skin moist and have the effect of air purification. R32 has a number of interesting environmental.
Compared to the commonly used refrigerant R410A, the Global Warming potential of R32 is nearly one third (GWP is 675 for
Skin Care Ionizer 99% Sterilized Air R32 compared to 2088 for R410A), while it allows for a much smaller refrigerant volume and high energy efficiency.
As a single component refrigerant, R32 is also easier to recycle and reuse, which is another environmental bonus.
Nano aquaa
Nano-aqu In addition, R32 is easy to handle for installers and service technicians as it can be charged in both liquid and gas phase and
Waterr molecu
Wate molecules
les diam
diameter
eterr diameter

H+
8000nm
800 0nm 20~50nm working pressures are similar to R410A. There is also no need to worry about fractionation or glide problems as R32 is not a
OH
blend refrigerant.
H H
OH OH
H H

Cuticle
ic Cut
utiiicle
cle
l O- OH H H OH
OH
20% 5%
R410A
The water molecule in the air Nano-aqua 68%
R32

3M Purify Filter
Haier air conditioner with 3M purify filter system ensure that the air inside your home is free of various harmful such as hair, R32 GWP= 675, 68% less than R32 is about 20% less charge than R32 provide 5% higher energy
dust mites, pollen, fungi spores, bacteria, exhaust fumes and smoke. These 3M purify filter together capture both visible R410A GWP=2088 R410A to reach same capacity efficiency than R410A

and invisible dust and other harmful microscopic substances.

Super Match
-

- 100% free combination, 51% less stock


- For offices and apartments, villas and shops, Haier Air Conditioning provides total residential and light commercial solution
-
with innovative SUPER MATCH series. Stock management is made easy. Just imagine the saving in warehouse space, spare
parts and logistics that all translate into cash-flow in your balance sheets.
-
1 Greatly reduce models, spare parts, convenient for management;
2 Reduce storage;
3 Reduce operating cash flow;
4 Easy Combination and maintenance.
Multi-layers Filter
The filter is durable which could automatically release negative ion, and has antibacterial, deodorizing function.

Single split
DC inverter

Photocatalyst filter Vitamin C layer

Single split
on/off

Multi split
DC inverter

Universal outdoor unit for high-wall, console, cassette, convertible, duct and cabinet. Universal indoor unit for single or multi split outdoor unit, no matter inverter or on/off.
Activated carbon Bacteria-killing medium

31 32
Health Care User Friendly

Nano-aqua Ionizer R32 Refrigerant


Haier unique Nano-aqua ionizer can ionize water molecules into H+ and O- as well as small cluster of water, which can keep
your skin moist and have the effect of air purification. R32 has a number of interesting environmental.
Compared to the commonly used refrigerant R410A, the Global Warming potential of R32 is nearly one third (GWP is 675 for
Skin Care Ionizer 99% Sterilized Air R32 compared to 2088 for R410A), while it allows for a much smaller refrigerant volume and high energy efficiency.
As a single component refrigerant, R32 is also easier to recycle and reuse, which is another environmental bonus.
Nano aquaa
Nano-aqu In addition, R32 is easy to handle for installers and service technicians as it can be charged in both liquid and gas phase and
Waterr molecu
Wate molecules
les diam
diameter
eterr diameter

H+
8000nm
800 0nm 20~50nm working pressures are similar to R410A. There is also no need to worry about fractionation or glide problems as R32 is not a
OH
blend refrigerant.
H H
OH OH
H H

Cuticle
ic Cut
utiiicle
cle
l O- OH H H OH
OH
20% 5%
R410A
The water molecule in the air Nano-aqua 68%
R32

3M Purify Filter
Haier air conditioner with 3M purify filter system ensure that the air inside your home is free of various harmful such as hair, R32 GWP= 675, 68% less than R32 is about 20% less charge than R32 provide 5% higher energy
dust mites, pollen, fungi spores, bacteria, exhaust fumes and smoke. These 3M purify filter together capture both visible R410A GWP=2088 R410A to reach same capacity efficiency than R410A

and invisible dust and other harmful microscopic substances.

Super Match
-

- 100% free combination, 51% less stock


- For offices and apartments, villas and shops, Haier Air Conditioning provides total residential and light commercial solution
-
with innovative SUPER MATCH series. Stock management is made easy. Just imagine the saving in warehouse space, spare
parts and logistics that all translate into cash-flow in your balance sheets.
-
1 Greatly reduce models, spare parts, convenient for management;
2 Reduce storage;
3 Reduce operating cash flow;
4 Easy Combination and maintenance.
Multi-layers Filter
The filter is durable which could automatically release negative ion, and has antibacterial, deodorizing function.

Single split
DC inverter

Photocatalyst filter Vitamin C layer

Single split
on/off

Multi split
DC inverter

Universal outdoor unit for high-wall, console, cassette, convertible, duct and cabinet. Universal indoor unit for single or multi split outdoor unit, no matter inverter or on/off.
Activated carbon Bacteria-killing medium

31 32
Icon Guide
2-way Piping Design Self-diagnosis Super Match
The indoor unit offers the possibility of left The LED display of the indoor units will The innovative SUPERMATCH range realizes
and right piping direction, easy for show the error code in order to make universal indoor & outdooor 100% free
installation. service more easier. combination,which make management of
sales,warehouse and spare parts much more
easier and more efficient.

Silent & Comfort Super Match II+ Easy Clean Design Consealed LED Display
The indoor unit offers the possibility of left The indoor front panel is easy to wash and Special designed panel and LED display which make it
and right piping direction, easy for the air flaps are easy to detach without any possible to show the working states and functions
installation. special tools for quick cleaning. only when the unit on while the display and frame can
not be seen when unit off in order to keep indoor
decoration with sense of wholeness. Of course you
can cancel the display whenever you want.
Whispering Air Comfortable Sleep 3D Airflow
15
Optimize the noise control The setting temperature and the indoor The 3D airflow is able to deliver the airflow
technology,such as frequency noise can be adjusted to a more horizontally and vertically, so bring the
dB(A) adjustment,fan speed control and air flue comfortable level when you set the "sleep feeling like nature wind.
design decreasing noise level lowest to 15 mode" during night sleep.
Double 8 Display Long Life Reliable PCB DIY Auto Mode
dB(A) . (Refer to Dawn 9k).
Simple 88 display shows clearly the indoor Haier PCB is tested 96 hours under hard You can set a temperature value, with which
unit setting temperature(when setting) or enviroment temperature 85ºC & moisture the unit can adjust the operation mode
room temperature(after setting). 85%, this test condition is more or less 10 automatically.
years under normal condition.

Long Distance Air Supplying Intelligent Air Carpet Airflow


The indoor unit is improved by the Airflow automatically upward when The special designed function for console
optimized motor, fan and air duct so as to cooling or downward when heating to type makes the possibility of airflow
provide long distance airflow with 20m+ spread air automatically throughout the blowing along with the floor level so as to
20m maximum. (refer to Nebula 24k). large room while without blowing directly provide the extreme comfort like warm Auto Mode Auto Restart Wide Voltage For Inverter
to human body. carpet especially in the winter bed room.
According to the fixed temperature 26°C The function permits automatic return to The inverter unit can start up from 150V and
(under cooling)or 23°C(under heating), the previous operation conditions after a sudden operate in a wide voltage range from
unit will adjust the operation mode power break. 150V-264V.
automatically.

-30°C Heating -15°C Heating -15°C Cooling


A special design for heating in cold winter A special design for heating in cold winter A special design for cooling even at lowest
even at -30°C with rotary compressor,DC
motor,optimized bottom plate,electric
even at -15°C with rotary compressor, etc. 5 ambient temperature -15°C with high
frequency rotary compressor,optimized
heating wire and special defrosting refrigerant system and special defrosting Integrative Structure Design Integrative Valve Cover Blue Fin
programme etc. programme etc.
The optimized design integrates the This valve cover is designed to cover both The hydrophilic aluminum foil makes
bottom base, drain pan and frame casing wiring terminal block and stop valves so as to condensing water flow smoothly so
together so as to level up product reliability enhance protect effect with nice design. guarantee the better performance with
and lower vibration. anti-corrosion effect.

-10°C Cooling Precise Temp Control 0.5°C DRY Function


Special design for cooling even at lowest When the unit working in dry mode, it can
Can make the setting temperature by adjust the indoor fan motor speed
ambient temperature -10ºC with high 0.5°C so to achieve more precise comfort
frequency rotary compressor, optimized automatically according to the temperature
refrigerant system and special defrosting 0.5 and energy saving. gap between setting temperature and room
temperature so as to get mild
program etc.
dehumidification or strong dehumidification.

Quiet Mode 3 Minutes Protection Smart Defrosting


Just press the button “turbo/quiet” on the The 3 minutes protection of the Haier smart defrost process is only performed
remote controller, the air conditioner will compressor can avoid some damages to when needed which reduces energy waste by

Energy Saving
work in quiet mode. it and makes the compressor have a eliminating the unneeded defrosting
longer life. process.Enjoy maximum comfort in heating
operation by reducing defrosting time.

Electrical Deicer Indoor 5 Steps Fan Speed Double Horizontal Flaps Airflow PID Inverter Control A-PAM Inverter Control 1W Standby
The outdoor bottom plate is equipped The indoor can be remote controlled with With two horizontal flaps and two step PID Inverter Control can realize automatic A-PAM inverter technology is the upgrade of Through programme control optimization, the
with a special designed electrical heating 5 steps of fan motors , they can realize more positions (4 adjustment of temperature difference 180°sine wave inverter , it adopts additional stand-by power consumption has been
wire to deicer in the cold winter. speed:powerful/high/middle/low/quiet, positions for cooling and 5 positions for variables based on the proportional integral momental control to decrease the vibration lowered from 8W to 1W ,which realizes 88%
which offer more choice for you to get heating) and two intelligent angle to get theory, through comparison with targeted in the low compressor frequency and also energy saving .
comfort airflow. more comfort airflow. value, to correct the response of error contribute to great energy saving.
correction system.

Warm Start Auto Vertical Airflow 3D Motor 10°C Heating Maintenance 24 Hours Timer
when the unit start working at heating With one special step motor to adjust the DC motor ensures more reliable It is possible to set the system to switch on Use the timer function to set on, or off, or
mode,or change from cooling mode to horizontal flaps moving vertically and operation with much higher energy saving when indoor temp. drop below 10°C,thus from on to off, or from off to on etc, within
heating mode,the unit will not blow or blow automatically,it can realize 5 positions and lower noise. avoiding pipes frozen , and provide winter 24 hours.
at super low speed in order to avoid cold air angle,2 intelligent air angle and total protection for unoccupied summer
air disturbance. auto blowing, when the unit is switched house,garages and basements.
off, the flap will close automatically.

Outdoor 6 Steps Fan Speed Outdoor 7 Steps Fan Speed


The outdoor is designed with 6 steps of fan The outdoor is designed with 7 steps of fan

Smart Control
speed, the fan speed can be automaticlly speed, the fan speed can be automaticlly
adjusted according to the intelligent control adjusted according to the intelligent control
of ambient sensor and tubing sensor so that of ambient sensor and tubing sensor so that
optimize the heat exchanging effect and optimize the heat exchanging effect and
improve energy efficiency. improve energy efficiency.

Wi-Fi Control Eco-pilot Sensors Eco Sensor


Control your air conditioning system with Automatically adjust operation frequency Double human sense integrated module,
smart phone or tablet which can connect and modes to save energy, improve double area detection , detection angle
internet. comfort and convenience by monitoring 120°(horizontal), detection distance within
human location,movements, absence with 8m.
2 human activity sensors.

Wired Controller Transfer Kit On-Off Card


The indoor unit connect the wired
controller by wired controller transfer kit.
Control the system with a room card in
the remote place through the level signal.
It is widely adopted in the building, hotel or
other commercial space. Convenient for
Health Care
management.

Nano-aqua Ionizer 3M Filter Evaporator Self-cleaning


Haier unique Aqua generator can ionize The advanced 3M purify filter employs a With a new-generation hydrophilic foil,
water molecules into H+ and O2- as well strong electrostatic charge on its surface when the air conditioner in cooling or
as small cluster of water , which can keep to remove harmful micro-particles including drying mode, the dust on evaporator will

User Friendly
your skin moist and have the effect of air dust,virus and bacteria to provide a be taken away by condensed water
purification. safer,healthier indoor environment. flowing rapidly.

Easy Support Clip Detachable Bottom Cover Easy & Quick Repair Motor Multi-layers Filter
It is more convenient for installation by With only opening decoration plate, It can realize motor dismounting and The filter is durable which could
extending space with additional support installers can connect piping and wires. maintenance without disassembling automatically release negative ion, and
clip, meanwhile, saving time. The triangle logo on bottom of casing can evaporator. has antibacterial, deodorizing function.
help to position mounting plate.

33 34
Icon Guide
2-way Piping Design Self-diagnosis Super Match
The indoor unit offers the possibility of left The LED display of the indoor units will The innovative SUPERMATCH range realizes
and right piping direction, easy for show the error code in order to make universal indoor & outdooor 100% free
installation. service more easier. combination,which make management of
sales,warehouse and spare parts much more
easier and more efficient.

Silent & Comfort Super Match II+ Easy Clean Design Consealed LED Display
The indoor unit offers the possibility of left The indoor front panel is easy to wash and Special designed panel and LED display which make it
and right piping direction, easy for the air flaps are easy to detach without any possible to show the working states and functions
installation. special tools for quick cleaning. only when the unit on while the display and frame can
not be seen when unit off in order to keep indoor
decoration with sense of wholeness. Of course you
can cancel the display whenever you want.
Whispering Air Comfortable Sleep 3D Airflow
15
Optimize the noise control The setting temperature and the indoor The 3D airflow is able to deliver the airflow
technology,such as frequency noise can be adjusted to a more horizontally and vertically, so bring the
dB(A) adjustment,fan speed control and air flue comfortable level when you set the "sleep feeling like nature wind.
design decreasing noise level lowest to 15 mode" during night sleep.
Double 8 Display Long Life Reliable PCB DIY Auto Mode
dB(A) . (Refer to Dawn 9k).
Simple 88 display shows clearly the indoor Haier PCB is tested 96 hours under hard You can set a temperature value, with which
unit setting temperature(when setting) or enviroment temperature 85ºC & moisture the unit can adjust the operation mode
room temperature(after setting). 85%, this test condition is more or less 10 automatically.
years under normal condition.

Long Distance Air Supplying Intelligent Air Carpet Airflow


The indoor unit is improved by the Airflow automatically upward when The special designed function for console
optimized motor, fan and air duct so as to cooling or downward when heating to type makes the possibility of airflow
provide long distance airflow with 20m+ spread air automatically throughout the blowing along with the floor level so as to
20m maximum. (refer to Nebula 24k). large room while without blowing directly provide the extreme comfort like warm Auto Mode Auto Restart Wide Voltage For Inverter
to human body. carpet especially in the winter bed room.
According to the fixed temperature 26°C The function permits automatic return to The inverter unit can start up from 150V and
(under cooling)or 23°C(under heating), the previous operation conditions after a sudden operate in a wide voltage range from
unit will adjust the operation mode power break. 150V-264V.
automatically.

-30°C Heating -15°C Heating -15°C Cooling


A special design for heating in cold winter A special design for heating in cold winter A special design for cooling even at lowest
even at -30°C with rotary compressor,DC
motor,optimized bottom plate,electric
even at -15°C with rotary compressor, etc. 5 ambient temperature -15°C with high
frequency rotary compressor,optimized
heating wire and special defrosting refrigerant system and special defrosting Integrative Structure Design Integrative Valve Cover Blue Fin
programme etc. programme etc.
The optimized design integrates the This valve cover is designed to cover both The hydrophilic aluminum foil makes
bottom base, drain pan and frame casing wiring terminal block and stop valves so as to condensing water flow smoothly so
together so as to level up product reliability enhance protect effect with nice design. guarantee the better performance with
and lower vibration. anti-corrosion effect.

-10°C Cooling Precise Temp Control 0.5°C DRY Function


Special design for cooling even at lowest When the unit working in dry mode, it can
Can make the setting temperature by adjust the indoor fan motor speed
ambient temperature -10ºC with high 0.5°C so to achieve more precise comfort
frequency rotary compressor, optimized automatically according to the temperature
refrigerant system and special defrosting 0.5 and energy saving. gap between setting temperature and room
temperature so as to get mild
program etc.
dehumidification or strong dehumidification.

Quiet Mode 3 Minutes Protection Smart Defrosting


Just press the button “turbo/quiet” on the The 3 minutes protection of the Haier smart defrost process is only performed
remote controller, the air conditioner will compressor can avoid some damages to when needed which reduces energy waste by

Energy Saving
work in quiet mode. it and makes the compressor have a eliminating the unneeded defrosting
longer life. process.Enjoy maximum comfort in heating
operation by reducing defrosting time.

Electrical Deicer Indoor 5 Steps Fan Speed Double Horizontal Flaps Airflow PID Inverter Control A-PAM Inverter Control 1W Standby
The outdoor bottom plate is equipped The indoor can be remote controlled with With two horizontal flaps and two step PID Inverter Control can realize automatic A-PAM inverter technology is the upgrade of Through programme control optimization, the
with a special designed electrical heating 5 steps of fan motors , they can realize more positions (4 adjustment of temperature difference 180°sine wave inverter , it adopts additional stand-by power consumption has been
wire to deicer in the cold winter. speed:powerful/high/middle/low/quiet, positions for cooling and 5 positions for variables based on the proportional integral momental control to decrease the vibration lowered from 8W to 1W ,which realizes 88%
which offer more choice for you to get heating) and two intelligent angle to get theory, through comparison with targeted in the low compressor frequency and also energy saving .
comfort airflow. more comfort airflow. value, to correct the response of error contribute to great energy saving.
correction system.

Warm Start Auto Vertical Airflow 3D Motor 10°C Heating Maintenance 24 Hours Timer
when the unit start working at heating With one special step motor to adjust the DC motor ensures more reliable It is possible to set the system to switch on Use the timer function to set on, or off, or
mode,or change from cooling mode to horizontal flaps moving vertically and operation with much higher energy saving when indoor temp. drop below 10°C,thus from on to off, or from off to on etc, within
heating mode,the unit will not blow or blow automatically,it can realize 5 positions and lower noise. avoiding pipes frozen , and provide winter 24 hours.
at super low speed in order to avoid cold air angle,2 intelligent air angle and total protection for unoccupied summer
air disturbance. auto blowing, when the unit is switched house,garages and basements.
off, the flap will close automatically.

Outdoor 6 Steps Fan Speed Outdoor 7 Steps Fan Speed


The outdoor is designed with 6 steps of fan The outdoor is designed with 7 steps of fan

Smart Control
speed, the fan speed can be automaticlly speed, the fan speed can be automaticlly
adjusted according to the intelligent control adjusted according to the intelligent control
of ambient sensor and tubing sensor so that of ambient sensor and tubing sensor so that
optimize the heat exchanging effect and optimize the heat exchanging effect and
improve energy efficiency. improve energy efficiency.

Wi-Fi Control Eco-pilot Sensors Eco Sensor


Control your air conditioning system with Automatically adjust operation frequency Double human sense integrated module,
smart phone or tablet which can connect and modes to save energy, improve double area detection , detection angle
internet. comfort and convenience by monitoring 120°(horizontal), detection distance within
human location,movements, absence with 8m.
2 human activity sensors.

Wired Controller Transfer Kit On-Off Card


The indoor unit connect the wired
controller by wired controller transfer kit.
Control the system with a room card in
the remote place through the level signal.
It is widely adopted in the building, hotel or
other commercial space. Convenient for
Health Care
management.

Nano-aqua Ionizer 3M Filter Evaporator Self-cleaning


Haier unique Aqua generator can ionize The advanced 3M purify filter employs a With a new-generation hydrophilic foil,
water molecules into H+ and O2- as well strong electrostatic charge on its surface when the air conditioner in cooling or
as small cluster of water , which can keep to remove harmful micro-particles including drying mode, the dust on evaporator will

User Friendly
your skin moist and have the effect of air dust,virus and bacteria to provide a be taken away by condensed water
purification. safer,healthier indoor environment. flowing rapidly.

Easy Support Clip Detachable Bottom Cover Easy & Quick Repair Motor Multi-layers Filter
It is more convenient for installation by With only opening decoration plate, It can realize motor dismounting and The filter is durable which could
extending space with additional support installers can connect piping and wires. maintenance without disassembling automatically release negative ion, and
clip, meanwhile, saving time. The triangle logo on bottom of casing can evaporator. has antibacterial, deodorizing function.
help to position mounting plate.

33 34
Models Line-up
Type Series Refrigerant Remote 20 25 35 42 50 71 Mono Outdoor Multi Outdoor
Type Controller

Dawn R32 2U40S2SC1FA


2U50S2SF1FA

Multi Only A+++/A+++ A+++/A++ Multi Only(except 1by2)

Seasonal R32 New


SuperMatch Flexis R32
2U40S2SC1FA
2U50S2SF1FA
R32 Multi Only A+++/A++ A+++/A++ A++/A++ A++/A+
Models
New
Line-up
Flair R32 2U40S2SC1FA
2U50S2SF1FA

Multi Only A+++/A++ A+++/A++ A++/A++ A++/A+

Tundra
Seasonal R32 R32
Green
A++/A+ A++/A+ A++/A+ A++/A+

Type Series Refrigerant Remote 7 9 12 15 18 24 Mono Outdoor Multi Outdoor


Type Controller

Seasonal Crystal R410A


High (Nordic)
A+++/A++ A++/A+

R410A
Nebula
Multi Only A++/A+ A++/A+ A++/A+ A++/A+ A++/A+

Seasonal
SuperMatch R410A
Brezza
Multi Only A++/A+ A++/A+ A++/A+ A++/A+ A++/A+
2U14CS4ERA
2U18FS2ERA(S)

R410A R410A
Models Console

Line-up A/A A/A

Seasonal R410A
Basic Tundra 2U18FS2ERA(S)

A++/A+ A++/A+ A++/A+ A++/A

R410A
Cabinet Cabinet A++/A+

Portable Portable R410A


AC AC

Split Wall Mounted Split Wall Mounted Floor


Dawn Flexis Flare Nebula Brezza Console
Indoor Units Indoor Units
20 25 35 42 20 25 35 50 71 20 25 35 50 71 7 9 12 15 18 24 7 9 12 15 18 24 9 12
2U40S2SC1FA 2U14CS4ERA

2U50S2SF1FA 2U18FS2ERA(S)
Note:More Multi models see the CAC catalogue.

35 36
Models Line-up
Type Series Refrigerant Remote 20 25 35 42 50 71 Mono Outdoor Multi Outdoor
Type Controller

Dawn R32 2U40S2SC1FA


2U50S2SF1FA

Multi Only A+++/A+++ A+++/A++ Multi Only(except 1by2)

Seasonal R32 New


SuperMatch Flexis R32
2U40S2SC1FA
2U50S2SF1FA
R32 Multi Only A+++/A++ A+++/A++ A++/A++ A++/A+
Models
New
Line-up
Flare R32 2U40S2SC1FA
2U50S2SF1FA

Multi Only A+++/A++ A+++/A++ A++/A++ A++/A+

Tundra
Seasonal R32 R32
Green
A++/A+ A++/A+ A++/A+ A++/A+

Type Series Refrigerant Remote 7 9 12 15 18 24 Mono Outdoor Multi Outdoor


Type Controller

Seasonal Crystal R410A


High (Nordic)
A+++/A++ A++/A+

R410A
Nebula
Multi Only A++/A+ A++/A+ A++/A+ A++/A+ A++/A+

Seasonal
SuperMatch R410A
Brezza
Multi Only A++/A+ A++/A+ A++/A+ A++/A+ A++/A+
2U14CS4ERA
2U18FS2ERA(S)

R410A R410A
Models Console

Line-up A/A A/A

Seasonal R410A
Basic Tundra 2U18FS2ERA(S)

A++/A+ A++/A+ A++/A+ A++/A

R410A
Cabinet Cabinet A++/A+

Portable Portable R410A


AC AC

Split Wall Mounted Split Wall Mounted Floor


Dawn Flexis Flare Nebula Brezza Console
Indoor Units Indoor Units
20 25 35 42 20 25 35 50 71 20 25 35 50 71 7 9 12 15 18 24 7 9 12 15 18 24 9 12
2U40S2SC1FA 2U14CS4ERA

2U50S2SF1FA 2U18FS2ERA(S)
Note:More Multi models see the CAC catalogue.

35 36
Benefits
Smart Control Energy Saving Silent & Comfort
Series Capacity 12m+ 0.5

Wi-Fi Eco-pilot Eco Wired Controller On-Off PID A-PAM 180° Sine Wave 1W Standby 10°C Heating 3D Motor 24 Hours Outdoor 6 Outdoor 7 Whispering Comfortable 3D Airflow Long Distance Intelligent Air Carpet Airflow -30°C Heating -15°C Heating-10°C Cooling Quiet Mode Precise Temp DRY Warm 3 Minutes Smart Electrical Indoor 5 StepsDouble Horizontal Auto Vertical
Control Sensors Sensors Transfer Kit Card Inverter Control Inverter Control DC Inverter Maintenance Timer Steps Steps Air Sleep Air Supplying Control 0.5°c Function Start Protection Defrosting Deicer Fan Speed Flaps Airflow Airflow
Fan Speed Fan Speed

20 ȕ ȕ ȓ ȓ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ

25 ȕ ȕ ȓ ȓ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ
Dawn
35 ȕ ȕ ȓ ȓ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ

42 ȕ ȕ ȓ ȓ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ

20 ȓ ȕ ȓ ȓ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ

25 ȓ ȕ ȓ ȓ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ

Flexis 35 ȓ ȕ ȓ ȓ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ

50 ȓ ȕ ȓ ȓ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ

71 ȓ ȕ ȓ ȓ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ

20 ȓ ȓ ȓ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ

25 ȓ ȓ ȓ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ

Flair 35 ȓ ȓ ȓ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ

50 ȓ ȓ ȓ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ

71 ȓ ȓ ȓ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ

25 ȓ ȓ ȓ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ

Tundra 35 ȓ ȓ ȓ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ

Green 50 ȓ ȓ ȓ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ

68 ȓ ȓ ȓ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ

9 ȕ ȓ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ
Crystal
12 ȕ ȓ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ

7 ȕ ȓ ȓ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ

9 ȕ ȓ ȓ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ

12 ȕ ȓ ȓ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ
Nebula
15 ȕ ȓ ȓ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ

18 ȕ ȓ ȓ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ

24 ȕ ȓ ȓ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ

7 ȓ ȓ ȓ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ

9 ȓ ȓ ȓ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ

12 ȓ ȓ ȓ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ
Brezza
15 ȓ ȓ ȓ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ

18 ȓ ȓ ȓ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ

24 ȓ ȓ ȓ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ

9 ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ
Console
12 ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ

9 ȓ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ

12 ȓ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ
Tundra
18 ȓ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ

24 ȓ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ

Cabinett 24 ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ

37 38 ƽ : Standard ƻ : Optional
Benefits
Smart Control Energy Saving Silent & Comfort
Series Capacity 12m+ 0.5

Wi-Fi Eco-pilot Eco Wired Controller On-Off PID A-PAM 180° Sine Wave 1W Standby 10°C Heating 3D Motor 24 Hours Outdoor 6 Outdoor 7 Whispering Comfortable 3D Airflow Long Distance Intelligent Air Carpet Airflow -30°C Heating -15°C Heating-10°C Cooling Quiet Mode Precise Temp DRY Warm 3 Minutes Smart Electrical Indoor 5 StepsDouble Horizontal Auto Vertical
Control Sensors Sensors Transfer Kit Card Inverter Control Inverter Control DC Inverter Maintenance Timer Steps Steps Air Sleep Air Supplying Control 0.5°c Function Start Protection Defrosting Deicer Fan Speed Flaps Airflow Airflow
Fan Speed Fan Speed

20 ȕ ȕ ȓ ȓ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ

25 ȕ ȕ ȓ ȓ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ
Dawn
35 ȕ ȕ ȓ ȓ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ

42 ȕ ȕ ȓ ȓ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ

20 ȓ ȕ ȓ ȓ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ

25 ȓ ȕ ȓ ȓ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ

Flexis 35 ȓ ȕ ȓ ȓ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ

50 ȓ ȕ ȓ ȓ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ

71 ȓ ȕ ȓ ȓ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ

20 ȓ ȓ ȓ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ

25 ȓ ȓ ȓ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ

Flare 35 ȓ ȓ ȓ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ

50 ȓ ȓ ȓ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ

71 ȓ ȓ ȓ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ

25 ȓ ȓ ȓ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ

Tundra 35 ȓ ȓ ȓ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ

Green 50 ȓ ȓ ȓ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ

68 ȓ ȓ ȓ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ

9 ȕ ȓ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ
Crystal
12 ȕ ȓ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ

7 ȕ ȓ ȓ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ

9 ȕ ȓ ȓ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ

12 ȕ ȓ ȓ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ
Nebula
15 ȕ ȓ ȓ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ

18 ȕ ȓ ȓ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ

24 ȕ ȓ ȓ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ

7 ȓ ȓ ȓ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ

9 ȓ ȓ ȓ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ

12 ȓ ȓ ȓ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ
Brezza
15 ȓ ȓ ȓ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ

18 ȓ ȓ ȓ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ

24 ȓ ȓ ȓ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ

9 ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ
Console
12 ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ

9 ȓ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ

12 ȓ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ
Tundra
18 ȓ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ

24 ȓ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ

Cabinett 24 ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ

37 38 ƽ : Standard ƻ : Optional
Benefits
Health Care User Friendly
Series
Capacity Nano-aqua 3M Filter Negative Ion Evaporator Exquisite Multi-layers Easy Support Detachable Easy & Quick 2-way Self-diagnosis Super Match Super Match II+ Easy Clean Consealed Double 8 Long Life DIY Auto Auto Auto Wide Voltage Integrative Integrative Blue Fin
Self-cleaning Dust Filter Filter Clip Bottom Cover Repair motor Piping Design Design LED Display Display Reliable PCB Mode Mode restart For Inverter Structure Design Valve Cover

20 ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ

25 ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ
Dawn
35 ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ

42 ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ

20 ȓ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ

25 ȓ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ

Flexis 35 ȓ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ

50 ȓ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ

71 ȓ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ

20 ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ

25 ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ

Flair 35 ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ

50 ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ

71 ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ

25 ȕ ȕ ȓ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ

Tundra 35 ȕ ȕ ȓ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ

Green 50 ȕ ȕ ȓ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ

68 ȕ ȕ ȓ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ

9 ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ
Crystal
12 ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ

7 ȕ ȕ ȕ ȓ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ

9 ȕ ȕ ȕ ȓ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ

12 ȕ ȕ ȕ ȓ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ
Nebula
15 ȕ ȕ ȕ ȓ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ

18 ȕ ȕ ȕ ȓ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ

24 ȕ ȕ ȕ ȓ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ

7 ȕ ȕ ȓ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ

9 ȕ ȕ ȓ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ

12 ȕ ȕ ȓ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ
Brezza
15 ȕ ȕ ȓ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ

18 ȕ ȕ ȓ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ

24 ȕ ȕ ȓ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ

9 ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ
Console
12 ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ

9 ȕ ȕ ȓ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ

12 ȕ ȕ ȓ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ
Tundra
18 ȕ ȕ ȓ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ

24 ȕ ȕ ȓ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ

Cabinett 24 ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ

39 40 ƽ : Standard ƻ : Optional
Benefits
Health Care User Friendly
Series
Capacity Nano-aqua 3M Filter Negative Ion Evaporator Exquisite Multi-layers Easy Support Detachable Easy & Quick 2-way Self-diagnosis Super Match Super Match II+ Easy Clean Consealed Double 8 Long Life DIY Auto Auto Auto Wide Voltage Integrative Integrative Blue Fin
Self-cleaning Dust Filter Filter Clip Bottom Cover Repair motor Piping Design Design LED Display Display Reliable PCB Mode Mode restart For Inverter Structure Design Valve Cover

20 ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ

25 ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ
Dawn
35 ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ

42 ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ

20 ȓ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ

25 ȓ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ

Flexis 35 ȓ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ

50 ȓ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ

71 ȓ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ

20 ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ

25 ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ

Flare 35 ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ

50 ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ

71 ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ

25 ȕ ȕ ȓ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ

Tundra 35 ȕ ȕ ȓ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ

Green 50 ȕ ȕ ȓ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ

68 ȕ ȕ ȓ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ

9 ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ
Crystal
12 ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ

7 ȕ ȕ ȕ ȓ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ

9 ȕ ȕ ȕ ȓ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ

12 ȕ ȕ ȕ ȓ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ
Nebula
15 ȕ ȕ ȕ ȓ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ

18 ȕ ȕ ȕ ȓ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ

24 ȕ ȕ ȕ ȓ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ

7 ȕ ȕ ȓ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ

9 ȕ ȕ ȓ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ

12 ȕ ȕ ȓ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ
Brezza
15 ȕ ȕ ȓ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ

18 ȕ ȕ ȓ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ

24 ȕ ȕ ȓ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ

9 ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ
Console
12 ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ

9 ȕ ȕ ȓ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ

12 ȕ ȕ ȓ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ
Tundra
18 ȕ ȕ ȓ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ

24 ȕ ȕ ȓ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ

Cabinett 24 ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ ȕ

39 40 ƽ : Standard ƻ : Optional
Whispering
Air

Seasonal Green R32


15
dB(A) Dawn Series
16
dB(A) Flexis Series
19
dB(A) Flare Series
20
dB(A) Tundra Green Series

Seasonal Nordic
19
dB(A) Crystal Series (for Nordic)

Seasonal Super Match


20
dB(A) Nebula Series
20
dB(A) Brezza Series

Seasonal Basic
20
dB(A)
Tundra Series

41 42
Whispering
Air

Seasonal Green R32


15
dB(A) Dawn Series
16
dB(A)
Flexis Series
19
dB(A) Flair Series
20
dB(A) Tundra Green Series

Seasonal Nordic
19
dB(A) Crystal Series (for Nordic)

Seasonal Super Match


20
dB(A) Nebula Series
20
dB(A) Brezza Series

Seasonal Basic
20
dB(A)
Tundra Series

41 42
Key Features Features

• 3D Airflow
• Easy Support Clip
15
dB(A)
• Detachable Bottom Cover
• Easy & Quick Repair Motor
Whispering Air Wi-Fi control Eco-pilot Sensors 3M Purify Filter Easy Installation
• 2-way Piping Design

Dawn
A+++/A+++ Outdoor Remote Controller USB Wi-Fi Wired Controller

Whispering Air Quiet to 15dB(A) AS20S2SD1FA AS25S2SD1FA AS35S2SD1FA AS42S2SD1FA

Indoor AS20S2SD1FA AS25S2SD1FA AS35S2SD1FA AS42S2SD1FA


Model
Outdoor 1U25S2PJ1FA 1U35S2PJ1FA
Nominal (Min.~Max.) Btu/h 8870(3410-11940) 11940(4090-14670)
Cooling Capacity
Nominal (Min.~Max.) kW 2.6(1.0-3.5) 3.5(1.2-4.3)
Energy efficiency(average climate) SEER/EER Energy Saving 8.50/4.00 8.50/4.00
Energy class - Cooling A+++ A+++
Cooling Pdesign capacity(35°C) kW 2.6 3.5
Power input - Cooling Nominal (Min.~Max.) kW 0.65(0.3-1.2) 0.875(0.37-1.3)
Annual energy consumption - Cooling kWh/a 107 144
Nominal (Min.~Max.) Btu/h 10920(3750-18430) 14330(4440-19790)

15
dB(A) Whispering Air Heating Capacity
Heating @ -7℃
Nominal (Min.~Max.)
Btu/h
kW Multi
8020
3.2(1.1-5.4)
10070
4.2(1.3-5.8) Multi
Heating @ -7℃ kW Connection 2.35 2.95 Connection
SCOP/COP(Average climate) Energy Saving Only 5.10/4.00 4.60/4.00 Only
Optimize the noise control technology, such as the compressor 20dB(A) Energy efficiency
SCOP(Warm/Cold climate) 6.25/- 5.60/- (except 1by2)
frequency adjustment, fan speed control and air flue design
decreasing the noise level even lowest to 15dB(A) with the
specialized QUIET setting. (refer to 9k)
15
dB(A)
Energy class - Heating
Heating Pdesign capacity (-10°C)
Power input - Heating
Average/warm/cold

Nominal (Min.~Max.)
kW
kW
A+++/A+++/-
2.6
0.80(0.48-1.60)
A++/A+++/-
3.2
1.05(0.55-1.80)
Annual energy consumption - Heating kWh/a 716 973
Operating limits (cooling) Min.~Max. °C 21-35ºC(in)/-10-43ºC(out) 21-35ºC(in)/-10-43ºC(out)
Operating limits (heating) Min.~Max. °C 10-27ºC(in)/-15-24ºC(out) 10-27ºC(in)/-15-24ºC(out)
Power supply Ph/V/Hz 1/230/50 1/230/50
Power supply (position) outdoor outdoor
40H FCL (set) *just for reference 174 174
Indoor
Net dimension W/D/H mm 980/212/318 980/212/318 980/212/318 980/212/318
Package dimension W/D/H mm 1059/289/407 1059/289/407 1059/289/407 1059/289/407

Wi-Fi Control
Net/Shipping weight kg - 11.8/15.2 11.8/15.2 -
Air flow(cooling/heating) Max. m³/h - 650 700 -
Cooling (Hi) dB - 54 56 -
Sound power level
Heating (Hi) dB - 54 56 -
Control your air conditioning system with smart phone or tablet, Sound pressure level
Cooling (Hi/Mid/Lo/So) dB(A) - 34/29/25/15 35/30/26/16 -

which can connect internet. Heating (Hi/Mid/Lo/So) dB(A) - 34/29/25/15 35/30/26/16 -


Moisture removal 10¯³m³/h - 1.2 1.6 -
Outdoor
Compressor Hitachi Hitachi
Net dimension W/D/H mm 820/338/614 820/338/614
Package dimension W/D/H mm 963/413/685 963/413/685
Net/Shipping weight kg 37.4/41.1 37.4/41.1
Air flow(cooling/heating) Max. m /h3
2100 2100
Sound power level Hi dB 61 62

Eco-pilot Sensors
Sound pressure level Hi dB(A) Multi 45 46 Multi
Running current Max. A Connection 7.1 8.0 Connection
Refrigerant type R410A/R32 Only R32 R32 Only
Refrigerant charge R410A/R32 g 950 950
Ecopilot detects and reduces energy waste in all the right ways. Liquid side diameter mm / inch 6.35 6.35
Gas side diameter mm / inch 9.52 9.52
Intelligent sensors detect potential waste of energy by using the
Max. pipe length/height m 15/10 15/10
Refrigerant pipe
human activity sensor and sunlight sensor. It is able to monitor Max. pipe length without
human location, movements, absence and sunlight intensity. It then m 7 7
additional charge
automatically adjusts cooling power to save energy efficiently with 6 5 4 3 2 1 additional charge g/m 20 20

uninterrupted heating and cooling comfort and convenience. Rating Conditions: Cooling Indoor 27ºC DB / 19ºC WB. Cooling Outdoor 35ºC DB / 24ºC WB. Heating Indoor 20ºC DB. Heating Outdoor 7ºC DB / 6ºC WB.(DB: Dry Bulb; WB: Wet Bulb)
For detailed information about ErP, please visit our page http://www.haier.com/ecodesign.

43 44
Key Features Features

• 3D Airflow
• Easy Support Clip
15
dB(A)
• Detachable Bottom Cover
• Easy & Quick Repair Motor
Whispering Air Wi-Fi control Eco-pilot Sensors 3M Purify Filter Easy Installation
• 2-way Piping Design

Dawn
A+++/A+++ Outdoor Remote Controller USB Wi-Fi Wired Controller

Whispering Air Quiet to 15dB(A) AS20S2SD1FA AS25S2SD1FA AS35S2SD1FA AS42S2SD1FA

Indoor AS20S2SD1FA AS25S2SD1FA AS35S2SD1FA AS42S2SD1FA


Model
Outdoor 1U25S2PJ1FA 1U35S2PJ1FA
Nominal (Min.~Max.) Btu/h 8870(3410-11940) 11940(4090-14670)
Cooling Capacity
Nominal (Min.~Max.) kW 2.6(1.0-3.5) 3.5(1.2-4.3)
Energy efficiency(average climate) SEER/EER Energy Saving 8.50/4.00 8.50/4.00
Energy class - Cooling A+++ A+++
Cooling Pdesign capacity(35°C) kW 2.6 3.5
Power input - Cooling Nominal (Min.~Max.) kW 0.65(0.3-1.2) 0.875(0.37-1.3)
Annual energy consumption - Cooling kWh/a 107 144
Nominal (Min.~Max.) Btu/h 10920(3750-18430) 14330(4440-19790)

15
dB(A) Whispering Air Heating Capacity
Heating @ -7℃
Nominal (Min.~Max.)
Btu/h
kW Multi
8020
3.2(1.1-5.4)
10070
4.2(1.3-5.8) Multi
Heating @ -7℃ kW Connection 2.35 2.95 Connection
SCOP/COP(Average climate) Energy Saving Only 5.10/4.00 4.60/4.00 Only
Optimize the noise control technology, such as the compressor 20dB(A) Energy efficiency
SCOP(Warm/Cold climate) 6.25/- 5.60/- (except 1by2)
frequency adjustment, fan speed control and air flue design
decreasing the noise level even lowest to 15dB(A) with the
specialized QUIET setting. (refer to 9k)
15
dB(A)
Energy class - Heating
Heating Pdesign capacity (-10°C)
Power input - Heating
Average/warm/cold

Nominal (Min.~Max.)
kW
kW
A+++/A+++/-
2.6
0.80(0.48-1.60)
A++/A+++/-
3.2
1.05(0.55-1.80)
Annual energy consumption - Heating kWh/a 716 973
Operating limits (cooling) Min.~Max. °C 21-35ºC(in)/-10-43ºC(out) 21-35ºC(in)/-10-43ºC(out)
Operating limits (heating) Min.~Max. °C 10-27ºC(in)/-15-24ºC(out) 10-27ºC(in)/-15-24ºC(out)
Power supply Ph/V/Hz 1/230/50 1/230/50
Power supply (position) outdoor outdoor
40H FCL (set) *just for reference 174 174
Indoor
Net dimension W/D/H mm 980/212/318 980/212/318 980/212/318 980/212/318
Package dimension W/D/H mm 1059/289/407 1059/289/407 1059/289/407 1059/289/407

Wi-Fi Control
Net/Shipping weight kg - 11.8/15.2 11.8/15.2 -
Air flow(cooling/heating) Max. m³/h - 650 700 -
Cooling (Hi) dB - 54 56 -
Sound power level
Heating (Hi) dB - 54 56 -
Control your air conditioning system with smart phone or tablet, Sound pressure level
Cooling (Hi/Mid/Lo/So) dB(A) - 34/29/25/15 35/30/26/16 -

which can connect internet. Heating (Hi/Mid/Lo/So) dB(A) - 34/29/25/15 35/30/26/16 -


Moisture removal 10¯³m³/h - 1.2 1.6 -
Outdoor
Compressor Hitachi Hitachi
Net dimension W/D/H mm 820/338/614 820/338/614
Package dimension W/D/H mm 963/413/685 963/413/685
Net/Shipping weight kg 37.4/41.1 37.4/41.1
Air flow(cooling/heating) Max. m /h3
2100 2100
Sound power level Hi dB 61 62

Eco-pilot Sensors
Sound pressure level Hi dB(A) Multi 45 46 Multi
Running current Max. A Connection 7.1 8.0 Connection
Refrigerant type R410A/R32 Only R32 R32 Only
Refrigerant charge R410A/R32 g 950 950
Ecopilot detects and reduces energy waste in all the right ways. Liquid side diameter mm / inch 6.35 6.35
Gas side diameter mm / inch 9.52 9.52
Intelligent sensors detect potential waste of energy by using the
Max. pipe length/height m 15/10 15/10
Refrigerant pipe
human activity sensor and sunlight sensor. It is able to monitor Max. pipe length without
human location, movements, absence and sunlight intensity. It then m 7 7
additional charge
automatically adjusts cooling power to save energy efficiently with 6 5 4 3 2 1 additional charge g/m 20 20

uninterrupted heating and cooling comfort and convenience. Rating Conditions: Cooling Indoor 27ºC DB / 19ºC WB. Cooling Outdoor 35ºC DB / 24ºC WB. Heating Indoor 20ºC DB. Heating Outdoor 7ºC DB / 6ºC WB.(DB: Dry Bulb; WB: Wet Bulb)
For detailed information about ErP, please visit our page http://www.haier.com/ecodesign.

43 44
Key Features Features

• 3D Airflow
• Easy Support Clip
16
dB(A)
• Detachable Bottom Cover
• Easy & Quick Repair Motor
Whispering Air Eco Sensor Easy Installation Wi-Fi control 3M Purify Filter
(Optional) (Optional) • 2-way Piping Design

Flexis
A+++/A++ Outdoor Remote Controller USB Wi-Fi Wired Controller
AS20S2SF1FA AS25S2SF1FA AS35S2SF1FA AS50S2SF1FA
Whispering Air Quiet to 16dB(A) AS71S2SF1FA

Indoor AS20S2SF1FA AS25S2SF1FA AS35S2SF1FA AS50S2SF1FA AS71S2SF1FA


Model
Outdoor 1U25S2SM1FA 1U35S2SM1FA 1U50S2SJ2FA 1UH071N1ERG
Nominal (Min.~Max.) Btu/h 8870(2730-10920) 11940(3410-13650) 17740(4770-23890) 23890(7510-25600)
Cooling Capacity
Nominal (Min.~Max.) kW 2.6(0.8-3.2) 3.5(1.0-4.0) 5.2(1.4-7.0) 7.0(2.2-7.5)
Energy efficiency(average climate) SEER/EER Energy Saving 8.50/4.00 8.5/4.00 7.2/3.68 7.1/3.23
Energy class - Cooling A+++ A+++ A++ A++
Cooling Pdesign capacity(35°C) kW 2.6 3.5 5.2 7
Power input - Cooling Nominal (Min.~Max.) kW 0.65(0.2-1.5) 0.88(0.3-1.5) 1.41(0.5-2.0) 2.18(0.7-2.9)
Annual energy consumption - Cooling kWh/a 107 144 246 345

Whispering Air
Nominal (Min.~Max.) 10920(2730-14330) 14330(3410-17740) 20470(4770-23540) 27300(8190-29000)
16
Btu/h
dB(A) Heating @ -7ºC Btu/h 7200 8395 13790 16790
Heating Capacity
Nominal (Min.~Max.) kW Multi 3.2(0.8-4.2) 4.2(1.0-5.2) 6.0(1.4-6.9) 8.0(2.4-8.5)
Heating @ -7ºC kW Connection 2.11 2.46 4.04 4.92
Optimize the noise control technology, such as the compressor 20dB(A) SCOP/COP(Average climate) Energy Saving Only 4.60/4.00 4.60/3.81 4.60/4.00 4.00/3.71

16
Energy efficiency
SCOP(Warm/Cold climate)
frequency adjustment, fan speed control and air flue design 5.50/- 5.50/- 5.60/- 5.40/-
Energy class - Heating Average/warm/cold A++/A+++/- A++/A+++/- A++/A+++/- A+/A+++/-
decreasing the noise level even lowest to 16dB(A) with the Heating Pdesign capacity (-10°C) kW 2.4 2.8 4.6 5.6
specialized QUIET setting. (refer to 9k) dB(A) Power input - Heating Nominal (Min.~Max.) kW 0.8(0.3-1.6) 1.1(0.5-1.6) 1.61(0.52-2.35) 2.156(0.7-2.9)
Annual energy consumption - Heating kWh/a 730 856 1399 1959
Operating limits (cooling) Min.~Max. °C 21-35ºC(in)/-10-43ºC(out) 21-35ºC(in)/-10-43ºC(out) 21-35ºC(in)/-10-43ºC(out) 21-35ºC(in)/-10-43ºC(out)
Operating limits (heating) Min.~Max. °C 10-27ºC(in)/-15-24ºC(out) 10-27ºC(in)/-15-24ºC(out) 10-27ºC(in)/-15-24ºC(out) 10-27ºC(in)/-15-24ºC(out)
Power supply Ph/V/Hz 1/230/50 1/230/50 1/230/50 1/230/50
Power supply (position) outdoor outdoor outdoor outdoor
40H FCL (set) *just for reference 204 204 162 132
Indoor

Eco Sensor Net dimension


Package dimension
W/D/H
W/D/H
mm
mm
866/196/301
952/283/389
866/196/301
952/283/389
866/196/301
952/283/389
1009/223/327
1085/296/405
1126/230/337
1187/301/417
Net/Shipping weight kg - 9.5/12 9.5/12 11.9/14.9 15.2/18.2
Air flow(cooling/heating) Max. m³/h - 600 650 900 1100
Double human sense integrated module, double area detection , Cooling (Hi) dB - 53 55 57 60
Sound power level
detection angle 120°(horizontal), detection distance within 8m. Heating (Hi) dB - 53 55 57 60
Cooling (Hi/Mid/Lo/So) dB(A) - 38/32/25/16 39/33/26/17 41/37/33/28 47/43/37/30
Sound pressure level
Heating (Hi/Mid/Lo/So) dB(A) - 38/32/25/19 39/33/26/20 41/37/33/28 47/43/37/30
Moisture removal 10¯³m³/h - 1.2 1.6 2 2.8
2 1 Outdoor
Compressor Panasonic Hitachi Mitsubishi Mitsubishi
Net dimension W/D/H mm 800/280/550 800/280/550 820/338/614 860/308/730
Package dimension W/D/H mm 954/409/625 954/409/625 963/413/685 995/420/815
Net/Shipping weight kg 29/31.5 31.5/34 37.8/41.5 49/52
Air flow(cooling/heating) Max. m ³/h 1600 1800 2500 3000
Sound power level Hi dB 59 61 63 70

Easy Installation Sound pressure level


Running current
Hi
Max.
dB(A)
A
Multi
Connection
47
7.2
48
7.2
51
10.9
57
13
Refrigerant type R410A/R32 Only R32 R32 R32 R32
Refrigerant charge R410A/R32 g 650 940 950 1300
Advanced technology of component, system and control to make Liquid side diameter mm / inch 6.35 6.35 6.35 9.52
comfort easier for professional customers/users. Gas side diameter mm / inch 9.52 9.52 12.7 15.88
Max. pipe length/height m 15/10 15/10 25/15 25/15
Refrigerant pipe
Max. pipe length without
m 7 7 7 7
additional charge
additional charge g/m 20 20 20 50

Rating Conditions: Cooling Indoor 27ºC DB / 19ºC WB. Cooling Outdoor 35ºC DB / 24ºC WB. Heating Indoor 20ºC DB. Heating Outdoor 7ºC DB / 6ºC WB.(DB: Dry Bulb; WB: Wet Bulb)
For detailed information about ErP, please visit our page http://www.haier.com/ecodesign.

45 46
Key Features Features

• 3D Airflow
• Easy Support Clip
16
dB(A)
• Detachable Bottom Cover
• Easy & Quick Repair Motor
Whispering Air Eco Sensor Easy Installation Wi-Fi control 3M Purify Filter
(Optional) (Optional) • 2-way Piping Design

Flexis
A+++/A++ Outdoor Remote Controller USB Wi-Fi Wired Controller
AS20S2SF1FA AS25S2SF1FA AS35S2SF1FA AS50S2SF1FA
Whispering Air Quiet to 16dB(A) AS71S2SF1FA

Indoor AS20S2SF1FA AS25S2SF1FA AS35S2SF1FA AS50S2SF1FA AS71S2SF1FA


Model
Outdoor 1U25S2SM1FA 1U35S2SM1FA 1U50S2SJ2FA
Nominal (Min.~Max.) Btu/h 8870(2730-10920) 11940(3410-13650) 17740(4770-23890) 23890(7510-25600)
Cooling Capacity
Nominal (Min.~Max.) kW 2.6(0.8-3.2) 3.5(1.0-4.0) 5.2(1.4-7.0) 7.0(2.2-7.5)
Energy efficiency(average climate) SEER/EER Energy Saving 8.50/4.00 8.5/4.00 7.2/3.68 7.1/3.23
Energy class - Cooling A+++ A+++ A++ A++
Cooling Pdesign capacity(35°C) kW 2.6 3.5 5.2 7
Power input - Cooling Nominal (Min.~Max.) kW 0.65(0.2-1.5) 0.88(0.3-1.5) 1.41(0.5-2.0) 2.18(0.7-2.9)
Annual energy consumption - Cooling kWh/a 107 144 246 345

Whispering Air
Nominal (Min.~Max.) 10920(2730-14330) 14330(3410-17740) 20470(4770-23540) 27300(8190-29000)
16
Btu/h
dB(A) Heating @ -7ºC Btu/h 7200 8395 13790 16790
Heating Capacity
Nominal (Min.~Max.) kW Multi 3.2(0.8-4.2) 4.2(1.0-5.2) 6.0(1.4-6.9) 8.0(2.4-8.5)
Heating @ -7ºC kW Connection 2.11 2.46 4.04 4.92
Optimize the noise control technology, such as the compressor 20dB(A) SCOP/COP(Average climate) Energy Saving Only 4.60/4.00 4.60/3.81 4.60/4.00 4.00/3.71

16
Energy efficiency
SCOP(Warm/Cold climate)
frequency adjustment, fan speed control and air flue design 5.50/- 5.50/- 5.60/- 5.40/-
Energy class - Heating Average/warm/cold A++/A+++/- A++/A+++/- A++/A+++/- A+/A+++/-
decreasing the noise level even lowest to 16dB(A) with the Heating Pdesign capacity (-10°C) kW 2.4 2.8 4.6 5.6
specialized QUIET setting. (refer to 9k) dB(A) Power input - Heating Nominal (Min.~Max.) kW 0.8(0.3-1.6) 1.1(0.5-1.6) 1.61(0.52-2.35) 2.156(0.7-2.9)
Annual energy consumption - Heating kWh/a 730 856 1399 1959
Operating limits (cooling) Min.~Max. °C 21-35ºC(in)/-10-43ºC(out) 21-35ºC(in)/-10-43ºC(out) 21-35ºC(in)/-10-43ºC(out) 21-35ºC(in)/-10-43ºC(out)
Operating limits (heating) Min.~Max. °C 10-27ºC(in)/-15-24ºC(out) 10-27ºC(in)/-15-24ºC(out) 10-27ºC(in)/-15-24ºC(out) 10-27ºC(in)/-15-24ºC(out)
Power supply Ph/V/Hz 1/230/50 1/230/50 1/230/50 1/230/50
Power supply (position) outdoor outdoor outdoor outdoor
40H FCL (set) *just for reference 204 204 162 132
Indoor

Eco Sensor Net dimension


Package dimension
W/D/H
W/D/H
mm
mm
866/196/301
952/283/389
866/196/301
952/283/389
866/196/301
952/283/389
1009/223/327
1085/296/405
1126/230/337
1187/301/417
Net/Shipping weight kg - 9.5/12 9.5/12 11.9/14.9 15.2/18.2
Air flow(cooling/heating) Max. m³/h - 600 650 900 1100
Double human sense integrated module, double area detection , Cooling (Hi) dB - 53 55 57 60
Sound power level
detection angle 120°(horizontal), detection distance within 8m. Heating (Hi) dB - 53 55 57 60
Cooling (Hi/Mid/Lo/So) dB(A) - 38/32/25/16 39/33/26/17 41/37/33/28 47/43/37/30
Sound pressure level
Heating (Hi/Mid/Lo/So) dB(A) - 38/32/25/19 39/33/26/20 41/37/33/28 47/43/37/30
Moisture removal 10¯³m³/h - 1.2 1.6 2 2.8
2 1 Outdoor
Compressor Panasonic Hitachi Mitsubishi Mitsubishi
Net dimension W/D/H mm 800/280/550 800/280/550 820/338/614 860/308/730
Package dimension W/D/H mm 954/409/625 954/409/625 963/413/685 995/420/815
Net/Shipping weight kg 29/31.5 31.5/34 37.8/41.5 49/52
Air flow(cooling/heating) Max. m ³/h 1600 1800 2500 3000
Sound power level Hi dB 59 61 63 70

Easy Installation Sound pressure level


Running current
Hi
Max.
dB(A)
A
Multi
Connection
47
7.2
48
7.2
51
10.9
57
13
Refrigerant type R410A/R32 Only R32 R32 R32 R32
Refrigerant charge R410A/R32 g 650 940 950 1300
Advanced technology of component, system and control to make Liquid side diameter mm / inch 6.35 6.35 6.35 9.52
comfort easier for professional customers/users. Gas side diameter mm / inch 9.52 9.52 12.7 15.88
Max. pipe length/height m 15/10 15/10 25/15 25/15
Refrigerant pipe
Max. pipe length without
m 7 7 7 7
additional charge
additional charge g/m 20 20 20 50

Rating Conditions: Cooling Indoor 27ºC DB / 19ºC WB. Cooling Outdoor 35ºC DB / 24ºC WB. Heating Indoor 20ºC DB. Heating Outdoor 7ºC DB / 6ºC WB.(DB: Dry Bulb; WB: Wet Bulb)
For detailed information about ErP, please visit our page http://www.haier.com/ecodesign.

45 46
Key Features Features

• Comfortable Sleep
• Easy Support Clip
19
dB(A)
• Easy & Quick Repair Motor
• 2-way Piping Design
Whispering Air Easy Installation Wi-Fi control 3D Airflow On-Off Card
(Optional)

Flair
A+++/A++ Outdoor Remote Controller USB Wi-Fi Wired Controller
AS20S2SF2FA AS25S2SF2FA AS35S2SF2FA AS50S2SF2FA
Whispering Air Quiet to 19dB(A) AS71S2SF2FA

Indoor AS20S2SF2FA AS25S2SF2FA AS35S2SF2FA AS50S2SF2FA AS71S2SF2FA


Model
Outdoor 1U25S2SM1FA 1U35S2SM1FA 1U50S2SJ2FA 1UH071N1ERG
Nominal (Min.~Max.) Btu/h 8870(2730-10920) 11940(3410-13650) 17740(4770-23890) 23890(7510-25600)
Cooling Capacity
Nominal (Min.~Max.) kW 2.6(0.8-3.2) 3.5(1.0-4.0) 5.2(1.4-7.0) 7.0(2.2-7.5)
Energy efficiency(average climate) SEER/EER Energy Saving 8.50/4.00 8.5/4.00 7.2/3.68 7.1/3.23
Energy class - Cooling A+++ A+++ A++ A++
Cooling Pdesign capacity(35°C) kW 2.6 3.5 5.2 7
Power input - Cooling Nominal (Min.~Max.) kW 0.65(0.2-1.5) 0.88(0.3-1.5) 1.41(0.5-2.0) 2.18(0.7-2.9)
Annual energy consumption - Cooling kWh/a 107 144 246 345

Whispering Air
Nominal (Min.~Max.) 10920(2730-14330) 14330(3410-17740) 20470(4770-23540) 27300(8190-29000)
19
Btu/h
dB(A) Heating @ -7ºC Btu/h 7200 8395 13790 16790
Heating Capacity
Nominal (Min.~Max.) kW Multi 3.2(0.8-4.2) 4.2(1.0-5.2) 6.0(1.4-6.9) 8.0(2.4-8.5)
Heating @ -7ºC kW Connection 2.11 2.46 4.04 4.92

19
Optimize the noise control technology, such as the compressor 20dB(A)
Energy efficiency
SCOP/COP(Average climate) Energy Saving Only 4.60/4.00 4.60/3.81 4.60/4.00 4.00/3.71
SCOP(Warm/Cold climate) 5.50/- 5.50/- 5.60/- 5.40/-
frequency adjustment, fan speed control and air flue design
Energy class - Heating Average/warm/cold A++/A+++/- A++/A+++/- A++/A+++/- A+/A+++/-
decreasing the noise level even lowest to 19dB(A) with the dB(A) Heating Pdesign capacity (-10°C) kW 2.4 2.8 4.6 5.6
specialized QUIET setting. (refer to 9k) Power input - Heating Nominal (Min.~Max.) kW 0.8(0.3-1.6) 1.1(0.5-1.6) 1.61(0.52-2.35) 2.156(0.7-2.9)
Annual energy consumption - Heating kWh/a 730 856 1399 1959
Operating limits (cooling) Min.~Max. °C 21-35ºC(in)/-10-43ºC(out) 21-35ºC(in)/-10-43ºC(out) 21-35ºC(in)/-10-43ºC(out) 21-35ºC(in)/-10-43ºC(out)
Operating limits (heating) Min.~Max. °C 10-27ºC(in)/-15-24ºC(out) 10-27ºC(in)/-15-24ºC(out) 10-27ºC(in)/-15-24ºC(out) 10-27ºC(in)/-15-24ºC(out)
Power supply Ph/V/Hz 1/230/50 1/230/50 1/230/50 1/230/50
Power supply (position) outdoor outdoor outdoor outdoor
40H FCL (set) *just for reference 204 204 162 132
Indoor

Easy Installation Net dimension


Package dimension
W/D/H
W/D/H
mm
mm
866/196/301
952/283/389
870/196/301
952/283/389
870/196/301
952/283/389
1009/223/327
1085/296/405
1126/230/337
1187/301/417
Net/Shipping weight kg - 9.5/12 9.5/12 11.9/14.9 15.2/18.2
Air flow(cooling/heating) Max. m³/h - 600 650 900 1100
Advanced technology of component, system and control to make Cooling (Hi) dB 53 55 57 60
-
comfort easier for professional customers/users. Sound power level
Heating (Hi) dB - 53 55 57 60
Cooling (Hi/Mid/Lo/So) dB(A) - 38/32/25/19 39/33/26/22 41/37/33/31 47/43/37/33
Sound pressure level
Heating (Hi/Mid/Lo/So) dB(A) - 38/32/25/19 39/33/26/22 41/37/33/31 47/43/37/33
Moisture removal 10¯³m³/h - 1.2 1.6 2 2.8
Outdoor
Compressor Panasonic Hitachi Mitsubishi Mitsubishi
Net dimension W/D/H mm 800/280/550 800/280/550 820/338/614 860/308/730
Package dimension W/D/H mm 954/409/625 954/409/625 963/413/685 995/420/815
Net/Shipping weight kg 29/31.5 31.5/34 37.8/41.5 49/52
Air flow(cooling/heating) Max. m³/h 1600 1800 2500 3000
Sound power level Hi dB 59 61 63 70
Sound pressure level Hi dB(A) Multi 47 48 51 57

Wi-Fi Control (Optional)


Running current Max. A Connection 7.2 7.2 10.9 13
Refrigerant type R410A/R32 Only R32 R32 R32 R32
Refrigerant charge R410A/R32 g 650 940 950 1300
Liquid side diameter mm / inch 6.35 6.35 6.35 9.52

Control your air conditioning system with smart phone or tablet, Gas side diameter mm / inch 9.52 9.52 12.7 15.88
Max. pipe length/height m 15/10 15/10 25/15 25/15
which can connect internet. Refrigerant pipe
Max. pipe length without
m 7 7 7 7
additional charge
additional charge g/m 20 20 20 50

Rating Conditions: Cooling Indoor 27ºC DB / 19ºC WB. Cooling Outdoor 35ºC DB / 24ºC WB. Heating Indoor 20ºC DB. Heating Outdoor 7ºC DB / 6ºC WB.(DB: Dry Bulb; WB: Wet Bulb)
For detailed information about ERP, please visit our page http://www.haier.com/ecodesign.

47 48
Key Features Features

• Comfortable Sleep
• Easy Support Clip
19
dB(A)
• Easy & Quick Repair Motor
• 2-way Piping Design
Whispering Air Easy Installation Wi-Fi control 3D Airflow On-Off Card
(Optional)

Flare
A+++/A++ Outdoor Remote Controller USB Wi-Fi Wired Controller
AS20S2SF2FA AS25S2SF2FA AS35S2SF2FA AS50S2SF2FA
Whispering Air Quiet to 19dB(A) AS71S2SF2FA

Indoor AS20S2SF2FA AS25S2SF2FA AS35S2SF2FA AS50S2SF2FA AS71S2SF2FA


Model
Outdoor 1U25S2SM1FA 1U35S2SM1FA 1U50S2SJ2FA
Nominal (Min.~Max.) Btu/h 8870(2730-10920) 11940(3410-13650) 17740(4770-23890) 23890(7510-25600)
Cooling Capacity
Nominal (Min.~Max.) kW 2.6(0.8-3.2) 3.5(1.0-4.0) 5.2(1.4-7.0) 7.0(2.2-7.5)
Energy efficiency(average climate) SEER/EER Energy Saving 8.50/4.00 8.5/4.00 7.2/3.68 7.1/3.23
Energy class - Cooling A+++ A+++ A++ A++
Cooling Pdesign capacity(35°C) kW 2.6 3.5 5.2 7
Power input - Cooling Nominal (Min.~Max.) kW 0.65(0.2-1.5) 0.88(0.3-1.5) 1.41(0.5-2.0) 2.18(0.7-2.9)
Annual energy consumption - Cooling kWh/a 107 144 246 345

Whispering Air
Nominal (Min.~Max.) 10920(2730-14330) 14330(3410-17740) 20470(4770-23540) 27300(8190-29000)
19
Btu/h
dB(A) Heating @ -7ºC Btu/h 7200 8395 13790 16790
Heating Capacity
Nominal (Min.~Max.) kW Multi 3.2(0.8-4.2) 4.2(1.0-5.2) 6.0(1.4-6.9) 8.0(2.4-8.5)
Heating @ -7ºC kW Connection 2.11 2.46 4.04 4.92

19
Optimize the noise control technology, such as the compressor 20dB(A)
Energy efficiency
SCOP/COP(Average climate) Energy Saving Only 4.60/4.00 4.60/3.81 4.60/4.00 4.00/3.71
SCOP(Warm/Cold climate) 5.50/- 5.50/- 5.60/- 5.40/-
frequency adjustment, fan speed control and air flue design
Energy class - Heating Average/warm/cold A++/A+++/- A++/A+++/- A++/A+++/- A+/A+++/-
decreasing the noise level even lowest to 19dB(A) with the dB(A) Heating Pdesign capacity (-10°C) kW 2.4 2.8 4.6 5.6
specialized QUIET setting. (refer to 9k) Power input - Heating Nominal (Min.~Max.) kW 0.8(0.3-1.6) 1.1(0.5-1.6) 1.61(0.52-2.35) 2.156(0.7-2.9)
Annual energy consumption - Heating kWh/a 730 856 1399 1959
Operating limits (cooling) Min.~Max. °C 21-35ºC(in)/-10-43ºC(out) 21-35ºC(in)/-10-43ºC(out) 21-35ºC(in)/-10-43ºC(out) 21-35ºC(in)/-10-43ºC(out)
Operating limits (heating) Min.~Max. °C 10-27ºC(in)/-15-24ºC(out) 10-27ºC(in)/-15-24ºC(out) 10-27ºC(in)/-15-24ºC(out) 10-27ºC(in)/-15-24ºC(out)
Power supply Ph/V/Hz 1/230/50 1/230/50 1/230/50 1/230/50
Power supply (position) outdoor outdoor outdoor outdoor
40H FCL (set) *just for reference 204 204 162 132
Indoor

Easy Installation Net dimension


Package dimension
W/D/H
W/D/H
mm
mm
866/196/301
952/283/389
870/196/301
952/283/389
870/196/301
952/283/389
1009/223/327
1085/296/405
1126/230/337
1187/301/417
Net/Shipping weight kg - 9.5/12 9.5/12 11.9/14.9 15.2/18.2
Air flow(cooling/heating) Max. m³/h - 600 650 900 1100
Advanced technology of component, system and control to make Cooling (Hi) dB 53 55 57 60
-
comfort easier for professional customers/users. Sound power level
Heating (Hi) dB - 53 55 57 60
Cooling (Hi/Mid/Lo/So) dB(A) - 38/32/25/19 39/33/26/22 41/37/33/31 47/43/37/33
Sound pressure level
Heating (Hi/Mid/Lo/So) dB(A) - 38/32/25/19 39/33/26/22 41/37/33/31 47/43/37/33
Moisture removal 10¯³m³/h - 1.2 1.6 2 2.8
Outdoor
Compressor Panasonic Hitachi Mitsubishi Mitsubishi
Net dimension W/D/H mm 800/280/550 800/280/550 820/338/614 860/308/730
Package dimension W/D/H mm 954/409/625 954/409/625 963/413/685 995/420/815
Net/Shipping weight kg 29/31.5 31.5/34 37.8/41.5 49/52
Air flow(cooling/heating) Max. m³ /h 1600 1800 2500 3000
Sound power level Hi dB 59 61 63 70
Sound pressure level Hi dB(A) Multi 47 48 51 57

Wi-Fi Control (Optional)


Running current Max. A Connection 7.2 7.2 10.9 13
Refrigerant type R410A/R32 Only R32 R32 R32 R32
Refrigerant charge R410A/R32 g 650 940 950 1300
Liquid side diameter mm / inch 6.35 6.35 6.35 9.52

Control your air conditioning system with smart phone or tablet, Gas side diameter mm / inch 9.52 9.52 12.7 15.88
Max. pipe length/height m 15/10 15/10 25/15 25/15
which can connect internet. Refrigerant pipe
Max. pipe length without
m 7 7 7 7
additional charge
additional charge g/m 20 20 20 50

Rating Conditions: Cooling Indoor 27ºC DB / 19ºC WB. Cooling Outdoor 35ºC DB / 24ºC WB. Heating Indoor 20ºC DB. Heating Outdoor 7ºC DB / 6ºC WB.(DB: Dry Bulb; WB: Wet Bulb)
For detailed information about ERP, please visit our page http://www.haier.com/ecodesign.

47 48
Key Features Features

• -15°C Heating
• Easy Support Clip
20
dB(A) • Easy & Quick Repair Motor
• 2-way Piping Design
Whispering Air Wi-Fi Control Intelligent Air Comfortable Sleep On-off Card
(Optional)

Tundra Green Outdoor Remote Controller USB Wi-Fi Wired Controller


A++/A+
AS25TABHRA AS35TABHRA AS50TDBHRA AS68TEBHRA
Whispering Air Quiet to 20dB(A)

Indoor AS25TABHRA AS35TABHRA AS50TDBHRA AS68TEBHRA


Model
Outdoor 1U25BEFFRA 1U35BEFFRA 1U50JEFFRA 1U68REFFRA
Nominal (Min.~Max.) Btu/h 8870(2730-11600) 12280(3410-14330) 17740(4430-23200) 23880(7500-29000)
Cooling Capacity
Nominal (Min.~Max.) kW 2.6(0.8-3.4) 3.6(1.0-4.2) 5.2(1.3-6.8) 7.0(2.2-8.5)
Energy Efficiency(average climate) SEER/EER Energy Saving 6.20/3.23 6.80/3.23 6.80/3.23 7.10/3.23
Energy Class - Cooling A++ A++ A++ A++
Cooling Pdesign Capacity(35°C) kW 2.6 3.6 5.2 7.0
Power Input - Cooling Nominal (Min.~Max.) kW 0.80(0.30-1.20) 1.11(0.30-1.60) 1.61(0.40-2.00) 2.16(0.70-2.90)
Annual Energy Consumption - Cooling kWh/a 147 186 268 350
Nominal (Min.~Max.) Btu/h 11600(3410-15690) 14330(3750-18420) 20470(4770-23540) 27640(8190-34120)
Heating @ -7ºC Btu/h 7510 9890 16040 17060
Heating Capacity
20 Whispering Air
Nominal (Min.~Max.) kW 3.4(1.0-4.6) 4.2(1.1-5.4) 6.0(1.4-6.9) 8.1(2.4-10.0)
dB(A) Heating @ -7ºC kW 2.2 2.9 4.7 5.0
SCOP/COP(Average climate) Energy Saving 4.00/3.71 4.00/3.71 4.00/3.71 4.00/3.71
20dB(A) Energy Efficiency

20
SCOP(Warm/Cold climate) 4.90/- 4.60/- 5.30/- 5.30/-
Optimize the noise control technology, such as the compressor Energy Class - Heating Average/warm/cold A+/A++/- A+/A+++/- A+/A+++/- A+/A+++/-

frequency adjustment, fan speed control and air flue design Heating Pdesign Capacity (-10°C) kW 2.4 3.2 5.2 5.6
Power Input - Heating Nominal (Min.~Max.) kW 0.91(0.30-1.50) 1.13(0.40-1.60) 1.61(0.52-2.35) 2.18(0.70-2.90)
decreasing the noise level even lowest to 20dB(A) with the dB(A)
Annual Energy Consumption - Heating kWh/a 839 1123 1819 1963
specialized QUIET setting. (refer to 9k) Operating limits (cooling) Min.~Max. ºC 21-35ºC(in)/-10-43ºC(out) 21-35ºC(in)/-10-43ºC(out) 21-35ºC(in)/-10-43ºC(out) 21-35ºC(in)/-10-43ºC(out)
Operating limits (heating) Min.~Max. ºC 10-27ºC(in)/-15-24ºC(out) 10-27ºC(in)/-15-24ºC(out) 10-27ºC(in)/-15-24ºC(out) 10-27ºC(in)/-15-24ºC(out)
Power Supply Ph/V/Hz 1/230/50 1/230/50 1/230/50 1/230/50
Power Supply (position) outdoor outdoor outdoor outdoor
40H FCL (set) *just for reference 230 230 158 125
Indoor
Net Dimension W/D/H mm 820/195/280 820/195/280 1008/225/318 1125/240/335
Package Dimension W/D/H mm 909/279/355 909/279/355 1085/329/403 1206/342/418

Intelligent Air Net/Shipping Weight


Air Flow(cooling/heating) Max.
kg
m³/h
8.8/11
500
8.8/11
550
11.6/14.4
1000
14/17.5
1200
Cooling (Hi) dB 52 54 57 60
Sound Power Level
Heating (Hi) dB 53 55 58 61
Airflow automatically upward when cooling or downward when Cooling (Hi/Mid/Lo/So) dB(A) 35/32/28/20 36/33/29/21 44/40/35/28 47/43/37/30
Sound Pressure Level
heating to spread air automatically throughout the large room Heating (Hi/Mid/Lo/So) dB(A) 36/33/29/21 37/34/30/22 45/41/36/29 48/44/38/31

while without blowing directly to human body. Moisture Removal 10¯³m³/h 1.2 1.6 2.0 2.8
Outdoor
Compressor Panasonic Mitsubishi Mitsubishi Mitsubishi
Net Dimension W/D/H mm 780/245/540 780/245/540 820/338/614 890/353/697
Package Dimension W/D/H mm 920/351/620 920/351/620 963/413/685 1046/460/780
Net/Shipping Weight kg 27/30 28/31 37.8/41.5 51/56
Air Flow(cooling/heating) Max. m³/h 1900 1900 2500 2900
Sound Power Level Hi dB 60/61 61/62 63/64 65/66
Sound Pressure Level Hi dB(A) 46/47 46/47 51/52 52/53
Running Current Max. A 6.7 7.1 10.6 13

Comfortable Sleep Refrigerant Type


Refrigerant Charge
R410A/R32
R410A/R32 g
R32
700
R32
720
R32
950
R32
1200
Liquid side diameter mm / inch 6.35 6.35 6.35 6.35
Gas side diameter mm / inch 12.7 9.52 12.7 12.7
The setting temperature and the indoor noise can be adjusted Max. pipe length/height m 15/10 15/10 25/15 25/15
Refrigerant Pipe
to a more comfortable level when you set the "sleep mode" Max. pipe length without additional charge m 7 7 7 7
during night sleep. additional charge g/m 20 20 20 20

Rating Conditions: Cooling Indoor 27ºC DB / 19ºC WB. Cooling Outdoor 35ºC DB / 24ºC WB. Heating Indoor 20ºC DB. Heating Outdoor 7ºC DB / 6ºC WB.(DB: Dry Bulb; WB: Wet Bulb)
For detailed information about ERP, please visit our page http://www.haier.com/ecodesign.

49 50
Key Features Features

• -15°C Heating
• Easy Support Clip
20
dB(A) • Easy & Quick Repair Motor
• 2-way Piping Design
Whispering Air Wi-Fi Control Intelligent Air Comfortable Sleep On-off Card
(Optional)

Tundra Green Outdoor Remote Controller USB Wi-Fi Wired Controller


A++/A+
AS25TABHRA AS35TABHRA AS50TDBHRA AS68TEBHRA
Whispering Air Quiet to 20dB(A)

Indoor AS25TABHRA AS35TABHRA AS50TDBHRA AS68TEBHRA


Model
Outdoor 1U25BEFFRA 1U35BEFFRA 1U50JEFFRA 1U68REFFRA
Nominal (Min.~Max.) Btu/h 8870(2730-11600) 12280(3410-14330) 17740(4430-23200) 23880(7500-29000)
Cooling Capacity
Nominal (Min.~Max.) kW 2.6(0.8-3.4) 3.6(1.0-4.2) 5.2(1.3-6.8) 7.0(2.2-8.5)
Energy Efficiency(average climate) SEER/EER Energy Saving 6.20/3.23 6.80/3.23 6.80/3.23 7.10/3.23
Energy Class - Cooling A++ A++ A++ A++
Cooling Pdesign Capacity(35°C) kW 2.6 3.6 5.2 7.0
Power Input - Cooling Nominal (Min.~Max.) kW 0.80(0.30-1.20) 1.11(0.30-1.60) 1.61(0.40-2.00) 2.16(0.70-2.90)
Annual Energy Consumption - Cooling kWh/a 147 186 268 350
Nominal (Min.~Max.) Btu/h 11600(3410-15690) 14330(3750-18420) 20470(4770-23540) 27640(8190-34120)
Heating @ -7ºC Btu/h 7510 9890 16040 17060
Heating Capacity
20 Whispering Air
Nominal (Min.~Max.) kW 3.4(1.0-4.6) 4.2(1.1-5.4) 6.0(1.4-6.9) 8.1(2.4-10.0)
dB(A) Heating @ -7ºC kW 2.2 2.9 4.7 5.0
SCOP/COP(Average climate) Energy Saving 4.00/3.71 4.00/3.71 4.00/3.71 4.00/3.71
20dB(A) Energy Efficiency

20
SCOP(Warm/Cold climate) 4.90/- 4.60/- 5.30/- 5.30/-
Optimize the noise control technology, such as the compressor Energy Class - Heating Average/warm/cold A+/A++/- A+/A+++/- A+/A+++/- A+/A+++/-

frequency adjustment, fan speed control and air flue design Heating Pdesign Capacity (-10°C) kW 2.4 3.2 5.2 5.6
Power Input - Heating Nominal (Min.~Max.) kW 0.91(0.30-1.50) 1.13(0.40-1.60) 1.61(0.52-2.35) 2.18(0.70-2.90)
decreasing the noise level even lowest to 20dB(A) with the dB(A)
Annual Energy Consumption - Heating kWh/a 839 1123 1819 1963
specialized QUIET setting. (refer to 9k) Operating limits (cooling) Min.~Max. ºC 21-35ºC(in)/-10-43ºC(out) 21-35ºC(in)/-10-43ºC(out) 21-35ºC(in)/-10-43ºC(out) 21-35ºC(in)/-10-43ºC(out)
Operating limits (heating) Min.~Max. ºC 10-27ºC(in)/-15-24ºC(out) 10-27ºC(in)/-15-24ºC(out) 10-27ºC(in)/-15-24ºC(out) 10-27ºC(in)/-15-24ºC(out)
Power Supply Ph/V/Hz 1/230/50 1/230/50 1/230/50 1/230/50
Power Supply (position) outdoor outdoor outdoor outdoor
40H FCL (set) *just for reference 230 230 158 125
Indoor
Net Dimension W/D/H mm 820/195/280 820/195/280 1008/225/318 1125/240/335
Package Dimension W/D/H mm 909/279/355 909/279/355 1085/329/403 1206/342/418

Intelligent Air Net/Shipping Weight


Air Flow(cooling/heating) Max.
kg
m³/h
8.8/11
500
8.8/11
550
11.6/14.4
1000
14/17.5
1200
Cooling (Hi) dB 52 54 57 60
Sound Power Level
Heating (Hi) dB 53 55 58 61
Airflow automatically upward when cooling or downward when Cooling (Hi/Mid/Lo/So) dB(A) 35/32/28/20 36/33/29/21 44/40/35/28 47/43/37/30
Sound Pressure Level
heating to spread air automatically throughout the large room Heating (Hi/Mid/Lo/So) dB(A) 36/33/29/21 37/34/30/22 45/41/36/29 48/44/38/31

while without blowing directly to human body. Moisture Removal 10¯³m³/h 1.2 1.6 2.0 2.8
Outdoor
Compressor Panasonic Mitsubishi Mitsubishi Mitsubishi
Net Dimension W/D/H mm 780/245/540 780/245/540 820/338/614 890/353/697
Package Dimension W/D/H mm 920/351/620 920/351/620 963/413/685 1046/460/780
Net/Shipping Weight kg 27/30 28/31 37.8/41.5 51/56
Air Flow(cooling/heating) Max. m³/h 1900 1900 2500 2900
Sound Power Level Hi dB 60/61 61/62 63/64 65/66
Sound Pressure Level Hi dB(A) 46/47 46/47 51/52 52/53
Running Current Max. A 6.7 7.1 10.6 13

Comfortable Sleep Refrigerant Type


Refrigerant Charge
R410A/R32
R410A/R32 g
R32
700
R32
720
R32
950
R32
1200
Liquid side diameter mm / inch 6.35 6.35 6.35 6.35
Gas side diameter mm / inch 12.7 9.52 12.7 12.7
The setting temperature and the indoor noise can be adjusted Max. pipe length/height m 15/10 15/10 25/15 25/15
Refrigerant Pipe
to a more comfortable level when you set the "sleep mode" Max. pipe length without additional charge m 7 7 7 7
during night sleep. additional charge g/m 20 20 20 20

Rating Conditions: Cooling Indoor 27ºC DB / 19ºC WB. Cooling Outdoor 35ºC DB / 24ºC WB. Heating Indoor 20ºC DB. Heating Outdoor 7ºC DB / 6ºC WB.(DB: Dry Bulb; WB: Wet Bulb)
For detailed information about ERP, please visit our page http://www.haier.com/ecodesign.

49 50
Key Features Features

• -30°C Heating
• -10°C Cooling
19
dB(A) • 10°C Heating Maintenance
• Comfortable Sleep
Whispering Air Wi-Fi control Nano-aqua A-PAM 3D Airflow
Inverter Control
• Electrical Deicer

Crystal (For Nordic) Outdoor Remote Controller


A+++/A++
AS09CB2HRA AS12CB2HRA
Whispering Air Quiet to 19dB(A)

Indoor AS09CB2HRA AS12CB2HRA


Model
Outdoor 1U09JE7ERA 1U12JE7ERA
Nominal (Min.~Max.) Btu/h 8870(2730-11940) 12280(4430-14670)
Cooling Capacity
Nominal (Min.~Max.) kW 2.6(0.8-3.5) 3.6(1.3-4.3)
Energy efficiency(average climate) SEER/EER Energy Saving 8.50/4.00 7.40/3.80
Energy class - Cooling A+++ A++
Cooling Pdesign capacity(35°C) kW 2.6 3.6
Power input - Cooling Nominal (Min.~Max.) kW 0.65(0.19-0.95) 0.95(0.34-1.7)
Annual energy consumption - Cooling kWh/a 107 170
Nominal (Min.~Max.) Btu/h 10920(3410-20470) 14330(4780-22180)

19
dB(A) Whispering Air Heating Capacity
Heating @ -7°C
Nominal (Min.~Max.)
Btu/h
kW
7850
3.2(1.0-6.0)
9550
4.2(1.4-6.5)
Heating @ -7°C kW 2.3 2.8
SCOP/COP(Average climate) Energy Saving 4.60/4.00 4.40/3.50
Optimize the noise control technology, such as the compressor frequency adjustment, fan speed control and air flue Energy efficiency
SCOP(Warm/Cold climate) 5.50/3.60 5.30/3.40
design decreasing the noise level even lowest to 19dB(A) with the specialized QUIET setting. (refer to 9k) Energy class - Heating Average/warm/cold A++/A+++/A A+/A+++/A
Heating Pdesign capacity (-10°C) kW 2.6 3.2
Power input - Heating Nominal (Min.~Max.) kW 0.8(0.25-2.5) 1.2(0.4-2.7)
Annual energy consumption - Heating kWh/a 791 1020
Operating limits (cooling) Min.~Max. °C 21-35ºC(in)/-10-43ºC(out) 21-35ºC(in)/-10-43ºC(out)

Wi-Fi Control Operating limits (heating)


Power supply
Min.~Max.
Ph/V/Hz
°C 10-27ºC(in)/-30-24ºC(out)
1/230/50
10-27ºC(in)/-30-24ºC(out)
1/230/50
Power supply (position) outdoor outdoor
Control your air conditioning system with smart phone or tablet, which can connect internet. 40H FCL (set) *just for reference 155 155
Indoor
Net dimension W/D/H mm 907/198/309 907/198/309
Package dimension W/D/H mm 1015/290/413 1015/290/413
Net/Shipping weight kg 11.5/14.5 11.5/14.5
Air flow(cooling/heating) Max. m³/h 600 650

-30 °C Heating Sound power level


Cooling (Hi)
Heating (Hi)
dB
dB
52
52
54
54
Cooling (Hi/Mid/Lo/So) dB(A) 37/32/28/19 38/34/30/21
A special design for heating in cold winter even at -30°C ,with double-rotor compressor, DC motor ,optimized bottom Sound pressure level
Heating (Hi/Mid/Lo/So) dB(A) 37/32/28/19 38/34/30/21
plate ,and special automatic defrosting programme .etc . Moisture removal 10¯³m³/h 1.2 1.6
Outdoor
Compressor Mitsubishi Mitsubishi
Net dimension W/D/H mm 820/338/614 820/338/614
Package dimension W/D/H mm 992/415/770 992/415/770

Freeze-prevention Technology Net/Shipping weight


Air flow(cooling/heating) Max.
kg
m³/h
40/44
2200
40/44
2200
Sound power level Hi dB 63 64
Special designed outdoor unit bottom plate with freeze-prevention heater and rows of drain holes ,to prevent the Sound pressure level Hi dB(A) 52 53

system operation stoppage due to drain water freezing . Running current Max. A 11 12
Refrigerant type R410A/R32 R410A R410A
Refrigerant charge R410A/R32 g 1450 1460
Liquid side diameter mm / inch 6.35 6.35
Gas side diameter mm / inch 9.52 9.52

Compressor Preheating Technology Refrigerant pipe Max. pipe length/height


Max. pipe length without additional charge
m
m
15/10
7
15/10
7
additional charge g/m 20 20

Special designed compressor preheating programme,to ensure the preheating for normal start-up in extreme cold
climate for Nordic market . Rating Conditions: Cooling Indoor 27ºC DB / 19ºC WB. Cooling Outdoor 35ºC DB / 24ºC WB. Heating Indoor 20ºC DB. Heating Outdoor 7ºC DB / 6ºC WB.(DB: Dry Bulb; WB: Wet Bulb)
For detailed information about ErP, please visit our page http://www.haier.com/ecodesign.

51 52
Key Features Features

• -30°C Heating
• -10°C Cooling
19
dB(A) • 10°C Heating Maintenance
• Comfortable Sleep
Whispering Air Wi-Fi control Nano-aqua A-PAM 3D Airflow
Inverter Control
• Electrical Deicer

Crystal (For Nordic) Outdoor Remote Controller


A+++/A++
AS09CB2HRA AS12CB2HRA
Whispering Air Quiet to 19dB(A)

Indoor AS09CB2HRA AS12CB2HRA


Model
Outdoor 1U09JE7ERA 1U12JE7ERA
Nominal (Min.~Max.) Btu/h 8870(2730-11940) 12280(4430-14670)
Cooling Capacity
Nominal (Min.~Max.) kW 2.6(0.8-3.5) 3.6(1.3-4.3)
Energy efficiency(average climate) SEER/EER Energy Saving 8.50/4.00 7.40/3.80
Energy class - Cooling A+++ A++
Cooling Pdesign capacity(35°C) kW 2.6 3.6
Power input - Cooling Nominal (Min.~Max.) kW 0.65(0.19-0.95) 0.95(0.34-1.7)
Annual energy consumption - Cooling kWh/a 107 170
Nominal (Min.~Max.) Btu/h 10920(3410-20470) 14330(4780-22180)

19
dB(A) Whispering Air Heating Capacity
Heating @ -7°C
Nominal (Min.~Max.)
Btu/h
kW
7850
3.2(1.0-6.0)
9550
4.2(1.4-6.5)
Heating @ -7°C kW 2.3 2.8
SCOP/COP(Average climate) Energy Saving 4.60/4.00 4.40/3.50
Optimize the noise control technology, such as the compressor frequency adjustment, fan speed control and air flue Energy efficiency
SCOP(Warm/Cold climate) 5.50/3.60 5.30/3.40
design decreasing the noise level even lowest to 19dB(A) with the specialized QUIET setting. (refer to 9k) Energy class - Heating Average/warm/cold A++/A+++/A A+/A+++/A
Heating Pdesign capacity (-10°C) kW 2.6 3.2
Power input - Heating Nominal (Min.~Max.) kW 0.8(0.25-2.5) 1.2(0.4-2.7)
Annual energy consumption - Heating kWh/a 791 1020
Operating limits (cooling) Min.~Max. °C 21-35ºC(in)/-10-43ºC(out) 21-35ºC(in)/-10-43ºC(out)

Wi-Fi Control Operating limits (heating)


Power supply
Min.~Max.
Ph/V/Hz
°C 10-27ºC(in)/-30-24ºC(out)
1/230/50
10-27ºC(in)/-30-24ºC(out)
1/230/50
Power supply (position) outdoor outdoor
Control your air conditioning system with smart phone or tablet, which can connect internet. 40H FCL (set) *just for reference 155 155
Indoor
Net dimension W/D/H mm 907/198/309 907/198/309
Package dimension W/D/H mm 1015/290/413 1015/290/413
Net/Shipping weight kg 11.5/14.5 11.5/14.5
Air flow(cooling/heating) Max. m³/h 600 650

-30 °C Heating Sound power level


Cooling (Hi)
Heating (Hi)
dB
dB
52
52
54
54
Cooling (Hi/Mid/Lo/So) dB(A) 37/32/28/19 38/34/30/21
A special design for heating in cold winter even at -30°C ,with double-rotor compressor, DC motor ,optimized bottom Sound pressure level
Heating (Hi/Mid/Lo/So) dB(A) 37/32/28/19 38/34/30/21
plate ,and special automatic defrosting programme .etc . Moisture removal 10¯³m³/h 1.2 1.6
Outdoor
Compressor Mitsubishi Mitsubishi
Net dimension W/D/H mm 820/338/614 820/338/614
Package dimension W/D/H mm 992/415/770 992/415/770

Freeze-prevention Technology Net/Shipping weight


Air flow(cooling/heating) Max.
kg
m³/h
40/44
2200
40/44
2200
Sound power level Hi dB 63 64
Special designed outdoor unit bottom plate with freeze-prevention heater and rows of drain holes ,to prevent the Sound pressure level Hi dB(A) 52 53

system operation stoppage due to drain water freezing . Running current Max. A 11 12
Refrigerant type R410A/R32 R410A R410A
Refrigerant charge R410A/R32 g 1450 1460
Liquid side diameter mm / inch 6.35 6.35
Gas side diameter mm / inch 9.52 9.52

Compressor Preheating Technology Refrigerant pipe Max. pipe length/height


Max. pipe length without additional charge
m
m
15/10
7
15/10
7
additional charge g/m 20 20

Special designed compressor preheating programme,to ensure the preheating for normal start-up in extreme cold
climate for Nordic market . Rating Conditions: Cooling Indoor 27ºC DB / 19ºC WB. Cooling Outdoor 35ºC DB / 24ºC WB. Heating Indoor 20ºC DB. Heating Outdoor 7ºC DB / 6ºC WB.(DB: Dry Bulb; WB: Wet Bulb)
For detailed information about ErP, please visit our page http://www.haier.com/ecodesign.

51 52
Key Features Features

• -15°C Heating

20
dB(A)
• -10°C Cooling
20m • Easy Support Clip

Whispering Air Wi-Fi control Long Distance Nano-aqua 3D Airflow


• Wired Controller Transfer Kit
Air Supplying • Auto Horizontal Airflow (One Motor)

Nebula
A++/A+
Outdoor Remote Controller USB Wi-Fi Wired Controller
AS07NS1HRA AS09NS1HRA AS12NS1HRA AS15NS1HRA
Whispering Air Quiet to 20dB(A) AS18NS1HRA AS24NS1HRA

AS07NS1HRA-WU AS09NS1HRA-WU AS12NS1HRA-WU AS15NS1HRA-WU AS18NS1HRA-WU AS24NS1HRA-WU


Indoor AS07NS1HRA-GU AS09NS1HRA-GU AS12NS1HRA-GU AS15NS1HRA-GU AS18NS1HRA-GU AS24NS1HRA-GU
Model
Outdoor 1U09BS3ERA 1U12BS3ERA 1U15BS3ERA 1U18FS2ERA(S) 1U24GS1ERA
Nominal (Min.~Max.) Btu/h 9210(2730-11600) 12290(3410-14330) 15010(4430-17060) 17740(4440-23200) 23890(7500-29010)
Cooling Capacity
Nominal (Min.~Max.) kW 2.7(0.8-3.4) 3.6(1.0-4.2) 4.4(1.3-5.0) 5.2(1.3-6.8) 7.0(2.2-8.5)
Energy efficiency(average climate) SEER/EER Energy Saving 6.40/3.80 6.10/3.60 6.90/3.8 6.20/3.40 6.10/3.21
Energy class - Cooling A++ A++ A++ A++ A++
Cooling Pdesign capacity(35°C) kW 2.7 3.6 4.4 5.2 7
Power input - Cooling Nominal (Min.~Max.) kW 0.71(0.35-1.30) 1.00(0.37-1.35) 1.16(0.41-1.9) 1.53(0.4-2.25) 2.18(0.45-2.65)
Annual energy consumption - Cooling kWh/a 148 207 223 293 401
Nominal (Min.~Max.) Btu/h 9560(3420-15700) 12630(3750-18430) 18430(4780-20480) 19790(4770-23550) 25600(8190-33460)
Heating @ -7ºC Btu/h 7350 9900 12000 15700 17060
Heating Capacity
Nominal (Min.~Max.) kW Multi 2.8(1.0-4.6) 3.7(1.1-5.4) 5.4(1.7-6.0) 5.8(1.4-6.9) 7.5(2.4-9.8)

20
dB(A) Whispering Air Energy efficiency
Heating @ -7ºC kW
SCOP/COP(Average climate) Energy Saving
Connection
Only
2.2
4.00/4.10
2.9
4.00/3.90
3.5
4.20/4.00
4.6
4.00/3.41
5.0
4.00/3.41
SCOP(Warm/Cold climate) 4.32/- 4.31/- 4.32/- 4.30/- 4.30/-
20dB(A)

20
Energy class - Heating Average/warm/cold A+/A+/- A+/A+/- A+/A+/- A+/A+/- A+/A+/-
Optimize the noise control technology, such as the compressor Heating Pdesign capacity (-10°C) kW 2.4 3.2 4 5.2 5.6
frequency adjustment, fan speed control and air flue design Power input - Heating Nominal (Min.~Max.) kW 0.68(0.36-1.30) 0.95(0.38-1.40) 1.35(0.42-2.2) 1.70(0.41-2.35) 2.20(0.48-2.95)

decreasing the noise level even lowest to 20dB(A) with the dB(A) Annual energy consumption - Heating kWh/a 830 1114 1333 1832 1979
Operating limits (cooling) Min.~Max. ºC 21-35ºC(in)/-10-43ºC(out) 21-35ºC(in)/-10-43ºC(out) 21-35ºC(in)/-10-43ºC(out) 21-35ºC(in)/-10-43ºC(out) 21-35ºC(in)/-10-43ºC(out)
specialized QUIET setting. (refer to 9k) Operating limits (heating) Min.~Max. ºC 10-27ºC(in)/-15-24ºC(out) 10-27ºC(in)/-15-24ºC(out) 10-27ºC(in)/-15-24ºC(out) 10-27ºC(in)/-15-24ºC(out) 10-27ºC(in)/-15-24ºC(out)
Power supply Ph/V/Hz 1/230/50 1/230/50 1/230/50 1/230/50 1/230/50
Power supply (position) outdoor outdoor outdoor outdoor outdoor
40H FCL (set) *just for reference 240 240 188 160 132
Indoor
Net dimension W/D/H mm 855/200/280 855/200/280 855/200/280 900/210/310 997/230/322 1115/243/336
Package dimension W/D/H mm 954/279/355 954/279/355 954/279/355 991/313/399 1085/329/403 1206/342/418
Net/Shipping weight kg - 10/12.2 10/12.2 10.8/13.6 13/16 15.6/19.0

Wi-Fi Control Air flow(cooling/heating) Max.


Cooling (Hi)
m³/h
dB
-
-
600
55
650
54
700
55
900
57
1200
62
Sound power level
Heating (Hi) dB - 56 55 56 58 63
Cooling (Hi/Mid/Lo/So) dB(A) - 38/33/26/20 39/34/27/23 43/39/33/25 44/40/35/28 47/43/37/30
Control your air conditioning system with smart phone or tablet, Sound pressure level
Heating (Hi/Mid/Lo/So) dB(A) - 39/33/26/23 40/34/27/24 44/39/33/25 45/40/35/33 48/44/38/36
which can connect internet. Moisture removal 10¯³m³/h - 1.2 1.6 1.8 2 2.8
Outdoor
Compressor Panasonic Panasonic Mitsubishi Mitsubishi Mitsubishi
Net dimension W/D/H mm 780/245/540 780/245/540 780/290/597 810/288/688 860/308/730
Package dimension W/D/H mm 920/351/620 920/351/620 923/393/680 949/406/760 995/420/813
Net/Shipping weight kg 28.4/31.4 30.4/33.4 36.5/40 43/47 49/52
Air flow(cooling/heating) Max. m³/h 1900 1700 2100 2200 2900
Sound power level Hi dB 61/62 62/63 63/64 63/64 67/68

20m+
Sound pressure level Hi dB(A) Multi 48/52 50/53 52/53 52/54 54/56
Running current Max. A
Airflow Speed(m/s)

Connection 5.8 6.4 8.6 10.2 13.1


Airflow
Refrigerant type

Long Distance Air Supplying


R410A/R32 Only R410A R410A R410A R410A R410A
Refrigerant charge R410A/R32 g 750 1000 1100 1300 1600
20m 8 8.0
Liquid side diameter mm / inch 6.35 6.35 6.35 6.35 9.52
Gas side diameter mm / inch 9.52 9.52 9.52 12.7 15.88
m
The indoor unit is improved by the optimized motor, fan and 2 2.0 1.9
Refrigerant pipe Max. pipe length/height 15/10 15/10 15/10 25/15 25/15
Max. pipe length without
air flue so as to provide long distance airflow with 20m+ 1 0.8 0.7 0.4 Airflow additional charge
m 7 7 7 10 10
Speed(m/s)
maximum. (refer to 24K). 0
5 10 15 20 23 distance(m)
additional charge g/m 20 20 20 20 50

Test condition: Test is made with NEBULA 24000BTU models with fan speed set turbo under stable
working condition in an air tight room. Rating Conditions: Cooling Indoor 27ºC DB / 19ºC WB. Cooling Outdoor 35ºC DB / 24ºC WB. Heating Indoor 20ºC DB. Heating Outdoor 7ºC DB / 6ºC WB.(DB: Dry Bulb; WB: Wet Bulb)
For detailed information about ERP, please visit our page http://www.haier.com/ecodesign.

53 54
Key Features Features

• -15°C Heating

20
dB(A)
• -10°C Cooling
20m • Easy Support Clip

Whispering Air Wi-Fi control Long Distance Nano-aqua 3D Airflow


• Wired Controller Transfer Kit
Air Supplying • Auto Horizontal Airflow (One Motor)

Nebula
A++/A+
Outdoor Remote Controller USB Wi-Fi Wired Controller
AS07NS1HRA AS09NS1HRA AS12NS1HRA AS15NS1HRA
Whispering Air Quiet to 20dB(A) AS18NS1HRA AS24NS1HRA

AS07NS1HRA-WU AS09NS1HRA-WU AS12NS1HRA-WU AS15NS1HRA-WU AS18NS1HRA-WU AS24NS1HRA-WU


Indoor AS07NS1HRA-GU AS09NS1HRA-GU AS12NS1HRA-GU AS15NS1HRA-GU AS18NS1HRA-GU AS24NS1HRA-GU
Model
Outdoor 1U09BS3ERA 1U12BS3ERA 1U15BS3ERA 1U18FS2ERA(S) 1U24GS1ERA
Nominal (Min.~Max.) Btu/h 9210(2730-11600) 12290(3410-14330) 15010(4430-17060) 17740(4440-23200) 23890(7500-29010)
Cooling Capacity
Nominal (Min.~Max.) kW 2.7(0.8-3.4) 3.6(1.0-4.2) 4.4(1.3-5.0) 5.2(1.3-6.8) 7.0(2.2-8.5)
Energy efficiency(average climate) SEER/EER Energy Saving 6.40/3.80 6.10/3.60 6.90/3.8 6.20/3.40 6.10/3.21
Energy class - Cooling A++ A++ A++ A++ A++
Cooling Pdesign capacity(35°C) kW 2.7 3.6 4.4 5.2 7
Power input - Cooling Nominal (Min.~Max.) kW 0.71(0.35-1.30) 1.00(0.37-1.35) 1.16(0.41-1.9) 1.53(0.4-2.25) 2.18(0.45-2.65)
Annual energy consumption - Cooling kWh/a 148 207 223 293 401
Nominal (Min.~Max.) Btu/h 9560(3420-15700) 12630(3750-18430) 18430(4780-20480) 19790(4770-23550) 25600(8190-33460)
Heating @ -7ºC Btu/h 7350 9900 12000 15700 17060
Heating Capacity
Nominal (Min.~Max.) kW Multi 2.8(1.0-4.6) 3.7(1.1-5.4) 5.4(1.7-6.0) 5.8(1.4-6.9) 7.5(2.4-9.8)

20
dB(A) Whispering Air Energy efficiency
Heating @ -7ºC kW
SCOP/COP(Average climate) Energy Saving
Connection
Only
2.2
4.00/4.10
2.9
4.00/3.90
3.5
4.20/4.00
4.6
4.00/3.41
5.0
4.00/3.41
SCOP(Warm/Cold climate) 4.32/- 4.31/- 4.32/- 4.30/- 4.30/-
20dB(A)

20
Energy class - Heating Average/warm/cold A+/A+/- A+/A+/- A+/A+/- A+/A+/- A+/A+/-
Optimize the noise control technology, such as the compressor Heating Pdesign capacity (-10°C) kW 2.4 3.2 4 5.2 5.6
frequency adjustment, fan speed control and air flue design Power input - Heating Nominal (Min.~Max.) kW 0.68(0.36-1.30) 0.95(0.38-1.40) 1.35(0.42-2.2) 1.70(0.41-2.35) 2.20(0.48-2.95)

decreasing the noise level even lowest to 20dB(A) with the dB(A) Annual energy consumption - Heating kWh/a 830 1114 1333 1832 1979
Operating limits (cooling) Min.~Max. ºC 21-35ºC(in)/-10-43ºC(out) 21-35ºC(in)/-10-43ºC(out) 21-35ºC(in)/-10-43ºC(out) 21-35ºC(in)/-10-43ºC(out) 21-35ºC(in)/-10-43ºC(out)
specialized QUIET setting. (refer to 9k) Operating limits (heating) Min.~Max. ºC 10-27ºC(in)/-15-24ºC(out) 10-27ºC(in)/-15-24ºC(out) 10-27ºC(in)/-15-24ºC(out) 10-27ºC(in)/-15-24ºC(out) 10-27ºC(in)/-15-24ºC(out)
Power supply Ph/V/Hz 1/230/50 1/230/50 1/230/50 1/230/50 1/230/50
Power supply (position) outdoor outdoor outdoor outdoor outdoor
40H FCL (set) *just for reference 240 240 188 160 132
Indoor
Net dimension W/D/H mm 855/200/280 855/200/280 855/200/280 900/210/310 997/230/322 1115/243/336
Package dimension W/D/H mm 954/279/355 954/279/355 954/279/355 991/313/399 1085/329/403 1206/342/418
Net/Shipping weight kg - 10/12.2 10/12.2 10.8/13.6 13/16 15.6/19.0

Wi-Fi Control Air flow(cooling/heating) Max.


Cooling (Hi)
m³/h
dB
-
-
600
55
650
54
700
55
900
57
1200
62
Sound power level
Heating (Hi) dB - 56 55 56 58 63
Cooling (Hi/Mid/Lo/So) dB(A) - 38/33/26/20 39/34/27/23 43/39/33/25 44/40/35/28 47/43/37/30
Control your air conditioning system with smart phone or tablet, Sound pressure level
Heating (Hi/Mid/Lo/So) dB(A) - 39/33/26/23 40/34/27/24 44/39/33/25 45/40/35/33 48/44/38/36
which can connect internet. Moisture removal 10¯³m³/h - 1.2 1.6 1.8 2 2.8
Outdoor
Compressor Panasonic Panasonic Mitsubishi Mitsubishi Mitsubishi
Net dimension W/D/H mm 780/245/540 780/245/540 780/290/597 810/288/688 860/308/730
Package dimension W/D/H mm 920/351/620 920/351/620 923/393/680 949/406/760 995/420/813
Net/Shipping weight kg 28.4/31.4 30.4/33.4 36.5/40 43/47 49/52
Air flow(cooling/heating) Max. m³/h 1900 1700 2100 2200 2900
Sound power level Hi dB 61/62 62/63 63/64 63/64 67/68

20m+
Sound pressure level Hi dB(A) Multi 48/52 50/53 52/53 52/54 54/56
Running current Max. A
Airflow Speed(m/s)

Connection 5.8 6.4 8.6 10.2 13.1


Airflow
Refrigerant type

Long Distance Air Supplying


R410A/R32 Only R410A R410A R410A R410A R410A
Refrigerant charge R410A/R32 g 750 1000 1100 1300 1600
20m 8 8.0
Liquid side diameter mm / inch 6.35 6.35 6.35 6.35 9.52
Gas side diameter mm / inch 9.52 9.52 9.52 12.7 15.88
m
The indoor unit is improved by the optimized motor, fan and 2 2.0 1.9
Refrigerant pipe Max. pipe length/height 15/10 15/10 15/10 25/15 25/15
Max. pipe length without
air flue so as to provide long distance airflow with 20m+ 1 0.8 0.7 0.4 Airflow additional charge
m 7 7 7 10 10
Speed(m/s)
maximum. (refer to 24K). 0
5 10 15 20 23 distance(m)
additional charge g/m 20 20 20 20 50

Test condition: Test is made with NEBULA 24000BTU models with fan speed set turbo under stable
working condition in an air tight room. Rating Conditions: Cooling Indoor 27ºC DB / 19ºC WB. Cooling Outdoor 35ºC DB / 24ºC WB. Heating Indoor 20ºC DB. Heating Outdoor 7ºC DB / 6ºC WB.(DB: Dry Bulb; WB: Wet Bulb)
For detailed information about ERP, please visit our page http://www.haier.com/ecodesign.

53 54
Key Features Features

• Easy Support Clip


• Wired Controller Transfer Kit
20
dB(A) • 2-way Piping Design
• Super Match
Whispering Air A-PAM Intelligent Air -15°C Heating -10°C Cooling
Inverter Control

Brezza
Outdoor Remote Controller USB Wi-Fi Wired Controller
A++/A+ AS07BS4HRA AS09BS4HRA AS12BS4HRA AS15BS4HRA
Whispering Air Quiet to 20dB(A) AS18BS4HRA AS24BS4HRA

Indoor AS07BS4HRA AS09BS4HRA AS12BS4HRA AS15BS4HRA AS18BS4HRA AS24BS4HRA


Model
Outdoor 1U09BS3ERA 1U12BS3ERA 1U15BS3ERA 1U18FS2ERA(S) 1U24GS1ERA
Nominal (Min.~Max.) Btu/h 9210(2730-11600) 12290(3420-14330) 15010(4430-17060) 17740(4440-23200) 23890(7500-29010)
Cooling Capacity
Nominal (Min.~Max.) kW 2.7(0.8-3.4) 3.6(1.0-4.2) 4.4(1.3-5.0) 5.2(1.3-6.8) 7.0(2.2-8.5)
Energy efficiency(average climate) SEER/EER Energy Saving 6.40/3.80 6.10/3.60 6.90/3.8 6.20/3.40 6.10/3.21
Energy class - Cooling A++ A++ A++ A++ A++
Cooling Pdesign capacity(35°C) kW 2.7 3.6 4.4 5.2 7.00
Power input - Cooling Nominal (Min.~Max.) kW 0.71(0.35-1.30) 1.00(0.37-1.35) 1.16(0.41-1.9) 1.53(0.4-2.25) 2.18(0.45-2.65)
Annual energy consumption - Cooling kWh/a 148 207 223 293 401
Nominal (Min.~Max.) Btu/h 9560(3420-15700) 12630(3750-18430) 18430(4780-20480) 19790(4770-23550) 25600(8190-33460)
Heating @ -7ºC Btu/h 7350 9900 12000 15700 17060
Heating Capacity

Whispering Air
Nominal (Min.~Max.) kW Multi 2.8(1.0-4.6) 3.7(1.1-5.4) 5.4(1.7-6.0) 5.8(1.4-6.9) 7.5(2.4-9.8)
20
dB(A) Heating @ -7ºC kW Connection 2.2 2.9 3.5 4.6 5.0
SCOP/COP(Average climate) Energy Saving Only 4.00/4.10 4.00/3.90 4.20/4.00 4.00/3.41 4.00/3.41
20dB(A) Energy efficiency
SCOP(Warm/Cold climate) 4.32/- 4.31/- 4.32/- 4.30/- 4.30/-

Optimize the noise control technology, such as the compressor


20
Energy class - Heating Average/warm/cold A+/A+/- A+/A+/- A+/A+/- A+/A+/- A+/A+/-
Heating Pdesign capacity (-10°C) kW 2.4 3.2 4.0 5.2 5.6
frequency adjustment, fan speed control and air flue design Power input - Heating Nominal (Min.~Max.) kW 0.68(0.36-1.30) 0.95(0.38-1.40) 1.35(0.42-2.2) 1.70(0.41-2.35) 2.20(0.48-2.95)
decreasing the noise level even lowest to 20dB(A) with the dB(A) Annual energy consumption - Heating kWh/a 830 1114 1333 1832 1979
specialized QUIET setting. (refer to 9k) Operating limits (cooling) Min.~Max. ºC 21-35°C(in)/-10-43°C(out) 21-35°C(in)/-10-43°C(out) 21-35°C(in)/-10-43°C(out) 21-35°C(in)/-10-43°C(out) 21-35°C(in)/-10-43°C(out)
Operating limits (heating) Min.~Max. ºC 10-27°C(in)/-15-24°C(out) 10-27°C(in)/-15-24°C(out) 10-27°C(in)/-15-24°C(out) 10-27°C(in)/-15-24°C(out) 10-27°C(in)/-15-24°C(out)
Power supply Ph/V/Hz 1/230/50 1/230/50 1/230/50 1/230/50 1/230/50
Power supply (position) outdoor outdoor outdoor outdoor outdoor
40H FCL (set) *just for reference 240 240 188 160 132
Indoor
Temperature Reducing Comparison Net dimension W/D/H mm 855/200/280 855/200/280 855/200/280 900/210/310 997/230/322 1115/243/336
Temperature

30
Package dimension W/D/H mm 954/279/355 954/279/355 954/279/355 991/313/399 1085/329/403 1206/342/418
29

A-PAM Inverter Control 28


Net/Shipping weight
Air flow(cooling/heating) Max.
kg
m³/h
-
-
10/12.2
600
10/12.2
650
10.8/13.6
700
13/16
900
15.6/19.0
1200
27 A-PAM Cooling (Hi) dB - 52 54 55 57 62
Sound power level
26 S-PAM Heating (Hi) dB - 53 55 56 58 63
A-PAM inverter technology is the upgrade of 180° sine wave 25 Cooling (Hi/Mid/Lo/So) dB(A) - 38/33/26/20 39/34/27/23 43/39/33/25 44/40/35/28 47/43/37/30
Sound pressure level
inverter, it adopts additional momental control to decrease the 24
Heating (Hi/Mid/Lo/So) dB(A) - 39/33/26/23 40/34/27/24 44/39/33/25 45/40/35/33 48/44/38/36
Moisture removal 10¯³m³/h - 1.2 1.6 1.8 2 2.8
vibration in the low compressor frequency and also contribute to 26
Outdoor
great energy saving. 22 Mins Compressor Panasonic Panasonic Mitsubishi Mitsubishi Mitsubishi
8 16 24 32 40 48
Net dimension W/D/H mm 780/245/540 780/245/540 780/290/597 810/288/688 860/308/730
Package dimension W/D/H mm 920/351/620 920/351/620 923/393/680 949/406/760 995/420/813
Net/Shipping weight kg 28.4/31.4 30.4/33.4 36.5/40 43/47 49/52
Air flow(cooling/heating) Max. m³/h 1900 1700 2100 2200 2900
Sound power level Hi dB 61/62 62/63 63/64 63/64 67/68
Sound pressure level Hi dB(A) Multi 48/52 50/53 52/53 52/54 54/56
Running current Max. A Connection 5.8 6.4 8.6 10.2 13.1

Intelligent Air Refrigerant type


Refrigerant charge
R410A/R32
R410A/R32 g
Only R410A
750
R410A
1000
R410A
1100
R410A
1300
R410A
1600
Liquid side diameter mm / inch 6.35 6.35 6.35 6.35 9.52
Gas side diameter mm / inch 9.52 9.52 9.52 12.7 15.88
Airflow automatically upward when cooling or downward when Refrigerant pipe Max. pipe length/height m 15/10 15/10 15/10 25/15 25/15
heating to spread air automatically throughout the large room Max. pipe length without
m 7 7 7 10 10
additional charge
while without blowing directly to human body.
additional charge g/m 20 20 20 20 50

Rating Conditions: Cooling Indoor 27ºC DB / 19ºC WB. Cooling Outdoor 35ºC DB / 24ºC WB. Heating Indoor 20ºC DB. Heating Outdoor 7ºC DB / 6ºC WB.(DB: Dry Bulb; WB: Wet Bulb)
For detailed information about ERP, please visit our page http://www.haier.com/ecodesign.

55 56
Key Features Features

• Easy Support Clip


• Wired Controller Transfer Kit
20
dB(A) • 2-way Piping Design
• Super Match
Whispering Air A-PAM Intelligent Air -15°C Heating -10°C Cooling
Inverter Control

Brezza
Outdoor Remote Controller USB Wi-Fi Wired Controller
A++/A+ AS07BS4HRA AS09BS4HRA AS12BS4HRA AS15BS4HRA
Whispering Air Quiet to 20dB(A) AS18BS4HRA AS24BS4HRA

Indoor AS07BS4HRA AS09BS4HRA AS12BS4HRA AS15BS4HRA AS18BS4HRA AS24BS4HRA


Model
Outdoor 1U09BS3ERA 1U12BS3ERA 1U15BS3ERA 1U18FS2ERA(S) 1U24GS1ERA
Nominal (Min.~Max.) Btu/h 9210(2730-11600) 12290(3420-14330) 15010(4430-17060) 17740(4440-23200) 23890(7500-29010)
Cooling Capacity
Nominal (Min.~Max.) kW 2.7(0.8-3.4) 3.6(1.0-4.2) 4.4(1.3-5.0) 5.2(1.3-6.8) 7.0(2.2-8.5)
Energy efficiency(average climate) SEER/EER Energy Saving 6.40/3.80 6.10/3.60 6.90/3.8 6.20/3.40 6.10/3.21
Energy class - Cooling A++ A++ A++ A++ A++
Cooling Pdesign capacity(35°C) kW 2.7 3.6 4.4 5.2 7.00
Power input - Cooling Nominal (Min.~Max.) kW 0.71(0.35-1.30) 1.00(0.37-1.35) 1.16(0.41-1.9) 1.53(0.4-2.25) 2.18(0.45-2.65)
Annual energy consumption - Cooling kWh/a 148 207 223 293 401
Nominal (Min.~Max.) Btu/h 9560(3420-15700) 12630(3750-18430) 18430(4780-20480) 19790(4770-23550) 25600(8190-33460)
Heating @ -7ºC Btu/h 7350 9900 12000 15700 17060
Heating Capacity

Whispering Air
Nominal (Min.~Max.) kW Multi 2.8(1.0-4.6) 3.7(1.1-5.4) 5.4(1.7-6.0) 5.8(1.4-6.9) 7.5(2.4-9.8)
20
dB(A) Heating @ -7ºC kW Connection 2.2 2.9 3.5 4.6 5.0
SCOP/COP(Average climate) Energy Saving Only 4.00/4.10 4.00/3.90 4.20/4.00 4.00/3.41 4.00/3.41
20dB(A) Energy efficiency
SCOP(Warm/Cold climate) 4.32/- 4.31/- 4.32/- 4.30/- 4.30/-

Optimize the noise control technology, such as the compressor


20
Energy class - Heating Average/warm/cold A+/A+/- A+/A+/- A+/A+/- A+/A+/- A+/A+/-
Heating Pdesign capacity (-10°C) kW 2.4 3.2 4.0 5.2 5.6
frequency adjustment, fan speed control and air flue design Power input - Heating Nominal (Min.~Max.) kW 0.68(0.36-1.30) 0.95(0.38-1.40) 1.35(0.42-2.2) 1.70(0.41-2.35) 2.20(0.48-2.95)
decreasing the noise level even lowest to 20dB(A) with the dB(A) Annual energy consumption - Heating kWh/a 830 1114 1333 1832 1979
specialized QUIET setting. (refer to 9k) Operating limits (cooling) Min.~Max. ºC 21-35°C(in)/-10-43°C(out) 21-35°C(in)/-10-43°C(out) 21-35°C(in)/-10-43°C(out) 21-35°C(in)/-10-43°C(out) 21-35°C(in)/-10-43°C(out)
Operating limits (heating) Min.~Max. ºC 10-27°C(in)/-15-24°C(out) 10-27°C(in)/-15-24°C(out) 10-27°C(in)/-15-24°C(out) 10-27°C(in)/-15-24°C(out) 10-27°C(in)/-15-24°C(out)
Power supply Ph/V/Hz 1/230/50 1/230/50 1/230/50 1/230/50 1/230/50
Power supply (position) outdoor outdoor outdoor outdoor outdoor
40H FCL (set) *just for reference 240 240 188 160 132
Indoor
Temperature Reducing Comparison Net dimension W/D/H mm 855/200/280 855/200/280 855/200/280 900/210/310 997/230/322 1115/243/336
Temperature

30
Package dimension W/D/H mm 954/279/355 954/279/355 954/279/355 991/313/399 1085/329/403 1206/342/418
29

A-PAM Inverter Control 28


Net/Shipping weight
Air flow(cooling/heating) Max.
kg
m³/h
-
-
10/12.2
600
10/12.2
650
10.8/13.6
700
13/16
900
15.6/19.0
1200
27 A-PAM Cooling (Hi) dB - 52 54 55 57 62
Sound power level
26 S-PAM Heating (Hi) dB - 53 55 56 58 63
A-PAM inverter technology is the upgrade of 180° sine wave 25 Cooling (Hi/Mid/Lo/So) dB(A) - 38/33/26/20 39/34/27/23 43/39/33/25 44/40/35/28 47/43/37/30
Sound pressure level
inverter, it adopts additional momental control to decrease the 24
Heating (Hi/Mid/Lo/So) dB(A) - 39/33/26/23 40/34/27/24 44/39/33/25 45/40/35/33 48/44/38/36
Moisture removal 10¯³m³/h - 1.2 1.6 1.8 2 2.8
vibration in the low compressor frequency and also contribute to 26
Outdoor
great energy saving. 22 Mins Compressor Panasonic Panasonic Mitsubishi Mitsubishi Mitsubishi
8 16 24 32 40 48
Net dimension W/D/H mm 780/245/540 780/245/540 780/290/597 810/288/688 860/308/730
Package dimension W/D/H mm 920/351/620 920/351/620 923/393/680 949/406/760 995/420/813
Net/Shipping weight kg 28.4/31.4 30.4/33.4 36.5/40 43/47 49/52
Air flow(cooling/heating) Max. m³/h 1900 1700 2100 2200 2900
Sound power level Hi dB 61/62 62/63 63/64 63/64 67/68
Sound pressure level Hi dB(A) Multi 48/52 50/53 52/53 52/54 54/56
Running current Max. A Connection 5.8 6.4 8.6 10.2 13.1

Intelligent Air Refrigerant type


Refrigerant charge
R410A/R32
R410A/R32 g
Only R410A
750
R410A
1000
R410A
1100
R410A
1300
R410A
1600
Liquid side diameter mm / inch 6.35 6.35 6.35 6.35 9.52
Gas side diameter mm / inch 9.52 9.52 9.52 12.7 15.88
Airflow automatically upward when cooling or downward when Refrigerant pipe Max. pipe length/height m 15/10 15/10 15/10 25/15 25/15
heating to spread air automatically throughout the large room Max. pipe length without
m 7 7 7 10 10
additional charge
while without blowing directly to human body.
additional charge g/m 20 20 20 20 50

Rating Conditions: Cooling Indoor 27ºC DB / 19ºC WB. Cooling Outdoor 35ºC DB / 24ºC WB. Heating Indoor 20ºC DB. Heating Outdoor 7ºC DB / 6ºC WB.(DB: Dry Bulb; WB: Wet Bulb)
For detailed information about ERP, please visit our page http://www.haier.com/ecodesign.

55 56
Key Features Features

• Easy & Quick Repair Motor


20
dB(A) • 2-way Piping Design

Whispering Air Intelligent Air Comfortable Sleep -15°C Heating Easy Support Clip

Tundra AS09TA2HRA AS12TA2HRA AS18TD2HRA AS24TD2HRA Outdoor Remote Controller

A++/A+
Whispering Air Quiet to 20dB(A) Model
Indoor
Outdoor
AS09TA2HRA
1U09BE8ERA
AS12TA2HRA
1U12BE8ERA
AS18TD2HRA
1U18EE8ERA
AS24TD2HRA
1U24RE8ERA
Nominal (Min.~Max.) Btu/h 8870(3410-11950) 12280(3410-14000) 17060(4100-21500) 22520(6820-27640)
Cooling Capacity
Nominal (Min.~Max.) kW 2.6(1.00-3.50) 3.6(1.00-4.10) 5.0(1.20-6.30) 6.6(2.00-8.10)
Energy efficiency(average climate) SEER/EER Energy Saving 6.20/3.21 6.10/2.81 6.20/3.24 6.20/3.01
Energy class - Cooling A++ A++ A++ A++
Cooling Pdesign capacity(35°C) kW 2.60 3.60 5.00 6.60
Power input - Cooling Nominal (Min.~Max.) kW 0.810(0.30-1.40) 1.28(0.30-1.60) 1.54(0.40-2.25) 2.19(0.60-2.70)
Annual energy consumption - Cooling kWh/a 147 206 282 373

Nominal (Min.~Max.) Btu/h 9550(3410-15020) 12630(3750-17750) 20470(3580-22860) 25250(8190-29690)

Heating @ -7°C Btu/h 7167 8190 14500 16720


Heating Capacity
Nominal (Min.~Max.) kW 2.8(1.00-4.40) 3.7(1.10-5.20) 6.0(1.05-6.70) 7.4(2.40-8.70)

Heating @ -7°C kW 2.1 2.4 4.25 4.9

SCOP/COP(Average climate) Energy Saving 4.00/3.61 4.00/3.61 4.00/3.72 3.90/3.61


Energy efficiency
SCOP(Warm/Cold climate) 4.70/- 4.80/- 5.18/- 5.00/-

Energy class - Heating Average/warm/cold A+/A++/- A+/A++/- A+/A+++/- A/A++/-


20
dB(A) Whispering Air Heating Pdesign capacity (-10°C)

Power input - Heating Nominal (Min.~Max.)


kW

kW
2.4

0.78(0.30-1.50)
2.8

1.02(0.50-1.60)
4.8

1.61(0.40-2.35)
5.6

2.05(0.7-2.9)
20dB(A)
Annual energy consumption - Heating kWh/a 841 981 1679 2011

Optimize the noise control technology, such as the compressor


frequency adjustment, fan speed control and air flue design
decreasing the noise level even lowest to 20dB(A) with the
20
dB(A)
Operating limits (cooling)

Operating limits (heating)

Power supply
Min.~Max.

Min.~Max.

Ph/V/Hz
°C

°C
21-35°C(in)/10-43°C(out)

10-27°C(in)/-15-24°C(out)

1/230/50
21-35°C(in)/10-43°C(out)

10-27°C(in)/-15-24°C(out)

1/230/50
21-35°C(in)/10-43°C(out)

10-27°C(in)/-15-24°C(out)

1/230/50
21-35°C(in)/10-43°C(out)

10-27°C(in)/-15-24°C(out)

1/230/50

specialized QUIET setting. (refer to 9k) Power supply (position) Indoor Indoor Indoor outdoor

40H FCL (set) *just for reference 240 240 185 136

Indoor

Net dimension W/D/H mm 820/195/280 820/195/280 1008/225/318 1008/225/318

Package dimension W/D/H mm 909/279/355 909/279/355 1085/329/403 1085/329/403

Net/Shipping weight kg 8.8/11.0 9.0/11.2 12/15 12/15

Air flow(cooling/heating) Max. m³/h 500 550 900 1100

Intelligent Air
Cooling (Hi) dB 53 54 57 60
Sound power level
Heating (Hi) dB 54 55 58 61

Cooling (Hi/Mid/Lo/So) dB(A) 36/30/26/20 37/32/28/20 40/37/35/28 42/38/36/28


Sound pressure level
Heating (Hi/Mid/Lo/So) dB(A) 36/30/26/20 37/32/28/20 40/37/35/28 42/38/36/28
Airflow automatically upward when cooling or downward when Moisture removal 10¯³m³/h 1.2 1.6 2.0 2.8
heating to spread air automatically throughout the large room Outdoor
while without blowing directly to human body. Compressor Hitachi Mitsubishi Mitsubishi Mitsubishi

Net dimension W/D/H mm 780/245/540 780/245/540 780/245/640 890/353/697

Package dimension W/D/H mm 920/351/620 920/351/620 920/351/720 1046/460/780

Net/Shipping weight kg 25.5/28.5 26/29 33.5/37 51/56

Air flow(cooling/heating) Max. m³/h 1600 1700 2200 2900

Sound power level Hi dB 61/62 62/63 63/64 65/66

Sound pressure level Hi dB(A) 49/50 50/51 51/52 52/53

Running current Max. A 6.7 7.1 10.2 13.5

Comfortable Sleep
Refrigerant type R410A/R32 R410A R410A R410A R410A

Refrigerant charge R410A/R32 g 780 780 1200 1450

Liquid side diameter mm / inch 6.35 6.35 6.35 6.35

Gas side diameter mm / inch 9.52 9.52 12.7 12.7


The setting temperature and the indoor noise can be adjusted Refrigerant pipe Max. pipe length/height m 15/10 15/10 25/15 25/15
to a more comfortable level when you set the "sleep mode" Max. pipe length without additional charge m 7 7 10 10
during night sleep. additional charge g/m 20 20 20 20

Rating Conditions: Cooling Indoor 27ºC DB / 19ºC WB. Cooling Outdoor 35ºC DB / 24ºC WB. Heating Indoor 20ºC DB. Heating Outdoor 7ºC DB / 6ºC WB.(DB: Dry Bulb; WB: Wet Bulb)
For detailed information about ErP, please visit our page http://www.haier.com/ecodesign.

57 58
Key Features Features

• Easy & Quick Repair Motor


20
dB(A) • 2-way Piping Design

Whispering Air Intelligent Air Comfortable Sleep -15°C Heating Easy Support Clip

Tundra AS09TA2HRA AS12TA2HRA AS18TD2HRA AS24TD2HRA Outdoor Remote Controller

A++/A+
Whispering Air Quiet to 20dB(A) Model
Indoor
Outdoor
AS09TA2HRA
1U09BE8ERA
AS12TA2HRA
1U12BE8ERA
AS18TD2HRA
1U18EE8ERA
AS24TD2HRA
1U24RE8ERA
Nominal (Min.~Max.) Btu/h 8870(3410-11950) 12280(3410-14000) 17060(4100-21500) 22520(6820-27640)
Cooling Capacity
Nominal (Min.~Max.) kW 2.6(1.00-3.50) 3.6(1.00-4.10) 5.0(1.20-6.30) 6.6(2.00-8.10)
Energy efficiency(average climate) SEER/EER Energy Saving 6.20/3.21 6.10/2.81 6.20/3.24 6.20/3.01
Energy class - Cooling A++ A++ A++ A++
Cooling Pdesign capacity(35°C) kW 2.60 3.60 5.00 6.60
Power input - Cooling Nominal (Min.~Max.) kW 0.810(0.30-1.40) 1.28(0.30-1.60) 1.54(0.40-2.25) 2.19(0.60-2.70)
Annual energy consumption - Cooling kWh/a 147 206 282 373

Nominal (Min.~Max.) Btu/h 9550(3410-15020) 12630(3750-17750) 20470(3580-22860) 25250(8190-29690)

Heating @ -7°C Btu/h 7167 8190 14500 16720


Heating Capacity
Nominal (Min.~Max.) kW 2.8(1.00-4.40) 3.7(1.10-5.20) 6.0(1.05-6.70) 7.4(2.40-8.70)

Heating @ -7°C kW 2.1 2.4 4.25 4.9

SCOP/COP(Average climate) Energy Saving 4.00/3.61 4.00/3.61 4.00/3.72 3.90/3.61


Energy efficiency
SCOP(Warm/Cold climate) 4.70/- 4.80/- 5.18/- 5.00/-

Energy class - Heating Average/warm/cold A+/A++/- A+/A++/- A+/A+++/- A/A++/-


20
dB(A) Whispering Air Heating Pdesign capacity (-10°C)

Power input - Heating Nominal (Min.~Max.)


kW

kW
2.4

0.78(0.30-1.50)
2.8

1.02(0.50-1.60)
4.8

1.61(0.40-2.35)
5.6

2.05(0.7-2.9)
20dB(A)
Annual energy consumption - Heating kWh/a 841 981 1679 2011

Optimize the noise control technology, such as the compressor


frequency adjustment, fan speed control and air flue design
decreasing the noise level even lowest to 20dB(A) with the
20
dB(A)
Operating limits (cooling)

Operating limits (heating)

Power supply
Min.~Max.

Min.~Max.

Ph/V/Hz
°C

°C
21-35°C(in)/10-43°C(out)

10-27°C(in)/-15-24°C(out)

1/230/50
21-35°C(in)/10-43°C(out)

10-27°C(in)/-15-24°C(out)

1/230/50
21-35°C(in)/10-43°C(out)

10-27°C(in)/-15-24°C(out)

1/230/50
21-35°C(in)/10-43°C(out)

10-27°C(in)/-15-24°C(out)

1/230/50

specialized QUIET setting. (refer to 9k) Power supply (position) Indoor Indoor Indoor outdoor

40H FCL (set) *just for reference 240 240 185 136

Indoor

Net dimension W/D/H mm 820/195/280 820/195/280 1008/225/318 1008/225/318

Package dimension W/D/H mm 909/279/355 909/279/355 1085/329/403 1085/329/403

Net/Shipping weight kg 8.8/11.0 9.0/11.2 12/15 12/15

Air flow(cooling/heating) Max. m³/h 500 550 900 1100

Intelligent Air
Cooling (Hi) dB 53 54 57 60
Sound power level
Heating (Hi) dB 54 55 58 61

Cooling (Hi/Mid/Lo/So) dB(A) 36/30/26/20 37/32/28/20 40/37/35/28 42/38/36/28


Sound pressure level
Heating (Hi/Mid/Lo/So) dB(A) 36/30/26/20 37/32/28/20 40/37/35/28 42/38/36/28
Airflow automatically upward when cooling or downward when Moisture removal 10¯³m³/h 1.2 1.6 2.0 2.8
heating to spread air automatically throughout the large room Outdoor
while without blowing directly to human body. Compressor Hitachi Mitsubishi Mitsubishi Mitsubishi

Net dimension W/D/H mm 780/245/540 780/245/540 780/245/640 890/353/697

Package dimension W/D/H mm 920/351/620 920/351/620 920/351/720 1046/460/780

Net/Shipping weight kg 25.5/28.5 26/29 33.5/37 51/56

Air flow(cooling/heating) Max. m³/h 1600 1700 2200 2900

Sound power level Hi dB 61/62 62/63 63/64 65/66

Sound pressure level Hi dB(A) 49/50 50/51 51/52 52/53

Running current Max. A 6.7 7.1 10.2 13.5

Comfortable Sleep
Refrigerant type R410A/R32 R410A R410A R410A R410A

Refrigerant charge R410A/R32 g 780 780 1200 1450

Liquid side diameter mm / inch 6.35 6.35 6.35 6.35

Gas side diameter mm / inch 9.52 9.52 12.7 12.7


The setting temperature and the indoor noise can be adjusted Refrigerant pipe Max. pipe length/height m 15/10 15/10 25/15 25/15
to a more comfortable level when you set the "sleep mode" Max. pipe length without additional charge m 7 7 10 10
during night sleep. additional charge g/m 20 20 20 20

Rating Conditions: Cooling Indoor 27ºC DB / 19ºC WB. Cooling Outdoor 35ºC DB / 24ºC WB. Heating Indoor 20ºC DB. Heating Outdoor 7ºC DB / 6ºC WB.(DB: Dry Bulb; WB: Wet Bulb)
For detailed information about ErP, please visit our page http://www.haier.com/ecodesign.

57 58
Multi Outdoor Models Multi Outdoor Models

2U14CS4ERA 1:2 2U18FS2ERA(S) 1:2 2U40S2SC1FA 1:2 2U50S2SF1FA 1:2

Whispering Air Wi-Fi Control 3D Airflow Wired Controller On-Off Card 3M Layers Fiter Super Match Whispering Air Wi-Fi Control 3D Airflow Wired Controller On-Off Card 3M Layers Fiter Super Match II +
Transfer Kit Transfer Kit

-15°C Heating -10°C Cooling Long Life Reliable PCB Outdoor 6 Steps 3 Minutes Protection Electrical Deicer -15°C Heating -10°C Cooling Long Life Reliable PCB Outdoor 6 Steps 3 Minutes Protection Electrical Deicer
Fan Speed Fan Speed

Model/outdoor unit 2U14CS4ERA 2U18FS2ERA(S) 2U40S2SC1FA 2U50S2SC1FA 2U40S2SC1FA 2U50S2SC1FA


AS09BS4HRA+ 2*AS12BS4HRA AS25S2SD1FA+ 2*AS35S2SD1FA AS25S2SF1FA+ 2*AS35S2SF1FA
Indoor unit combinations AS12BS4HRA AS35S2SD1FA AS35S2SF1FA
Maximum connected quantity of indoor units 2 2 2 2 2 2
Btu/h (nor) 14000 17400 13700 17000 13700 17000
Cooling
kW nor(min~max) 1.2/4.1/4.5 1.3/5.1/5.8 1.1/4.0/4.8 1.3/5.1/6.0 1.1/4.0/4.8 1.3/5.0/6.0
Capacity
Btu/h (nor) 15000 19800 15000 19500 15000 19500
Heating
Nominal performance data kW nor(min~max) 1.5/4.4/5.0 1.9/5.8/6.6 1.8/4.4/5.2 1.8/5.7/6.6 1.8/4.4/5.2 1.8/5.7/6.6
Cooling kW nom(min~max) 0.29/1.07/1.4 0.35/1.54/2.07 0.3/1.0/1.6 0.38/1.41/2.4 0.3/1.02/1.65 0.35/1.43/2.38
Rated power input
Heating kW nom(min~max) 0.34/1.09/1.65 0.45/1.55/2.30 0.38/1.07/1.95 0.55/1.53/2.45 0.38/1.08/1.95 0.55/1.54/2.45
EER/COP 3.83/4.03 3.31/3.74 4.00/4.10 3.62/3.72 3.92/4.07 3.50/3.70
Cooling P design(35°C) kW 4.1 5.1 4.0 5.0 4.0 5.0
Heating P design(-10°C) kW 4.2 5.2 3.3 5.2 3.3 5.2
SEER/SCOP 6.10/4.00 6.10/4.00 6.20/4.00 6.50/4.00 6.20/4.00 6.50/4.00
Seasonal performance data
Energy class(Cooling/Heating) A++/A+ A++/A+ A++/A+ A++/A+ A++/A+ A++/A+
Annual energy consumption(Cooling) kW 235 292 226 269 226 269
Annual energy consumption(Heating) kW 1471 1821 1155 1815 1151 1817
Outdoor unit
Electrical Parameters Power supply Ph/V/Hz 1/230/50 1/230/50 1/230/50 1/230/50 1/230/50 1/230/50
Air flow (H/M/L) m/h 1900 2900 1900 2900 1900 2900
Performance Sound power level (H/M/L) dB(A) 62 63 62 63 62 63
Sound pressure level (H/M/L) dB(A) 52 53 52 53 52 53
External dimensions (W/D/H) mm 780/270/540 810/288/688 780/270/540 810/288/688 780/270/540 810/288/688
Shipping dimensions (W/D/H) mm 910/380/617 949/406/760 910/380/617 949/406/760 910/380/617 949/406/760
Net/Shipping weight kg 34.0/37.0 43.5/46.5 34.2/37.3 43.0/46.4 34.2/37.3 43.0/46.4
Compressor type Rotary Twin Rotary Twin Rotary Twin Rotary Twin Rotary Twin Rotary
Refrigerant type R410A R410A R32 R32 R32 R32
GWP 2088 2088 675 675 675 675
Refrigerant liquid pipe mm 2x6.35 2x6.35 2x6.35 2x6.35 2x6.35 2x6.35
Installation Refrigerant gas pipe mm 2x9.52 2x9.52 2x9.52 2x9.52 2x9.52 2x9.52
Total pipe length (Max) m 30 30 30 30 30 30
Single pipe length (Max) m 20 20 20 20 20 20
Max drop between I.U.&O.U m 15 15 15 15 15 15
Max drop between I.U.&I.U m 15 15 15 15 15 15
refrigerant load in factory kg 1.2 1.4 1.0 1.2 1.0 1.2
Maximum pipe length without charge refrigerant m 20 20 20 20 20 20
refrigerant charge quantity for extra length g/m 20 20 20 20 20 20
Cooling(Min-Max) °C -10~46 -10~46 -10~46 -10~46 -10~46 -10~46
Working temp
Heating(Min-Max) °C -15~24 -15~24 -15~24 -15~24 -15~24 -15~24

59 60
Multi Outdoor Models Multi Outdoor Models

2U14CS4ERA 1:2 2U18FS2ERA(S) 1:2 2U40S2SC1FA 1:2 2U50S2SF1FA 1:2

Whispering Air Wi-Fi Control 3D Airflow Wired Controller On-Off Card 3M Layers Fiter Super Match Whispering Air Wi-Fi Control 3D Airflow Wired Controller On-Off Card 3M Layers Fiter Super Match II +
Transfer Kit Transfer Kit

-15°C Heating -10°C Cooling Long Life Reliable PCB Outdoor 6 Steps 3 Minutes Protection Electrical Deicer -15°C Heating -10°C Cooling Long Life Reliable PCB Outdoor 6 Steps 3 Minutes Protection Electrical Deicer
Fan Speed Fan Speed

Model/outdoor unit 2U14CS4ERA 2U18FS2ERA(S) 2U40S2SC1FA 2U50S2SC1FA 2U40S2SC1FA 2U50S2SC1FA


AS09BS4HRA+ 2*AS12BS4HRA AS25S2SD1FA+ 2*AS35S2SD1FA AS25S2SF1FA+ 2*AS35S2SF1FA
Indoor unit combinations AS12BS4HRA AS35S2SD1FA AS35S2SF1FA
Maximum connected quantity of indoor units 2 2 2 2 2 2
Btu/h (nor) 14000 17400 13700 17000 13700 17000
Cooling
kW nor(min~max) 1.2/4.1/4.5 1.3/5.1/5.8 1.1/4.0/4.8 1.3/5.1/6.0 1.1/4.0/4.8 1.3/5.0/6.0
Capacity
Btu/h (nor) 15000 19800 15000 19500 15000 19500
Heating
Nominal performance data kW nor(min~max) 1.5/4.4/5.0 1.9/5.8/6.6 1.8/4.4/5.2 1.8/5.7/6.6 1.8/4.4/5.2 1.8/5.7/6.6
Cooling kW nom(min~max) 0.29/1.07/1.4 0.35/1.54/2.07 0.3/1.0/1.6 0.38/1.41/2.4 0.3/1.02/1.65 0.35/1.43/2.38
Rated power input
Heating kW nom(min~max) 0.34/1.09/1.65 0.45/1.55/2.30 0.38/1.07/1.95 0.55/1.53/2.45 0.38/1.08/1.95 0.55/1.54/2.45
EER/COP 3.83/4.03 3.31/3.74 4.00/4.10 3.62/3.72 3.92/4.07 3.50/3.70
Cooling P design(35°C) kW 4.1 5.1 4.0 5.0 4.0 5.0
Heating P design(-10°C) kW 4.2 5.2 3.3 5.2 3.3 5.2
SEER/SCOP 6.10/4.00 6.10/4.00 6.20/4.00 6.50/4.00 6.20/4.00 6.50/4.00
Seasonal performance data
Energy class(Cooling/Heating) A++/A+ A++/A+ A++/A+ A++/A+ A++/A+ A++/A+
Annual energy consumption(Cooling) kW 235 292 226 269 226 269
Annual energy consumption(Heating) kW 1471 1821 1155 1815 1151 1817
Outdoor unit
Electrical Parameters Power supply Ph/V/Hz 1/230/50 1/230/50 1/230/50 1/230/50 1/230/50 1/230/50
Air flow (H/M/L) m/h 1900 2900 1900 2900 1900 2900
Performance Sound power level (H/M/L) dB(A) 62 63 62 63 62 63
Sound pressure level (H/M/L) dB(A) 52 53 52 53 52 53
External dimensions (W/D/H) mm 780/270/540 810/288/688 780/270/540 810/288/688 780/270/540 810/288/688
Shipping dimensions (W/D/H) mm 910/380/617 949/406/760 910/380/617 949/406/760 910/380/617 949/406/760
Net/Shipping weight kg 34.0/37.0 43.5/46.5 34.2/37.3 43.0/46.4 34.2/37.3 43.0/46.4
Compressor type Rotary Twin Rotary Twin Rotary Twin Rotary Twin Rotary Twin Rotary
Refrigerant type R410A R410A R32 R32 R32 R32
GWP 2088 2088 675 675 675 675
Refrigerant liquid pipe mm 2x6.35 2x6.35 2x6.35 2x6.35 2x6.35 2x6.35
Installation Refrigerant gas pipe mm 2x9.52 2x9.52 2x9.52 2x9.52 2x9.52 2x9.52
Total pipe length (Max) m 30 30 30 30 30 30
Single pipe length (Max) m 20 20 20 20 20 20
Max drop between I.U.&O.U m 15 15 15 15 15 15
Max drop between I.U.&I.U m 15 15 15 15 15 15
refrigerant load in factory kg 1.2 1.4 1.0 1.2 1.0 1.2
Maximum pipe length without charge refrigerant m 20 20 20 20 20 20
refrigerant charge quantity for extra length g/m 20 20 20 20 20 20
Cooling(Min-Max) °C -10~46 -10~46 -10~46 -10~46 -10~46 -10~46
Working temp
Heating(Min-Max) °C -15~24 -15~24 -15~24 -15~24 -15~24 -15~24

59 60
2U18FS2ERA(S) for Nebula/Brezza
Match Table Cooling
Combinations Rated capacity output(kW) Total cooling input(kW) Total power input(kW) Total current(A)@230V EER ENERGY SEER(W/W) ENERGY
Comb. Min Rated Max Min Rated Max Min Rated Max Rated
Unit A Unit B Unit C Unit A Unit B Unit C CLASS CLASS
data data data data data data data data data capacity

2U14CS4ERA for Nebula/Brezza


7 7 ---- 2.50 2.50 ---- 1.30 5.00 5.40 0.33 1.50 1.91 1.6 7.2 8.7 3.33 A 6.10 A++

7 9 ---- 2.20 2.80 ---- 1.30 5.00 5.40 0.33 1.50 1.91 1.6 7.2 8.7 3.33 A 6.10 A++

7 12 1.85 3.25 1.30 5.10 5.60 0.35 1.54 2.00 1.7 7.4 9.2 3.31 A 6.10 A++
1:2 ---- ----

Cooling 9 9 ---- 2.55 2.55 ---- 1.30 5.10 5.60 0.35 1.54 2.00 1.6 7.3 9.2 3.31 A 6.10 A++

Combinations Rated capacity output(kW) Total cooling input(kW) Total power input(kW) Total current(A)@230V EER SEER(W/W) 9 12 ---- 2.10 3.00 ---- 1.30 5.10 5.70 0.35 1.53 2.03 1.6 7.3 9.1 3.34 A 6.10 A++
ENERGY ENERGY
Comb. Min. Rated Max. Min. Rated Max. Min. Rated Max. Rated
Unit A Unit B Unit C Unit A Unit B Unit C CLASS CLASS 12 12 ---- 2.55 2.55 ---- 1.30 5.10 5.80 0.35 1.54 2.07 1.6 7.3 9.3 3.31 A 6.10 A++
data data data data data data data data data capacity
7 7 ---- 1.95 1.95 ---- 1.20 3.90 4.30 0.28 1.02 1.29 1.3 4.6 5.9 3.84 A 6.10 A++

7 9 ---- 1.70 2.20 ---- 1.20 3.90 4.30 0.29 1.02 1.32 1.4 4.6 6.0 3.84 A 6.10 A++
1:2 7 12 ---- 1.45 2.55 ---- 1.20 4.00 4.40 0.29 1.05 1.36 1.4 4.8 6.2 3.82 A 6.10 A++ Heating
9 9 ---- 2.00 2.00 ---- 1.20 4.00 4.40 0.29 1.05 1.36 1.4 4.8 6.2 3.82 A 6.10 A++ Combinations Rated capacity output(kW) Total cooling input(kW) Total power input(kW) Total current(A)@230V COP SCOP(W/W)
ENERGY ENERGY
Comb. Min Rated Max Min Rated Max Min Rated Max Rated
9 12 ---- 1.80 2.30 ---- 1.20 4.10 4.50 0.29 1.07 1.40 1.4 4.8 6.3 3.83 A 6.10 A++ Unit A Unit B Unit C Unit A Unit B Unit C CLASS CLASS
data data data data data data data data data capacity
7 7 ---- 2.80 2.80 ---- 1.60 5.60 6.20 0.41 1.53 2.25 1.9 7.3 10.3 3.65 A 4.00 A+
7 9 ---- 2.50 3.10 ---- 1.60 5.60 6.20 0.41 1.53 2.25 1.9 7.4 10.3 3.67 A 4.00 A+
Heating
7 12 ---- 2.10 3.70 ---- 1.70 5.80 6.40 0.42 1.57 2.25 2.0 7.8 10.3 3.70 A 4.00 A+
1:2
Combinations Rated capacity output(kW) Total cooling input(kW) Total power input(kW) Total current(A)@230V COP ENERGY SCOP(W/W) ENERGY 9 9 ---- 2.90 2.90 ---- 1.70 5.80 6.40 0.42 1.56 2.25 2.0 7.7 10.3 3.71 A 4.00 A+
Comb. Min. Rated Max. Min. Rated Max. Min. Rated Max. Rated
Unit A Unit B Unit C Unit A Unit B Unit C CLASS CLASS
data data data data data data data data data capacity 9 12 ---- 2.40 3.40 ---- 1.80 5.80 6.50 0.43 1.56 2.28 2.0 7.6 10.2 3.72 A 4.00 A+
7 7 ---- 2.10 2.10 ---- 1.50 4.20 4.60 0.34 1.09 1.56 1.6 5.0 7.1 3.87 A 4.00 A+ 12 12 ---- 2.90 2.90 ---- 1.90 5.80 6.60 0.45 1.55 2.30 2.1 7.6 10.3 3.74 A 4.00 A+
7 9 ---- 1.80 2.40 ---- 1.50 4.20 4.70 0.34 1.08 1.60 1.6 5.0 7.3 3.88 A 4.00 A+
1:2 7 12 ---- 1.60 2.80 ---- 1.50 4.40 4.80 0.34 1.12 1.60 1.6 5.1 7.3 3.92 A 4.00 A+

9 9 ---- 2.20 2.20 ---- 1.50 4.40 4.80 0.34 1.11 1.60 1.6 5.1 7.3 3.95 A 4.00 A+

9 12 ---- 2.00 2.40 ---- 1.50 4.40 5.00 0.34 1.09 1.65 1.6 4.9 7.4 4.03 A 4.00 A+

2U18FS2ERA(S) for Console


2U14CS4ERA for Console Cooling
Combinations Rated capacity output(kW) Total cooling input(kW) Total power input(kW) Total current(A)@230V EER ENERGY SEER(W/W) ENERGY
Cooling Comb.
Unit A Unit B Unit C Unit A Unit B Unit C Min. Rated Max. Min. Rated Max. Min. Rated Max. CLASS Rated
capacity
CLASS
data data data data data data data data data
Combinations Rated capacity output(kW) Total cooling input(kW) Total power input(kW) Total current(A)@230V EER ENERGY SEER(W/W) ENERGY
9 ---- 2.55 2.55 ---- 1.30 5.10 5.60 0.35 1.57 2.00 1.6 7.4 9.2 3.24 A 5.10 A
Comb. Min. Rated Max. Min. Rated Max. Min. Rated Max. Rated
Unit A Unit B Unit C Unit A Unit B Unit C data data data data data data data data data
CLASS
capacity
CLASS 1:2 9 12 ---- 2.10 3.00 ---- 1.30 5.10 5.70 0.35 1.58 2.03 1.6 7.5 9.1 3.23 A 5.10 A
9 9 ---- 2.00 2.00 ---- 1.20 4.00 4.40 0.29 1.10 1.36 1.4 5.0 6.2 3.63 A 5.10 A 12 12 ---- 2.55 2.55 ---- 1.30 5.10 5.80 0.35 1.55 2.07 1.6 7.5 9.3 3.28 A 5.10 A
1:2
9 12 ---- 1.80 2.30 ---- 1.20 4.10 4.50 0.29 1.07 1.40 1.4 4.8 6.3 3.83 A 5.10 A

Heating
Heating Combinations Rated capacity output(kW) Total cooling input(kW) Total power input(kW) Total current(A)@230V COP SCOP(W/W)
ENERGY ENERGY
Comb. Min. Rated Max. Min. Rated Max. Min. Rated Max. Rated
Combinations Rated capacity output(kW) Total cooling input(kW) Total power input(kW) Total current(A)@230V COP SCOP(W/W) Unit A Unit B Unit C Unit A Unit B Unit C CLASS CLASS
ENERGY ENERGY data data data data data data data data data capacity
Comb. Min. Rated Max. Min. Rated Max. Min. Rated Max. Rated
Unit A Unit B Unit C Unit A Unit B Unit C CLASS CLASS
data data data data data data data data data capacity 9 9 ---- 2.90 2.90 ---- 1.70 5.80 6.40 0.42 1.58 2.25 2.0 7.9 10.3 3.66 A 3.80 A
9 9 ---- 2.20 2.20 ---- 1.50 4.40 4.80 0.34 1.14 1.60 1.6 5.2 7.3 3.85 A 3.80 A 1:2 9 12 ---- 2.40 3.40 ---- 1.80 5.80 6.50 0.43 1.58 2.28 2.0 7.9 10.2 3.65 A 3.80 A
1:2
9 12 ---- 2.00 2.40 ---- 1.50 4.40 5.00 0.34 1.13 1.65 1.6 5.1 7.4 3.90 A 3.80 A 12 12 ---- 2.90 2.90 ---- 1.90 5.80 6.60 0.45 1.57 2.30 2.1 7.8 10.3 3.69 A 3.80 A

61 62
2U18FS2ERA(S) for Nebula/Brezza
Match Table Cooling
Combinations Rated capacity output(kW) Total cooling input(kW) Total power input(kW) Total current(A)@230V EER ENERGY SEER(W/W) ENERGY
Comb. Min Rated Max Min Rated Max Min Rated Max Rated
Unit A Unit B Unit C Unit A Unit B Unit C CLASS CLASS
data data data data data data data data data capacity

2U14CS4ERA for Nebula/Brezza


7 7 ---- 2.50 2.50 ---- 1.30 5.00 5.40 0.33 1.50 1.91 1.6 7.2 8.7 3.33 A 6.10 A++

7 9 ---- 2.20 2.80 ---- 1.30 5.00 5.40 0.33 1.50 1.91 1.6 7.2 8.7 3.33 A 6.10 A++

7 12 1.85 3.25 1.30 5.10 5.60 0.35 1.54 2.00 1.7 7.4 9.2 3.31 A 6.10 A++
1:2 ---- ----

Cooling 9 9 ---- 2.55 2.55 ---- 1.30 5.10 5.60 0.35 1.54 2.00 1.6 7.3 9.2 3.31 A 6.10 A++

Combinations Rated capacity output(kW) Total cooling input(kW) Total power input(kW) Total current(A)@230V EER SEER(W/W) 9 12 ---- 2.10 3.00 ---- 1.30 5.10 5.70 0.35 1.53 2.03 1.6 7.3 9.1 3.34 A 6.10 A++
ENERGY ENERGY
Comb. Min. Rated Max. Min. Rated Max. Min. Rated Max. Rated
Unit A Unit B Unit C Unit A Unit B Unit C CLASS CLASS 12 12 ---- 2.55 2.55 ---- 1.30 5.10 5.80 0.35 1.54 2.07 1.6 7.3 9.3 3.31 A 6.10 A++
data data data data data data data data data capacity
7 7 ---- 1.95 1.95 ---- 1.20 3.90 4.30 0.28 1.02 1.29 1.3 4.6 5.9 3.84 A 6.10 A++

7 9 ---- 1.70 2.20 ---- 1.20 3.90 4.30 0.29 1.02 1.32 1.4 4.6 6.0 3.84 A 6.10 A++
1:2 7 12 ---- 1.45 2.55 ---- 1.20 4.00 4.40 0.29 1.05 1.36 1.4 4.8 6.2 3.82 A 6.10 A++ Heating
9 9 ---- 2.00 2.00 ---- 1.20 4.00 4.40 0.29 1.05 1.36 1.4 4.8 6.2 3.82 A 6.10 A++ Combinations Rated capacity output(kW) Total cooling input(kW) Total power input(kW) Total current(A)@230V COP SCOP(W/W)
ENERGY ENERGY
Comb. Min Rated Max Min Rated Max Min Rated Max Rated
9 12 ---- 1.80 2.30 ---- 1.20 4.10 4.50 0.29 1.07 1.40 1.4 4.8 6.3 3.83 A 6.10 A++ Unit A Unit B Unit C Unit A Unit B Unit C CLASS CLASS
data data data data data data data data data capacity
7 7 ---- 2.80 2.80 ---- 1.60 5.60 6.20 0.41 1.53 2.25 1.9 7.3 10.3 3.65 A 4.00 A+
7 9 ---- 2.50 3.10 ---- 1.60 5.60 6.20 0.41 1.53 2.25 1.9 7.4 10.3 3.67 A 4.00 A+
Heating
7 12 ---- 2.10 3.70 ---- 1.70 5.80 6.40 0.42 1.57 2.25 2.0 7.8 10.3 3.70 A 4.00 A+
1:2
Combinations Rated capacity output(kW) Total cooling input(kW) Total power input(kW) Total current(A)@230V COP ENERGY SCOP(W/W) ENERGY 9 9 ---- 2.90 2.90 ---- 1.70 5.80 6.40 0.42 1.56 2.25 2.0 7.7 10.3 3.71 A 4.00 A+
Comb. Min. Rated Max. Min. Rated Max. Min. Rated Max. Rated
Unit A Unit B Unit C Unit A Unit B Unit C CLASS CLASS
data data data data data data data data data capacity 9 12 ---- 2.40 3.40 ---- 1.80 5.80 6.50 0.43 1.56 2.28 2.0 7.6 10.2 3.72 A 4.00 A+
7 7 ---- 2.10 2.10 ---- 1.50 4.20 4.60 0.34 1.09 1.56 1.6 5.0 7.1 3.87 A 4.00 A+ 12 12 ---- 2.90 2.90 ---- 1.90 5.80 6.60 0.45 1.55 2.30 2.1 7.6 10.3 3.74 A 4.00 A+
7 9 ---- 1.80 2.40 ---- 1.50 4.20 4.70 0.34 1.08 1.60 1.6 5.0 7.3 3.88 A 4.00 A+
1:2 7 12 ---- 1.60 2.80 ---- 1.50 4.40 4.80 0.34 1.12 1.60 1.6 5.1 7.3 3.92 A 4.00 A+

9 9 ---- 2.20 2.20 ---- 1.50 4.40 4.80 0.34 1.11 1.60 1.6 5.1 7.3 3.95 A 4.00 A+

9 12 ---- 2.00 2.40 ---- 1.50 4.40 5.00 0.34 1.09 1.65 1.6 4.9 7.4 4.03 A 4.00 A+

2U18FS2ERA(S) for Console


2U14CS4ERA for Console Cooling
Combinations Rated capacity output(kW) Total cooling input(kW) Total power input(kW) Total current(A)@230V EER ENERGY SEER(W/W) ENERGY
Cooling Comb.
Unit A Unit B Unit C Unit A Unit B Unit C Min. Rated Max. Min. Rated Max. Min. Rated Max. CLASS Rated
capacity
CLASS
data data data data data data data data data
Combinations Rated capacity output(kW) Total cooling input(kW) Total power input(kW) Total current(A)@230V EER ENERGY SEER(W/W) ENERGY
9 ---- 2.55 2.55 ---- 1.30 5.10 5.60 0.35 1.57 2.00 1.6 7.4 9.2 3.24 A 5.10 A
Comb. Min. Rated Max. Min. Rated Max. Min. Rated Max. Rated
Unit A Unit B Unit C Unit A Unit B Unit C data data data data data data data data data
CLASS
capacity
CLASS 1:2 9 12 ---- 2.10 3.00 ---- 1.30 5.10 5.70 0.35 1.58 2.03 1.6 7.5 9.1 3.23 A 5.10 A
9 9 ---- 2.00 2.00 ---- 1.20 4.00 4.40 0.29 1.10 1.36 1.4 5.0 6.2 3.63 A 5.10 A 12 12 ---- 2.55 2.55 ---- 1.30 5.10 5.80 0.35 1.55 2.07 1.6 7.5 9.3 3.28 A 5.10 A
1:2
9 12 ---- 1.80 2.30 ---- 1.20 4.10 4.50 0.29 1.07 1.40 1.4 4.8 6.3 3.83 A 5.10 A

Heating
Heating Combinations Rated capacity output(kW) Total cooling input(kW) Total power input(kW) Total current(A)@230V COP SCOP(W/W)
ENERGY ENERGY
Comb. Min. Rated Max. Min. Rated Max. Min. Rated Max. Rated
Combinations Rated capacity output(kW) Total cooling input(kW) Total power input(kW) Total current(A)@230V COP SCOP(W/W) Unit A Unit B Unit C Unit A Unit B Unit C CLASS CLASS
ENERGY ENERGY data data data data data data data data data capacity
Comb. Min. Rated Max. Min. Rated Max. Min. Rated Max. Rated
Unit A Unit B Unit C Unit A Unit B Unit C CLASS CLASS
data data data data data data data data data capacity 9 9 ---- 2.90 2.90 ---- 1.70 5.80 6.40 0.42 1.58 2.25 2.0 7.9 10.3 3.66 A 3.80 A
9 9 ---- 2.20 2.20 ---- 1.50 4.40 4.80 0.34 1.14 1.60 1.6 5.2 7.3 3.85 A 3.80 A 1:2 9 12 ---- 2.40 3.40 ---- 1.80 5.80 6.50 0.43 1.58 2.28 2.0 7.9 10.2 3.65 A 3.80 A
1:2
9 12 ---- 2.00 2.40 ---- 1.50 4.40 5.00 0.34 1.13 1.65 1.6 5.1 7.4 3.90 A 3.80 A 12 12 ---- 2.90 2.90 ---- 1.90 5.80 6.60 0.45 1.57 2.30 2.1 7.8 10.3 3.69 A 3.80 A

61 62
2U50S2SF1FA for Dawn
Match Table Cooling

Comb.
Unit A
Combinations

Unit B Unit C
Rated capacity output(kW) Total cooling input(kW)

Unit A Unit B Unit C Min. Rated Max.


Total power input(kW)
Min. Rated Max.
Total current(A)@230V
Min. Rated Max.
EER ENERGY
CLASS
SEER(W/W)
Rated
capacity
ENERGY
CLASS
data data data data data data data data data
20 20 ---- 2.45 2.45 ---- 1.30 4.90 5.60 0.33 1.36 2.27 1.6 6.1 10.2 3.60 A 6.50 A++
20 25 ---- 2.20 2.70 ---- 1.30 4.90 5.60 0.33 1.36 2.27 1.6 6.1 10.2 3.60 A 6.50 A++

2U40S2SC1FA for Dawn 1:2 20


25
35
25
----

----
2.00
2.50
3.00
2.50
----
----
1.30
1.30
5.00
5.00
5.80
5.80
0.35
0.35
1.41
1.41
2.33
2.33
1.7
1.6
6.3
6.3
10.6
10.4
3.55
3.55
A
A
6.50
6.50
A++
A++

Cooling
25 35 ---- 2.00 2.75 ---- 1.30 5.10 5.90 0.35 1.38 2.35 1.6 6.2 10.5 3.69 A 6.50 A++
35 35 ---- 2.55 2.55 ---- 1.30 5.10 6.00 0.38 1.41 2.40 1.6 6.3 10.7 3.62 A 6.50 A++
Combinations Rated capacity output(kW) Total cooling input(kW) Total power input(kW) Total current(A)@230V EER ENERGY SEER(W/W) ENERGY
Comb. Min. Rated Max. Min. Rated Max. Min. Rated Max. Rated
Unit A Unit B Unit C Unit A Unit B Unit C CLASS CLASS
data data data data data data data data data capacity Heating
20
0 20
0 ----
-- 19
1.90
1.9 1.9
1.90 ---- 1.10 3.80 4.60 0.29 0.94 1.47 1.2 4.3 6.7 4.04 A 6.20 A++
Combinations Rated capacity output(kW) Total cooling input(kW) Total power input(kW) Total current(A)@230V COP ENERGY SCOP(W/W) ENERGY
20 25 ---- 1 70
1.70
7 2.10 ---- 1.10 3.80 4.60 0.30 0.94 1.50 1.3 4.3 6.8 4.04 A 6.20 A++ Comb. Min. Rated Max. Min. Rated Max. Min. Rated Max. Rated
Unit A Unit B Unit C Unit A Unit B Unit C CLASS CLASS
1:2 20
20 35 ---- 1.45 2.45 ---- 1.10 3.90 4.70 0.30 0.97 1.54 1.3 4.5 7.0 4.02 A 6.20 A++ data data data data data data data data data capacity

25 25 ---- 1.95 1.95 ---- 1.10 3.90 4.70 0.30 0.97 1.54 1.3 4.5 7.0 4.02 A 6.20 A++ 20 20 ---- 2.75 2.75 ---- 1.50 5.50 6.30 0.49 1.51 2.37 2.2 6.8 10.9 3.64 A 4.00 A+

25 35 ---- 1.80 2.20 ---- 1.10 4.00 4.80 0.30 1.00 1.60 1.3 4.5 7.2 4.00 A 6.20 A++ 20 25 ---- 2.45 3.05 ---- 1.50 5.50 6.30 0.49 1.51 2.37 2.2 6.8 10.9 3.64 A 4.00 A+
1:2 20 35 ---- 2.15 3.45 ---- 1.60 5.60 6.40 0.52 1.53 2.37 2.3 6.9 10.9 3.66 A 4.00 A+
25 25 2.80 2.80 ---- 1.60 5.60 6.40 0.52 1.53 2.37 2.3 6.8 10.9 3.66 A 4.00 A+
Heating ----

25 35 ---- 2.60 3.10 ---- 1.70 5.70 6.50 0.53 1.55 2.40 2.4 7.0 10.6 3.67 A 4.00 A+
Combinations Rated capacity output(kW) Total cooling input(kW) Total power input(kW) Total current(A)@230V COP ENERGY SCOP(W/W) ENERGY 35 35 ---- 2.85 2.85 ---- 1.80 5.70 6.60 0.55 1.53 2.45 2.5 6.9 10.9 3.72 A 4.00 A+
Comb. Min. Rated Max. Min. Rated Max. Min. Rated Max. Rated
Unit A Unit B Unit C Unit A Unit B Unit C CLASS CLASS
data data data data data data data data data capacity
20 20 ---- 2.10 2.10 ---- 1.80 4.20 4.80 0.38 1.07 1.84 1.7 4.9 8.4 3.93 A 4.00 A+
20 25 ---- 1.80 2.40 ---- 1.80 4.20 4.90 0.38 1.06 1.88 1.7 4.9 8.6 3.96 A 4.00 A+

1:2 20 35 ---- 1.60 2.80 ---- 1.80 4.40 5.00 0.38 1.11 1.88 1.7 5.0 8.6 3.97 A 4.00 A+
25 25 ---- 2.20 2.20 ---- 1.80 4.40 5.00 0.38 1.09 1.88 1.7 5.0 8.6 4.03 A 4.00 A+ 2U50S2SF1FA for Flexis
25 35 ---- 2.00 2.40 ---- 1.80 4.40 5.20 0.38 1.07 1.95 1.7 4.8 8.7 4.10 A 4.00 A+
Cooling
Combinations Rated capacity output(kW) Total cooling input(kW) Total power input(kW) Total current(A)@230V EER ENERGY SEER(W/W) ENERGY
2U40S2SC1FA for Flexis Comb.
Unit A Unit B Unit C Unit A Unit B Unit C Min.
data
Rated
data
Max.
data
Min.
data
Rated
data
Max.
data
Min.
data
Rated
data
Max.
data
CLASS Rated
capacity
CLASS

20 20 ---- 2.45 2.45 ---- 1.30 4.90 5.60 0.33 1.35 2.26 1.6 6.0 10.1 3.63 A 6.50 A++
Cooling 20 25 ---- 2.20 2.70 ---- 1.30 4.90 5.60 0.33 1.36 2.27 1.6 6.1 10.2 3.60 A 6.50 A++
Combinations Rated capacity output(kW) Total cooling input(kW) Total power input(kW) Total current(A)@230V EER ENERGY SEER(W/W) ENERGY 1:2 20 35 ---- 2.00 3.00 ---- 1.30 5.00 5.80 0.35 1.43 2.33 1.7 6.3 10.6 3.50 A 6.50 A++
Comb. Min. Rated Max. Min. Rated Max. Min. Rated Max. Rated
Unit A Unit B Unit C Unit A Unit B Unit C CLASS CLASS 25 25 ---- 2.50 2.50 ---- 1.30 5.00 5.80 0.35 1.43 2.33 1.6 6.3 10.6 3.50 A 6.50 A++
data data data data data data data data data capacity
20 20 1.90 1.90 1.10 3.80 4.60 0.29 0.94 1.50 1.2 4.3 6.8 4.04 A 6.20 A++ 25 35 ---- 2.20 2.80 ---- 1.30 5.00 5.80 0.35 1.39 2.35 1.6 6.2 10.5 3.60 A 6.50 A++
---- ----
20 25 ---- 1.75 2.05 ---- 1.10 3.80 4.60 0.30 0.94 1.54 1.3 4.3 7.0 4.04 A 6.20 A++ 35 35 ---- 2.50 2.50 ---- 1.30 5.00 6.00 0.35 1.43 2.38 1.6 6.3 10.7 3.50 A 6.50 A++

1:2 20 35 ---- 1.55 2.35 ---- 1.10 3.90 4.70 0.30 0.97 1.57 1.3 4.5 7.1 4.03 A 6.20 A++
25 25 ---- 2.00 2.00 ---- 1.10 4.00 4.70 0.30 0.99 1.57 1.3 4.5 7.1 4.04 A 6.20 A++ Heating
25 35 ---- 2.00 2.00 ---- 1.10 4.00 4.80 0.30 1.02 1.65 1.3 4.5 7.4 3.92 A 6.20 A++ Combinations Rated capacity output(kW) Total cooling input(kW) Total power input(kW) Total current(A)@230V COP SCOP(W/W)
ENERGY ENERGY
Comb. Min. Rated Max. Min. Rated Max. Min. Rated Max. Rated
Unit A Unit B Unit C Unit A Unit B Unit C CLASS CLASS
data data data data data data data data data capacity
Heating 20 20 ---- 2.85 2.85 ---- 1.50 5.50 6.30 0.49 1.51 2.37 2.2 6.7 10.9 3.64 A 4.00 A+

Combinations Rated capacity output(kW) Total cooling input(kW) Total power input(kW) Total current(A)@230V COP ENERGY SCOP(W/W) ENERGY
20 25 ---- 2.55 3.15 ---- 1.50 5.50 6.30 0.49 1.52 2.37 2.2 6.8 10.9 3.62 A 4.00 A+
Comb.
Unit A Unit B Unit C Unit A Unit B Unit C Min. Rated Max. Min. Rated Max. Min. Rated Max. CLASS Rated
capacity
CLASS 1:2 20 35 ---- 2.20 3.50 ---- 1.60 5.70 6.40 0.52 1.57 2.38 2.3 7.0 10.9 3.63 A 4.00 A+
data data data data data data data data data
20 20 ---- 2.10 2.10 ---- 1.80 4.20 4.80 0.38 1.07 1.85 1.7 4.9 8.4 3.93 A 4.00 A+ 25 25 ---- 2.85 2.85 ---- 1.60 5.70 6.50 0.52 1.56 2.38 2.3 6.9 10.9 3.65 A 4.00 A+

20 25 ---- 1.90 1.90 ---- 1.80 4.20 4.90 0.38 1.06 1.88 1.7 4.9 8.6 3.96 A 4.00 A+ 25 35 ---- 2.55 3.15 ---- 1.70 5.70 6.60 0.53 1.56 2.40 2.4 6.9 10.6 3.65 A 4.00 A+

35 35 ---- 2.85 2.85 ---- 1.80 5.70 6.60 0.55 1.54 2.45 2.5 6.8 10.9 3.70 A 4.00 A+
1:2 20 35 ---- 1.80 1.80 ---- 1.80 4.40 5.00 0.38 1.12 1.88 1.7 5.1 8.6 3.93 A 4.00 A+
25 25 ---- 2.20 2.20 ---- 1.80 4.40 5.00 0.38 1.10 1.89 1.7 5.0 8.6 4.00 A 4.00 A+
25 35 ---- 2.00 2.00 ---- 1.80 4.40 5.20 0.38 1.08 1.95 1.7 4.8 8.7 4.07 A 4.00 A+

2U50S2SF1FA for Flare


2U40S2SC1FA for Flare Cooling
Combinations Rated capacity output(kW) Total cooling input(kW) Total power input(kW) Total current(A)@230V EER ENERGY SEER(W/W) ENERGY
Cooling Comb.
Unit A Unit B Unit C Unit A Unit B Unit C Min. Rated Max. Min. Rated Max. Min. Rated Max. CLASS Rated CLASS
data data data data data data data data data capacity
Combinations Rated capacity output(kW) Total cooling input(kW) Total power input(kW) Total current(A)@230V EER ENERGY SEER(W/W) ENERGY 20 20 ---- 2.45 2.45 ---- 1.30 4.90 5.60 0.33 1.35 2.26 1.6 6.0 10.1 3.63 A 6.50 A++
Comb. Min. Rated Max. Min. Rated Max. Min. Rated Max. Rated
Unit A Unit B Unit C Unit A Unit B Unit C CLASS CLASS
data data data data data data data data data capacity 20 25 ---- 2.20 2.70 ---- 1.30 4.90 5.60 0.33 1.36 2.27 1.6 6.1 10.2 3.60 A 6.50 A++
20 20 ---- 1.90 1.90 ---- 1.10 3.80 4.60 0.29 0.94 1.50 1.2 4.3 6.8 4.04 A 6.20 A++ 1:2 20 35 ---- 2.00 3.00 ---- 1.30 5.00 5.80 0.35 1.43 2.33 1.7 6.3 10.6 3.50 A 6.50 A++
20 25 ---- 1.75 2.05 ---- 1.10 3.80 4.60 0.30 0.94 1.54 1.3 4.3 7.0 4.04 A 6.20 A++ 25 25 ---- 2.50 2.50 ---- 1.30 5.00 5.80 0.35 1.43 2.33 1.6 6.3 10.6 3.50 A 6.50 A++
25 35 2.20 2.80 ---- 1.30 5.00 5.80 0.35 1.39 2.35 1.6 6.2 10.5 3.60 A 6.50 A++
1:2 20 35 ---- 1.55 2.35 ---- 1.10 3.90 4.70 0.30 0.97 1.57 1.3 4.5 7.1 4.03 A 6.20 A++ ----

25 25 ---- 2.00 2.00 ---- 1.10 4.00 4.70 0.30 0.99 1.57 1.3 4.5 7.1 4.04 A 6.20 A++ 35 35 ---- 2.50 2.50 ---- 1.30 5.00 6.00 0.35 1.43 2.38 1.6 6.3 10.7 3.50 A 6.50 A++
25 35 ---- 2.00 2.00 ---- 1.10 4.00 4.80 0.30 1.02 1.65 1.3 4.5 7.4 3.92 A 6.20 A++
Heating
Heating Combinations Rated capacity output(kW) Total cooling input(kW) Total power input(kW) Total current(A)@230V COP ENERGY SCOP(W/W) ENERGY
Comb. Min. Rated Max. Min. Rated Max. Min. Rated Max. Rated
Combinations Rated capacity output(kW) Total cooling input(kW) Total power input(kW) Total current(A)@230V COP SCOP(W/W) Unit A Unit B Unit C Unit A Unit B Unit C CLASS CLASS
ENERGY ENERGY data data data data data data data data data capacity
Comb. Min. Rated Max. Min. Rated Max. Min. Rated Max. Rated
Unit A Unit B Unit C Unit A Unit B Unit C CLASS CLASS
data data data data data data data data data capacity 20 20 ---- 2.85 2.85 ---- 1.50 5.50 6.30 0.49 1.51 2.37 2.2 6.7 10.9 3.64 A 4.00 A+
20 20 ---- 2.10 2.10 ---- 1.80 4.20 4.80 0.38 1.07 1.85 1.7 4.9 8.4 3.93 A 4.00 A+ 20 25 ---- 2.55 3.15 ---- 1.50 5.50 6.30 0.49 1.52 2.37 2.2 6.8 10.9 3.62 A 4.00 A+
20 25 ---- 1.90 2.30 ---- 1.80 4.20 4.90 0.38 1.06 1.88 1.7 4.9 8.6 3.96 A 4.00 A+ 1:2 20 35 ---- 2.20 3.50 ---- 1.60 5.70 6.40 0.52 1.57 2.38 2.3 7.0 10.9 3.63 A 4.00 A+
---- 25 25 2.85 2.85 ---- 1.60 5.70 6.50 0.52 1.56 2.38 2.3 6.9 10.9 3.65 A 4.00 A+
1:2 20 35 1.80 2.60 ---- 1.80 4.40 5.00 0.38 1.12 1.88 1.7 5.1 8.6 3.93 A 4.00 A+ ----

25 25 ---- 2.20 2.20 ---- 1.80 4.40 5.00 0.38 1.10 1.89 1.7 5.0 8.6 4.00 A 4.00 A+ 25 35 ---- 2.55 3.15 ---- 1.70 5.70 6.60 0.53 1.56 2.40 2.4 6.9 10.6 3.65 A 4.00 A+
25 35 ---- 2.00 2.40 ---- 1.80 4.40 5.20 0.38 1.08 1.95 1.7 4.8 8.7 4.07 A 4.00 A+ 35 35 ---- 2.85 2.85 ---- 1.80 5.70 6.60 0.55 1.54 2.45 2.5 6.8 10.9 3.70 A 4.00 A+

63 64
2U50S2SF1FA for Dawn
Match Table Cooling

Comb.
Unit A
Combinations

Unit B Unit C
Rated capacity output(kW) Total cooling input(kW)

Unit A Unit B Unit C Min. Rated Max.


Total power input(kW)
Min. Rated Max.
Total current(A)@230V
Min. Rated Max.
EER ENERGY
CLASS
SEER(W/W)
Rated
capacity
ENERGY
CLASS
data data data data data data data data data
20 20 ---- 2.45 2.45 ---- 1.30 4.90 5.60 0.33 1.36 2.27 1.6 6.1 10.2 3.60 A 6.50 A++
20 25 ---- 2.20 2.70 ---- 1.30 4.90 5.60 0.33 1.36 2.27 1.6 6.1 10.2 3.60 A 6.50 A++

2U40S2SC1FA for Dawn 1:2 20


25
35
25
----

----
2.00
2.50
3.00
2.50
----
----
1.30
1.30
5.00
5.00
5.80
5.80
0.35
0.35
1.41
1.41
2.33
2.33
1.7
1.6
6.3
6.3
10.6
10.4
3.55
3.55
A
A
6.50
6.50
A++
A++

Cooling
25 35 ---- 2.00 2.75 ---- 1.30 5.10 5.90 0.35 1.38 2.35 1.6 6.2 10.5 3.69 A 6.50 A++
35 35 ---- 2.55 2.55 ---- 1.30 5.10 6.00 0.38 1.41 2.40 1.6 6.3 10.7 3.62 A 6.50 A++
Combinations Rated capacity output(kW) Total cooling input(kW) Total power input(kW) Total current(A)@230V EER ENERGY SEER(W/W) ENERGY
Comb. Min. Rated Max. Min. Rated Max. Min. Rated Max. Rated
Unit A Unit B Unit C Unit A Unit B Unit C CLASS CLASS
data data data data data data data data data capacity Heating
20
0 20
0 ----
-- 19
1.90
1.9 1.9
1.90 ---- 1.10 3.80 4.60 0.29 0.94 1.47 1.2 4.3 6.7 4.04 A 6.20 A++
Combinations Rated capacity output(kW) Total cooling input(kW) Total power input(kW) Total current(A)@230V COP ENERGY SCOP(W/W) ENERGY
20 25 ---- 1 70
1.70
7 2.10 ---- 1.10 3.80 4.60 0.30 0.94 1.50 1.3 4.3 6.8 4.04 A 6.20 A++ Comb. Min. Rated Max. Min. Rated Max. Min. Rated Max. Rated
Unit A Unit B Unit C Unit A Unit B Unit C CLASS CLASS
1:2 20
20 35 ---- 1.45 2.45 ---- 1.10 3.90 4.70 0.30 0.97 1.54 1.3 4.5 7.0 4.02 A 6.20 A++ data data data data data data data data data capacity

25 25 ---- 1.95 1.95 ---- 1.10 3.90 4.70 0.30 0.97 1.54 1.3 4.5 7.0 4.02 A 6.20 A++ 20 20 ---- 2.75 2.75 ---- 1.50 5.50 6.30 0.49 1.51 2.37 2.2 6.8 10.9 3.64 A 4.00 A+

25 35 ---- 1.80 2.20 ---- 1.10 4.00 4.80 0.30 1.00 1.60 1.3 4.5 7.2 4.00 A 6.20 A++ 20 25 ---- 2.45 3.05 ---- 1.50 5.50 6.30 0.49 1.51 2.37 2.2 6.8 10.9 3.64 A 4.00 A+
1:2 20 35 ---- 2.15 3.45 ---- 1.60 5.60 6.40 0.52 1.53 2.37 2.3 6.9 10.9 3.66 A 4.00 A+
25 25 2.80 2.80 ---- 1.60 5.60 6.40 0.52 1.53 2.37 2.3 6.8 10.9 3.66 A 4.00 A+
Heating ----

25 35 ---- 2.60 3.10 ---- 1.70 5.70 6.50 0.53 1.55 2.40 2.4 7.0 10.6 3.67 A 4.00 A+
Combinations Rated capacity output(kW) Total cooling input(kW) Total power input(kW) Total current(A)@230V COP ENERGY SCOP(W/W) ENERGY 35 35 ---- 2.85 2.85 ---- 1.80 5.70 6.60 0.55 1.53 2.45 2.5 6.9 10.9 3.72 A 4.00 A+
Comb. Min. Rated Max. Min. Rated Max. Min. Rated Max. Rated
Unit A Unit B Unit C Unit A Unit B Unit C CLASS CLASS
data data data data data data data data data capacity
20 20 ---- 2.10 2.10 ---- 1.80 4.20 4.80 0.38 1.07 1.84 1.7 4.9 8.4 3.93 A 4.00 A+
20 25 ---- 1.80 2.40 ---- 1.80 4.20 4.90 0.38 1.06 1.88 1.7 4.9 8.6 3.96 A 4.00 A+

1:2 20 35 ---- 1.60 2.80 ---- 1.80 4.40 5.00 0.38 1.11 1.88 1.7 5.0 8.6 3.97 A 4.00 A+
25 25 ---- 2.20 2.20 ---- 1.80 4.40 5.00 0.38 1.09 1.88 1.7 5.0 8.6 4.03 A 4.00 A+ 2U50S2SF1FA for Flexis
25 35 ---- 2.00 2.40 ---- 1.80 4.40 5.20 0.38 1.07 1.95 1.7 4.8 8.7 4.10 A 4.00 A+
Cooling
Combinations Rated capacity output(kW) Total cooling input(kW) Total power input(kW) Total current(A)@230V EER ENERGY SEER(W/W) ENERGY
2U40S2SC1FA for Flexis Comb.
Unit A Unit B Unit C Unit A Unit B Unit C Min.
data
Rated
data
Max.
data
Min.
data
Rated
data
Max.
data
Min.
data
Rated
data
Max.
data
CLASS Rated
capacity
CLASS

20 20 ---- 2.45 2.45 ---- 1.30 4.90 5.60 0.33 1.35 2.26 1.6 6.0 10.1 3.63 A 6.50 A++
Cooling 20 25 ---- 2.20 2.70 ---- 1.30 4.90 5.60 0.33 1.36 2.27 1.6 6.1 10.2 3.60 A 6.50 A++
Combinations Rated capacity output(kW) Total cooling input(kW) Total power input(kW) Total current(A)@230V EER ENERGY SEER(W/W) ENERGY 1:2 20 35 ---- 2.00 3.00 ---- 1.30 5.00 5.80 0.35 1.43 2.33 1.7 6.3 10.6 3.50 A 6.50 A++
Comb. Min. Rated Max. Min. Rated Max. Min. Rated Max. Rated
Unit A Unit B Unit C Unit A Unit B Unit C CLASS CLASS 25 25 ---- 2.50 2.50 ---- 1.30 5.00 5.80 0.35 1.43 2.33 1.6 6.3 10.6 3.50 A 6.50 A++
data data data data data data data data data capacity
20 20 1.90 1.90 1.10 3.80 4.60 0.29 0.94 1.50 1.2 4.3 6.8 4.04 A 6.20 A++ 25 35 ---- 2.20 2.80 ---- 1.30 5.00 5.80 0.35 1.39 2.35 1.6 6.2 10.5 3.60 A 6.50 A++
---- ----
20 25 ---- 1.75 2.05 ---- 1.10 3.80 4.60 0.30 0.94 1.54 1.3 4.3 7.0 4.04 A 6.20 A++ 35 35 ---- 2.50 2.50 ---- 1.30 5.00 6.00 0.35 1.43 2.38 1.6 6.3 10.7 3.50 A 6.50 A++

1:2 20 35 ---- 1.55 2.35 ---- 1.10 3.90 4.70 0.30 0.97 1.57 1.3 4.5 7.1 4.03 A 6.20 A++
25 25 ---- 2.00 2.00 ---- 1.10 4.00 4.70 0.30 0.99 1.57 1.3 4.5 7.1 4.04 A 6.20 A++ Heating
25 35 ---- 2.00 2.00 ---- 1.10 4.00 4.80 0.30 1.02 1.65 1.3 4.5 7.4 3.92 A 6.20 A++ Combinations Rated capacity output(kW) Total cooling input(kW) Total power input(kW) Total current(A)@230V COP SCOP(W/W)
ENERGY ENERGY
Comb. Min. Rated Max. Min. Rated Max. Min. Rated Max. Rated
Unit A Unit B Unit C Unit A Unit B Unit C CLASS CLASS
data data data data data data data data data capacity
Heating 20 20 ---- 2.85 2.85 ---- 1.50 5.50 6.30 0.49 1.51 2.37 2.2 6.7 10.9 3.64 A 4.00 A+

Combinations Rated capacity output(kW) Total cooling input(kW) Total power input(kW) Total current(A)@230V COP ENERGY SCOP(W/W) ENERGY
20 25 ---- 2.55 3.15 ---- 1.50 5.50 6.30 0.49 1.52 2.37 2.2 6.8 10.9 3.62 A 4.00 A+
Comb.
Unit A Unit B Unit C Unit A Unit B Unit C Min. Rated Max. Min. Rated Max. Min. Rated Max. CLASS Rated
capacity
CLASS 1:2 20 35 ---- 2.20 3.50 ---- 1.60 5.70 6.40 0.52 1.57 2.38 2.3 7.0 10.9 3.63 A 4.00 A+
data data data data data data data data data
20 20 ---- 2.10 2.10 ---- 1.80 4.20 4.80 0.38 1.07 1.85 1.7 4.9 8.4 3.93 A 4.00 A+ 25 25 ---- 2.85 2.85 ---- 1.60 5.70 6.50 0.52 1.56 2.38 2.3 6.9 10.9 3.65 A 4.00 A+

20 25 ---- 1.90 1.90 ---- 1.80 4.20 4.90 0.38 1.06 1.88 1.7 4.9 8.6 3.96 A 4.00 A+ 25 35 ---- 2.55 3.15 ---- 1.70 5.70 6.60 0.53 1.56 2.40 2.4 6.9 10.6 3.65 A 4.00 A+

35 35 ---- 2.85 2.85 ---- 1.80 5.70 6.60 0.55 1.54 2.45 2.5 6.8 10.9 3.70 A 4.00 A+
1:2 20 35 ---- 1.80 1.80 ---- 1.80 4.40 5.00 0.38 1.12 1.88 1.7 5.1 8.6 3.93 A 4.00 A+
25 25 ---- 2.20 2.20 ---- 1.80 4.40 5.00 0.38 1.10 1.89 1.7 5.0 8.6 4.00 A 4.00 A+
25 35 ---- 2.00 2.00 ---- 1.80 4.40 5.20 0.38 1.08 1.95 1.7 4.8 8.7 4.07 A 4.00 A+

2U50S2SF1FA for Flare


2U40S2SC1FA for Flare Cooling
Combinations Rated capacity output(kW) Total cooling input(kW) Total power input(kW) Total current(A)@230V EER ENERGY SEER(W/W) ENERGY
Cooling Comb.
Unit A Unit B Unit C Unit A Unit B Unit C Min. Rated Max. Min. Rated Max. Min. Rated Max. CLASS Rated CLASS
data data data data data data data data data capacity
Combinations Rated capacity output(kW) Total cooling input(kW) Total power input(kW) Total current(A)@230V EER ENERGY SEER(W/W) ENERGY 20 20 ---- 2.45 2.45 ---- 1.30 4.90 5.60 0.33 1.35 2.26 1.6 6.0 10.1 3.63 A 6.50 A++
Comb. Min. Rated Max. Min. Rated Max. Min. Rated Max. Rated
Unit A Unit B Unit C Unit A Unit B Unit C CLASS CLASS
data data data data data data data data data capacity 20 25 ---- 2.20 2.70 ---- 1.30 4.90 5.60 0.33 1.36 2.27 1.6 6.1 10.2 3.60 A 6.50 A++
20 20 ---- 1.90 1.90 ---- 1.10 3.80 4.60 0.29 0.94 1.50 1.2 4.3 6.8 4.04 A 6.20 A++ 1:2 20 35 ---- 2.00 3.00 ---- 1.30 5.00 5.80 0.35 1.43 2.33 1.7 6.3 10.6 3.50 A 6.50 A++
20 25 ---- 1.75 2.05 ---- 1.10 3.80 4.60 0.30 0.94 1.54 1.3 4.3 7.0 4.04 A 6.20 A++ 25 25 ---- 2.50 2.50 ---- 1.30 5.00 5.80 0.35 1.43 2.33 1.6 6.3 10.6 3.50 A 6.50 A++
25 35 2.20 2.80 ---- 1.30 5.00 5.80 0.35 1.39 2.35 1.6 6.2 10.5 3.60 A 6.50 A++
1:2 20 35 ---- 1.55 2.35 ---- 1.10 3.90 4.70 0.30 0.97 1.57 1.3 4.5 7.1 4.03 A 6.20 A++ ----

25 25 ---- 2.00 2.00 ---- 1.10 4.00 4.70 0.30 0.99 1.57 1.3 4.5 7.1 4.04 A 6.20 A++ 35 35 ---- 2.50 2.50 ---- 1.30 5.00 6.00 0.35 1.43 2.38 1.6 6.3 10.7 3.50 A 6.50 A++
25 35 ---- 2.00 2.00 ---- 1.10 4.00 4.80 0.30 1.02 1.65 1.3 4.5 7.4 3.92 A 6.20 A++
Heating
Heating Combinations Rated capacity output(kW) Total cooling input(kW) Total power input(kW) Total current(A)@230V COP ENERGY SCOP(W/W) ENERGY
Comb. Min. Rated Max. Min. Rated Max. Min. Rated Max. Rated
Combinations Rated capacity output(kW) Total cooling input(kW) Total power input(kW) Total current(A)@230V COP SCOP(W/W) Unit A Unit B Unit C Unit A Unit B Unit C CLASS CLASS
ENERGY ENERGY data data data data data data data data data capacity
Comb. Min. Rated Max. Min. Rated Max. Min. Rated Max. Rated
Unit A Unit B Unit C Unit A Unit B Unit C CLASS CLASS
data data data data data data data data data capacity 20 20 ---- 2.85 2.85 ---- 1.50 5.50 6.30 0.49 1.51 2.37 2.2 6.7 10.9 3.64 A 4.00 A+
20 20 ---- 2.10 2.10 ---- 1.80 4.20 4.80 0.38 1.07 1.85 1.7 4.9 8.4 3.93 A 4.00 A+ 20 25 ---- 2.55 3.15 ---- 1.50 5.50 6.30 0.49 1.52 2.37 2.2 6.8 10.9 3.62 A 4.00 A+
20 25 ---- 1.90 2.30 ---- 1.80 4.20 4.90 0.38 1.06 1.88 1.7 4.9 8.6 3.96 A 4.00 A+ 1:2 20 35 ---- 2.20 3.50 ---- 1.60 5.70 6.40 0.52 1.57 2.38 2.3 7.0 10.9 3.63 A 4.00 A+
---- 25 25 2.85 2.85 ---- 1.60 5.70 6.50 0.52 1.56 2.38 2.3 6.9 10.9 3.65 A 4.00 A+
1:2 20 35 1.80 2.60 ---- 1.80 4.40 5.00 0.38 1.12 1.88 1.7 5.1 8.6 3.93 A 4.00 A+ ----

25 25 ---- 2.20 2.20 ---- 1.80 4.40 5.00 0.38 1.10 1.89 1.7 5.0 8.6 4.00 A 4.00 A+ 25 35 ---- 2.55 3.15 ---- 1.70 5.70 6.60 0.53 1.56 2.40 2.4 6.9 10.6 3.65 A 4.00 A+
25 35 ---- 2.00 2.40 ---- 1.80 4.40 5.20 0.38 1.08 1.95 1.7 4.8 8.7 4.07 A 4.00 A+ 35 35 ---- 2.85 2.85 ---- 1.80 5.70 6.60 0.55 1.54 2.45 2.5 6.8 10.9 3.70 A 4.00 A+

63 64
Key Features

Carpet Airflow Whispering Air -15°C Heating -10°C Cooling A-PAM Comfortable Sleep Super Match
Inverter Control

Console AF09AS1ERA

AF12AS1ERA
A/A
Carpet Airflow Brings Comfort Heating Outdoor Remote Controller

Indoor AF09AS1ERA AF12AS1ERA


Outdoor 1U09BS3ERA 1U12BS3ERA
Nominal (Min.~Max.) Btu/h 8530(4430-10240) 11940(4780-13640)
Cooling Capacity
Nominal (Min.~Max.) kW 2.5(1.3-3.0) 3.5(1.4-4.0)
Energy efficiency(average climate) SEER/EER Energy Saving 5.30/3.30 5.30/3.20

Carpet Airflow
Energy class - Cooling A A
Cooling Pdesign capacity(35°C) kW 2.5 3.4
Power input - Cooling Nominal (Min.~Max.) kW 0.75(0.35-1.30) 1.10(0.37-1.55)
Annual energy consumption - Cooling kWh/a 165 224

The special designed function for console type make the possibility of airflow blowing along with the floor level,so Nominal (Min.~Max.) Btu/h 9560(4780-10920) 12970(4780-13990)
Heating @ -7ºC Btu/h 7500 9000
provide the extreme comfort like warm carpet especially in the winter bed room. Heating Capacity
Nominal (Min.~Max.) kW 2.8(1.4-3.2) 3.8(1.4-4.1)
Heating @ -7ºC kW 2.2 2.6
SCOP/COP(Average climate) Energy Saving 3.80/3.70 3.80/3.40
Energy efficiency
SCOP(Warm/Cold climate) 4.80/- 4.80/-

Easy select the air outlet way by manual switch Energy class - Heating
Heating Pdesign capacity (-10°C)
Average/warm/cold
kW
A/A++/-
2.5
A/A++/-
3
Power input - Heating Nominal (Min.~Max.) kW 0.76(0.33-1.30) 1.11(0.38-1.55)
Annual energy consumption - Heating kWh/a 1005 1360
upward position This setting blows air from upper outlet only.
Air outlet Operating limits (cooling) Min.~Max. ºC "21-35ºC(in)/-10-43ºC(out)" "21-35ºC(in)/-10-43ºCout)"

selection Operating limits (heating) Min.~Max. ºC "10-27ºC(in)/-15-24ºC(out)" "10-27ºC(in)/-15-24ºC(out)"

switch
Power supply Ph/V/Hz 1/230/50 1/230/50
This setting automatically decides a blow pattern depending on mode and
downward position Power supply (position) outdoor outdoor
conditions. 40H FCL (set) *just for reference 182 182
Indoor
Net dimension W/D/H mm 720/253/640 720/253/640
Package dimension W/D/H mm 787/307/722 787/307/722
Net/Shipping weight
Automatic carpet airflow control programm
kg 17/19.5 17.5/20
Air flow(cooling/heating) Max. m³/h 550 650
Cooling (Hi) dB 53 55
Sound power level
When the air outlet selection switch is at downward position,the unit can realize Heating (Hi) dB 54 56

carpet airflow under below conditions: Sound pressure level


Cooling (Hi/Mid/Lo/So) dB(A) 41/39/34/29 42/40/37/31
Heating (Hi/Mid/Lo/So) dB(A) 42/40/35/30 43/41/38/32
Moisture removal 10¯³m³/h 1.2 1.6
Outdoor
Compressor Panasonic Panasonic
Net dimension W/D/H mm 780/245/540 780/245/540
Package dimension W/D/H mm 920/351/620 920/351/620
Net/Shipping weight kg 28.4/31.4 30.4/33.4
In heating mode, when room temp. is reaching Air flow(cooling/heating) Max. m³/h 1900 1900
setting temp. the unit will blow both upward Sound power level Hi dB 61/62 62/63
Sound pressure level Hi dB(A) 51/52 52/53
and downward. Running current Max. A 5.7 7.1
Refrigerant type R410A/R32 R410A R410A
In cooling mode,when the unit just start or
Refrigerant charge R410A/R32 g 750 1000
there is big gap between room temp. and Liquid side diameter mm / inch 6.35 6.35
setting temp.,the unit will blow both upward Gas side diameter mm / inch 9.52 9.52

and downward. Refrigerant pipe Max. pipe length/height m 15/10 15/10


Max. pipe length without additional charge m 7 7
additional charge g/m 20 20

Rating Conditions: Cooling Indoor 27ºC DB / 19ºC WB. Cooling Outdoor 35ºC DB / 24ºC WB. Heating Indoor 20ºC DB. Heating Outdoor 7ºC DB / 6ºC WB.(DB: Dry Bulb; WB: Wet Bulb)
For detailed information about ERP, please visit our page http://www.haier.com/ecodesign.

65 66
Key Features

Carpet Airflow Whispering Air -15°C Heating -10°C Cooling A-PAM Comfortable Sleep Super Match
Inverter Control

Console AF09AS1ERA

AF12AS1ERA
A/A
Carpet Airflow Brings Comfort Heating Outdoor Remote Controller

Indoor AF09AS1ERA AF12AS1ERA


Outdoor 1U09BS3ERA 1U12BS3ERA
Nominal (Min.~Max.) Btu/h 8530(4430-10240) 11940(4780-13640)
Cooling Capacity
Nominal (Min.~Max.) kW 2.5(1.3-3.0) 3.5(1.4-4.0)
Energy efficiency(average climate) SEER/EER Energy Saving 5.30/3.30 5.30/3.20

Carpet Airflow
Energy class - Cooling A A
Cooling Pdesign capacity(35°C) kW 2.5 3.4
Power input - Cooling Nominal (Min.~Max.) kW 0.75(0.35-1.30) 1.10(0.37-1.55)
Annual energy consumption - Cooling kWh/a 165 224

The special designed function for console type make the possibility of airflow blowing along with the floor level,so Nominal (Min.~Max.) Btu/h 9560(4780-10920) 12970(4780-13990)
Heating @ -7ºC Btu/h 7500 9000
provide the extreme comfort like warm carpet especially in the winter bed room. Heating Capacity
Nominal (Min.~Max.) kW 2.8(1.4-3.2) 3.8(1.4-4.1)
Heating @ -7ºC kW 2.2 2.6
SCOP/COP(Average climate) Energy Saving 3.80/3.70 3.80/3.40
Energy efficiency
SCOP(Warm/Cold climate) 4.80/- 4.80/-

Easy select the air outlet way by manual switch Energy class - Heating
Heating Pdesign capacity (-10°C)
Average/warm/cold
kW
A/A++/-
2.5
A/A++/-
3
Power input - Heating Nominal (Min.~Max.) kW 0.76(0.33-1.30) 1.11(0.38-1.55)
Annual energy consumption - Heating kWh/a 1005 1360
upward position This setting blows air from upper outlet only.
Air outlet Operating limits (cooling) Min.~Max. ºC "21-35ºC(in)/-10-43ºC(out)" "21-35ºC(in)/-10-43ºCout)"

selection Operating limits (heating) Min.~Max. ºC "10-27ºC(in)/-15-24ºC(out)" "10-27ºC(in)/-15-24ºC(out)"

switch
Power supply Ph/V/Hz 1/230/50 1/230/50
This setting automatically decides a blow pattern depending on mode and
downward position Power supply (position) outdoor outdoor
conditions. 40H FCL (set) *just for reference 182 182
Indoor
Net dimension W/D/H mm 720/253/640 720/253/640
Package dimension W/D/H mm 787/307/722 787/307/722
Net/Shipping weight
Automatic carpet airflow control programm
kg 17/19.5 17.5/20
Air flow(cooling/heating) Max. m³/h 550 650
Cooling (Hi) dB 53 55
Sound power level
When the air outlet selection switch is at downward position,the unit can realize Heating (Hi) dB 54 56

carpet airflow under below conditions: Sound pressure level


Cooling (Hi/Mid/Lo/So) dB(A) 41/39/34/29 42/40/37/31
Heating (Hi/Mid/Lo/So) dB(A) 42/40/35/30 43/41/38/32
Moisture removal 10¯³m³/h 1.2 1.6
Outdoor
Compressor Panasonic Panasonic
Net dimension W/D/H mm 780/245/540 780/245/540
Package dimension W/D/H mm 920/351/620 920/351/620
Net/Shipping weight kg 28.4/31.4 30.4/33.4
In heating mode, when room temp. is reaching Air flow(cooling/heating) Max. m³/h 1900 1900
setting temp. the unit will blow both upward Sound power level Hi dB 61/62 62/63
Sound pressure level Hi dB(A) 51/52 52/53
and downward. Running current Max. A 5.7 7.1
Refrigerant type R410A/R32 R410A R410A
In cooling mode,when the unit just start or
Refrigerant charge R410A/R32 g 750 1000
there is big gap between room temp. and Liquid side diameter mm / inch 6.35 6.35
setting temp.,the unit will blow both upward Gas side diameter mm / inch 9.52 9.52

and downward. Refrigerant pipe Max. pipe length/height m 15/10 15/10


Max. pipe length without additional charge m 7 7
additional charge g/m 20 20

Rating Conditions: Cooling Indoor 27ºC DB / 19ºC WB. Cooling Outdoor 35ºC DB / 24ºC WB. Heating Indoor 20ºC DB. Heating Outdoor 7ºC DB / 6ºC WB.(DB: Dry Bulb; WB: Wet Bulb)
For detailed information about ERP, please visit our page http://www.haier.com/ecodesign.

65 66
953mm

Cabinet
Super Long vertical blowing cabinet design suplying Quick comfort for Big space
953mm

Cabinet
Super Long vertical blowing cabinet design suplying Quick comfort for Big space
Key Features Features

• -15°C Heating
• -10°C Cooling
26
dB(A) • 10°C Heating Maintenance
• Comfortable Sleep
Wi-Fi Control Whispering Air Vertical Airflow Comfortable 3D Airflow
• Electrical Deicer
Sleep
• Auto Horizontal Airflow (Two Motors)

Cabinet
A++/A+
AP24DF1HRA Outdoor Remote Controller
Enjoy long distance airflow with full comfort

Indoor AP24DF1HRA
Model Outdoor 1U24SE3ERA
Nominal (Min.~Max.) Btu/h 24580(3072-30374)
Cooling Capacity
Nominal (Min.~Max.) kW 7.2(0.9-8.9)
Energy efficiency(average climate) SEER/EER Energy Saving 7.06/3.50
Energy class - Cooling A++
Cooling Pdesign capacity(35°C) kW 7.2
Power input - Cooling Nominal (Min.~Max.) kW 2.06(0.31-2.8)

Wi-Fi Control Annual energy consumption - Cooling


Nominal (Min.~Max.)
kWh/a
Btu/h
357
30715(3072-35834)
Heating @ -7°C Btu/h 16620
Heating Capacity
Nominal (Min.~Max.) kW 9.0(0.9-10.5)
Control your air conditioning system with smart phone or tablet, Heating @ -7°C kW 4.87
which can connect internet. SCOP/COP(Average climate) Energy Saving 4.05/3.29
Energy efficiency
SCOP(Warm/Cold climate) 4.71/-
Energy class - Heating Average/warm/cold A+/A++/-
Heating Pdesign capacity (-10°C) kW 5.5
Power input - Heating Nominal (Min.~Max.) kW 2.73(0.49-3.182)
Annual energy consumption - Heating kWh/a 1903
Operating limits (cooling) Min.~Max. °C 21-35°C(in)/-10-43°C(out)
Operating limits (heating) Min.~Max. °C 10-27°C(in)/-15-24°C(out)
Power supply Ph/V/Hz 1/230/50
Power supply (position) outdoor
40H FCL (set) *just for reference 54
Indoor
Net dimension W/D/H mm 377/407/1810
26
dB(A) Whispering Air Package dimension
Net/Shipping weight
W/D/H mm
kg
525/555/1935
34/45
20dB(A) Air flow(cooling/heating) Max. m/h 1200

26
Cooling (Hi) dB 60
Optimize the noise control technology, such as the compressor Sound power level
Heating (Hi) dB 60
frequency adjustment, fan speed control and air flue design Cooling (Hi/Mid/Lo/So) dB(A) 42/37/34/26
Sound pressure level
decreasing the noise level even lowest to 26dB(A) with the dB(A) Heating (Hi/Mid/Lo/So) dB(A) 42/37/34/26
Moisture removal
specialized QUIET setting. (refer to 24k) 10¯m/h 4.25
Outdoor
Compressor Mitsubishi
Net dimension W/D/H mm 920/385/762
Package dimension W/D/H mm 1085/487/843
Net/Shipping weight kg 55/61
Air flow(cooling/heating) Max. m³/h 2500
Sound power level Hi dB 69
Sound pressure level Hi dB(A) 56

Vertical Airflow
Running current Max. A 14.3
Refrigerant type R410A/R32 R410A
Refrigerant charge R410A/R32 g 1950
Liquid side diameter mm / inch 6.35
Super long vertical blowing cabinet design, supplying fast comfort Gas side diameter mm / inch 12.7

for big space. Refrigerant pipe Max. pipe length/height m 25/15


Max. pipe length without additional charge m 10
additional charge g/m 20

Rating Conditions: Cooling Indoor 27°C DB / 19°C WB. Cooling Outdoor 35°C DB / 24°C WB. Heating Indoor 20°C DB. Heating Outdoor 7°C DB / 6°C WB.(DB: Dry Bulb; WB: Wet Bulb)
For detailed information about ERP, please visit our page http://www.haier.com/ecodesign.

69 70
Key Features Features

• -15°C Heating
• -10°C Cooling
26
dB(A) • 10°C Heating Maintenance
• Comfortable Sleep
Wi-Fi Control Whispering Air Vertical Airflow Comfortable 3D Airflow
• Electrical Deicer
Sleep
• Auto Horizontal Airflow (Two Motors)

Cabinet
A++/A+
AP24DF1HRA Outdoor Remote Controller
Enjoy long distance airflow with full comfort

Indoor AP24DF1HRA
Model Outdoor 1U24SE3ERA
Nominal (Min.~Max.) Btu/h 24580(3072-30374)
Cooling Capacity
Nominal (Min.~Max.) kW 7.2(0.9-8.9)
Energy efficiency(average climate) SEER/EER Energy Saving 7.06/3.50
Energy class - Cooling A++
Cooling Pdesign capacity(35°C) kW 7.2
Power input - Cooling Nominal (Min.~Max.) kW 2.06(0.31-2.8)

Wi-Fi Control Annual energy consumption - Cooling


Nominal (Min.~Max.)
kWh/a
Btu/h
357
30715(3072-35834)
Heating @ -7°C Btu/h 16620
Heating Capacity
Nominal (Min.~Max.) kW 9.0(0.9-10.5)
Control your air conditioning system with smart phone or tablet, Heating @ -7°C kW 4.87
which can connect internet. SCOP/COP(Average climate) Energy Saving 4.05/3.29
Energy efficiency
SCOP(Warm/Cold climate) 4.71/-
Energy class - Heating Average/warm/cold A+/A++/-
Heating Pdesign capacity (-10°C) kW 5.5
Power input - Heating Nominal (Min.~Max.) kW 2.73(0.49-3.182)
Annual energy consumption - Heating kWh/a 1903
Operating limits (cooling) Min.~Max. °C 21-35°C(in)/-10-43°C(out)
Operating limits (heating) Min.~Max. °C 10-27°C(in)/-15-24°C(out)
Power supply Ph/V/Hz 1/230/50
Power supply (position) outdoor
40H FCL (set) *just for reference 54
Indoor
Net dimension W/D/H mm 377/407/1810
26
dB(A) Whispering Air Package dimension
Net/Shipping weight
W/D/H mm
kg
525/555/1935
34/45
20dB(A) Air flow(cooling/heating) Max. m/h 1200

26
Cooling (Hi) dB 60
Optimize the noise control technology, such as the compressor Sound power level
Heating (Hi) dB 60
frequency adjustment, fan speed control and air flue design Cooling (Hi/Mid/Lo/So) dB(A) 42/37/34/26
Sound pressure level
decreasing the noise level even lowest to 26dB(A) with the dB(A) Heating (Hi/Mid/Lo/So) dB(A) 42/37/34/26
Moisture removal
specialized QUIET setting. (refer to 24k) 10¯m/h 4.25
Outdoor
Compressor Mitsubishi
Net dimension W/D/H mm 920/385/762
Package dimension W/D/H mm 1085/487/843
Net/Shipping weight kg 55/61
Air flow(cooling/heating) Max. m³/h 2500
Sound power level Hi dB 69
Sound pressure level Hi dB(A) 56

Vertical Airflow
Running current Max. A 14.3
Refrigerant type R410A/R32 R410A
Refrigerant charge R410A/R32 g 1950
Liquid side diameter mm / inch 6.35
Super long vertical blowing cabinet design, supplying fast comfort Gas side diameter mm / inch 12.7

for big space. Refrigerant pipe Max. pipe length/height m 25/15


Max. pipe length without additional charge m 10
additional charge g/m 20

Rating Conditions: Cooling Indoor 27°C DB / 19°C WB. Cooling Outdoor 35°C DB / 24°C WB. Heating Indoor 20°C DB. Heating Outdoor 7°C DB / 6°C WB.(DB: Dry Bulb; WB: Wet Bulb)
For detailed information about ERP, please visit our page http://www.haier.com/ecodesign.

69 70
Portable Air Conditioning
Portable Air Conditioning
Key Features

Design

Portable Air Conditioning


Appearance
Innovative & Compact Design

Display
LED Display

Control
Ergonomic design of
control panel
Profile
Smart
(right hand operation habit)

Air Flow
Cool down the room quickly with
auto-swing function Ideal for home & office use as an air conditioner, fan cooler and dehumidifier.

Air Outlet
The air outlet can open and close
automatically when switch on/off 9K 12K
Self-Diagnosis
Show the error code when the unit
has a malfunction

24h Timer
Friendly
Switch on/off the unit whenever
you want Specifications
Draining Model Unit AM09AN1LAA AM09AN1HAA AM12AN1LAA AM12AN1HAA
Two drain ports, both auto-draing and manual draining Btu/h 9000 9000 12000 12000
is available Cooling capacity
W 2640 2640 3520 3520

Universal Wheels
Btu/h N/A 10000 N/A 13000
Heating capacity
W N/A 2930 N/A 3800
The unit can be moved wherever that you want easily
Power Supply V~Hz,Ph 220 ~ 240,50,1 220 ~ 240,50,1 220 ~ 240,50,1 220 ~ 240,50,1

Controller Bracket Rated Input Cooling W 1010 1010 1350 1350


Rated Current Cooling A 4.8 4.8 6.4 6.4
Special design to hold the remote controller,
avoid missing the controller Rated Input Heating W N/A 1060 N/A 1400
Rated Current Heating A N/A 5.0 N/A 6.6
Power Cable Holder Btu/W·h 8.91 8.91 8.90 8.90
EER for Cooling(R-410A)
Hold the power cable, avoid any accident W/W 2.61 2.61 2.61 2.61

Btu/W·h N/A 9.43 N/A 9.26


COP for Heating(R-410A)
W/W N/A 2.76 N/A 2.71
Energy Class (EER/COP) / A/- A/- A/- A/-
Moisture Removal L/h 1 1 1.4 1.4
Air Circulation m3/h 350 350 400 400

Performance Noise
High

Mid
dB(A)

dB(A)
53

51
53

51
54

52
54

52

Multi-Function Low dB(A) 48 48 49 49

Can be used as AC/Fan/Dehumidifier in you home or office Body Size W×H×D mm 428×742×383 428×742×383 428×742×383 428×742×383
Pachage Size W×H×D mm 488×876×420 488×876×420 488×876×420 488×876×420

Strong Performance Net Weight/Gross Weight kg 30.5/34.3 30.7/34.5 31.5/35.3 31.7/35.7


Strong cooling capacity Appliation Area m2 15 ~ 20 15 ~ 20 20 ~ 25 20 ~ 25
Strong airflow (350m3/hr, 9k model) Set/40"HQ 394 394 394 394
Loading Quantity Set/40"GQ 264 264 264 264
Low Noise Set/20" 132 132 132 132
48dB(A) at low fan speed
* Remarks:1 The above technical data are for reference only. Haier reserves the right to modify them without notice.

73 74
Key Features

Design

Portable Air Conditioning


Appearance
Innovative & Compact Design

Display
LED Display

Control
Ergonomic design of
control panel
Profile
Smart
(right hand operation habit)

Air Flow
Cool down the room quickly with
auto-swing function Ideal for home & office use as an air conditioner, fan cooler and dehumidifier.

Air Outlet
The air outlet can open and close
automatically when switch on/off 9K 12K
Self-Diagnosis
Show the error code when the unit
has a malfunction

24h Timer
Friendly
Switch on/off the unit whenever
you want Specifications
Draining Model Unit AM09AN1LAA AM09AN1HAA AM12AN1LAA AM12AN1HAA
Two drain ports, both auto-draing and manual draining Btu/h 9000 9000 12000 12000
is available Cooling capacity
W 2640 2640 3520 3520

Universal Wheels
Btu/h N/A 10000 N/A 13000
Heating capacity
W N/A 2930 N/A 3800
The unit can be moved wherever that you want easily
Power Supply V~Hz,Ph 220 ~ 240,50,1 220 ~ 240,50,1 220 ~ 240,50,1 220 ~ 240,50,1

Controller Bracket Rated Input Cooling W 1010 1010 1350 1350


Rated Current Cooling A 4.8 4.8 6.4 6.4
Special design to hold the remote controller,
avoid missing the controller Rated Input Heating W N/A 1060 N/A 1400
Rated Current Heating A N/A 5.0 N/A 6.6
Power Cable Holder Btu/W·h 8.91 8.91 8.90 8.90
EER for Cooling(R-410A)
Hold the power cable, avoid any accident W/W 2.61 2.61 2.61 2.61

Btu/W·h N/A 9.43 N/A 9.26


COP for Heating(R-410A)
W/W N/A 2.76 N/A 2.71
Energy Class (EER/COP) / A/- A/- A/- A/-
Moisture Removal L/h 1 1 1.4 1.4
Air Circulation m3/h 350 350 400 400

Performance Noise
High

Mid
dB(A)

dB(A)
53

51
53

51
54

52
54

52

Multi-Function Low dB(A) 48 48 49 49

Can be used as AC/Fan/Dehumidifier in you home or office Body Size W×H×D mm 428×742×383 428×742×383 428×742×383 428×742×383
Pachage Size W×H×D mm 488×876×420 488×876×420 488×876×420 488×876×420

Strong Performance Net Weight/Gross Weight kg 30.5/34.3 30.7/34.5 31.5/35.3 31.7/35.7


Strong cooling capacity Appliation Area m2 15 ~ 20 15 ~ 20 20 ~ 25 20 ~ 25
Strong airflow (350m3/hr, 9k model) Set/40"HQ 394 394 394 394
Loading Quantity Set/40"GQ 264 264 264 264
Low Noise Set/20" 132 132 132 132
48dB(A) at low fan speed
* Remarks:1 The above technical data are for reference only. Haier reserves the right to modify them without notice.

73 74
Dimensional Indoor Nebula
AS07NS1HRA - WU/GU - AS09NS1HRA -
WU/GU - AS12NS1HRA - WU/GU AS15NS1HRA - WU/GU
Dawn 855
55
5 200
900
00
0 210
10
0
AS20
AS 20S2
S2SD
SD
D1F
1FA
A - AS
AS25
25
5S2
S2SD
SD1
SD 1F
FA - AS
S35
5S2
S SD1F
1FAA - AS
AS442S2SD
SD1F
SD 1FA
1F A
980 212

3 0
310
31
80
280
318
AS18NS1HRA - WU/GU AS24NS1HRA - WU/GU
997
99 230 1115
111 5 243

Flexis

336
322
AS20S2SF1FA - AS25S2SF1FA - AS35S2SF1FA AS50S2SF1FA
1009 223
866 196

327
301

Brezza
AS71S2SF1FA AS07BS4HRA - AS09BS4HRA - AS12BS4HRA AS15NS3HRA
1126 230
900 210
855 200

310
337

280
AS18NS3HRA AS24NS3HRA
997 230 1115 243
Flare
AS20S2SF2FA - AS25S2SF2FA - AS35S2SF2FA AS50S2SF2FA
870 196 1009 223

336
322
301

327
AS71S2SF2FA
1126 230 Tundra
AS09TA2HRA - AS12TA2HRA AS18TD2HRA - AS24TD2HRA
1008
337

820 195 225

280

318
Tundra Green
AS25TABHRA - AS35TABHRA AS50TDBHRA
1008 225
820 195 354
Console Cabinet
AF09AS1ERA - AF12AS1ERA AP24DF1HRA
280

318

720 253

1810
1780
AS68TEBHRA 377
1125 240
640

407
335

377 407

75 76
Dimensional Indoor Nebula
AS07NS1HRA - WU/GU - AS09NS1HRA -
WU/GU - AS12NS1HRA - WU/GU AS15NS1HRA - WU/GU
Dawn 855
55
5 200
900
00
0 210
10
0
AS20
AS 20S2
S2SD
SD
D1F
1FA
A - AS
AS25
25
5S2
S2SD
SD1
SD 1F
FA - AS
S35
5S2
S SD1F
1FAA - AS
AS442S2SD
SD1F
SD 1FA
1F A
980 212

3 0
310
31
80
280
318
AS18NS1HRA - WU/GU AS24NS1HRA - WU/GU
997
99 230 1115
111 5 243

Flexis

336
322
AS20S2SF1FA - AS25S2SF1FA - AS35S2SF1FA AS50S2SF1FA
1009 223
866 196

327
301

Brezza
AS71S2SF1FA AS07BS4HRA - AS09BS4HRA - AS12BS4HRA AS15NS3HRA
1126 230
900 210
855 200

310
337

280
AS18NS3HRA AS24NS3HRA
997 230 1115 243
Flare
AS20S2SF2FA - AS25S2SF2FA - AS35S2SF2FA AS50S2SF2FA
870 196 1009 223

336
322
301

327
AS71S2SF2FA
1126 230 Tundra
AS09TA2HRA - AS12TA2HRA AS18TD2HRA - AS24TD2HRA
1008
337

820 195 225

280

318
Tundra Green
AS25TABHRA - AS35TABHRA AS50TDBHRA
1008 225
820 195 354
Console Cabinet
AF09AS1ERA - AF12AS1ERA AP24DF1HRA
280

318

720 253

1810
1780
AS68TEBHRA 377
1125 240
640

407
335

377 407

75 76
Dimensional Outdoor 1U68
1U68RE
68REFF
REFFRA
FFRA
98
987
890
890
9
353

Dawn

7
97
697
80
680
1U25S2PJ1FA - 1U35S2PJ1FA
893 338 364
820 405

Super Match Nebula/Brezza/Console


600.2
614

1U09BS3ERA - 1U12BS3ERA 1U15BS3ERA


864 290
780 245
780
324
590 365

597
576
540
Super Match II+ Flexis/Flare 317
347
500

1U25S2SM1FA - 1U35S2SM1FA 1U50S2SJ2FA 1U18FS2ERA(S) 1U24GS1ERA


858 893 338 810 288 860 308
280
800 820
600.2

688
614
550

730
324
510 313 590 365
347

1UH071N1ERG Tundra
860 308 1U09BE8ERA - 1U12BE8ERA 1U18EE8ERA
780 245 839 245
780
730

540

640
631
256
500 286

Cabinet
Tundra Green 1U24RE8ERA 1U24SE3ERA
987 353 920 385
1U25BEFFRA - 1U35BEFFRA 1U50JEFFRA 890
893 338
780 245 820
697
680

762
600.2
614
540

364
324 405
590 365 628

77 78
Dimensional Outdoor 1U68
1U68RE
68REFF
REFFRA
FFRA
98
987
890
890
9
353

Dawn

7
97
697
80
680
1U25S2PJ1FA - 1U35S2PJ1FA
893 338 364
820 405

Super Match Nebula/Brezza/Console


600.2
614

1U09BS3ERA - 1U12BS3ERA 1U15BS3ERA


864 290
780 245
780
324
590 365

597
576
540
Super Match II+ Flexis/Flare 317
347
500

1U25S2SM1FA - 1U35S2SM1FA 1U50S2SJ2FA 1U18FS2ERA(S) 1U24GS1ERA


858 893 338 810 288 860 308
280
800 820
600.2

688
614
550

730
324
510 313 590 365
347

1UH071N1ERG Tundra
860 308 1U09BE8ERA - 1U12BE8ERA 1U18EE8ERA
780 245 839 245
780
730

540

640
631
256
500 286

Cabinet
Tundra Green 1U24RE8ERA 1U24SE3ERA
987 353 920 385
1U25BEFFRA - 1U35BEFFRA 1U50JEFFRA 890
893 338
780 245 820
697
680

762
600.2
614
540

364
324 405
590 365 628

77 78
Air Conditioning

Easy
Installation

Whispering Smart
Air Control

Health Energy
Care Saving

For More Information, Please Visit


http://www.haierac.com
Air Conditioning

Easy
Installation

Whispering Smart
Air Control

Health Energy
Care Saving

For More Information, Please Visit


http://www.haierac.com
DC
Motor
Increase 7%
Length

Cross Flow Fan

2018 Residential General Catalogue


EU Sep. 2018

27°
Version 1.0

Detachable Bottom Cover 175mm

EU
ADDRESS
No.1 Haier Road, Hi-tech Zone, Qingdao 266101 P.R.China
CONTACTS
Tel: +86-532-8893-7937
Website: www.haierac.com
2018 RESIDENTIAL
AIR CONDITIONING

You might also like