KHARISMA SAMUDRA
INSPECTION,CONSULTAN,SHIP ENGINEERING & GENERAL SUPPLIER
FLF HANA
WALL THICNESS MEASURMENT TEST REPORT
" Terima Kasih Atas Kepercayaan Yang Telah Anda Berikan Kepada Kami "
PT. KHARISMA SAMUDRA
LIST OF CONTENT
ATTACHMENT
ATTACHMENT
PT. KHARISMA SAMUDRA
CLIENT NAME PT. Sejahtera Karunia Lines REPORT NO 13 / KS-BPN / TEK / UTG / X / 2017 PAGE NO 1
NAME OF ITEM Air Tube ( ME I & ME II ) LOCATION Dock PT. GBU ,Balikpapan TESTING DATE October 20 , 2017
D B D B
C C
240
240
1 1
2 2
1770
1770
Tube I Tube I
3 3
230
230
Note :
Inspection Area
1, 2, 3 (A - B - C - D)
Tested by : PT. Kharisma Samudra Reviewed by : PT. Sejahtera Karunia Lines Surveyor : Biro Klasifikasi Indonesia