1.-CHARACTERISTICS
Epoxyacrilate resin
3 EPOXY MORTAR
Sizes: 300 and 410 ml cartridges
8 CLEANING BRUSHES MORCEPKIT: Kit of 3 cleaning brushes. ø14, ø20 and ø29 mm.
9 CLEANING PUMP MOBOMBA: Air pump for expelling powder and leftovers
THREADED METALLIC
13 MOTRO: Threaded metallic sleeve M8, M10, M12, zinc plated.
SLEEVE
14 METALLIC SLEEVE MOTM: Metallic sleeve ø8, ø10, ø12 x 1000 mm.
EQAC10130
EQAC12160
EQAC16190
EQAC20260
EQAC24300
EQAC30330
Zinc platted yellow pasivated stud code
EQA208110
EQA408110
EQA210130
EQA410130
EQA212160
EQA412160
EQA216190
EQA416190
EQA220260
EQA420260
EQA230330
EQA430330
Stainless steel stud code A2 / A4
EQA24300
EQA44300
Use a plastic or a metalic sleeve for applications in hollow bricks, in order to stop the mortar from running
out through the bricks’ holes, thus obtaining a perfect fit.
STYRENE With styrene With styrene With styrene Styrene-free Styrene-free ------
MOEPSEW300
MOEPSEW410
MOPOSEP300
MOPOSEP410
MOPOSE300
MOPOSE410
MOEPOX300
MOPOEX410
MOPURE600
MOPOLY170
MOPOLY300
MOPOLY410
MOEPSE300
MOEPSE410
MOVISE300
MOVISE410
CODE
CARTRIDGE
MIXER
MORCAPU
MORCANU
GUN
• The recommended resins for this application are Polyester, Epoxy, Vinylester or Pure epoxy.
• The concrete base must be compact and porosity insignificant.
• Installation temperature range for base material: +5 / + 40 ºC
• Installation temperature for mortar: > 5 ºC
• Istallation may be performed into wet holes as long as they are not flooded, as mortar injection into the
hole does not expel water out correctly. Only MOEPSE offers the possibility of installation into flooded
holes.
• Minimum installation depth values must always be respected: for anchors’ depth, for anchor-to-anchor
distances and for anchor-to-edge distances.
• Drilling must be performed by respecting the specified minimum depth and diameter, perpendicular to the
base material’s surface. The holes on the material to be fixed may be used as templates. Diamond drill
bits are not to be used.
• When drilling near any reinforcement areas, special care must be taken to avoid damaging them. If
drilling is aborted because a reinforcement area has been encountered, it is advisable to drill a new hole
at a minimum distance of at least twice the aborted drill hole. This advisable distance may be reduced,
as long as the aborted hole is previously filled up with high-resistance mortar. In any case, if the aborted
hole is not filled up with mortar, no shear or oblique tension load in the direction of load application will be
tolerated at a shorter distance than the installation depth value hef.
• It is necessary to clean the holes free of dust and debris by following this or a similar procedure:
Step 1: Blow the holes twice by using a hand air-pump.
Step 2: Brush into the holes twice (check table for appropriate brush size).
Repeat these two steps for three more times.
Extreme caution at this point when dealing with these types of anchors
• Remove the cartridge cap, screw the nozzle onto the cartridge and then place the set into the gun. Pull
the trigger repeatedly until a homogeneous gray mixture of mortar comes out through the nozzle. Any
iridescent colors mean the mixture is not appropriate yet. Always discard the first two doses of mortar
from every cartridge, which are never to be used for any fixings.
Special indication for 170 ml and 300 ml cartridges: cut off the bag immediatedly after the seal
clip.
Special indication for 600 ml cartridges: these cartridges take special nozzles under code
MORCAPU. Standard nozzles valid for the rest of cartridges under code MORCANU are not valid
for these cartridges.
• Fill up the hole with the minimum quantity of mortar indicated on the table. Introduce the nozzle down to
the end of the hole when doing so, in order to avoid air bubbles. Our Mortar Calculation Software may be
used for estimating the number of cartridges necessary for each application and which is available on our
website www.indexfix.com.
• Introduce the stud or rod by screwing it slightly down to the installation depth value, in order to make sure
any remaining debris fuses with the mortar and within the handling time. The mortar must overflow the
hole to ensure that the gap between the stud and the hole is completely full.
• Wait for the specified curing time. Do not apply any loads onto the anchoring during curing time. Further
adjustments of the stud are likely to be necessary during curing time, as the hole diameter is always
bigger than the bolt/rod diameter. Be aware the mortar does not overflow the hole on walls or ceilings.
• If the cartridge is not used up, keep it with the nozzle on. Change the nozzle in the case the handling
time has expired, and always discard the first two doses of mortar.
Base material
Type Handling time Curing time
temperature
MOPOLY +5 a +10 ºC 18 min 120 min
Polyester
MOEPSE
styrene
0 a +5 ºC 10 min 75 min
+5 a +20 ºC 5 min 50 min
+20 ºC 100 seg 20 min
Mínimo +5 ºC 12 min 180 min
styrene free
MOVISE
MOPURE
• After curing time, apply torque. Do not exceed the torque shown on this table.
• In case the holes on the material to be fixed are bigger than they should, a bigger and thicker washer
may be inserted. However, this will not ensure a perfect shear load balance from anchor to anchor in a
group. Thus, the shear load will only apply to the anchors with a correct diameter on the material to be
fixed.
Extreme caution at this point when dealing with these types of anchors
• Insert the plastic sleeve into the hole so it does not stand out of the base material’s surface. Remove any
plaster leftovers so the sleeve equals the surface of the wall.
• Remove the cartridge cap, screw the nozzle onto the cartridge and then place the set into the gun. Pull
the trigger repeatedly until a homogeneous gray mixture of mortar comes out through the nozzle. Any
iridescent colours mean the mixture is not appropriate yet. Always discard the first two doses of mortar
from every cartridge, which are never to be used for any fixings.
Special indication for 170 ml and 300 ml cartridges: cut off the bag immediately after the seal clip.
• Fill up the sleeve with the minimum quantity of mortar indicated on the table. Introduce the nozzle down
to the end of the hole when doing so, in order to avoid air bubbles. Our Mortar Calculation Software may
be used for estimating the number of cartridges necessary for each application and which is available on
our website www.indexfix.com.
• Introduce the stud or rod by screwing it slightly down to the installation depth value, in order to make sure
any remaining debris fuses with the mortar and within the handling time.
• Wait for the specified curing time. Do not apply any loads onto the anchoring during curing time. Further
adjustments of the stud are likely to be necessary during curing time, as the hole diameter is always
bigger than the bolt/rod diameter. Be aware the mortar does not overflow the hole on walls or ceilings.
• If the cartridge is not used up, keep it with the nozzle on. Change the nozzle in the case the handling
time has expired, and always discard the first two doses of mortar.
Base material
Type Handling time Curing time
temperature
+5 a +10ºC 18 min 120 min
MOPOLY
Polyester
MOPOSEP
styrene-
MOPOSE
Store the product in a dry, cool place, away from sunlight and any heat sources, at a temperature of +5
ºC to +25 ºC.
The shelf-life of the unopened product: approximately 18 months from manufacturing date. The expiry
date is indicated on the side of the cartridge.
7. RECOMMENDED RESISTANCES
Recommended resistances(*) for C20/25(**) concrete for an isolated anchor (without anchor-to-anchor or
anchor-to-edge distance effects considered) are shown on the table:
Shear VRk [KN] 9.5 15.1 21.9 40.8 63.7 91.8 ---
Tension NRk [KN] 18.6 23.1 27.4 36.9 53.5 65.9 ---
Stain.
steel
Shear VRk [KN] 12.8 20.3 29.5 55.0 85.8 123.6 ---
Tension NRk [KN] 14.9 20.8 31.5 36.1 52.9 106.8 ---
Galv.
Polyester
MOPOSEP
MOPOSE
styrene
without
Shear VRk [KN] 9.5 15.1 21.9 40.8 63.7 91.8 ---
Tension NRk [KN] 14.9 20.8 31.5 36.1 52.9 106.8 ---
Stain.
steel
Shear VRk [KN] 12.8 20.3 29.5 55.0 85.8 123.6 ---
Tension NRk [KN] 20.4 25.4 29.3 51.9 70.9 101.5 ---
Galv.
with styrene
Epoxyacril.
MOEPOX
Shear VRk [KN] 9.5 15.1 21.9 40.8 63.7 91.8 ---
Tension NRk [KN] 20.4 25.4 29.3 51.9 70.9 101.5 ---
Stain.
steel
Shear VRk [KN] 12.8 20.3 29.5 55.0 85.8 123.6 ---
Tension NRk [KN] 20.1 26.8 39.4 56.5 90.7 126.6 135.0
Galv.
Epoxyacril.
MOEPSEW
MOEPSE
styrene
without
Shear VRk [KN] 9.5 15.1 21.9 40.8 63.7 91.8 145.9
Tension NRk [KN] 20.1 26.8 39.4 56.5 90.7 126.6 135.0
Stain.
steel
Shear VRk [KN] 12.8 20.3 29.5 55.0 85.8 123.6 196.4
Tension NRk [KN] 20.8 30.0 45.8 61.9 81.4 124.0 135.0
Galv.
styrene free
Vinylester
MOVISE
Shear VRk [KN] 9.5 15.1 21.9 40.8 63.7 91.8 145.9
Tension NRk [KN] 20.8 30.0 45.8 61.9 81.4 124.0 135.0
Stain.
steel
Shear VRk [KN] 12.8 20.3 29.5 55.0 85.8 123.6 196.4
Tension NRk [KN] 29.1 40.3 59.6 90.9 94.8 --- ---
Galv.
styrene free
Pure epoxy
MOPURE
Shear VRk [KN] 9.5 15.1 21.9 40.8 63.7 --- ---
Tension NRk [KN] 29.1 40.3 59.6 90.9 94.8 --- ---
Stain.
steel
Shear VRk [KN] 12.8 20.3 29.5 55.0 85.8 --- ---
1 KN ≈ 100 kg
Underlined cursive values stand for steel failure. The rest of the values stand for extraction failure.
Safety factor values for high-resistance types of concrete:
Shear -- 1.25
Tension 2.10 --
Stain
steel
Shear -- 1.56
1.4
Tension 1.80 --
Galv.
MOEPOX
MOPURE
MOEPSE
MOVISE
Shear -- 1.25
Tension 1.80 --
Stain
steel
Shear -- 1.56
(*) The recommended resistance stands for values with a 95% probability to be reached at a test. It depends on
the number of tests performed, average value and value alterations. It includes a safety coefficient of 3.
(**) Concrete C20/25 as per ENV206: characteristic resistance for an age ≥ 28 days:
•
2
Cylindrical simple test ø 150 mm. x 300 height ≥ 200 N/mm
•
2
Cubic sample test 150 mm. side ≥ 250 N/mm
The recommended resistance values for traction (N) and shear (V) are indicated on the table below:
METAL SLEEVE
THREADED ROD
WITH INNER THREAD
BASE MATERIAL
NRK = VRK (KN) NRK = VRK (KN)
M8 M10 M12 M8 M10 M12
Brick type 1 2.50 2.00 2.00 1.50 2.50 2.50
Brick type 2 (a+b) 0.75 1.20 0.50 - 0.75 0.40
Brick type 3 2.00 2.00 4.00 3.00 4.00 5.00
Brick type 4 0.75 0.90 1.50 2.00 1.50 0.90
M8 M10 M12
BASE MATERIAL Smin / Cmin Scr Smin / Cmin Scr Smin / Cmin Scr
[mm] [mm] [mm] [mm] [mm] [mm]
Brick type 1 100 235 100 235 120 235
Brick type 2 (a+b) 100 250 100 250 120 250
Brick type 3 50 160 50 200 60 240
M8 M10 M12
BASE MATERIAL Smin / Cmin Scr Smin / Cmin Scr Smin / Cmin Scr
[mm] [mm] [mm] [mm] [mm] [mm]
Brick type 1 100 235 100 235 120 235
Brick type 2 (a+b) --- --- 100 250 120 250
Hollow clay brick HLz 12-1,0-2DF (EN771-1) Hollow sand lime brick KSL 12-1,4-3DF (EN771-2)
Lenght/width/height: 235mm/112mm/115mm Lenght/width/height: 240mm/175mm/113mm
2 3 2 3
fb≥12 N/mm / ρ ≥1,0 kg/dm fb≥12 N/mm / ρ ≥1,4 kg/dm
Hollow sand lime brick KSL 12-1,4-83DF (EN771-2) Solid clay brick KSL 12-2, 0-DF (EN771-1)
Lenght/width/height: 250mm/240mm/237mm Lenght/width/height: 240mm/116mm/71mm
2 3 2 3
fb≥12 N/mm / ρ ≥1,4 kg/dm fb≥12 N/mm / ρ ≥2,0 kg/dm
Solid sand lime brick KSL 12-1, 4-3DF (EN771-2) Hollow clay brick HLzW 6-0,7-8DF (EN771-1)
Lenght/width/height: 240mm/115mm/70mm Lenght/width/height: 250mm/240mm/240mm
2 3 2 3
fb≥12 N/mm / ρ ≥2,0 kg/dm fb≥6 N/mm / ρ ≥0,8 kg/dm
Lightweight concrete hollow block Hbl 2-0,45-10DF Lightweight concrete hollow block Hbl 4-0,7-8DFF
(EN771-3) (EN771-3)
Lenght/width/height: 250mm/300mm/248mm Lenght/width/height: 250mm/240mm/248mm
2 3 2 3
fb≥2 N/mm / ρ ≥0,45 kg/dm fb≥4 N/mm / ρ ≥0,7 kg/dm
Brick type 8
Check: the increased load must be lower than the reduced resistance
20 KN x 1.4 ≤ 2 x 30.0 KN / 1.8
The anchors’ studs must be at a minimum distance of 180 mm, and must also keep a minimum distance
of 90mm to any edges.