Type YXQ-280 MD
Stainless Steel Gas/Electric Powered
Handheld Compressed Steam Sterilizer
User’s InstructionWarning
‘Water supply must not be halted.
Special purposed equipment for sterilization and disinfections
The lid of the devi
270,
must not be opened unless the pointer of the pressures gauge returns to
To avoid the occurrence of accidents, the pressure gauge, safety valve, release valve must be
cleaned before they are used. At least one check shall be done every month.
Divided as per the anti-electrie-shock category, this equipment falls into:
‘Class | equipments
Divided as per the level of anti-clectric-shock, this equipment falls into:
‘Type B equipments
Divided as per
he protective level harmful intruding liquids, this equipment falls into:
Ordinary equipment (sealed equipment that js not intruding liquids proof)
Divided as per the sai
ely level when the device is used in applications with existence of
flammable anesthesia gases or with existence of the mixture of faramable anesthesia gases
and aie or
the oxygen and nitrous oxide, this equipment is
[Equipment that cannot be used in the above-mentioned circumstance.
Divided as per the working mode, :his equipment falls into:
Continuously operating equipments.Application scope:
This device is used for sterilization of surgical insuments, top dressings, glasswares and
medicines in medical institutions and hospitals.
B. Application environment: (including transportation and storage conditions):
This equipment shall be used at environmental temperature +10°C-40°C, relative humidity shall
bbe 30%-70% and atrospheric pressure shall be 700~1080hPa,
C. Working principle
The compressed stream is a colorless, tasteless, odorless and non-toxic gas. As water is heated in a
sealed container, it will be converted into stream that has pressure. The temperature of the steam
rises with the inorease of pressure. The steam has excellent permeating ability, which is able to
isture and heat” can quickly kill the
quickly humidify and heat the objects in the container. “Mi
microorganism, reaching perfect sterilizing effects, There’s no contamination left on the sterilized
or irritation to human texture, This device is suitable for
objects and it causes no allerg)
sterilization for large objects and objects in large quantities, featuring in the advantages of reliable
effects, simple operation and low casts
Structural features:
The main body, lid and sterilizing bucket of the Stevilizer are made of 1Cr Ni Ti high
quality stainless steel boards, which is shaped by punching and cutting-edge weldi
approaches, being both durable and sturdy.
rged electric heating tubes mounted at the bottom of the main body of
the sterilizer. The sterilizer is featured in prompt heating, simple operation, and compact
2. There are subm:
structure.
‘The sterilizer can also be heated with other heating sources such as electric stove,
kerosene stove, gas stove, charcoal stove and wood buming stove, ete. Therefore, the
sterilizer is suitable to be used by small clinics and testing lab as well as ambulant
‘medical groups.
4, There is 2 safety valve, release valve and pressure gauge mounted on the lid of the
sterilizer. When the pressure is excessively high, it can be released, which makes the
sterilizer safe and reliable, Metal soft pipe is attached at the til of the release valve,
making the cold sir discharging easy and convenient.
E. Technical datum
Max. sterilizing temperature: 126°C
1
2. Volume of the sterilizing bucket: I8L (dia280X 260m/m)
3. Power consumed: 2K W/AC220V SH.F. How to use:
Fill clean water to desired height in the sterilizer.
Place the objecis to be sterilized into the sterilizing bucket,
Secure the Tid of the sterilizer until itis properly sealed.
Connect the electricity and start the heating procedure. Open the air releasing valve and
shut it when the cold air is completely discharged. At this time, the sterilizer is in standby
mode and ready to work.
G. Maintenance:
1, The main body and bucket of the sterilizer shall be from time to time kept clean.
2. If the sterilizer is to be kept
dustproof plastic films.
3. The sterilizer shall be used in a well-ventilsted environment with no corrosive gases,
4. The pressure gauge, sa‘ety valve, release valve mi
one check shall be done every month,
for a long time, It is necessary to cover it up with
1 be checked periodically. At least
H. Noteworthy matters:
L. Before filling any water in, it is strongly prohibited to connect the power to avoid
‘damages to the heating tubes.
2. The lid of the device must not be opened unless the pointer of the pressures gauge returns
to zero.
This sterilizer is specfal purposed equipment for sterilization and it must not be used for
other purposes.
1. Time, temperature and pressure required by various objects to be sterilized
Objects ] Desized teraperature | Stream pressure | Relative temperature
keeping time for the (shown on the gauge) | of the saturated steam
| sterilization (Mpa) «cy
(Min)
Rubbers 1S ou 2b
“Top dressines 30-4 0.105-0.14 126
[Containers 15 o10s-0.14 | 26° |
Instruments | 126 |
Bottled solutions (21-126 |
J. Troubleshooting:
L,I one or more of the electric heating tubes is damaged, they shall be replaced with new
tubes that satisfy the Industrial Code
2. Ifair leakage is spotted on the lid, the bolt shall be fastened or the sealing ring shall be
changed. -3. [fthere is no pressure, it is necessary to check whether the electric tubes or the pressure
gauge is damaged, Ifo, they shall be replaced.
‘Attachment I: Packing list
SN Category Name Unit [Quantity | Remarks
L Main unit__| Sterilizer se [ot
2 | Document _| User's Instruction Copy 1 I J
3 Document | Packing list Copy |
4 | Document [Certificate of Compliance | Copy |
‘The items listed in the above packing list ere compliant with the plysical objects contained in the
carton, Packaging clerk: 3
ar warranty and repairing service is available throughout the
‘This product is covered by a one-y
service period of it, subject to the user's presentation of a copy of the invoice and the warranty
card, Should you have any questions, please don’t hesitate to contact our serviee department!
Note: The electric heating tubes are not covered by the warranty!
Attachment II: Quality Compliance Certificate
Product Quality Compliance Certificate
Product name: Stainless Steel Gas/Electrie Powered
Handheld Compressed Stesm Sterilizer Type and specifications: YXQ-280MD
Ex-work Code:_/o/o/28
Inspection Date: 1.0 = 20 1G Inspector:
3 __Ex-work Date: <0!
03