FIRE FIGHTING

INSTALLATION

DR. SARAJUL FIKRI MOHAMED


DEPARTMENT OF QUANTITY SURVEYING
FACULTY OF BUILT ENVIRONMENT
UNIVERSITI TEKNOLOGI MALAYSIA

SBQ 3314 BUILDING MEASUREMENT III


Fire Fighting Installation
System
Measurement Rules

SECTION Q
PLUMBING AND MECHANICAL
ENGINEERING INSTALLATIONS
Measurement Rules
Section Q

Q.1 Information Equipment and Ancillaries


Q.2 Clasification Of Work Q.19 Generally
Q.3 Location of works Q.20 Antivibration and sound insulation
Q.21. Equipment support
Pipeworks Q.22. Jointing
Q.7 Generally Q.24. Identification plates
Q.8 Pipe and Fittings
Q.9 Special Connection, etc Builder’s Work
Q.10 Labour Q.31 Generally
Q.11 Sundries Q.32. Particularly
Q.12 Pipework Support
Q.13 Connection
FIRE FIGHTING SYSTEM
COMPONENTS
1. Builder’s Work
2. Hose Reel System
 Swing hose- reel, Water storage tank, Electrical duty pump, Diesel
duty pump, Piping: incoming pipe -rising pipe, distribution pipe
3. Fire Alarm panel
 Manual Break Glass, Fire Alarm Bell, Batteries, Batery Charger

4. Brasswork
 Air release valve, Gate valve, Check valve, Strainer valve, Flexible
joint
5. Portable Fire Extinguisher
6. Equipment and Ancillaries
 Concrete plinth
7. Pipe Support
 Pipe hanger
8. Sundries
 Testing
Fire Fighting Installation
MEASUREMENT RULES

R.2 Clasification of Work

D.Fire Fighting Installation


FIRE FIGHTING INSTALLATION

Standpipe Sprinkler Portable

Wet Dry Wet Pipe Dry Pipe Pre-action Deluge


Standpipe Standpipe System System System System

Hose Reel - Water tank - Water tank


- Pump - Pump
- Pipes - Pipes
- Sprinkler - Sprinkler
- Alarm - Fire Detector
- Alarm
MEASUREMENT RULES
GENERALLY
Q.1 INFORMATION

FIRE FIGHTING INSTALLATION

Generally
Q.1. Information
1 Particulars of the following shall be given :
a) Regulation, etc.
b) Kind and quality of material.
c) Gauge, thickness or substance of material.
d) Any tests, etc.
THE FIRE PROTECTION SYSTEM INSTALLED ARE IN
FULL COMPLIANCE AND REGULATIONS

1. The British Standards Institution 750 For Fire Hydrant


2. The British Standards Institution 5839 Part 1, 1980
For Fire Alarm System
3. The Requirements Of The Chief Inspectorate Of The
Fire Services Malaysia.
MEASUREMENT RULES

Q.1.2 Assembling and jointing together the component


parts of composite units and providing any
necessary connecting flanges and jointing
materials shall be deemed to be included with
the items concerned. Where composite units are
supplied by the Employer, particulars shall be
given of the assembly work involved.

Q.1.3 Patterns, moulds, templets and the like shall be


deemed to be included with the items.
MEASUREMENT RULES
Q.1.4 Priming and painting off-site and proprietary
finishes or surface treatment applied as part of
the production process shall be described
stating whether applied before or after
fabrication or assembly.

Q.1.5 Except where otherwise stated the method of


fixing and the provision of nails, bolts, nuts,
holes, screws, plugs, shot-fired pins and the like
shall be given in the description of the work.
FIRE FIGHTING INSTALLATIONS
MEASUREMENT RULES
Q.1.6 The nature of the background to which work is to
be fixed shall be given in the description. Any
necessary drilling of the backgrounds shall be
deemed to be included. Backgrounds shall be
classified as follows :
a) Building-board which shall be deemed to
include hardboard, compressed cement sheet,
plasterboard, fibreboard and similar materials
which do not grip woodscrews.
MEASUREMENT RULES
Q.1.6 The nature of the background ….
b) Timber which shall be deemed to include
softwood, hardwood, blockboard, plywood and
similar materials which will grip wood-screws when
a lead-hole has been drilled.
c) brickwork, concrete or stone work
d) plain metal
e) glass
MEASUREMENT RULES

Q.1.7. Temporary work shall be so described.


Removing temporary work and making good
after shall be deemed to be included with the
item.
1.8. Connecting to existing services – shall be
described
MEASUREMENT RULES

GENERALLY

Q.2. CLASSIFICATION OF WORK


Q.2.1 Work together with its metalwork, supports and
the like (unless associated with more than one
installation) shall be classified as follows and
given under an appropriate heading :

d) Fire Fighting Installation


MEASUREMENT RULES

Q.3. LOCATION OF WORK


Location of works :
a. Internally
b. Externally
c. In plant rooms
MEASUREMENT RULES

PIPE WORKS
Q.7 GENERALLY
1. Purpose-made pipes and purpose-made pipe
fittings shall be described.
2. Pipes and pipe fittings which are wrapped, coated
or lined by the manufacturer shall be so described
stating the type of treatment.
3. Pipework required to be temporarily fixed in
position, dismantled for chromium-plating or other
special finishing and subsequently refixed shall be
so described.
MEASUREMENT RULES
Q.8 PIPE AND FITTING
1. Pipes (measured over all pipe fittings, short
running lengths and branches) shall be given in
metres stating the type and the normal size.

Purpose-made pipe shall be so described and


given separately. Curved pipes shall be so
described stating the mean radius.

Joints in the running length shall be given in the


description stating the method of jointing.
SETS OF FIRE FIGHTING EQUIPMENT

Portable FE
Hose Reel
MEASUREMENT RULES
Q.8 PIPE AND FITTING
3. Flexible pipes and extensible pipes (measured as
fully extended) shall each be so described.

4. Pipes laid or fixed in ducts, trenches and chases or


embedded in in-situ concrete or screeds shall each
be so described.
PIPE FITTINGS
Pipe fittings
Piping inside
switch room

Conduit

Heat detector

Hose reel pipe


MEASUREMENT RULES
Q.9. SPECIAL CONNECTIONS, ETC.
1. Special connections and special joints in pipes shall
each be enumerated separately (except where
given in the description of another enumerated item)
stating the nominal size and kind of pipe concerned
and the method of jointing. Classification shall be as
follows :

a) Connections between pipes of differing materials


and differing grades of the same material.
b) Connections between pipes and appliances or
equipment.
c) Connections to existing pipes.
MEASUREMENT RULES
Q.10.LABOURS
Labours on pipes (e.g. made bends, made springs,
made offsets, beaded ends, ornamental ends, etc.)
shall be deemed to be included with the pipes on which
they occur.
MEASUREMENT RULES
Q.11 SUNDRIES
6. Pipe-sleeves through walls, floors ceilings shall be
enumerated stating the type, lengths, the nominal
size and kind of pipe passing through and the type
of packing required, and if to be supplied for fixing
by other trades, this shall be so described.
7. Wall, floor or ceiling plates shall be grouped
together as plates and enumerated stating the
type and size.
PIPE-SLEEVES
MEASUREMENT RULES
Q.12 PIPEWORK SUPPORTS

12.1 Standard pipe supports shall be given in the


description of the pipes stating the type and
spacing of the supports.

12.2. Non-standard pipe supports shall be described


and enumerated (no).
MEASUREMENT RULES
Q.12 PIPEWORK SUPPORTS
4. Components or assemblies of components (e.g.
clips, saddles, pipe-hooks, holderbats, brackets,
rollers, chairs and hangers or black-plates and
girder-lugs) used to fix supports for more than
one pipe shall be enumerated separately stating
the type and size of components. Spring
compensated components shall be so described
stating the loading and movement to be
accommodated.
PIPEWORK SUPPORTS
PIPE SUPPORT
MEASUREMENT RULES

Q.13 CONNECTIONS
Connections to public mains, making good public
highway and any other work which may only be
carried out by a Public Undertaking or Local
Authority shall be given as a provisional sum.
MEASUREMENT RULES
EQUIPMENT AND ANCILLARIES
Q.19 Generally
1. Unless otherwise stated, equipment such as boilers,
generators, heaters, water treatment plant, tanks
cylinders, calorifiers, pumps, coolers, air-handling
unit, fans, refrigerator equipment, meters, sanitary
fittings, etc. and ancillaries such as soot doors to
boilers, valves and cocks, gauges, automatic
controls etc. shall be enumerated and related to the
specification referred to in clause Q.1.1.
MEASUREMENT RULES
EQUIPMENT AND ANCILLLARIES
Q.19 Generally

2. Shall be described in conjunction with a


manufacturer’s detailed specification (Q.19.2)

3. Any limiting dimensions on the size shall be


given. (Q.19.3)

4. Electrical connection shall be given in


accordance with section R . (Q.19.4)
DIESEL PUMP

 Pengganti apabila pam operasi elektrik tidak dapat berfungsi.


 Stanby pump.
 135 main flow, 40 m tekanan dan 2900 rpm
 Equipments and ancillaries, Q.19.kecuali dinyatakan peralatan
seperti tangki, silinder pam serta injap dan pili perlu di nyatakan.
Unit NO
CO2 Fire Extinguishing Systems

 Carbon dioxide fire extinguishing systems are used


because of the most efficient extinguishing agents
 It is situated at the switch room
 It removes the oxygen and covers the surrounding
atmosphere and literally strangles the fires to death.
 Advantages:
a) odorless and non-toxic
b) dry, inert gas, it will not conduct electricity
c) cannot damage clothes or equipment nor
contaminate liquids or food
HOSE REEL SYSTEM:
WET PIPE
HOSE REEL SYSTEM
 Pressurised using 1 unit of electrical pumpset as duty pump
& 1 unit diesel engine pumpset as standby
 Designed to operate an automatic mode (Pressure switch)
& manual mode (manual starting from the pumpsets control
panel)
 Standard coil length 30m, 36m or 100m.
 Specification :-
Working Pressure : 220Psi (15 Bar)
Minimum Burst Pressure : 696Psi (48 Bar)
Test Pressure : 250Psi
Nozzles Hose reel Fire Hose
Reel

Fire Hose
Reel
Pressure
Hose Guides
Reducing Valve
TYPICAL HOSE REEL
WET RISER
Is constantly filled with water and the
supply should be capable of
maintaining a running pressure of
410kPa at the highest landing valve
and give a flow rate of 23litres per
second. The maximum running
pressure permitted with one outlet
open should be 510kPa.

To maintain the required water


pressure it is usually necessary to
install pumping equipment. Direct
pumping from the main is not
permitted and a suction tank with a
minimum actual volume of water of
45.5 m2 must be installed.
Hose reel Piping

COMPONENTS

Brasswork Water Tank

Pump:
•Duty pump
•Standby pump
WATER STORAGE TANK

 Equipments and ancillaries


– Clause Q.19.
– Unless otherwise stated, equipment such as tank
shall be enumerated (no).
HOSE REEL
 Hose reel wall
mounted
VALVE

BIB Horizontal
HOSE

 General purpose synthetic


delivery hose. Suitable for
industrial and rural fire
brigades as well as static
building protection.

 General industrial, commercial


and civil engineering
applications including water
authorities where a high burst
performance hose is not
necessary

 Lightweight and flexible


Heat and cold resistant
Anti rot and anti-twist
BRANCH PIPE AND NOZZLE
 Branch pipes provide an adjustable
nozzle to allow the curtain of water to
be altered from a narrow spray to a
wide spray.

 Nozzles provide a fixed jet of water.


The basic branch pipe according to
BS336 has an 21/2" inlet male
instantaneous and outlet threaded
11/3" BSP male for either a plain jet
or a branchpipe adjustable nozzle.

 The branch pipe is controlled from


SHUT-OFF through JET and SPRAY
to wide angle CURTAIN by rotating
the annular sleeve.
HOSE REEL SYSTEM:
DRY PIPE
System for dry riser

This range includes:

 inlet breechings
 inlet and outlet
cabinets
 outlet valves
 standpipes, bars and
keys.
DRY RISER COMPONENT
DRY RISER

 Designed to house inlet


breechings and landing
valves
 Georgian wired glass panel
and spring cylinder lock with
key
 Manufactured from zintec,
epoxy polyester powder
coated - Red
FIRE EXTINGUSHER
FIRE EXTINGUSHER
Dry powder Water

Type of Fire
Extinguisher

Gas

Foam
Carbon
dioxide
(CO2)
Portable Fire Extinguisher

PORTABLE FIRE EXTINGUISHER

1. Dry powder-No
2. Testing-item.

CARBON DIOXIDE SYSTEM

1. CO2 cylinder-No
2. Testing-item.
POWDER EXTINGUISHERS
WATER EXTINGUISHERS
Foam extinguishers
Portable Fire Extinguisher.

 Alat pemadam
mudahalih (Portable Fire
Extinguisher) digunakan
melindungi bangunan
dari bahaya kebakaran
kecil.
Carbon Portable Dry
Dioxide fire Chemical Powder
extinguisher Fire Extinguisher

Portable foam &


water Extinguisher
ALARM SYSTEM
MANUAL ALARM

COMPONENTS
 Fire alarm panel
 Manual break glass
 Alarm bell
MANUAL BREAK GLASS
SMOKE DETECTOR
SMOKE DETECTOR
SMOKE DETECTOR
 Fire alarm system is
functioning as a
components which give
warning sign to occupants in
a building if it is burning.
 It normally, installed with
detector.
 There is 2 type of detector,
passive (Manual break
glass) and active (Smoke
detector, heat detector, light
detector).
LIGHT
LIGHT FITINGS
FITTINGS
Emergency light

‘Keluar’ Sign

Flashing lights
SPRINKLER SYSTEM

Sprinkler system adalah sebuah sistem gabungan antara paip-paip


yang dipasang di dalam bangunan dan sprinkler (overhead piping) bagi
membolehkan ianya digunakan sebagai alat pemadam api.

Alat-alat di dalam sistem :


Tangki Air (gravity Tank).
Fire Pump.
Tangki Simpanan (Reservoir/Pressure Tank).
 Penyambungan kepada Bekalan Utama (Connection to Main/City
Service).
MEASUREMENT RULES
EQUIPMENT AND ANCILLLARIES

Q.20 Anti-vibration and sound insulation

Anti-vibration mountings for plant shall be enumerated


stating the type and the size. Anti-vibration material
and sound-insulating material in plant bases shall be
given in square metres stating the nature of the
material and the thickness.
ANTI VIBRATION
MEASUREMENT RULES
EQUIPMENT AND ANCILLLARIES

Q.21 Equipment supports


1. Equipment supports shall be enumerated and
described.
2. Particulars of the method of fixing shall be given in
the description in accordance with clauses Q.1.5-
6.
FIRE HYDRANT
& HOSE REEL

PORTABLE FIRE
EXTINGUISHER
(DRY POWDER)
MEASUREMENT RULES

EQUIPMENT AND ANCILLLARIES


Q.22 Jointing

Particulars of the method of jointing shall be given in


the description of the equipment.
MEASUREMENT RULES

EQUIPMENT AND ANCILLLARIES


Q.24 Identification Plates

Identification plates shall be deemed to be included.


MEASUREMENT RULES

SUNDRIES
Q.30 Generally
1. Draining and refilling existing system shall be given
as a provisional or prime cost sum.

2. Disconnecting, setting aside and refixing equipment


for the convenience of other trades shall be given
as an item stating the relevant particulars.
MEASUREMENT RULES
SUNDRIES
Q.30 Generally
3. Temporarily operating each installation (except for
testing) shall be given as an item stating any
required qualifications of the attendant, the duration
of the operating period in hours and the purpose
and particulars of any special insurance cover
required by the Employer. Provision of solid fuel,
liquid fuel, gas and electricity for power and lighting
shall be deemed to be included with the item
MEASUREMENT RULES
SUNDRIES
Q.30 Generally
4. Testing each installation shall be given as an item stating any
required qualifications of the attendant, the number of stage
tests in addition to the final, the purpose of the tests, the
instruments and appliances required to be provided and
particulars of any special insurance cover required by the
Employer. Provision of solid fuel, liquid fuel, gas and electricity
for power and lighting shall be deemed to be included with the
item.

5. Preparing plans or diagrams of the installations as fitted shall


be given as an item stating the kind of information required to
be shown and the number of copies of each drawing required
to be provided.
SCHEMATIC DRAWING

1.Heat Detector
2.Smoke Detector 6. Alarm Bell
3.Extinguishing Nozzles 7. Key Switch
4.Fire Curtain (for Louver Door / 8. Double Inter-lock Control
Opening) Panel c/w Back
5. CO2 Cylinder c/w Accessories 9. Normal / Discharge Light
MEASUREMENT RULES
BUILDER’S WORK
Q.31 GENERALLY

1. Unless otherwise stated, all items of builder’s shall


be given in accordance with the appropriate
section.
2. Builder’s works in connection with plumbing and
mechanical engineering installations shall be
grouped together under an appropriate heading.
MEASUREMENT RULES
BUILDER’S WORK
Q.32 PARTICULARLY

1. Excavating trenches for pipes not exceeding 55mm


nominal size shall be given in accordance with
clause D.12.9

2. For pipe over 55mm shall be given in accordance


with clause V.2

3. Cutting away for making good after M&E works……


SUMMARY OF SMM
SUMMARY OF MEASUREMENT RULES
CLAUSE ELEMENT METHOD UNIT

Q.1.1 All element Shall be given in regulations, kind and quality


of material, gauge, thickness or substance of
material with any tests.
Q.1.2 Assembling and Connecting flanges and jointing shall include
jointing with the items.
Q.1.3 Patterns, moulds,
templets Shall be include with the items.

Q.1.4 Priming and Described the work whether applied before or


painting after fabrication or assembly.
Q.1.5 Nails, bolts, nuts,
holes, screws, In the description of work, stated the method of
plugs, shot-fired fixing.
pins
SUMMARY OF MEASUREMENT RULES
Q.1.6 a) building board
(a-f) b) timber
c) metal-faced or
composition-
Shall stated the method of fixing and including
faced timber
the necessary drilling of the backgrounds and
d) brickwork,
be given in the description.
concrete or
stonework
e) plain metal
f) glass
Q.1.7 Temporary work Shall be include with the items ( removing
temporary work and making good )
Q.1.8 Connections Shall be given in the description the nature of
work, turning off supplies of any restriction
when breaking into existing pipes.
Q.2.1 d) fire fighting Given under an appropriate heading with its
installation metalwork and supports.
SUMMARY OF MEASUREMENT RULES
Q.3.1 All element The location for the work that must be
identified :
i) internally
ii) externally
iii) in plant rooms
Q.8.1 Pipes Measured all over the pipe fittings, short M
running lengths and branches stating the type
and nominal size. Separate it if it is purpose-
made pipe. Curved pipe stating the radius.
Joints shall be given in the description stating
the method of jointing.
Q.8.2 Joints of a special Shall be described as extra over Nos.
characters and extra
demountable
couplers
Q.8.3 Flexible pipes and Measured as fully extended and shall each be
extensible pipes so described.
Q.8.4 Pipes laid or fixed in Shall be described.
ducts, trenches and
chases
SUMMARY OF MEASUREMENT RULES
Q.8.5 Flow and return All measurement stating the length, type and Nos.
header pipe nominal size of the main pipe and branch pipe
and also method of construction and jointing
the ends.
Q.8.6 Pipe fittings and All details, cutting and jointing shall be Nos.
purpose made pipe described.
fittings
Q.8.7 Expansion loops All measurement stating the limiting dimensions Nos.
and the amount of expansions to be
accommodated.
Q.8.8 Expansion All measurement stating the type of joint and Nos.
compensators the amount of expansions to be
accommodated.
Q.8.9 Flanges and unions Necessary solely for erection purposes shall
included.
Q.8.10 Jointing All jointing shall be deemed included with the
items.
Q.8.11 Fittings and jointing All measurements stating he size and kind of Nos.
pipe flanged concerned perforating
SUMMARY OF MEASUREMENT RULES
Q.9.1 Special connections Measured separately stating nominal size,
Special joints in pipes kind of pipe, method of jointing and must
be classify
a) Connections between pipes of different
materials and difference grades and of the
same material.
b) Connections between pipes and
appliances or equipment.
c) Connections to existing pipes.
Q.9.2 Isolated joints As extra over stating the type of jointing
Q.10 Made bends, made Shall included with the pipes on which they
springs, made offsets, occur.
beaded ends,
ornamental ends, etc.
Q.12.1 Standard pipe Shall described on the description of the pipes
supports stating the type and spacing.
Q. 12.2 Non-standard pipe Shall be described. Nos.
supports
Q.12.3 Supports that are Shall described stating the type of lining
lined to insulate pipes material.
SUMMARY OF MEASUREMENT RULES

Q.12.4 Clips, saddles, pipe- Enumerated separately stating the type and size Nos.
hooks, holderbats,
brackets, rollers,
chairs, hangers/black
plates,
Gender-laps
Q.12.5 Pipe anchor Enumerated separately stating nominal size of Nos.
pipe, type and size of components, method of
fixing of the pipe and nature of work.
Q.13 Connection Work which may only carried out by Public P.S
Undertaking or Local Authority.
SUMMARY OF MEASUREMENT RULES
Q.15.1 Special connections, Enumerated separately stating the size, kind Nos.
special joints of ducting and also method of jointing ,
classify ;
a) Connections between ducting of differing
materials.
b) Connections between ducting and
equipment stating the nature of the
equipment.
c) Isolated joints which differ from those
given in the description of the ducting.
d) Flexible connections between ducting and
plant.
Q.15.2 Ducting turn and Enumerated separately stating type and Nos.
splitters material size of ducting
Q.15.3 Nozzle outlets, test Shall described stating size, method of jointing Nos.
holes and cores and material and thickness or gauge
access doors
Q.15.4 Cowls, terminals, Stating size and type, size of ducting and Nos.
intake louvers method of jointing.
Taking off list
_______________________________________________________________________________________________________________________

1.Hose Reel System 3.Brass Work


Swing hose reel Ball float valve
Water tank Strainer valve
Electrical duty pump Stop valve
Diesel standby pump Flexible connection
Alarm bell Check valve
Gate valve
Pressure gauge

2.Pipe Work 4.Connection To Public Main


Incoming pipe 5.Builder’s work
Distribution pipe
6.Testing
Rising pipe
Painting to pipe
Taking off List
_______________________________________________________________________________________________________________________

No. ITEM CLAUSE UNIT


1. Hose Reel System
Swing hose reel
Water tank
Electrical duty pump Q.19.1 Nos.
Diesel standby pump
Alarm bell
Taking off List
_______________________________________________________________________________________________________________________

No. ITEM CLAUSE UNIT


2. Pipe Work
Incoming pipe M
Distribution pipe Q.7, Q.8.1
Rising pipe
Painting to pipes Item
Pipe fittings Q.8.6 Nos.
Taking off List
_______________________________________________________________________________________________________________________

No. ITEM CLAUSE UNIT


3. Brass Work
Ball float valve
Strainer valve
Stop valve
Flexible connection Q.19.1 Nos.
Check valve
Gate valve
Pressure gauge
Taking off List
_______________________________________________________________________________________________________________________

No. ITEM CLAUSE UNIT


4. Connection to public Q.13 Provisional
main Sum

5. Builder’s work Q.31, Q.32.1

6. Testing Q.30.4
Item
TAKING OFF
LIST
1. Hose reel. -No
2. Water storage tank. -No
3. Electrical duty pump. -No
4. Diesel standby pump -No
5. Incoming pipe. -M
6. Main distribution pipe .-M
7. Rising main pipe. -M
8. Distribution pipe. -M
9. Suction pipe. -M
10. Drain pipe.- M
11. Ball float valve. -No
12. Strainer valve. -No
13. Stop valve. -No
14. Flexible connection. -No
15. Check valve. -No
16. Pressure gauge. -No
17. Pressure switch. -No
18. Automatic air release valve. -No
19. Cables. -M
20. Testing -item
1. Main fire alarm console panel. -No
2. Manual break glass. -No
3. Fire Alarm Bell. -No
4. Heat detector. -No
5. Smoke detector. -No
6. Cables. -No
7. Testing -item.
TAKING-OFF LIST
1. Preambles
2. Builder’s work
i.Exc.trench to receive hydrant pipe M
ii.Exc.trench to receive incoming pipe M
3. Pipework
i.For pillar hydrant
- 150mm dia. MSCL pipe laid in trench M
ii.For incoming pipe
- 150mm dia. MSCL pipe laid in trench M
- 150mm dia. MSCL pipe laid on slab M
- 150mm dia. MSCL pipe fixed to wall M
iii.For pump house
- 200mm dia. MSCL pipe laid on slab M
- 50mm dia. MSCL pipe laid on slab M
- 200mm dia. MSCL pipe fixed to wall M
- 50mm dia. MSCL pipe fixed to wall M
- 150mm dia. MSCL pipe fixed to wall M
TAKING-OFF LIST (Cont’d)
3. Pipework (cont’d)
iv.For hosereel
- 50mm dia. G.I pipe fixed to wall M
- 25mm dia. G.I pipe fixed to wall M
v.For sprinkler
- 150mm dia. G.I pipe fixed to ceiling M
- 100mm dia. G.I pipe fixed to ceiling M
- 80mm dia. G.I pipe fixed to ceiling M
- 65mm dia. G.I pipe fixed to ceiling M
- 50mm dia. G.I pipe fixed to ceiling M
- 45mm dia. G.I pipe fixed to ceiling M
- 32mm dia. G.I pipe fixed to ceiling M
- 25mm dia. G.I pipe fixed to ceiling M
- 150mm dia. G.I pipe fixed to wall M
- 25mm dia G.I drain pipe fixed to wall M
vi.Brasswork
- Gate valve NO
- Alarm valve NO
TAKING-OFF LIST (Cont’d)
Pipework (cont’d)
vii.Breeching inlet NO
4. Pillar Hydrant NO
5. Hose Reel System
i.Swing hose reel NO
ii.Electrical duty pump NO
iii.Diesel standby pump NO
6. Sprinkler System
i.Sprinkler head NO
ii.Sprinkler tank NO
iii.Electrical duty pump NO
iv.Electrical jockey pump NO
v.Diesel standby pump NO
7. Conduits
i. 2 x 2.5mm2 PVC cable in metal conduit M
ii. 2 x 1.5mm2 PVC cable in metal conduit M
8. Cable
i. 2 x 2.5mm2 PVC cable in metal conduit M
ii. 2 x 1.5mm2 PVC cable in metal conduit M
TAKING-OFF LIST (Cont’d)

9. Fire Alarm System


i.Control gear NO
ii.Junction box NO
iii.Manual break glass NO
iv.Fire alarm bell NO
v.Heat detector NO
vi.Smoke detector NO
10. Portable Fire Extinguisher
i.Dry powder extinguisher NO
ii.CO2 extinguisher NO
11. Testing ITEM
FIRE FIGHTING SYSTEM
TAKING OFF LIST UNTUK HOSE REEL SYSTEM.

1. Builder’s Work
 a) Excavation M
2. Hose Reel System
 a) Swing hose- reel No
 b) Water storage tank No
 c) Electrical duty pump No
 d) Diesel duty pump No
 e) Piping: incoming pipe M
rising pipe M
distribution pipe M
3. Fire Alarm Panel
 Manual Break Glass NO
 Fire Alarm Bell NO
 Batteries NO
 Batery Charger NO
FIRE FIGHTING SYSTEM
TAKING OFF LIST UNTUK HOSE REEL SYSTEM.

4. Brasswork
 Air release valve No
 Gate valve No
 Check valve No
 Strainer valve No
 Flexible joint No
5. Equipment and Ancillaries
 Concrete plinth M2
6. Pipe Support
 Pipe hanger NO
7. Sundries
 Testing Item
Fire fighting
Installation system

Bill of Quantities
ITEM DESCRIPTION UNIT QTY RATE RM CENT

FIRE FIGHTING INSTALLATION, TESTING,


COMMISSIONING AND MAINTENANCE OF
FIRE FIGHTING SYSTEM.

HOSE REEL SYSTEM

Swing hose-reel complete with 25mm diameter x No. 20


30mm long hose,12.5mm diameter nozzles, fixing,
bracket, reducer, gate valve and other accessories as
described.

Hot-dipped galvanized pressed steel water storage No. 1


tank of approved type, manufactured to BS 1564,
3.66m x 2.44m x 1.22m height with 2400 gallons
capacity, complete with float valve, level indicator,
ladder, overflow pipe and drain pipe, at approximately
1000mm high above ground level.

Electrical duty pump, 30 igpm, 150 ft. head. No. 1


Diesel standby pump, 32 igpm, 160 ft. head. No. 1
TESTING
Allow for testing the foregoing fire fighting system,
Item
make good any defects and leave the whole of the
installation in perfect working order to the
satisfaction of the S.O and Local Authority.
Preambles

The drawing where the drawing no.


FNP/BL/0205/F01-04 shows the layout of the fire
fighting system.All quantities are all provisional
subject to remeasurement upon combination

construction of the said item.


The fire fighting system to be excuted by the
contractor in accordance to Jabatan Bomba
Malaysia requirement and approval.
All wiring to brickwall and soffit of ceiling shall
be concealed unless otherwise stated and all
wiring above ceiling space of roof level shall be in
galvanised iron conduit and coloured by red.
The item of this bill not fully described and the
rates shall be held to include for all short running,
bend,tees,joints,valve,reducer,backnuts and the
like.The contractor must allow for testing fire
fighting system and handling over the test
certificate to the architect.
The contractor shall be provide for obtaining all
necessary plan.
ITEM DESCRIPTION UNI QTY RATE RM CENT
T
FIRE FIGHTING INSTALLATION, TESTING,
COMMISSIONING AND MAINTENANCE OF
FIRE FIGHTING SYSTEM.

HOSE REEL SYSTEM

Swing hose-reel complete with 25mm diameter x No. 20


30mm long hose,12.5mm diameter nozzles, fixing,
bracket, reducer, gate valve and other accessories as
described.

Hot-dipped galvanized pressed steel water storage No. 1


tank of approved type, manufactured to BS 1564,
3.66m x 2.44m x 1.22m height with 2400 gallons
capacity, complete with float valve, level indicator,
ladder, overflow pipe and drain pipe, at
approximately 1000mm high above ground level.

Electrical duty pump, 30 igpm, 150 ft. head. No. 1


Diesel standby pump, 32 igpm, 160 ft. head.
No. 1
TESTING
Allow for testing the foregoing fire fighting system,
Item
make good any defects and leave the whole of the
installation in perfect working order to the
satisfaction of the S.O and Local Authority.
APARTMENT J.B
Description QTY Unit Rate RM SEN
ELEMENT FIRE FIGHTING INSTALLATION
Fire-Fighting in connecting (internally)
Fire Alarm system
A Manual Break glass fire alarm with 24 volts 6 NO
D.C supply, mounted at wall as described

B 150 mm Diameter fire alarm bell with 24 6 NO


volts D.C supply, mounted as described

Fire Fighting Equipment


Lighting Installation (internally)
C KELUAR' Sign complete with nickel 8 NO
Cadmium batteries, tuber, etc and
accessories with approved 13 W
non-contained fluorescent

D Self contained Emergency Light fitting 8 NO


complete with nickel cadmium battery and
outomatic charger unit similar econ lite

Hose Reel system

E Hot Dipped Galvanised Pessed Steel Water 1 NO


Storage Tank of approved type,
manufactured to BS 1564, 3m x 2m x 2m
height with 2640 Gallons capacity,
complete with 50 diameter overflow
pipe,suction pipe, drain pipe incoming pipe
at approximately 100 mm above ground
level

F 1" Diameter Swing Type Hydraulic hose reel 6 NO


drums each c/w diameter x 100 ft. non.
Kink double braided tubing and 1" diameter
3 jet spray nozzle

G Electrical Duty Pump, 30 IGPM, 120 ft head 1 NO

H Diesel Standby Pump, ditto 1 NO

Galvanised Iron class 'B' Tubing to comply


with BS 1387, screw socket together

K 50 mm Diameter incoming pipe, at High 2.00 M


level free standing

L 50 mm Diameter overflow pipe,ditto 4 M


APARTMENT J.B
Description QTY Unit Rate RM SEN
Galvanised Iron class 'B' Tubing to comply
with BS 1387, screw socket together
A 50 mm Diameter suction pipe at low level, 1 M
free standing

B 25 mm Diameter riser pipe fixed to brickwall 3 M

C 50 mm Diameter drain pipe at low level and 2 M


jointing to Galvanised iron pipe

Brasswork To Comply With BS 1010 as described :-


D 50 mm Diameter flexible connection and 2 NO
jointing to galvanised iron pipe

E 50 mm Diameter Check valve, ditto 2 NO

F 50 mm Diameter stop valve, ditto 2 NO

G 50mm Diameter Ball float valve, ditto 2 NO

H 50mm Diameter gate valve, ditto 2 NO

J 50mm Diameter outomatic air release valve, 2 NO


ditto

K 50mm Diameter pressure gauge, ditto 1 NO

L 50mm Diameter stairer valve, ditto 2 NO

BUILDER'S WORK

M Wire brush and painting primer, undercoat Item


and two coat gloss oil to surface of
galvanised iron pipe

N Installation inclusive of hacking, punching of Item


holes in wall and floors, coring of holes
through reinforce concrete slab and making
good

Testing

O Allow for testing foregoing fire fighting Item


system, make good and any defects and
leave the whole of the installation in perfect
working order to the satisfaction of the S.O
and Local Authority
PROJEK
Cadangan Merekabentuk, Membina &
Menyiapkan SMK Kenangan, Segamat, Johor,
Di atas Lot 5848, 2259 Sebahagian Lot 5848
dan Sebahagian Lot 2258.
PEJABAT LLM WILAYAH TIMUR BERSERTA KEM DI INTERCHANGE KUANTAN.

ITEM DESCRIPTION UNIT QTY RATE RM

ELEMENT : FIRE FIGHTING INSTALLATION


(INTERNALLY)

PREAMBLE ( All Provisional )

A The fire fighting installation is to be executed by contrator


in accordance with Jabatan Bomba requirement and approval.
Where items in this bill are not fully describes the rates shall
be held to include for all piping, control gear and etc all as
described or as required by Jabatan Bomba as being
appropriate for installation. The rates be held to include for all
short running lengths, bends, tees and etc. The contractor
must allow for testing the fire fighting installation and handling
over the test certifiate to the Architect. (Q.1) Item

HOSE-REEL SYSTEM

B Hydraulic hose-reel complete with 36 mm x 25 mm diameter


long hose, 12.5 mm diameter nozzles, fixing, bracket,
reducer, gate valve and other accessories as described.
(Q.19) No 1

C Electrical duty pump with 30 IGPM at 135 feet head. (Q.19) No 1

D Diesel standby pump with 130 IGPM at 135 feet head. (Q.19) No 1

Galvanised Iron Class 'B' Tubing to Comply With BS 1387


Screw Socketed Together Including All Necessary Short
Length, Fire Bends, Tees, Dimishing Pieces, Plugs and
The Like as Described.

E 50 mm Diameter incoming pipe laid in trench. (Q.8) M 13

F 50 mm Diameter distribution pipe laid in ground slab. (Q.8) M 17

G 50 mm Diameter distribution pipe fixed in ceiling space


horizontally with approved brackets. (Q.8) M 23

H 50 mm Diameter distribution pipe fixed to brickwall vertically


with approved brackets. (Q.8) M 17

J 25 mm Diameter distribution pipe fixed to hidraulic hose-reel.


(Q.8) M 1

K EXTRA OVER 50 mm Diameter elbow. (Q.8.1) No 11

TO COLLECTION
FF / 01
PEJABAT LLM WILAYAH TIMUR BERSERTA KEM DI INTERCHANGE KUANTAN. (CONT'D)

ITEM DESCRIPTION UNIT QTY RATE RM

ELEMENT : FIRE FIGHTING INSTALLATION


(INTERNALLY)

A EXTRA OVER 50 mm Diameter tee. (Q.8.1) No 1

B EXTRA OVER 25 mm Diameter elbow. (Q.8.1) No 2

C 12 mm Diameter mild steel brackets at 600 mm centres


to centres to support galvanised iron pipe. (Q.12.4) No 68

Brasswork to Comply with BS 1010 as Described.

D 50 mm diameter gate valve and jointing to galvanised iron


pipe. (Q.19) No 6

E Hot-dipped galvanised pressed steel water storage tank


opproved type, manufactured to BS 1564, 12' x 4' x 8' height
with 1000 gallons capacity, complete with float valve, level
indicator, ladder, overflow pipe and drain pipe at ground level.
(Q.19) No 1
Sundries

F Testing and commissioning the hose-reel system as


described in the specification. (Q.30.4) Item

PORTABLE FIRE EXTINGUISHER

G 9 kg ABC extinguisher dry powder bomba approved type


manufactured to BS 5306, complete with brackets and
accessories. (Q.19) No 7

Sundries

H Testing and commissioning the portable fire extinguisher


as described in the specification. (Q.30.4) Item

FIRE ALARM SYSTEM

J 150 mm Diameter fire alarm bell with 24 V (D.C) supply


mounted at wall as described. (Q.19) No 2

K Manual break glass fire alarm size 84 mm x 115 mm with


24 V (D.C) supply mounted at wall as described. (Q.19) No 2

PVC Insulated Cable Drawn into Concealed Galvanised


Iron Conduit. (measured separately)

L 2 x 2.5 mm2 cable. (Q.19.4) M 54


TO COLLECTION
FF / 02
PEJABAT LLM WILAYAH TIMUR BERSERTA KEM DI INTERCHANGE KUANTAN. (CONT'D)

ITEM DESCRIPTION UNIT QTY RATE RM

ELEMENT : FIRE FIGHTING INSTALLATION


(INTERNALLY)

Galvanised Iron Class 'B' Conduit with Screw Joints


Including All Short Running Length, Bends, Tees, Saddles
Crampets, Locknuts, Circular Boxes as Described.

A 50 mm Diameter conduit, chase into brickwall vertically


with approved bracket. (Q.19.4) M 17

B 50 mm Diameter conduit, fixed in ceiling space with


approved bracket. (Q.19.4) M 37

Sundries

C Testing and commissioning the fire alarm system as


described in the specification. (Q.30.4) Item

BUILDER'S WORK

D Excavate trench to receive 50 mm diameter incoming pipe,


maximum depth nearest to 0.25 m including filling in,
compaction and disposal of surplus soil as desribed. (Q.32.1) M 18

E 600 mm thick vibrated reinforced conrete grade 20 as


concrete plinth including all necessary formwork and
reinforcement. (F.3.19) m2

F Allow for testing the foregoing fire fighting installation,


make good any defect and leave the whole of the installation
in perfect working order to the satisfaction of the S.O and
Local Authority.
(Q.30.4) Item

TO SUMMARY
FF / 03
Taking Off list
 Builder’s Work
– Excavate trench to receive pipe - M
 Hose Reel System
– Swing hose reel - NO
– Water storage tank - NO
– Electrical duty pump - NO
– Diesel standby pump - NO
– Piping
 50 mm Diameter incoming pipe - M

 50 mm Diameter rising pipe – M

 50 mm Diameter distribution pipe - M

– Brasswork
 50 mm Diameter air release valve – NO

 50 mm Diameter gate valve – NO

 50 mm Diameter check valve – NO

 50 mm Diameter strainer valve – NO

 50 mm Diameter flexible joint – NO

 25 mm Diameter gate valve – NO


– Cable
 2 x 1.5 mm2 cable
 2.5 mm2 cable

 Fire Alarm System


– Control gear – NO
– Junction box – NO
– Manual break glass – NO
– 2 x 2.5 mm cable – M
– 50 mm Diameter conduit – M
 Portable Fire Extinguisher
– 9 kg Fire extinguisher - NO
– Hydrant Hose Cabinet – NO
 Lighting Installation
– Keluar sign - NO
– 5A Emergency light – NO
 Testing
– Allow for testing the foregoing fire fighting system - ITEM
Taking Off List

1. Pumps. - No
2. Pipeworks. -M
3. Tee - No
4. Bend. - No
5. Valves and ancillaries. - No
6. Hydrant box. - No
7. Pillar. - No
8. Fire Extinguisher. - No
9. Electrical Works. - No
10. Testing. - Item
1. Pumps - No

Equipment - Pumps

Electric Fire pump, end suction centrifugal

type with capacity of 750 GPM, 7 bar, 81 Kw/

108.7 Bhp. No 1

1 (PU 202)
2. Pipeworks

150mm dia. Black steel pipe, ERW. Sch 40,


embedded in in situ concrete m 130.00

130.00 (Pump Room) Length


75,000
55,000
130,000
3. Fitting and Accessories

Tees

EXTRA OVER 150x150x65mm Black steel tee. No 5

5 L.Basement

Bend

EXTRA OVER Bend 90˚, to 150mm dia Black No 1


steel pipe

1 L.Basement
4.Hydrant
Hydrant

Indoor hydrant box size 800x1300x300mm,


complete with house rack, hydrant valve and
fire
house type 40x25m. No 12

3 L.Basement
3
3 L. Dasar
3
3 L. 1
3
3 L. 2
3

12
5. Fire Extinguisher

Fire extinguisher capacity 3 Kg complete with


box, and all necessary supporting fixing

accessories as specified. No. 52

4 13 L.B - L.2
52
6. Testing

Allow for checking, testing, acceptance testing


and commisioning the Fire Protection Installation. Item

7. Maintenance

Allow for service and maintenance of the complete


installations during 12 months Defects Liability
Period, excluding any maintenance resulting from
defective workmanship or materials requiring repair
and/or replacement by contractor. Item
Item Description Unit Rate Qtty RM
Element Fire Fighting Installation

Builder's Work

A
Excavate trench to receive 150mm diameter
m 17
incoming pipe, maximum depth not
exceeding 1.0m including filling in,
compaction and disposal of surplus soil as
required.

B m 7
Excavate trench to receive 50mm diameter
Galvanised Iron class 'B' incoming pipe,
maximum depth not exceeding 1.0m
including filling in, compaction and disposal
of surplus soil as described.

Hose Reel System

A no 1
Swing type hose reel drum with corrugated
hose 30.5x25mm diameter complete with
valve, bracket, 12.5mm diameter nozzle and
other accessories as described.

B no 1
Hose reel cabinet type SRI model HRS 045
or equivalent for all hose reel drum

C no 1
Electrical duty pump with the capacity of 30
igm againts 170 ft static head complete with
wiring, pump plinth and other accessories

D no 1
Diesel standy pump with the capacity of 30
igm againts 170 ft static head complete with
wiring, pump plinth and other accessories.

E One (1) nos of 2400 gallons of hose reel no 1


water tank, 6mm thick press steel panel
complete with ball valve, fittings, level
indicator, float control, piping, external red
paint, internal asnd external ladder and other
accessories.

To collection
Item Description Unit Rate Qtty Rm

Galvanised Iron Class 'B' Tubing Screw


Socketed Together Including All Necessary
Short Length, Sockets, Connectors,
Backnuts, Elbows And The Likes As
Described

A 150mm Diameter incoming pipe laid in trench m 17


(m/s)

B 50mm Diameter incoming pipe embedded m 5


into ground floor slab

C 50mm Diameter incoming pipe fixed to m 2


brickwall

Brasswork To Comply To BS 1010 As


Described

A 50mm Diameter air release valve and jointing no 1


to galvanised iron pipe

B 50mm Diameter check valve and jointing to no 2


galvanised iron pipe

C 65mm Diameter gate valve and jointing to no 5


galvanised iron pipe

To collection
Item Description Unit Rate Qtty Rm
Fire Alarm System Installation

A Main fire alarm console panel (6 zones) no 1


complete with LED mimic diagram, battery
compartment complete with 8 AHx24V and
charger as manufacturer's detail.

B 400x400x150mm fixed to wall junction box no 1


approved type and quality, complete with
3mm thick galvanised steel covers, gasket
and all other necessary accessories.

C Manual break glass fire alarm size no 1


84mmx115mm with 24v(d.c) supply mounted
at wall as described

D no 1
150mm Diameter fire alarm bell with 24v
(d.c) suplly mounted at wall as described

Testing

A Allow for testing the foregoing fire fighting Item


system, make good any defect and leave the
whole installation in perfect working order to
the satisfaction of the superitandant officer.