Download as docx, pdf, or txt
Download as docx, pdf, or txt
You are on page 1of 39

CAPILLARY PRESSURE RESULTS

Fluid System :
Test Method :
Overburden Pressure :

Drainage Imbibition
Capillary Water Capillary Water
Sample Depth Perm. to Porosity
pressure saturation pressure saturation
no. (m) air (md) (%)
(psi) (% pv) (psi) (% pv)

0 1 -5 0.748
0.1 0.99 -3 0.735
0.25 0.85 -2 0.728
0.5 0.6 -1 0.721
0.75 0.45 -0.75 0.715
1 0.36 -0.5 0.699
2 0.31 -0.25 0.625
3 0.29 -0.1 0.55
5 0.28 0 0.28
CAPILLARY PRESSURE RESULTS

Fluid System :
Test Method :
Overburden Pressure :

Drainage Imbibition
Capillary Water Capillary Water
Sample Depth Perm. to Porosity
pressure saturation pressure saturation
no. (m) air (md) (%)
(psi) (% pv) (psi) (% pv)

0 1 -5 0.759
0.1 0.99 -3 0.735
0.25 0.97 -2 0.719
0.5 0.62 -1 0.71
0.75 0.42 -0.75 0.705
1 0.33 -0.5 0.681
2 0.26 -0.25 0.625
3 0.24 -0.1 0.55
5 0.205 0 0.205
CAPILLARY PRESSURE RESULTS

Fluid System :
Test Method :
Overburden Pressure :

Drainage Imbibition
Capillary Water Capillary Water
Sample Depth Perm. to Porosity
pressure saturation pressure saturation
no. (m) air (md) (%)
(psi) (% pv) (psi) (% pv)

0 1 -5 0.754
0.1 0.99 -3 0.732
0.25 0.89 -2 0.719
0.5 0.7 -1 0.711
0.75 0.51 -0.75 0.703
1 0.38 -0.5 0.685
2 0.29 -0.25 0.625
3 0.25 -0.1 0.56
5 0.223 0 0.223
CAPILLARY PRESSURE RESULTS

Fluid System :
Test Method :
Overburden Pressure :

Drainage Imbibition
Capillary Water Capillary Water
Sample Depth Perm. to Porosity
pressure saturation pressure saturation
no. (m) air (md) (%)
(psi) (% pv) (psi) (% pv)

0 1 -5 0.734
0.1 0.99 -3 0.721
0.25 0.85 -2 0.711
0.5 0.58 -1 0.699
0.75 0.36 -0.75 0.689
1 0.31 -0.5 0.672
2 0.265 -0.25 0.615
3 0.24 -0.1 0.52
5 0.211 0 0.211
CAPILLARY PRESSURE RESULTS

Fluid System :
Test Method :
Overburden Pressure :

Drainage Imbibition
Capillary Water Capillary Water
Sample Depth Perm. to Porosity
pressure saturation pressure saturation
no. (m) air (md) (%)
(psi) (% pv) (psi) (% pv)

0 1 -5 0.776
0.1 0.99 -3 0.751
0.25 0.97 -2 0.739
0.5 0.79 -1 0.725
0.75 0.56 -0.75 0.721
1 0.48 -0.5 0.715
2 0.38 -0.25 0.68
3 0.35 -0.1 0.49
5 0.321 0 0.321
CAPILLARY PRESSURE RESULTS

Fluid System :
Test Method :
Overburden Pressure :

Drainage Imbibition
Capillary Water Capillary Water
Sample Depth Perm. to Porosity
pressure saturation pressure saturation
no. (m) air (md) (%)
(psi) (% pv) (psi) (% pv)

0 1 -5 0.747
0.1 0.99 -3 0.728
0.25 0.95 -2 0.712
0.5 0.69 -1 0.702
0.75 0.55 -0.75 0.691
1 0.49 -0.5 0.679
2 0.44 -0.25 0.591
3 0.42 -0.1 0.48
5 0.392 0 0.392
SECTION 5

PAGE

Unsteady-State Gas-Oil Relative Permeability 5-1


SUMMARY OF GAS - OIL RELATIVE PERMEABILITY TEST RESULTS
Unsteady-State Method Extracted State Sample
Net Confining Stress: Temperature:

Initial Conditions Terminal Conditions

Sample Permeability Oil Recovery,


Sample Depth, to Air, Porosity, Water Effective Oil Effective Relative
Number meters millidarcys fraction Saturation, Permeability Saturation, Permeability Permeability
fraction to Oil, fraction to Gas, to Gas, fraction fraction
pore space millidarcys pore space millidarcys fraction* pore space oil-in-place

* Relative to the effective permeability to oil at initial water saturation


GAS - OIL RELATIVE PERMEABILITY
Unsteady-State Method Extracted State Sample
Net Confining Stress: Temperature:

Sample Number:
Sample Depth, meters:
Permeability to Air, md:
Porosity, fraction:
Initial Water Saturation, fraction:
Effective Oil Permeability at Swi, md:

Gas Gas-Oil Relative Relative Relative Fractional Flow


Saturation, Permeability Permeability Permeability of Gas,
fraction Vp Ratio to Gas*, to Oil*, fg
fraction fraction
0.000 0.000 0.000 0.900 0.000
0.050 0.000 0.000 0.693 0.000
0.119 0.000 0.000 0.464 0.008
0.188 0.001 0.000 0.292 0.464
0.256 0.013 0.002 0.169 0.945
0.325 0.144 0.013 0.087 0.995
0.394 1.304 0.048 0.037 0.999
0.463 13.144 0.142 0.011 1.000
0.531 265.170 0.359 0.001 1.000
0.600 0.800 0.000 1.000

*Relative to the effective permeability to oil at initial water saturation.


GAS - OIL RELATIVE PERMEABILITY
Unsteady-State Method Extracted State Sample
Net Confining Stress: Temperature:
Sample Number:
Sample Depth, meters:
Permeability to Air, md:
Porosity, fraction:
Initial Water Saturation, fraction:
Effective Oil Permeability at Swi, md:
GAS - OIL RELATIVE PERMEABILITY
Unsteady State Method Extracted State Sample
Net Confining Stress: Temperature:

Sample Number:
Sample Depth, meters:
Permeability to Air, md:
Porosity, fraction:
Initial Water Saturation, fraction:
Effective Oil Permeability at Swi, md:

Gas Gas-Oil Relative Relative Relative Fractional Flow


Saturation, Permeability Permeability Permeability of Gas,
fraction Vp Ratio to Gas*, to Oil*, fg
fraction fraction
0.000 0.000 0.000 0.878 0.000
0.038 0.000 0.000 0.738 0.000
0.116 0.000 0.000 0.495 0.008
0.194 0.001 0.000 0.313 0.456
0.272 0.013 0.002 0.182 0.942
0.351 0.137 0.013 0.093 0.994
0.429 1.224 0.048 0.040 0.999
0.507 12.191 0.144 0.012 1.000
0.585 242.059 0.362 0.001 1.000
0.664 0.805 0.000 1.000

*Relative to the effective permeability to oil at initial water saturation.


GAS - OIL RELATIVE PERMEABILITY
Unsteady State Method Extracted State Sample
Net Confining Stress: Temperature:
Sample Number:
Sample Depth, meters:
Permeability to Air, md:
Porosity, fraction:
Initial Water Saturation, fraction:
Effective Oil Permeability at Swi, md:
GAS - OIL RELATIVE PERMEABILITY
Unsteady State Method Extracted State Sample
Net Confining Stress: Temperature:

Sample Number:
Sample Depth, meters:
Permeability to Air, md:
Porosity, fraction:
Initial Water Saturation, fraction:
Effective Oil Permeability at Swi, md:

Gas Gas-Oil Relative Relative Relative Fractional Flow


Saturation, Permeability Permeability Permeability of Gas,
fraction Vp Ratio to Gas*, to Oil*, fg
fraction fraction
0.000 0.000 0.000 0.946 0.000
0.071 0.000 0.000 0.613 0.000
0.136 0.000 0.000 0.384 0.022
0.202 0.002 0.000 0.220 0.719
0.268 0.045 0.005 0.112 0.983
0.333 0.613 0.029 0.047 0.999
0.399 8.088 0.110 0.014 1.000
0.465 199.789 0.331 0.002 1.000
0.530 0.840 0.000 1.000

*Relative to the effective permeability to oil at initial water saturation.


GAS - OIL RELATIVE PERMEABILITY
Unsteady State Method Extracted State Sample
Net Confining Stress: Temperature:
Sample Number:
Sample Depth, meters:
Permeability to Air, md:
Porosity, fraction:
Initial Water Saturation, fraction:
Effective Oil Permeability at Swi, md:
GAS - OIL RELATIVE PERMEABILITY
Unsteady State Method Extracted State Sample
Net Confining Stress: Temperature:

Sample Number:
Sample Depth, meters:
Permeability to Air, md:
Porosity, fraction:
Initial Water Saturation, fraction:
Effective Oil Permeability at Swi, md:

Gas Gas-Oil Relative Relative Relative Fractional Flow


Saturation, Permeability Permeability Permeability of Gas,
fraction Vp Ratio to Gas*, to Oil*, fg
fraction fraction
0.000 0.000 0.000 0.883 0.000
0.031 0.000 0.000 0.757 0.000
0.117 0.000 0.000 0.473 0.018
0.202 0.002 0.000 0.272 0.672
0.287 0.035 0.005 0.138 0.979
0.373 0.477 0.027 0.058 0.998
0.458 6.231 0.104 0.017 1.000
0.544 152.966 0.312 0.002 1.000
0.629 0.785 0.000 1.000

*Relative to the effective permeability to oil at initial water saturation.


GAS - OIL RELATIVE PERMEABILITY
Unsteady State Method Extracted State Sample
Net Confining Stress: Temperature:
Sample Number:
Sample Depth, meters:
Permeability to Air, md:
Porosity, fraction:
Initial Water Saturation, fraction:
Effective Oil Permeability at Swi, md:
GAS - OIL RELATIVE PERMEABILITY
Unsteady State Method Extracted State Sample
Net Confining Stress: Temperature:

Sample Number:
Sample Depth, meters:
Permeability to Air, md:
Porosity, fraction:
Initial Water Saturation, fraction:
Effective Oil Permeability at Swi, md:

Gas Gas-Oil Relative Relative Relative Fractional Flow


Saturation, Permeability Permeability Permeability of Gas,
fraction Vp Ratio to Gas*, to Oil*, fg
fraction fraction
0.000 0.000 0.000 0.891 0.000
0.058 0.000 0.000 0.674 0.000
0.132 0.000 0.000 0.454 0.009
0.205 0.001 0.000 0.287 0.489
0.279 0.014 0.002 0.167 0.949
0.353 0.155 0.013 0.086 0.995
0.426 1.384 0.051 0.037 0.999
0.500 13.709 0.152 0.011 1.000
0.573 269.305 0.381 0.001 1.000
0.647 0.847 0.000 1.000

*Relative to the effective permeability to oil at initial water saturation.


GAS - OIL RELATIVE PERMEABILITY
Unsteady State Method Extracted State Sample
Net Confining Stress: Temperature:
Sample Number:
Sample Depth, meters:
Permeability to Air, md:
Porosity, fraction:
Initial Water Saturation, fraction:
Effective Oil Permeability at Swi, md:
GAS - OIL RELATIVE PERMEABILITY
Unsteady State Method Extracted State Sample
Net Confining Stress: Temperature:

Sample Number:
Sample Depth, meters:
Permeability to Air, md:
Porosity, fraction:
Initial Water Saturation, fraction:
Effective Oil Permeability at Swi, md:

Gas Gas-Oil Relative Relative Relative Fractional Flow


Saturation, Permeability Permeability Permeability of Gas,
fraction Vp Ratio to Gas*, to Oil*, fg
fraction fraction
0.000 0.000 0.000 0.914 0.000
0.038 0.000 0.000 0.742 0.000
0.103 0.000 0.000 0.498 0.007
0.168 0.001 0.000 0.314 0.424
0.233 0.011 0.002 0.182 0.936
0.299 0.125 0.012 0.094 0.994
0.364 1.135 0.045 0.040 0.999
0.429 11.449 0.135 0.012 1.000
0.494 229.981 0.343 0.001 1.000
0.560 0.768 0.000 1.000

*Relative to the effective permeability to oil at initial water saturation.


GAS - OIL RELATIVE PERMEABILITY
Unsteady State Method Extracted State Sample
Net Confining Stress: Temperature:
Sample Number:
Sample Depth, meters:
Permeability to Air, md:
Porosity, fraction:
Initial Water Saturation, fraction:
Effective Oil Permeability at Swi, md:
SUMMARY OF FLUID PARAMETERS

Viscosity,
Fluid Temperature, °F centipoise Density, g/cm3
SECTION 6

PAGE

Unsteady-State Water-Oil Relative Permeability 6-1


SUMMARY OF WATER-OIL RELATIVE PERMEABILITY TEST RESULTS
Unsteady-State Method Extracted State Sample
Net Confining Stress: Temperature:

Initial Conditions Terminal Conditions


Oil
Permeability Recovery,
Sample Depth, to Air, Porosity, Effective Effective Relative
Number meters millidarcys fraction Water Permeability Oil Permeability Permeability
Saturation, to Oil, Saturation, to Water, to Water*, fraction fraction
fraction millidarcys fraction millidarcys fraction pore space oil-in-place

* Relative to the effective permeability to oil at initial water saturation


WATER - OIL RELATIVE PERMEABILITY
Unsteady State Method Extracted State Sample
Net Confining Stress: Temperature

Sample Number:
Sample Depth, meters:
Permeability to Air, md:
Porosity, fraction:
Initial Water Saturation, fraction:
Effective Oil Permeability at Swi, md:

Water Water-Oil Relative Relative Permeability Relative Permeability Fractional Flow


Saturation, Permeability to Water*, to Oil*, of Water,
fraction Vp Ratio fraction fraction fw
0.200 0.000 0.000 0.900 0.000
0.220 0.000 0.000 0.813 0.000
0.293 0.000 0.000 0.545 0.008
0.365 0.009 0.003 0.343 0.175
0.438 0.080 0.016 0.198 0.650
0.510 0.492 0.050 0.102 0.920
0.583 2.847 0.122 0.043 0.985
0.655 19.927 0.253 0.013 0.998
0.728 295.346 0.469 0.002 1.000
0.800 0.800 0.000 1.000

*Relative to the effective permeability to oil at initial water saturation.


WATER - OIL RELATIVE PERMEABILITY
Unsteady State Method Extracted State Sample
Net Confining Stress: Temperature

Sample Number:
Sample Depth, meters:
Permeability to Air, md:
Porosity, fraction:
Initial Water Saturation, fraction:
Effective Oil Permeability at Swi, md:
WATER - OIL RELATIVE PERMEABILITY
Unsteady State Method Extracted State Sample
Net Confining Stress: Temperature:

Sample Number:
Sample Depth, meters:
Permeability to Air, md:
Porosity, fraction:
Initial Water Saturation, fraction:
Effective Oil Permeability at Swi, md:

Water Water-Oil Relative Relative Permeability Relative Permeability Fractional Flow


Saturation, Permeability to Water*, to Oil*, of Water,
fraction Vp Ratio fraction fraction fw
0.164 0.000 0.000 0.878 0.000
0.237 0.000 0.000 0.617 0.004
0.310 0.004 0.002 0.415 0.090
0.383 0.035 0.009 0.262 0.445
0.456 0.190 0.029 0.152 0.816
0.529 0.912 0.071 0.078 0.955
0.602 4.498 0.149 0.033 0.991
0.675 28.122 0.277 0.010 0.998
0.748 381.728 0.476 0.001 1.000
0.821 0.766 0.000 1.000

*Relative to the effective permeability to oil at initial water saturation.


WATER - OIL RELATIVE PERMEABILITY
Unsteady State Method Extracted State Sample
Net Confining Stress: Temperature:

Sample Number:
Sample Depth, meters:
Permeability to Air, md:
Porosity, fraction:
Initial Water Saturation, fraction:
Effective Oil Permeability at Swi, md:
WATER - OIL RELATIVE PERMEABILITY
Unsteady State Method Extracted State Sample
Net Confining Stress: Temperature:

Sample Number:
Sample Depth, meters:
Permeability to Air, md:
Porosity, fraction:
Initial Water Saturation, fraction:
Effective Oil Permeability at Swi, md:

Water Water-Oil Relative Relative Permeability Relative Permeability Fractional Flow


Saturation, Permeability to Water*, to Oil*, of Water,
fraction Vp Ratio fraction fraction fw
0.224 0.000 0.000 0.946 0.000
0.297 0.000 0.000 0.636 0.006
0.371 0.007 0.003 0.403 0.143
0.444 0.064 0.015 0.234 0.597
0.518 0.395 0.048 0.121 0.902
0.592 2.284 0.118 0.051 0.982
0.665 15.892 0.246 0.015 0.997
0.739 231.730 0.458 0.002 1.000
0.812 0.786 0.000 1.000

*Relative to the effective permeability to oil at initial water saturation.


WATER - OIL RELATIVE PERMEABILITY
Unsteady State Method Extracted State Sample
Net Confining Stress: Temperature:

Sample Number:
Sample Depth, meters:
Permeability to Air, md:
Porosity, fraction:
Initial Water Saturation, fraction:
Effective Oil Permeability at Swi, md:
WATER - OIL RELATIVE PERMEABILITY
Unsteady State Method Extracted State Sample
Net Confining Stress: Temperature:

Sample Number:
Sample Depth, meters:
Permeability to Air, md:
Porosity, fraction:
Initial Water Saturation, fraction:
Effective Oil Permeability at Swi, md:

Water Water-Oil Relative Relative Permeability Relative Permeability Fractional Flow


Saturation, Permeability to Water*, to Oil*, of Water,
fraction Vp Ratio fraction fraction fw
0.210 0.000 0.000 0.883 0.000
0.283 0.000 0.000 0.592 0.007
0.356 0.008 0.003 0.373 0.160
0.428 0.072 0.016 0.216 0.625
0.501 0.443 0.049 0.111 0.912
0.574 2.565 0.120 0.047 0.984
0.646 17.930 0.250 0.014 0.998
0.719 264.741 0.464 0.002 1.000
0.792 0.793 0.000 1.000

*Relative to the effective permeability to oil at initial water saturation.


WATER - OIL RELATIVE PERMEABILITY
Unsteady State Method Extracted State Sample
Net Confining Stress: Temperature:

Sample Number:
Sample Depth, meters:
Permeability to Air, md:
Porosity, fraction:
Initial Water Saturation, fraction:
Effective Oil Permeability at Swi, md:
SUMMARY OF FLUID PARAMETERS

Viscosity, Density,
Fluid Temperature, °F centipoise g/cm3
SECTION 7

PAGE

Steady-State Water-Oil Relative Permeability 7-1


SUMMARY OF WATER-OIL RELATIVE PERMEABILITY TEST RESULTS
Steady State Method Extracted State Sample
Net Confining Stress: Temperature:

Initial Conditions Terminal Conditions


Oil
Permeability Recovery,
Sample Depth, to Air, Porosity, Effective Effective Relative
Number meters millidarcys fraction Water Permeability Oil Permeability Permeability
Saturation, to Oil, Saturation, to Water, to Water*, fraction fraction
fraction millidarcys fraction millidarcys fraction pore space oil-in-place

* Relative to the effective permeability to oil at initial water saturation


WATER - OIL RELATIVE PERMEABILITY
Steady-State Method Extracted State Sample
Net Confining Stress: Temperature:

Sample Number:
Sample Depth, meters:
Permeability to Air, md:
Porosity, fraction:
Initial Water Saturation, fraction:
Effective Oil Permeability at Swi, md:

Water Water-Oil Relative Relative Permeability Relative Permeability Fractional Flow


Saturation, Permeability to Water*, to Oil*, of Water,
fraction Vp Ratio fraction fraction fw
0.201 0.000 0.000 0.891 0.000
0.270 0.000 0.000 0.627 0.003
0.340 0.004 0.002 0.421 0.076
0.409 0.029 0.010 0.266 0.402
0.479 0.160 0.032 0.155 0.788
0.549 0.767 0.078 0.080 0.947
0.618 3.793 0.163 0.034 0.989
0.688 23.838 0.303 0.010 0.998
0.757 326.779 0.519 0.001 1.000
0.827 0.834 0.000 1.000

*Relative to the effective permeability to oil at initial water saturation.


WATER - OIL RELATIVE PERMEABILITY
Steady-State Method Extracted State Sample
Net Confining Stress: Temperature:
Sample Number:
Sample Depth, meters:
Permeability to Air, md:
Porosity, fraction:
Initial Water Saturation, fraction:
Effective Oil Permeability at Swi, md:
WATER - OIL RELATIVE PERMEABILITY
Steady State Method Extracted State Sample
Net Confining Stress: Temperature:

Sample Number:
Sample Depth, meters:
Permeability to Air, md:
Porosity, fraction:
Initial Water Saturation, fraction:
Effective Oil Permeability at Swi, md:

Water Water-Oil Relative Relative Permeability Relative Permeability Fractional Flow


Saturation, Permeability to Water*, to Oil*, of Water,
fraction Vp Ratio fraction fraction fw
0.240 0.000 0.000 0.914 0.000
0.301 0.000 0.000 0.645 0.004
0.362 0.004 0.002 0.434 0.078
0.422 0.029 0.010 0.275 0.401
0.483 0.156 0.031 0.160 0.784
0.544 0.739 0.075 0.083 0.945
0.604 3.612 0.155 0.035 0.988
0.665 22.471 0.285 0.011 0.998
0.726 305.410 0.485 0.001 1.000
0.786 0.774 0.000 1.000

*Relative to the effective permeability to oil at initial water saturation.


WATER - OIL RELATIVE PERMEABILITY
Steady State Method Extracted State Sample
Net Confining Stress: Temperature:
Sample Number:
Sample Depth, meters:
Permeability to Air, md:
Porosity, fraction:
Initial Water Saturation, fraction:
Effective Oil Permeability at Swi, md:
Petrophysical Parameters

 a=1
 m=2
 n=2

You might also like