A Excavate pit for pilecap not exceeding 1.50 m deep commencing from formation
level and get out, part return, fill in and ram and deposit and spread in making up
levels where directed and remainder load and cart away m3 52
E Pilecap m3 33
F Column Stump m3 9
G Ground Beam m3 30
Pilecap
Column Stump
L 10mm Diameter Bar as links Kg 500
Ground beam
Pilecap
P 16mm Diameter Bar Kg 2,150
Column Stump
16mm Diameter Bar Kg 13
BQ6/EWT/1/R2
INFRASTRUCTURE WORKS (ALL PROVISIONAL)
C 50mm thick blinding laid on earth to receive ground slab and apron. m3 1
E
Edge of concrete slab exceeding 100mm and not exceeding 200mm high m 15
-------------------------------------
F Layer of BRC steel fabric reinforcement Ref. No. A7 weighing not less than 3.02
kg/m2 well lapped and joint and embedded in concrete bed (measured nett - no
allowance made for laps) m2 21
G Allow for preparing and applying of four (4) stages pre-construction anti-termite
treatment to be carried out by an approved soil treatment specialist including
preparation of surface to receive treatment, working progressively, all in accordance
with an approved by Engineer. Item -
FRAME
H Column m3 140
L Roof beam m3 22
TO COLLECTION :
BQ6/EWT/2/R2
INFRASTRUCTURE WORKS (ALL PROVISIONAL)
FRAME (Cont'd)
Suspended beam
B 10mm Diameter stirrups Kg 5,300
Upper Beam
C 10mm Diameter stirrups Kg 5,000
Roof beam
D 10mm Diameter stirrups Kg 1,325
Column
E 16mm Diameter Bar Kg 70
F 20mm Diameter Bar Kg 110
G 25mm Diameter Bar Kg 920
H 32mm Diameter Bar Kg 1,110
Suspended beam
Roof beam
R 12mm Diameter Bar Kg 1,800
S 16mm Diameter Bar Kg 2,000
T 20mm Diameter Bar Kg 6,300
TO COLLECTION :
BQ6/EWT/3/R2
INFRASTRUCTURE WORKS (ALL PROVISIONAL)
E Supply and apply 'Aqualseal 1000' or other equal and approved cementitious
waterproofing system all in accordance to manufacturer's instruction and including
ponding test (wet area) m2 650
STAIRCASE
STAIRCASE STRUCTURE
VIBRATED REINFORCED CONCRETE GRADE 35A as described :-
A In staircase m3 4
B In landing slab m3 1.2
C In landing beam m3 0.5
TO COLLECTION :
BQ6/EWT/4/R2
INFRASTRUCTURE WORKS (ALL PROVISIONAL)
20mm Thick paving to staircase and the like trowelled finished as described:-
R Extra For 150mm long x 75mm wide x 21mm thick non-slip ceramic nosing tiles m 22
Hot-dipped stainless steel handrails and balustrades part raking and part horizontal
comprising of 50mm diameter tubular section top rails, 50mm diameter rod as top,
intermediate and bottom horizontal rails, 25mm diameter tubular section as
balusters, each welded to and including fishtailed and casted into concrete; all cut,
welded and framed together with all welds filed smooth and fixed in position
including all shop and site connections, drilling, grouting, ramps, knees, stop ends,
touching up and including all necessary works all as shown in detail drawings :-
TO COLLECTION : -
BQ6/EWT/5/R2
INFRASTRUCTURE WORKS (ALL PROVISIONAL)
F In roof slab m3 50
USE AND WASTE OF SAWN FORMWORK as described to:-
G Soffit of roof slab m2 500
H Edge of concrete slab exceeding 100mm and not exceeding 200mm high m 100
HIGH TENSILE ROD REINFORCEMENT as described :-
Roof Slab
J 10mm Diameter Bar Kg 6,600
-------------------------------------
K Supply and apply 'Aqualseal 1000' or other equal and approved cementitious
waterproofing system all in accordance to manufacturer's instruction including
returned 300mm high to wall and including ponding test. m2 500
BQ6/EWT/6/R2
INFRASTRUCTURE WORKS (ALL PROVISIONAL)
CEILING FINISHES
3MM THICK APPROVED DOUBLE LAYER SKIM COATING INCLUDING
SURFACE PREPARATION AS DESCRIBED PLASTERING FINISHED WITH A
STEEL TROWEL INCLUDING PAINTING as specified to :-
K To soffit of water tank slab m2 500
PREPARE AND APPLY ONE ALKALI-RESISTANT SEALER AND TWO COATS
"JOTUN" OR OTHER EQUIVALENTS AND APPROVED WEATHERSHIELD PAINT
as described to :
L To surface of approved skim coat water tank slab m2 500
ROOF FINISHES
B 19mm Thick cement and sand (1:3) smooth finish plaster with and approved to
external sides of water tank wall m2 400
TO COLLECTION : -
BQ6/EWT/7/R2
INFRASTRUCTURE WORKS (ALL PROVISIONAL)
N 600mm diameter Reinforced Concrete Pipe Class 'Z' and including all necessary
excavation, formwork, backfilling compacted and disposal of surplus excavated
materials from site as directed by Engineer all as shown. m 4
P 200mm diameter Ductile Iron inlet pipe laid to gradient including all necessary
excavation, backfilling, compacted, reinforcement, formwork, all connection to
Suction Tank structure, disposal off material from site, testing and commissioning
and commissioning as Engineer approval and as shown.
SUNDRIES (Cont'd)
A 200mm diameter Ductile Iron scour pipe laid to gradient including all necessary m 3
excavation, backfilling, compacted, reinforcement, formwork, all connection to
Suction Tank structure, disposal off material from site, testing and commissioning
and commissioning as Engineer approval and as shown.
B 200mm diameter Ductile Iron over flow pipe laid to gradient including all necessary m 4
excavation, backfilling, compacted, reinforcement, formwork, all connection to
Suction Tank structure, disposal off material from site, testing and commissioning
and commissioning as Engineer approval and as shown.
C 200mm diameter Ductile Iron rose strainer including all necessary works as
Architect approval and as shown in the Engineer's drawing. No 1
D Approved 900mm x 900mm aluminium manhole cover and frame including setting in No. 2
cement mortar (1:3) and sealing cover and apply with black synthetic resin based
paint on exposed surfaces all as shown.
Valve
E Approved 200mm Diameter Ductile Iron Sluice valve all as per Engineer's detail
specification No. 1
BQ6/EWT/8/R2
INFRASTRUCTURE WORKS (ALL PROVISIONAL)
Galvanised mild steel grating constructed of 50mm x 50mm x 6mm thick flat bar all
round as mild steel angle and 50mm x 10mm thick flat bar as removal cover frame
and all welded together and including all necessary hinge, washer, galvanised pin
etc and place in position all as shown on the Engineer's drawing
J Overall size 1500mm x 1500mm No. 9
SUNDRIES (Cont'd)
A 225mm half round drain (MD 375) 1:300 complete with heavy duty mild steel grating m 7
and including all necessary excavation, formwork, backfilling compacted and
disposal of surplus excavated materials from site as directed by Engineer all as
shown.
Railing
B Supply and install 1000mm overall height handrail made of hot-dipped galvanised m 53
mild steel and incuding all neccessary painting works as per Engineer's details.
Chain Link Fence (Anti-Climb)
UPVC COATED CHAIN LINK FENCING (10 SWG WIRE) COMPRISING 50MM X
50MM X 6MM THICK MILD 'L' STEEL ANGLE IRON POST WITH STAY SUPPORT
AT 3000MM CENTRES AND INCLUDING EXCAVATION, FORMWORKS,
REINFORCEMENT, CONCRETE FOUNDATION, PAINTING, ETC. ALL AS PER
ENGINEER'S DRAWING.
C PVC coated chainlink fencing(10 SWG wire) for 3450mm high m 170
_______________________
D Mild steel sliding gate, overall size 900mm x 1500mm high, comprising of mild steel No. 1
hollow section frame, door hinges, fittings, locks, accessories, ironmongery, logo
SYABAS and including excavation, formworks, reinforcement, concrete foundation
and painting all in accordance with the Engineer's detail drawings
2 LAYERS OF WIRE ROPE, 2 LAYERS OF BULK WIRE AND INCLUDING
EXCAVATION, FORMWORKS, REINFORCEMENT, CONCRETE FOUNDATION,
PAINTING, ETC. ALL AS PER ENGINEER'S DRAWING.
E 600mm diamter rolled razor wire m 170
Handling over to SYABAS
F Liason with relevant authorities involves water reticulation work for testing,
inspection and handling over to SYABAS Item - -
TO COLLECTION : -
BQ6/EWT/9/R2
INFRASTRUCTURE WORKS (ALL PROVISIONAL)
COLLECTION
BQ6/EWT/1/R2
BQ6/EWT/2/R2
BQ6/EWT/3/R2
BQ6/EWT/4/R2
BQ6/EWT/5/R2
BQ6/EWT/6/R2
BQ6/EWT/7/R2
BQ6/EWT/8/R2
BQ6/EWT/9/R2
BQ6/EWT/10/R2