INFRASTRUCTURE WORKS (ALL PROVISIONAL)

ITEM DESCRIPTION UNIT RATE QTY. AMOUNT


(RM)
ELEVATED WATER TANK
WORK BELOW LOWEST FLOOR FINISH

A Excavate pit for pilecap not exceeding 1.50 m deep commencing from formation
level and get out, part return, fill in and ram and deposit and spread in making up
levels where directed and remainder load and cart away m3 52

B Excavate trench for ground beam, ditto m3 30

LEAN MIX CONCRETE GRADE 15 (1:3:6 - 38 MM AGGREGATE) as described :-

C 50mm thick blinding laid on earth to receive pilecap m3 3

D Ditto, ground beam m3 4

VIBRATED REINFORCED CONCRETE GRADE 30 as described :-

E Pilecap m3 33
F Column Stump m3 9
G Ground Beam m3 30

USE AND WASTE OF SAWN FORMWORK as described to:-


H Sides of pilecap m2 107
J Sides of column stump m2 34
K Sides of ground beam m2 260
HIGH TENSILE ROD REINFORCEMENT as described :-

Pilecap

12mm Diameter Bar Kg 531

Column Stump
L 10mm Diameter Bar as links Kg 500
Ground beam

M 10mm Diameter Bar, ditto Kg 1,320


HIGH TENSILE ROD REINFORCEMENT as described :-

Pilecap
P 16mm Diameter Bar Kg 2,150
Column Stump
16mm Diameter Bar Kg 13

Q 20mm Diameter Bar Kg 21


25mm Diameter Bar Kg 183
32mm Diameter Bar Kg 222
Ground beam
R 12mm Diameter Bar Kg 3,250
S 16mm Diameter Bar Kg 33
TO COLLECTION :

BQ6/EWT/1/R2
INFRASTRUCTURE WORKS (ALL PROVISIONAL)

ITEM DESCRIPTION UNIT RATE QTY. AMOUNT


(RM)

ELEVATED WATER TANK (Cont'd)


GROUND FLOOR SLAB
A Excavate to reduce level average 350mm deep get out, load and cart away from

site including levelling, grading and ramming bottom at excavation. m3 2


B 150mm thick bed of hardcore as described spread, levelled and blinded with sand to
receive concrete bed and apron. m2 2
LEAN MIX CONCRETE GRADE 15 (1:3:6 - 38 MM
AGGREGATE) as described :-

C 50mm thick blinding laid on earth to receive ground slab and apron. m3 1

VIBRATED REINFORCED CONCRETE GRADE 30 as described :-

D To ground floor slab and apron. m3 2


USE AND WASTE OF SAWN FORMWORK as described to:-

E
Edge of concrete slab exceeding 100mm and not exceeding 200mm high m 15
-------------------------------------
F Layer of BRC steel fabric reinforcement Ref. No. A7 weighing not less than 3.02
kg/m2 well lapped and joint and embedded in concrete bed (measured nett - no
allowance made for laps) m2 21

G Allow for preparing and applying of four (4) stages pre-construction anti-termite
treatment to be carried out by an approved soil treatment specialist including
preparation of surface to receive treatment, working progressively, all in accordance
with an approved by Engineer. Item -
FRAME

VIBRATED REINFORCED CONCRETE GRADE 30 as described :-

H Column m3 140

J Suspended beam m3 109


K Upper beam m3

L Roof beam m3 22

USE AND WASTE OF SAWN FORMWORK as described to:-

M Sides of column m2 1,120

N Sides and soffit of suspended beam m2 1,205

P Sides and soffit of upper beam m2 660

Q Sides and soffit of roof beam m2 300

TO COLLECTION :

BQ6/EWT/2/R2
INFRASTRUCTURE WORKS (ALL PROVISIONAL)

ITEM DESCRIPTION UNIT RATE QTY. AMOUNT


(RM)

ELEVATED WATER TANK (Cont'd)

FRAME (Cont'd)

HIGH TENSILE ROD REINFORCEMENT as described :-


Column
A 10mm Diameter links Kg 2,500

Suspended beam
B 10mm Diameter stirrups Kg 5,300
Upper Beam
C 10mm Diameter stirrups Kg 5,000
Roof beam
D 10mm Diameter stirrups Kg 1,325

HIGH TENSILE ROD REINFORCEMENT as described :-

Column
E 16mm Diameter Bar Kg 70
F 20mm Diameter Bar Kg 110
G 25mm Diameter Bar Kg 920
H 32mm Diameter Bar Kg 1,110
Suspended beam

J 12mm Diameter Bar Kg 13,000


K 16mm Diameter Bar Kg 150
Upper beam
L 12mm Diameter Bar 3,300
M 16mm Diameter Bar Kg 21,000
N 20mm Diameter Bar Kg 800
P 25mm Diameter Bar 37,500
Q 32mm Diameter Bar 17,300

Roof beam
R 12mm Diameter Bar Kg 1,800
S 16mm Diameter Bar Kg 2,000
T 20mm Diameter Bar Kg 6,300

TO COLLECTION :

BQ6/EWT/3/R2
INFRASTRUCTURE WORKS (ALL PROVISIONAL)

ITEM DESCRIPTION UNIT RATE QTY. AMOUNT


(RM)

ELEVATED WATER TANK (Cont'd)

UPPER FLOOR SLAB


VIBRATED REINFORCED CONCRETE GRADE 35A as described :-

A In upper floor m3 150


USE AND WASTE OF SAWN FORMWORK as described to:-
B Soffit of suspended slab m2 650
C
Edge of concrete slab exceeding 200mm and not exceeding 300mm high m 110
HIGH TENSILE ROD REINFORCEMENT as described :-
D 16mm Diameter Bar Kg 27,500

E Supply and apply 'Aqualseal 1000' or other equal and approved cementitious
waterproofing system all in accordance to manufacturer's instruction and including
ponding test (wet area) m2 650
STAIRCASE
STAIRCASE STRUCTURE
VIBRATED REINFORCED CONCRETE GRADE 35A as described :-

A In staircase m3 4
B In landing slab m3 1.2
C In landing beam m3 0.5

USE AND WASTE OF SAWN FORMWORK as described to:-


D To sloping soffit of staircase m2 7
E To open string of staircase 300mm (extreme) wide including cutting to profile steps
m 15
F To soffit of landing slab m2 6
G To sides and soffit of landing beam m2 5

H To undercut riser not exceeding 200mm high m 22

HIGH TENSILE ROD REINFORCEMENT as described :-


In Landing Beam
J 12 mm Diameter Bar Kg 60
K 16 mm Diameter Bar Kg 70

In Staircase & Landing Slab

L 12mm Diameter Bar 36


M 16mm Diameter Bar Kg 31

TO COLLECTION :

BQ6/EWT/4/R2
INFRASTRUCTURE WORKS (ALL PROVISIONAL)

ITEM DESCRIPTION UNIT RATE QTY. AMOUNT


(RM)

ELEVATED WATER TANK (Cont'd)


STAIRCASE FINISHES

CEMENT AND SAND (1:3) as described paving :-

20mm Thick paving to staircase and the like trowelled finished as described:-

N 20mm Thick to landing slab m2 6


P Ditto to riser, 173mm high m 4
Q Ditto to tread, 250mm wide m 5

R Extra For 150mm long x 75mm wide x 21mm thick non-slip ceramic nosing tiles m 22

3MM THICK APPROVED DOUBLE LAYER SKIM COATING INCLUDING


SURFACE PREPARATION AS DESCRIBED PLASTERING FINISHED WITH A
STEEL TROWEL INCLUDING PAINTING as specified to :-

S Open string of staircase 300mm (extreme) wide m 13


T Slopping soffit of staircase m2 7
V Soffit of Landing Slab m2 6

W Sides and soffit of landing beam m2 5

STAIRCASE FINISHES (Cont'd)


PREPARE AND APPLY ONE ALKALI-RESISTANT SEALER AND TWO COATS
"JOTUN" OR OTHER EQUIVALENTS AND APPROVED WEATHERSHIELD PAINT
as described to :

A To open string of staircase 300mm (extreme) wide m 13


B To slopping soffit of staircase m2 7
C To soffit of Landing Slab m2 6
D To Sides and soffit of landing beam m2 5
Handrail and Balustrades

Hot-dipped stainless steel handrails and balustrades part raking and part horizontal
comprising of 50mm diameter tubular section top rails, 50mm diameter rod as top,
intermediate and bottom horizontal rails, 25mm diameter tubular section as
balusters, each welded to and including fishtailed and casted into concrete; all cut,
welded and framed together with all welds filed smooth and fixed in position
including all shop and site connections, drilling, grouting, ramps, knees, stop ends,
touching up and including all necessary works all as shown in detail drawings :-

E 1000mm high handrails and balustrades m 250

TO COLLECTION : -

BQ6/EWT/5/R2
INFRASTRUCTURE WORKS (ALL PROVISIONAL)

ITEM DESCRIPTION UNIT RATE QTY. AMOUNT


(RM)

ELEVATED WATER TANK (Cont'd)


ROOF
ROOF STRUCTURE
VIBRATED REINFORCED CONCRETE GRADE 35A as described :-

F In roof slab m3 50
USE AND WASTE OF SAWN FORMWORK as described to:-
G Soffit of roof slab m2 500

H Edge of concrete slab exceeding 100mm and not exceeding 200mm high m 100
HIGH TENSILE ROD REINFORCEMENT as described :-
Roof Slab
J 10mm Diameter Bar Kg 6,600
-------------------------------------
K Supply and apply 'Aqualseal 1000' or other equal and approved cementitious
waterproofing system all in accordance to manufacturer's instruction including
returned 300mm high to wall and including ponding test. m2 500

REINFORCED CONCRETE WALL

VIBRATED REINFORCED CONCRETE GRADE 35A as described :-

A To water tank wall m3 115


USE AND WASTE OF SAWN FORMWORK as described to:-
B Sides of water tank wall m2 302
HIGH TENSILE ROD REINFORCEMENT as described :-
C 10mm Diameter Bar Kg 250
D 12mm Diameter Bar Kg 170
E 16mm Diameter Bar Kg 16,500
CONSTRUCTION JOINT IN CONCRETE WALL / SLAB ABUTMENT INCLUDING
ALL NECESSARY STAGING, ROUGHING, FORMWORK, DUMBELL PVC WATER
STOP AND SEALING ONE FACE WITH OVERALL SIZE 12MM X 30MM DEEP
APPROVED SEALING COMPOUND:-
F 225mm Wide joint and waterstop m 100
SUPPLY AND LAY 3 COATS OF NON-TOXIC ACRYLIC POLIMER MODIFIED
CEMENTITIOUS WATERPROOF COATING AND ALL STRICTLY ACCORDANCE
TO MANUFACTURER'S SPECIFICATION AND INSTRUCTION:-
G To internal wall surface of water tank m2 400
H To base of water tank m2 500
TO COLLECTION : -

BQ6/EWT/6/R2
INFRASTRUCTURE WORKS (ALL PROVISIONAL)

ITEM DESCRIPTION UNIT RATE QTY. AMOUNT


(RM)

ELEVATED WATER TANK (Cont'd)


FLOOR FINISHES

CEMENT AND SAND as described :-

J 20mm Thick Paving to floor trowelled smooth m2 650

CEILING FINISHES
3MM THICK APPROVED DOUBLE LAYER SKIM COATING INCLUDING
SURFACE PREPARATION AS DESCRIBED PLASTERING FINISHED WITH A
STEEL TROWEL INCLUDING PAINTING as specified to :-
K To soffit of water tank slab m2 500
PREPARE AND APPLY ONE ALKALI-RESISTANT SEALER AND TWO COATS
"JOTUN" OR OTHER EQUIVALENTS AND APPROVED WEATHERSHIELD PAINT
as described to :
L To surface of approved skim coat water tank slab m2 500

ROOF FINISHES

3MM THICK APPROVED DOUBLE LAYER SKIM COATING INCLUDING


SURFACE PREPARATION AS DESCRIBED PLASTERING FINISHED WITH A
STEEL TROWEL INCLUDING PAINTING as specified to :-
M To roof slab m2 500
ROOF FINISHES (Cont'd)

PREPARE AND APPLY ONE ALKALI-RESISTANT SEALER AND TWO COATS


"JOTUN" OR OTHER EQUIVALENTS AND APPROVED WEATHERSHIELD PAINT
as described to :
A To surface of approved skim coat roof slab m2 500
WALL FINISHES

B 19mm Thick cement and sand (1:3) smooth finish plaster with and approved to
external sides of water tank wall m2 400

PREPARE AND APPLY ONE ALKALI-RESISTANT SEALER AND TWO COATS


"JOTUN" OR OTHER EQUIVALENTS AND APPROVED WEATHERSHIELD PAINT
as described to :
C To sides of column m2 1,120
D To sides and soffit of suspended beam m2 1,205
E To sides and soffit of upper beam m2 660
PREPARE AND APPLY ONE ALKALI-RESISTANT SEALER AND TWO COATS
"JOTUN" OR OTHER EQUIVALENTS AND APPROVED WEATHERSHIELD PAINT
as described to :
F To surface of plastered water tank wall m2 400
G To surface of approved skim coat column and the like m2 1,120

H Ditto, suspended beam m2 1,205


J Ditto, upper beam m2 660

TO COLLECTION : -

BQ6/EWT/7/R2
INFRASTRUCTURE WORKS (ALL PROVISIONAL)

ITEM DESCRIPTION UNIT RATE QTY. AMOUNT


(RM)
ELEVATED WATER TANK (Cont'd)
STAINLESS STEEL LADDER
K Supply and install 600mm wide stainless steel ladder comprising of 80 x 40 x 2mm No. 1
(3.71kg/m) stainless steel rectangular hollow section, 100 x 40 x 2mm (4.38kg/m)
stainless steel rectangular hollow section, 160 x 80 x 6mm stainless steel plate
welded with 6mm fillet weld all round as per Engineer's details.
SUNDRIES

L 225mm Diameter half round precast concrete Grade 20 as described perimeter


drain channel in convenient length and laid to falls on and including 450mm x
100mm thick as described bed and including all end, angles, junction and all
necessary excavation, concrete, brickwork, formwork, reinforcement, and
connection to newly built block drain.
M Supply and install 150mm diameter pvc pipe sleeve with aluminium mosquito proof
netting at four sides of water tank wall. No. 12

N 600mm diameter Reinforced Concrete Pipe Class 'Z' and including all necessary
excavation, formwork, backfilling compacted and disposal of surplus excavated
materials from site as directed by Engineer all as shown. m 4
P 200mm diameter Ductile Iron inlet pipe laid to gradient including all necessary
excavation, backfilling, compacted, reinforcement, formwork, all connection to
Suction Tank structure, disposal off material from site, testing and commissioning
and commissioning as Engineer approval and as shown.

SUNDRIES (Cont'd)
A 200mm diameter Ductile Iron scour pipe laid to gradient including all necessary m 3
excavation, backfilling, compacted, reinforcement, formwork, all connection to
Suction Tank structure, disposal off material from site, testing and commissioning
and commissioning as Engineer approval and as shown.
B 200mm diameter Ductile Iron over flow pipe laid to gradient including all necessary m 4
excavation, backfilling, compacted, reinforcement, formwork, all connection to
Suction Tank structure, disposal off material from site, testing and commissioning
and commissioning as Engineer approval and as shown.

C 200mm diameter Ductile Iron rose strainer including all necessary works as
Architect approval and as shown in the Engineer's drawing. No 1

D Approved 900mm x 900mm aluminium manhole cover and frame including setting in No. 2
cement mortar (1:3) and sealing cover and apply with black synthetic resin based
paint on exposed surfaces all as shown.
Valve
E Approved 200mm Diameter Ductile Iron Sluice valve all as per Engineer's detail
specification No. 1

F Ditto, 150mm Diameter Sluice valve, ditto. No. 1


TO COLLECTION : -

BQ6/EWT/8/R2
INFRASTRUCTURE WORKS (ALL PROVISIONAL)

ITEM DESCRIPTION UNIT RATE QTY. AMOUNT


(RM)

ELEVATED WATER TANK (Cont'd)


Valve Chamber
G No. 2
1500mm x 1500mm (internal dimension) reinforced concrete Sluice valve chamber
constructed of 225mm thick (wall and slab thickness) complete with 20mm thick
plastering,reinforced with 12mm diameter high tensile rod reinforcement at 200mm
centres (bothway) with heavy duty mild steel grating as shown in the Engineer's
drawing
Brickwork sumps constructed on 260mm thick vibrated reinforced concrete Grade
20 (20mm aggregate) bed as described reinforced with a layer of steel mesh fabric
reinforcement Ref. A6 on 50mm thick concrete Grade 10 (20mm aggregate)
blinding, 225mm thick brickwall all round, 10mm diameter mild steel fish tail and
20mm thick cement and sand (1:3) plaster internally, reinforced concrete lintol all
round and including all necessary excavation, formwork, backfilling etc.all as shown
in Engineer's Drawing.
H 1500mm x 1500mm (internal size), average 2860mm internal depth. No. 9

Galvanised mild steel grating constructed of 50mm x 50mm x 6mm thick flat bar all
round as mild steel angle and 50mm x 10mm thick flat bar as removal cover frame
and all welded together and including all necessary hinge, washer, galvanised pin
etc and place in position all as shown on the Engineer's drawing
J Overall size 1500mm x 1500mm No. 9
SUNDRIES (Cont'd)
A 225mm half round drain (MD 375) 1:300 complete with heavy duty mild steel grating m 7
and including all necessary excavation, formwork, backfilling compacted and
disposal of surplus excavated materials from site as directed by Engineer all as
shown.
Railing
B Supply and install 1000mm overall height handrail made of hot-dipped galvanised m 53
mild steel and incuding all neccessary painting works as per Engineer's details.
Chain Link Fence (Anti-Climb)
UPVC COATED CHAIN LINK FENCING (10 SWG WIRE) COMPRISING 50MM X
50MM X 6MM THICK MILD 'L' STEEL ANGLE IRON POST WITH STAY SUPPORT
AT 3000MM CENTRES AND INCLUDING EXCAVATION, FORMWORKS,
REINFORCEMENT, CONCRETE FOUNDATION, PAINTING, ETC. ALL AS PER
ENGINEER'S DRAWING.
C PVC coated chainlink fencing(10 SWG wire) for 3450mm high m 170
_______________________
D Mild steel sliding gate, overall size 900mm x 1500mm high, comprising of mild steel No. 1
hollow section frame, door hinges, fittings, locks, accessories, ironmongery, logo
SYABAS and including excavation, formworks, reinforcement, concrete foundation
and painting all in accordance with the Engineer's detail drawings
2 LAYERS OF WIRE ROPE, 2 LAYERS OF BULK WIRE AND INCLUDING
EXCAVATION, FORMWORKS, REINFORCEMENT, CONCRETE FOUNDATION,
PAINTING, ETC. ALL AS PER ENGINEER'S DRAWING.
E 600mm diamter rolled razor wire m 170
Handling over to SYABAS
F Liason with relevant authorities involves water reticulation work for testing,
inspection and handling over to SYABAS Item - -
TO COLLECTION : -

BQ6/EWT/9/R2
INFRASTRUCTURE WORKS (ALL PROVISIONAL)

ITEM DESCRIPTION UNIT RATE QTY. AMOUNT


(RM)

ELEVATED WATER TANK (Cont'd)

COLLECTION

BQ6/EWT/1/R2

BQ6/EWT/2/R2

BQ6/EWT/3/R2

BQ6/EWT/4/R2

BQ6/EWT/5/R2

BQ6/EWT/6/R2

BQ6/EWT/7/R2

BQ6/EWT/8/R2

BQ6/EWT/9/R2

TOTAL AMOUNT CARRIED TO SUMMARY : -

BQ6/EWT/10/R2