Professional Documents
Culture Documents
Spec For SDRP0612K-J-08 (X3)
Spec For SDRP0612K-J-08 (X3)
FOR
CELLULAR PORTABLE
PHONE RECEIVER
CUSTOMER :
CUSTOMER P/N :
Email: aaca@aacelectr.com
REV: X3
Product Specification P/N SDRP0612K-J-08
Table of contents
1. Scope
2. Environmental Requirement
3. Electrical Requirements
4. Acoustical Requirements
5. Test Climatic condition
6. Test Method
7. General Requirement
8. Reliability Tests
9. Mechanical Layout and Dimensions
10. Weight
11. Package
1. Scope
This document contains required environmental, electrical, acoustic, mechanical, package and
reliability test requirements.
2. Environmental Requirement
The transducer including all components and solder joints must be free from lead (Pb) and other
banned or restricted substances according to customer's requirements.
3. Electrical Requirements
3.2 Rated Noise Power (in free air) 20 mW See section 8.4
3.3 Short Term Maximum Power (in free air) 40 mW See section 8.5
4. Acoustical Requirements
4.1 Sound Pressure Level 25.5±3 dB Pa/V 1kHz with Type3.2 HL ear
For reference 117.5dB SPL ref.20uPa@20mW 1kHz with Type3.2 HL ear
Frequency Response,DRP
50
40
30
dB Pa/V,566mVrms/32Ω
20
10
0
100 1000 10000
-10
-20
-30
-40
Frequency (Hz)
Frequency Frequency
Upper (dB) Lower (dB)
(Hz) (Hz)
300 -2 300 -16
400 4 400 -10
500 4 500 -6
900 3 900 -2.5
1000 0 1000 0
1120 4.5 1120 -2.5
1700 15 1700 4
2500 5 2500 -5
3500 3 3500 -6
5000 -3 5000 -19
6000 -10 6000 -25
Earspeaker Distortion
100
90
80
THD (%),566mVrms/32Ω
70
60
50
40
30
20
10
0
100 1000 10000
Frequency (Hz)
Frequency
Upper limit (%)
(Hz)
300 55
400 42
500 32
800 12
1000 5
4000 1
6. Test Method
6.1 SPL and Frequency Response Curve
6.1.1 Based on Type 3.2HL ear test
The receiver shall be mounted in a fixture shown in Figure4,
and the recommended acoustic measuring devices are shown in Figure5.
The artificial ear shall be a type 3.2 high leak ear (such as the B&K4195).
The DRP-to-ERP weighting function shall be not be applied. The swept sine-wave frequency range is
100Hz-10kHz,and tested with an input level of 566mVrms.
6.2 THD
6.2.1 Based on Type 3.2HL ear test
The receiver shall be mounted in a fixture shown in Figure4
and the recommended acoustic measuring devices are shown in Figure5.
The artificial ear shall be a type 3.2 high leak ear (such as the B&K4195).
The DRP-to-ERP weighting function shall not be applied. The swept sine-wave frequency range is
300Hz-4kHz,and tested with an input level of 566mVrms.
source
Artificial Ear
(B&K 4195 High-leak pinna simulator)
IEC711 coupler
(with 12" microphone)
Peramplifier (TYPE2669)
Acoustic Analyzer
(B&K 2012)
7. General Requirements
7.1 Operating Temperature Range : -20°C to +70°C
7.2 Storage Temperature Range : -40°C to +85°C
8. Reliability Tests
Immediately after reliability test, the samples shall be stored under climatic conditions such as
normally exist in ordinary rooms or laboratories. Unless otherwise noted, the recovery period
shall be 4 hours at least before performance testing.
After reliability test, all samples must be meet the requirements specified in section 3 & 4.
8 SPRING 2 STEEL
7 MAGNET CAP 1 STEEL
6 MAGNET 1 NdFeB
5 COVER 1 COPPER
4 VOICE COIL 1 COPPER
3 UPPER PLATE 1 STEEL
2 DIAPHRAGM 1 PAR
1 FRAME 1 PLASTIC
PART NO. PART NAME Q'TY MATERIAL TREATMENT REMARK
PS
06
Pasteboard Adhesive tape
carrier
Cover ( empty traytape
)
XX
Surface resistance
AACD
reel ≤1X10^8 Ω
Plastic tray
75 pcs per tray
75X10=750 product
pcs
Pasteboard
cover tape
plastic bag
Carton
Carton
750X2=1500
1 reel per cartonpcs per carton
1000 pcs per reelpcs
1500X2=3000
1000 pcs per carton
Carton
Box
2Total 5 carton
cartons per box
1000X5=5000 pcs Pcs per box
Total:1500x2=3000
Box size: (LXWXH)
Box
cm:39.8x29.8x45.5
5 cartons per box
Total: 1000X5=5000 Pcs per box
Box size: (LXWXH)
CM:36x22.5x37
Figure11 Package
AAC Confidential Information