Document Drawing/
S.No. Date Description Document No. Revision Issued for
K.R.Venkatachalam
Manager-C&I
CNT No.:SVP-006-18/19
COVER SHEET DOC No.:STD/CI-FIREA-0029
list of powerful features. The panel has maximum Switched Mode Power Supply.
?
Modular Construction, Serviceability.
?
capability for four loop cards, which are plugged into the
Networkable.
?
main circuit board. Higher loop requirements can be Auto Resettable Fuse.
?
catered to using the networking feature of the fire alarm Surge Protection.
?
control panel. There is an option for remote and local Battery polarity protection.
?
32 bit processor
?
programming of the control panel using configuration
Unique protocol feature for fast alarm response.
?
software / Avani soft upload/download utility. Inbuilt conventional circuit.
?
Touch Keypad for user friendly operation.
?
All the PCB's are mounted over a stud and the
Auto learning facility.
?
power supply boards is secured by a separate metal box. Multi protocol.
?
Peer to Peer Networking.
?
Redundancy : If the main CPU fails,
?
it will raise an alarm like conventional panel.
Features:
Device / Detector wise configuration facility.
?
2000 Event Storage with Real Time Clock.
?
Upto 192 grouping facility.
?
Pre Alarm Action.
?
All field wiring are power limited and supervised.
?
Programmable detector sensitivity.
?
Device type verification.
?
Earth fault annunciation facility at 0 ohms.
?
Double Address Sensing.
?
Loop wise device test .
?
40 X 4 Characters LCD display
?
5 IDC Loops (4 Addressable and 1 Conventional loop).
?
Maximum 4 numbers of loop card with Class A,
?
Style 5,6 or 7 and Class B Style 4 wiring
Maximum 254 devices (any combination) per loop.
?
Day / Night Mode facility.
?
USB 2.0 Interface for PC connectivity.
?
RS 485 Communication facility for Network / Repeater
?
/ MODBUS / BACnet.
Programmable Auto Silence Facility.
?
Programmable AC Loss Delay.
?
Programmable Silence Inhibit.
?
Two programmable Inputs for Evacuate,
?
Silence & Conventional Zone
Battery low audio, visual warning.
?
Three programmable Form C relay for Fire, Fault and Supervisory.
?
Two no’s of Supervise Notification Appliance Circuits.
?
Electrical Specification:
Primary Power Programmable Relays
120 / 220VAC + 10% -15%, 60 / 50 Hz, 450W. Type : Form C
No of Relays :3
Standby Power Relay Contact Rating : 2A @ 30 VDC,
24V DC (2 No’s of 12V, 40 Ah (Max), Built in for 0.5A @ 125VAC.
14Ah) Sealed Lead acid battery. Power factor : 1.0
Mounting Detail:
EOL
PN: RE4K7
OUT
Relay 3 NO
Relay 2 NO
Relay 1 NO
NC
NC
NC
C0
C0
C0
IN
N
P
B
B
A
E
+
+
_
120 - 220V
OUT
OUT
OUT
OUT
Program.
Program.
Program.
AC Input
(300mA)
IN
IN
IN
IN
DC 24V
RS 485
RS 485
Output
Input 2
Input 1
Output
NAC - 1 NAC - 2
Input
(IDC)
1.8 Amps Loop Card 1 Loop Card 2 Loop Card 3 Loop Card 4
Note:
¤All the field wiring circuits are supervised
¤All the field wiring circuits are Power limited except 120-220 VAC and Battery.
Input 1
Initiating Device Circuit
Class B Style B/C
End of Line - 4K7 1/2W
PN: RE4K7
FACP - 32 FACP - 2
*LAN / ROUTER
FACP - 3
FARP-8
FACP-8
Compatible Devices:
MODELS DESCRIPTION
RE-317D-SHL Photoelectric & Heat detector
RE-317D-SL Photoelectric smoke detector
RE-317D-HL Heat detector
RE-717MC Control Module
RE-717MM Monitor Module
RE-717MR Relay Module
RE-717MI Isolator Module
RE-717M Manual Call Point
RE-AMB Modbus Converter
RE-517ME Ethernet Module
RE-717PT Printer Module
RE-517BN BACnet Converter
Avani - RP Fire Alarm Repeater Panel
RE-314BI Isolator Base
RE-515MP-A4 Mimic Display System - 32 LED Panel (Max)
RE-515MP-A3 Mimic Display System - 64 LED Panel (Max)
RE-515MP-A2 Mimic Display System - 128 LED Panel (Max)
RE-515MP-AX Mimic Display System - 512 LED Panel (Max)
RE-4K7 End Of Line Resistor
Approval:
Ordering Information:
MODEL Loop
Avani - W / R / B 1,2,3 & 4 Loop
Note:
W - White Color
R - Red Color
B - Black Color
*In the interest of improving quality and design, Ravel reserve the right to change the specification without prior notice. AVANI / REV 1.10 / 2016-2017
RE-2APS / RE-5 APS
Power Supply Panel
Product Overview
The RE-2APS, RE-5APS is compact and cost effective 2
Amps / 5 Amps power supply with build-in charger. It may
be connect to the any 24 Volt Fire alarm control panel or
may be stand-alone for the primary applications like
Notification appliance circuit expansion or auxiliary
power to support 24 Volt system accessories. It provides
regulated and filtered 24 VDC power to NAC’s and it also
contains a battery charger capable of charging up to 14
Ah batteries.
Features
Operates on 220V, A.C supply.
¬
Battery backup with built in charging.
¬
Low battery visual warning with audible tone.
¬
DC Output indication.
¬
Electrical Specification:
Mains
220 VAC, 50 Hz +10%, -15%.
Wire size: 1.5 Sq. mm with 600V insulation
Battery (Lead Acid only)
Charging Voltage: 27.9 VDC.
Charging Capacity: 2 X 12V, 7 Ah Battery Max.
System Quiescent Current: 35mA
Output Voltage
For RE-2APS -24VDC @ 2A Max.
For RE-5APS -24VDC @ 5A Max.
Dimension
350 Width x 300 Height x 100 Depth (mm)
Weight
5Kg.
PANEL MOUNTING DIMENSION DETAIL
30
290
30235
300
35
175
350
Terminal Detail
24 VDC
_
Output +
P
230V AC
Input N
E
Ordering Information
Model Description
RE-2APS 2 Amps Power Supply
RE-5APS 5 Amps Power Supply
Features:
Compatible for 2 wire detectors.
?
Alarm status is indicated by red colour LED.
?
Operates on 12 VDC.
?
O
Dual LED’s for 360 visibility
?
Flush / Ceiling wall mount
?
Electrical Specification
Operating Voltage
? :12 VDC
Operating Current
? : 10mA
Alarm Indication
? : RED LED.
o
Operating Temperature
? : 0 C to 49oC.
o o
Storage temp
? : 0 C to 60 C.
Colour
? : Ivory.
Ordering Information:
Model Description
RE - RI 2 wire Response Indicator-Plate
*In the interest of improving quality and design, Ravel reserve the right to change the specification without prior notice. RE-RI / REV 00 / 2014-2015
RE 317D - SHL
Analogue Addressable Multi Detector
Product Overview
The RE 317D-SHL addressable multi detectors are designed to work
with Avani Panel. These detectors are low profile and have dual
LED’s for 360O visual indication. The blinking LED's indicate normal
operating condition whereas the steady state indicates fire status.
Features:
UL Approved.
?
O
Dual LED’s for 360 visibility.
?
Advanced detection and communication protocol.
?
Easy installation and maintenance.
?
Sleek low-profile housing design.
?
Regular 100mm base.
?
Max. 254 Address setting through 8 way DIP switch.
?
Electrical Specification
Operating Voltage : 17 ~ 28V DC
Reset Voltage : less than 3V
Standby current : 500 µA.
Start up time : 30s
Alarm Current : 5 mA.
Remote Output : 2mA maximum open collector
Thermal Rating : 59 OC (138 OF)
Rate of Raise of Temp : 11.1OC / min (20OF/min)
Smoke Sensitivity : (2.12 ± 0.61) % / ft
High : 1.1% ft
Middle : 1.4% ft
Low : 2.3% ft
Air Velocity : 0 - 4000 fpm.
Operating Temperature : -10 OC to 37.8 OC
Storage Temperature : -10 OC to 60 OC
Humidity : 0 - 95% RH, non-condensing
Mechanical Specification:
Height
? : 46 mm with base
Diameter
? : 100 mm dia
Weight
? : 150g with base
IP Rating
? : IP - 42
Wiring Diagram:
Note:
RI - Response Indicator
B - Standard Base
IB - Isolator Base
Compatible Device:
RE-314B - Normal Base
Ordering Information:
MODEL DESCRIPTION
RE317D-SHL Analogue Addressable Photoelectric & Heat Detector
*In the interest of improving quality and design, Ravel reserve the right to change the specification without prior notice. RE-317D-SHL / REV 01 / 2016-2017
RE 317D - SL
Analogue Addressable
Photoelectric Smoke Detector
Product Overview
The RE 317D-SL addressable detectors are designed to
work with Avani Panel. These detectors are low profile and
have dual LED’s for 360O visual indication. The LED’s are
blinking in normal operating condition whereas the steady
state indicates fire status. It has an unique chamber
designed to sense smoke produced by wide range of
sources of combustion. The detectors sensitivity can be
programmed through fire alarm control panel. It has a
unique drift compensation where the detector adjusts its
normal reference based on environment conditions.
Features:
UL listed.
?
O
Dual LED’s for 360 visibility.
?
Advanced detection and communication protocol.
?
Easy installation and maintenance.
?
Sleek low-profile housing design.
?
Regular 100mm base.
?
Address setting by 8 digit DIP switch.
?
Electrical Specification
Wiring Diagram:
Note:
RI - Response Indicator
B - Standard Base
IB - Isolator Base
Compatible Device:
RE-314B - Normal Base
Ordering Information:
MODEL DESCRIPTION
RE 317D - SL Analogue Addressable Photo electric smoke detector
*In the interest of improving quality and design, Ravel reserve the right to change the specification without prior notice. RE-317D-SL / REV 01 / 2016-2017
RE716P1TLP ( R )
Manual Pull Station
Product Overview
RE-716P Manual Pull Station is a high quality non-toxic die-cast manual pull station. Low profile design and
smooth edges offer an attractive yet functional design. All components are pre-painted or have plated surfaces
to inhibit corrosion. Electrically the RE-716P Manual pull station is unbeatable with 10 Amp snap action switch
offered in all possible contact arrangements (including gold contacts). The RE-716P pull station can be used
with or without a break glass rod, with replacement requiring no special tools.
Features
Ø Lift and pull
Ø Break glass cover
Ø Weather and Explosion proof versions
Ø All stations offer hex screw or key lock access.
Construction Material
Ø Painted Die Cast Housing.
Ø 14 Ga plated steel black plate.
Ø Corrosion Inhibited surfaces.
Ø Terminal block (4 Position)
Ø Single Gang Mounting
Ø 10 A , 120VAC snap Action Switch (S.P.S.T.)
Specification
Electrical
Switch : 10A@120VAC
Dimensions
Station Width : 3.200 in
Length : 4.750 in
Depth : 0.875 in
Weight 15.5 oz / 420 grams
Mount Single gang
Ordering Information
MODELS DESCRIPTION COLOR
RE716P1T Manual Pull station Single Action RED
RE716P1TLP( R ) Manual Pull station Dual Action RED
*In the interest of improving quality and design, Ravel reserve the right to change the specification without prior notice. RE-716P / REV 01 / 2016-2017
RE-716SO
SOUNDER
Product Overview
RE-716SO sounder is designed to deliver cost-efficient and reliable safety solutions which meet various
international standards to fulfil the industry’s needs. The RE-716SO sounders can be flush /
ceiling mounted with / without back box.
Features:
UL 464,UL - S525
?
Electrical Specification
1. Max. Current Draw : 25mA
2. Operating Voltage : 24V DC(16-33 VDC)/FWR
3. Mounting Options : Standard 4” *4” Back box
4. Sounder output : >= 75 dB at 16volts.
5. Compliance : UL 464,UL-S525
6. Wiring : 2 Wire Type.
7. Screw Terminals : #12 to #18 AWG Wires
Mechanical specification
@
Length : 140mm
@Width : 120mm
@Depth : 51mm
Wiring Details
NAC EOL
Output Horn Horn / Strobe Strobe
RE-716SO RE-716SS RE-716ST
RE-2554 / RE-2558 /
RE-25AR
FACP
Wiring Diagram as Addressable Horn
Compatible Device:
MODEL DESCRIPTION
Avani Analogue Addressable Fire Alarm Control Panel
RE-25AR Agent Release Panel
RE-2558/2554 4 & 8 Zone Fire Alarm Control Panel
Ordering Information:
MODEL DESCRIPTION
RE-716SO SOUNDER
*In the interest of improving quality and design, Ravel reserve the right to change the specification without prior notice. RE-716SO / REV 00 / 2016-2017
RE-717MC
Analogue Addressable Control Module
Product Overview:
RE-717MC Control Module is the remote switching device to
control 24V operating devices like Bells, Sounders, Strobes,
etc. The required supply is drawn from a 24V power supply
unit. The RED blinking LED indicates normal operating
conditions and the steady state LED for activated conditions.
DIP switches are provided for addressing of the module. The
output circuit is supervised for faulty condition.
Special Features:
Modular Construction.
?
Features:
Supervised a Class ‘B’ Style ‘Y’ output circuit.
?
Electrical Specification:
Operating Voltage : 24 VDC Nominal.
Current Draw : 2 mA Max.(Latched)
Standby Current : 0.5 mA
End of Line Resistor : 47K Ohms
Communication Line
Loop Impedance : 40 Ohms
Line Loss : 4 VDC Max.
External Supply Voltage : Regulated 24V.
Max. Output Current Drive : 1 Amps.(Supervised)
0oC to 49oC / 32 - 120 F
o o
Operating Temperature :
Storage Temperature : 0oC to 60oC.
Relative Humidity : 93 ± 2% RH (non-condensing) at 32 ±2° C / 90 ±3° F.
Mechanical Specification:
Dimensions : (95 W X 75 H X 24D) mm
Color : Black
Weight : 0.35 Kg
G.A.Diagram: Mounting Detail:
Wiring Configuration
24 VDC Power Supply
Regulated, Isolated, - To Next 47K EOL
Power Limited as per
NAC
NAC
NAC
NAC
Module Resistor
NFPA 70.
+ - RE-47K
Fire Listed
+
To Next
- Device or Panel
+
SIGNAL LINE
CIRCUIT (SLC)
28 VDC MAX.
-
+
From Panel or
NOTE: Use only with listed
compatible panels.
Previous Device
* D = NO CONNECTION
* ALL WIRING SHOWN IS SUPERVISED AND POWER LIMITED
Compatible Devices:
MODELS DESCRIPTION
Avani Analogue Addressable Fire Alarm Control Panel
Ordering Information:
MODEL DESCRIPTION
RE - 717MC Analogue Addressable Control Module
*In the interest of improving quality and design, Ravel reserve the right to change the specification without prior notice. RE-717MC / REV 01 / 2016-2017
RE -717MI
Analogue Addressable Isolator Module
Product Overview:
The Isolator module is an automatic device that isolates a part of
the loop by opening when the line voltage drops below 14Volts.
These modules should be spaced between groups of sensors or
modules in a loop to isolate the faulty area from the rest of the
loop. If a short occurs between any two isolators, then both
isolators immediately switch to an open state and isolate the
devices between them. The remaining units on the loop continue
to fully operate. Recommended to connect a maximum of 20
devices to each isolator. The module blinks indicating normal
status and a steady glow when activated.
Features:
Module Status by YELLOW LED.
?
Low Standby Current.
?
Available with suitable back boxes
?
Electrical Characteristics
Min Supply Voltage (Vmin)
? : 17V
Max Supply Voltage(Vmax)
? : 28VDC
Nominal Supply Voltage(Vnom)
? : 24VDC
Quiescent Current at 24V(Ic)
? : 30µA
Operating Temperature
? : 10 OC to 49 OC
Storage Temperature
? : 10OC to 60OC.
Leakage Current at 24V(IL)
? : 2 mA when isolating
Max Curent (through loop)(IS)
? : 1A continuous, 3A Peak
Isolating Voltage (Vco)
? : <14V
Maximum on resistance(Zc)
? : 0.02
Re-connect Voltage(Voc)
? : 14 ~ 16V
Mechanical Specification:
Dimensions : (95 W X 75 H X 24D) mm
Color : Black
Weight : 0.35Kg
G.A.Diagram: Mounting Detail:
Wiring Configuration
- To Next
Device or Panel
+
SIGNAL LINE
CIRCUIT (SLC)
28 VDC MAX.
-
+
From Panel or
Previous Device
Compatible Devices:
MODELS DESCRIPTION
Avani Analogue Addressable Fire Alarm Control Panel
Ordering Information:
MODEL DESCRIPTION
RE - 717MI Analogue Addressable Isolator Module
*In the interest of improving quality and design, Ravel reserve the right to change the specification without prior notice. RE-717MI / REV 01 / 2016-2017
RE-717MM
Analogue Addressable Monitor Module
Product Overview:
RE-717MM Monitor Module facilitates third party devices to
interface with Ravel addressable panels. Monitor Module is an
input interface device for devices like security contacts,
waterflow switches, pull stations, etc. The RED blinking LED
indicates normal operating conditions and the steady state LED
for activated conditions. DIP switches are provided for
addressing of the module. The Monitor circuit is supervised for
faulty condition.
Special Features:
Indian Manufacturer - International Standard.
?
Modular Construction.
?
Features:
Module Status by RED LED.
?
Electrical Specification:
Operating Voltage : 24 VDC Nominal.
Alarm Current : 2.7 mA Max.(Latched)
Standby Current : 0.7 mA
End of Line Resistor : 47K Ohms
Communication Line
Loop Impedance : 40 Ohms
IDC wiring Resistance : 100 Ohms Max.
IDC Voltage : 8 V Max.
0oC to 49oC / 32 - 120 F
o o
Temperature Range :
Storage Temperature : 0oC to 60oC
Humidity : 93 ± 2% RH (non-condensing) at 32 ±2° C / 90 ±3° F.
Mechanical Specification:
Dimensions : (95 W X 75 H X 24D) mm
Color : Black
Weight : 0.35 Kg
G.A.Diagram: Mounting Detail:
Wiring Configuration
+ 47K EOL
IDC
IDC
IDC
IDC
IDC
Resistor
RE-47K
-
To Next
- Device or Panel
+
SIGNAL LINE
CIRCUIT (SLC)
28 VDC MAX.
-
+
Use only with listed From Panel or
Previous Device
compatible panels .
NOTE:
* D = NO CONNECTION
* ALL WIRING SHOWN IS SUPERVISED AND POWER LIMITED
Compatible Devices:
MODELS DESCRIPTION
Avani Analogue Addressable Fire Alarm Control Panel
Ordering Information:
MODEL DESCRIPTION
RE - 717MM Analogue Addressable Monitor Module
*In the interest of improving quality and design, Ravel reserve the right to change the specification without prior notice. RE-717MM / REV 01 / 2016-2017
RE-717PMB
Backbox with Monitor Module
Product Overview
RE-717PMB pull station back box is compliant with latest standards and designed to interface Ravel
addressable Fire Alarm Control Panel. DIP switches are provided for addressing the device.
Features
Modular Construction
?
Specification
Operating Voltage : 24 VDC Nominal.
Alarm Current : 2.5 mA Max.(Latched)
Standby Current : 0.5 mA
Communication Line
Loop Impedance : 40 Ohms
0oC to 49oC / 32 - 120 F
o o
Temperature Range :
Storage Temperature : 0oC to 60oC
Humidity : 93 ± 2% RH (non-condensing) at 32 ±2° C / 90 ±3° F.
Mechanical Specification
Width : 84 mm
Length : 124 mm
Depth : 54 mm
Weight : 480 grams
Wiring Diagram
From Control Panel or + - To Next Device
Previous Device - +
Loop OUT
Loop IN
Ordering Information
*In the interest of improving quality and design, Ravel reserve the right to change the specification without prior notice. RE-717PMB / REV 01 / 2016-2017
RE-LC
Addressable Loop Card
Product Overview
RE-LC Loop Card for AVANI, intelligent addressable fire alarm control panel. Up to 254 devices can
be connected to a single loop card. These loop card can plugged in to slot provided in the motherboard of
Main panel (Avani). RE-LC Loop Card is compatible with Addressable Detectors, Manual Call Points,
Modules etc., The status of the loop shown by dual colouor LED.
Features:
Loop wise device test .
?
Lloop card can programmable as Class A, Style 5,6 or 7 and Class B Style 4 wiring.
?
Electrical Specification:
Signaling Line Circuit
.
No Devices per loop : 254
Loop resistance : 40 (Max.).
Loop capacitance : 0.6 µf (Max.).
Loop Current : 300mA (Max.).
Operating Voltage : 24VDC
Operating Temperature : 0 - 49° C / 32-120° F.
Relative Humidity : 93 ± 2% RH (non-condensing) at 32 ±2° C / 90 ±3° F.
Compatible Device:
MODEL Description
Avani Addressable Fire Alarm Control Panel
Ordering Information:
MODEL Description
RE-LC Addressable Loop Card
*In the interest of improving quality and design, Ravel reserve the right to change the specification without prior notice. RE-LC / REV 00 / 2015-2016
FEATURES
TECHNICAL SPECIFICATION - PART NO : IH226
01. BRAND NAME fladet series..
02 . MANUFACTURER AGNI CONTROLS, CHENNAI
3. ZONE/DETECTOR LINE
SERIES...
T RI PLE SEN SOR - U V & I R FLAM E DET ECT OR FOR
DAT A SH EET
H AZ ARDOU S AREA APPLI CAT I ON
PESO
UV & I R FL
R- AM
SO E
N
E
S
D
ET
E L
EC
TR I P
T OR
. .
S .
I E
R
E
KE S
E
E
IV
P
L
C
A
O
V S
E
R IT
TI
G CU
HT W E N C IR
H
RECOM M EN DED
M OU N T I N G ARRAN GEM EN T
R
I SO 9 0 0 1 - 2 0 0 8
CERT I FI ED BY
BU REAU V ERI T AS
R
SERIES...
T RI PLE SEN SOR - U V & I R FLAM E DET ECT OR FOR
DAT A SH EET
H AZ ARDOU S AREA APPLI CAT I ON
UV IR
fladet SERIES...
FM
APPROV ED
PESO
INSTALLATION CONSIDERATION :
Detector must be installed such that no obstruction is on the way of sight of the detector .
R
I SO 9 0 0 1 - 2 0 0 8
CERT I FI ED BY
BU REAU V ERI T AS