Download as pdf or txt
Download as pdf or txt
You are on page 1of 7

TRIBOLOGY MOTOR ONLINE PORTABLE

DIAGNOSTICS CONDITION MONITORING


MONITORING

BALANCING BORESCOPE ULTRASONIC INFRARED


THERMOGRAPHY

BALANCING REPORT
For
AFCO STEELS, Sheikhupura Factory.

FEB 10, 2020.


Corporate Head Quarter:
Sumico Technologies (Pvt) Limited, 185/J-1, M.A. Johar Town,
Lahore.Ph: +92-42-35315541-43, Fax: +92-42-35315540,
Email: info@sumico.com.pk, Web: www.sumico.com.pk

Attn: Mr. SHAHBAZ


AFCO STEELS, Sheikhupura Factory

Subject: On-Call BALANCING Report Performed on FEB 10, 2020.

Dear Sir,

We are pleased to submit you On-Call Balancing Report Performed on February, 2020.
We hope you will find this report complete in all respects.
However, if you feel any discrepancy please feel free to Contact us.

Thanks and best regards,


Yours truly,

For SUMICO Technologies Pvt. Ltd.

Dr. Anees Ur Rehman,


B.S c, M.Sc., PhD (Condition Monitoring),
CEng, MIMecE General Manager
(Operations)
Sumico Technologies
(Pvt) Limited. C: +92-
321-4974215
E: anees.rehman@sumico.com.pk

Balancing Report- AFCO STEEL- February, 2020. Page 2 of 7


Corporate Head Quarter:
Sumico Technologies (Pvt) Limited, 185/J-1, M.A. Johar Town,
Lahore.Ph: +92-42-35315541-43, Fax: +92-42-35315540,
Email: info@sumico.com.pk, Web: www.sumico.com.pk

TABLE OF CONTENTS
1. VIBRATION SEVERITY CHART......................................................................................... 4
2. ISO 1940-1:2003 (E).................................................................................................................. 5
3. BALANCING REPORT BLOWER FAN .............................................................................. 7
3.1 CONFIGURATION .......................................................................................................... 7
3.2 BALANCING JOB DESCRIPTION ............................................................................... 7

Balancing Report- AFCO STEEL- February, 2020. Page 3 of 7


Corporate Head Quarter:
Sumico Technologies (Pvt) Limited, 185/J-1, M.A. Johar Town,
Lahore.Ph: +92-42-35315541-43, Fax: +92-42-35315540,
Email: info@sumico.com.pk, Web: www.sumico.com.pk

1. VIBRATION SEVERITY CHART

The above chart, is only a guide, on the based on the ISO 10816 standard for general
machinery applications and does vary depending on the specifications/design of the
particular item of Plant & Machinery, installation and/or the operational parameters.

Balancing Report- AFCO STEEL- February, 2020. Page 4 of 7


Corporate Head Quarter:
Sumico Technologies (Pvt) Limited, 185/J-1, M.A. Johar Town,
Lahore.Ph: +92-42-35315541-43, Fax: +92-42-35315540,
Email: info@sumico.com.pk, Web: www.sumico.com.pk

2. ISO 1940-1:2003 (E)


This part of ISO 1940 gives specifications for rotors in a constant (rigid) state. It specifies
A) Balance Tolerances
B) The Necessary Number of Correction Planes
C) Methods for Verifying the Residual Unbalance.

Recommendations are also given concerning the balance quality requirements for rotors in a constant (rigid)
state, according to their machinery type and maximum service speed. These recommendations are based on
worldwide experience. This part of ISO 1940 is also intended to facilitate the relationship between the
manufacturer and user of rotating machines, by stating acceptance criteria for the verification of residual
unbalances.

Balancing Report- AFCO STEEL- February, 2020. Page 5 of 7


Corporate Head Quarter:
Sumico Technologies (Pvt) Limited, 185/J-1, M.A. Johar Town,
Lahore.Ph: +92-42-35315541-43, Fax: +92-42-35315540,
Email: info@sumico.com.pk, Web: www.sumico.com.pk

Balancing Report- AFCO STEEL- February, 2020. Page 6 of 7


Corporate Head Quarter:
Sumico Technologies (Pvt) Limited, 185/J-1, M.A. Johar Town,
Lahore.Ph: +92-42-35315541-43, Fax: +92-42-35315540,
Email: info@sumico.com.pk, Web: www.sumico.com.pk

3. BALANCING REPORT BLOWER FAN


3.1 CONFIGURATION

3.2 BALANCING JOB DESCRIPTION


PLANT SITE AFCO STEEL
Procedure Adopt Dynamic Balancing Balancing Plane Single Plane

Running Speed( RPM) 1000 RPM Equipment Description Air Blower Fan

Execution Engineer M. Ammad Elahi Qazi / Asim Ijaz Bhutta


Before Balancing
15.3 mm/sec Fan Inboard Horizontal
Maximum Unbalance Vibration
28.8 mm/sec Fan Outboard Horizontal
After Balancing
2.5 mm/sec Fan Inboard Horizontal
Maximum Unbalance Vibration
5.0 mm/sec Fan Outboard Horizontal

2.940 Kg @3140 Degree’s


Applied Weight
0.983 Kg @690 Degree’s

Balancing Report- AFCO STEEL- February, 2020. Page 7 of 7