HDPE Pipe Test Report
Sample Size
No Of Pipes Sample Size
Up to150 3
151-1200 5
1200-35000 8
CLAUS
S L NO E TEST RESULTS SPECIFIED REQUIREMENT
1 6 DIMENSION
6.1 Outside Diameter(mm) 90.50MM 90.0MM To 90.90MM
Ovality(mm) 0.80MM 1.8MM
2 6.2 THICKNESS
Min (mm) 5.66MM 5.4MM
Max (mm) 5.95MM 6.2MM
VISUAL APPEARANCE Satisfactory [Perforated Slight Shallow longitudinal
3 7 HDPE Pipe] grooves or irregularities in
wall thickness permissible
4 8.1 HYDRAULIC CHARATERISTICS
ACCEPTANCE TEST Passed Shall not show signs of
(Kg/cm2 @80'o C,48 Hours localized swelling leakage or
Weeping shall not burst
during the test duration.