Table of Contents
2
. IMPORTANT . IMPORTANT . IMPORTANT . IMPORTANT .
To assemble GV-HR110 follow the instructions below: 6) If the waterseal is mounted where the temperature can
1) Remember to switch off the electricity before fall below 0 C°, then the waterseal must be protected
opening the aggregate. against frost with a thermostat and an electric heating
2) An airtight waterseal must be mounted in a frost-free element that switches on when the temperature falls
place to compensate for the pressure from the below +2 C°.
ventilation unit. 7) Set the amount of incoming 1 - and outgoing air
3) The height of the waterseal must be at least 50 mm. before using the facility. It is very important that the
4) The pipe drain must fall freely to the sewer drain. air balance in the house is correct.
5) Pour 1 litre water into the condensation container of 8) It is recommended to close the air valves etc. until
the machine to check that the water flows without the machine has been started up and the settings
stoppage. The waterseal must be checked for water made.
every year before the cold season begins.
Follow the instruction in this manual. If the drain is not
set up in accordance with the manual, NIBE will not
be liable for any consequential damages pertaining to
the NIBE facility.
3
Subject to Technical Modifications of GV-HR110
7 10
GV-HR110 - Assembly
6 GV-HR110 is delivered upright or as horisontal.
9
8 The aggregate must be assembled on a vibrationfree,
firm substrate (cement, brick, etc.) or onto a solid wall.
Since the aggregate can produce up to 6 litres of water
14
5
per day during the winter months it must be placed
where the necessary waterseal and its condensation
drain-off can be lead off to in a satisfactory way to the
11 indoor drain.
12
In order to be able to service and maintain the
aggregate there must be at least 600 mm of space in
72,7 front of the aggregate and it must stand on a firm
substrate.
42
Weight: 32 kg
1014
1088
1056
60,7
24
32
550
128,6
135 280
2
265
13
550
4
Subject to Technical Modifications of GV-HR110
Concealed wall mountings Assembly
GV-HR110 is delivered with universal wall
mountings consisting of 2 rails.
Wall assembly
GV-HR110 can also be mounted directly on the
wall with visible or concealed wall mountings.
Cabinet assembly
GV-HR110 is made for mounting in
Visible wall mountings a normal 60 x 60 cm cabinet, as shown in the
drawing. When assembling a cabinet the aggregate
can be placed on the wall mounting delivered with
the aggregate (as shown in the picture).
Cabinet assembly
Horizontal mounting
Bottom of unit
when placed
montereshorisontally
bunden af maskinen i tilfælde
at maskinen vandret
Feet as
delivered
gummifødder, som leveret
When mounted
ved vandret montage af
maskinen skal de leverede
gummifødder flyttes til
positioner som anvist her
horisontally, place
feet as shown
5
Subject to Technical Modifications of GV-HR110
Duct connection
All duct connections have yellow markings that
Exhaust air indicate which ventilation ducts are connected to the
different connections.
Fresh air Supply air
Incoming air connection:
The duct system from the aggregate to the residence.
Condensation drain
The aggregate produces up to 6 litres condensation
per day. It is therefore important that the condensation
drain is set up correctly and that the aggregate declines
toward the condensation drain side.
No water in the waterseal = water damages During operation there is negative pressure in the
aggregate, which makes it necessary to guarantee
a height difference of at least 50 mm down to the
water in the waterseal.
6
Subject to Technical Modifications of GV-HR110
Duct system
We recommend that the duct system be made of
spiralflanged pipes and couplings made with rubber
ring seals to assure a sealed, durable duct system.
1m
Make sure that the closures are tight where the exhaust
air duct comes through the roof or through the gable so
Forkert isolering
Incorrect insulationafofkanaler
ducts Insulation
Isolering af ofkanaler,
ducts, alt.alt.
B B
that damage from condensation is avoided.
7
Subject to Technical Modifications of GV-HR110
Insulation of ducts in warm rooms
Incoming and outgoing air ducts:
In hot attic rooms the incoming and exhaust air ducts
must be insulated with 50 mm insulation with aluminium
foil outermost.
Electric postheater:
The control sensor for the electric postheater is mounted
in the incoming air duct approx. 500 mm behind the
electric postheater, so that it will not be affected by the
radiant heat from the heating element.
8
Subject to Technical Modifications of GV-HR110
Electric installations
The electric installations must be performed by an
authorised electrician. See the electric wiring diagram
included. The cable between the aggregate and control
panel is a 4-lead cable, max. 50m.
The facility can now be used and run until the facility
is adjusted using technical ventilation measurement
instruments.
9
Subject to Technical Modifications of GV-HR110
Facility maintenance
Filter:
When the red light flashes on the control panel
the filter must be changed/cleaned.
The facility is turned off with the facility switch or with
the switch by the fuse cabinet. It is not necessary to
G4 = Standard filter (Coarse filter class remove the lid to exchange the filter. The filter unit can
G4) F7 = Pollen filter (Fine filter class F7) only be opened by turning both knobs one quarter turn
counter-clockwise (to the left). The filter unit is pushed
into place by reversing the procedure; both knobs must
be turned one quarter turn clockwise (to the right).
When the filter has been exchanged or cleaned by
shaking them to remove most of the dirt, the filter timer
is set by pressing ”Enter” for 10 to 15 seconds until the
NIBE-logotype flashes once again and the facility is
back to normal operation.
If you want to clean the filter at another time interval, this
can be adjusted in item 14 of the Operations menu,
The incoming air filter (F7) on the left side is higher up
than the outgoing filter (G4).
10
Subject to Technical Modifications of GV-HR110
Condensation drain:
When it is time to exchange the filter in the fall, check the
condensation drain for fouling by dirt and make sure there
is water in the waterseal. The waterseal must not dry out
since the negative pressure of the aggregate will suck air
into the aggregate causing the condensation to remain in
the aggregate. Pour 1 litre of water into the condensation
container and check that the flow is undeterred. If the
condensation drain does not work correctly water damages
may occur in the residence.
Fans:
Remember to switch of the power supply!!
Check the fans in the fan wheel for dirt every third year.
The four outermost screws that hold the fans in place
must be removed in order to remove the fans. Remove
the front lid of the unit. Clean the fans using a brush, fan
brush or paintbrush.
11
Subject to Technical Modifications of GV-HR110
Troubleshooting Display message:
Computer error:
Turn off the facility - no connection with circuit board
No lamps are lit on the service panel, even when you press on - lead too long between display and circuit card
both buttons.
Error:
- A fuse has blown in the fuse box, no power supply to the facility.
Version error:
- One of the fuses on the circuit board has shorted. - Program displayed and circuit card not compatible
- Loose contact, no voltage to the aggregate.
- Loose contact between the aggregate and control panel. Exchange filter:
- Filter must be changed
Red light constantly lit on the control panel:
Error for control: Stop ON-OFF:
- Frost thermostat switched off. (Facilities with water heaters.) - Filter has not been exchanged/cleaned within 14 days
- Faulty sensor in aggregate from the filter alarm being triggered.
- Faulty sensor in control panel The facility is turned off.
- If no sensor is attached for incoming air it has been replaced
by a resistor that is faulty
- Loose sensor wire or loose bridge in coupling list on the circuit
board.
12
Subject to Technical Modifications of GV-HR110
Electric wiring diagram GV-HR110
PE
ES960
L1 L2
1 2 1 2 3 4 1 2
Q1=1,6A
Q2=1,0A
Q3=6,0A
L3
1 2 3 4 5 6 7 8 H2 H3
1 2 1 2
L6
1 2 3 4 5 6 7 8
R2
R3
H6 H7
1 2 1 2
L8
1 2
H8 H9
1 2 3 1 2
L11
1 2 3 4
A B
13
Subject to Technical Modifications of GV-HR110
Electric wiring diagram GV-HR110
! "#$$% &'%
! "#$$% &'%"
! "#$$% (%%
! "#$$% (%%"
!""!## !""!#$ !""!%" !""!%& $'(!!' $'(!!(
) * + , -
* , - . /
- * + ,
0 - -
1 + - + ,
)
2 / (!!" %( +3 '45 / (!!"
2 6 . (!!" $4 +) '(5 7 (!!"
2 + 3 (!!% '!8 +3 '45 7 (!!%
2 9 : $$ 4 +3 $5 / '$$$
2 9 0, (!'' "4 +) 85 ; (!''
* + , -
2 * 5 &$& '&5 < (!!$
2 6=> 5 8(# #5 ; (!!&
2 * 5 &%# (#5 , '$$$
2 <: * 5 "'( (45 ; (!!85
./
2 "!##4 ' <'# <'% ?
2 "!##4 ( %! @ ?
2 44!'% '
2 44!'% ( ! "
A B )
3 @ ,
A B 7 )
* + , /
0 - 4 ((5 * - (!'#
,+ (84(' /
@ ; > /
C@/ 7 2 CD / 2
15
Subject to Technical Modifications of GV-HR110
KNV Energietechnik GmbH, Gahberggasse 11, 4861 Schörfling
AT
Tel: +43 (0)7662 8963-0 Fax: +43 (0)7662 8963-44 E-mail: mail@knv.at www.knv.at
Druzstevni zavody Drazice s.r.o, Drazice 69, CZ - 294 71 Benatky nad Jizerou
CZ
Tel: +420 326 373 801 Fax: +420 326 373 803 E-mail: nibe@nibe.cz www.nibe.cz
Vølund Varmeteknik A/S, Member of the Nibe Group, Brogårdsvej 7, 6920 Videbæk
DK
Tel: 97 17 20 33 Fax: 97 17 29 33 E-mail: info@volundvt.dk www.volundvt.dk
NIBE Energy Systems Ltd, 3C Broom Business Park, Bridge Way, Chesterfield S41 9QG
GB
Tel: 0845 095 1200 Fax: 0845 095 1201 E-mail: info@nibe.co.uk www.nibe.co.uk
ABK AS , Brobekkveien 80, 0582 Oslo, Postadresse: Postboks 64 Vollebekk, 0516 Oslo
NO
Tel. sentralbord: +47 23 17 05 20 E-mail: post@abkklima.no www.nibeenergysystems.no