E/H Actuator
Case History: Failure of the E/H Actuator on the DIRECT DRIVE ACTUATORS
Governing valve of a Turbine (30 MW, 3950 rpm) occurred
after initial days of operation. The Actuator was properly A linear electro-hydraulic actuator designed to provide the
commissioned before the operation started. After initial check, linear actuation force to operate steam turbine control valves or
actuator piston was found stuck due to dirt. Further valve racks which uses a low-pressure hydraulic oil source
(typically turbine lube oil) to provide its output shaft force.
investigation revealed that the initial flushing of oil pipe was
CONCLUSIONS
ABBREVIATIONS
ACKNOWLEDGEMENTS