Product Nav DVOR 1150

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

ILS Systems VOR Systems DME Systems RCSU Systems

MODEL 1150
VHF Omni-Directional Range

The Model 1150 VOR is one of the most advanced navaid systems
in the industry today. Our performance record for safety and
reliability is respected worldwide.

PRODUCT OVERVIEW
With systems sold and in service worldwide, the Model 1150 VHF
Omni-Directional Range (VOR) has become the international
standard for high reliability in en-route navigational and approach
systems. Available in doppler, conventional, mobile and trans-
portable configurations, the 1150 offers Windows™ based remote
maintenance monitoring and control, automatic VSWR and ground
check features, and built-in test. The 1150 provides advanced
performance, highly dependable operation and ease of mainte-
nance. Like all SELEX products, the 1150 is certified by the
U.S. Federal Aviation Administration and meets or exceeds ICAO
Annex 10 recommendations.

ADDITIONAL FEATURES INCLUDE:


• Dual and Single Equipment Configurations
• Comprehensive Windows™ graphical based RMM:
– Fault Diagnostics
– Remote
Wind: In excess of 100 mph (161 km/h).
• Configuration/Control
– Monitoring and Recording
Ice and Snow: Two-inch (5 cm) ice coating causes negligible
• Dual Independent Monitoring
course error.

SPECIFICATIONS
ELECTRICAL
MECHANICAL
Primary Power: 110/220 volts AC ± 10%, 47 to 63 Hz, single
Weight: 1150 VOR: 193 lbs (87.5 kg). 1150 Commutator: 70 lbs
phase.
(31.75 kg).

Frequency Band: Frequency 108.05 to 117.95 MHz.


Dimensions: 19"W x 15"D x 41"H (48.26 cmW x 38.1 cm D x
104.8 cmH).
Frequency Source: Synthesizer

Environmental Temperature: -10°C to+55° temperature for


Frequency Stability: ±0.0005% (5ppm).
equipment installed in the shelter. All other equipment such
as antennas and cables: -50°C to+70°C.
Power Output: Transmitter output adjustable from 50 to 100 W in
1 watt increments (17 to 20 dbw). (Effective Radiated Power (ERP)
Relative Humidity: Above 95%.
23 dbw minimum.)

Altitude: 0 to 4573m (15,000ft) MSL.


Hum and Noise: With voice, VOR reference and identification
inputs applied, hum and noise on the carrier are more than 30 db
Duty Cycle: Continuous.
below the audio level, equivalent to 30% modulation.
Maximum Range: Line-of-sight limitation, 175 nautical miles at VOR Variable: 9960 Hz ± 1% upper and lower sidebands modulate
37,500 feet above the facility. the carrier at less than 40% when measured at 300 m or greater.
Digital blending with a cos .836 x envelope.
Azimuth Index: Station azimuth fully adjustable in 0.01° increments
over a range of ± 50°. Tone Identification: AM adjustable (5% typical) with keyed 1020 Hz
± 0.5%. Identification keying to a collocated DME is standard.
Spurious Outputs: Greater than 77 db below the carrier at 30%
modulation. CVOR
Semi Automatic 16-point Ground Check: standard.
Harmonic Radiation: Meets or exceeds ICAO requirements.
Fully Automatic 16-point Ground Check: optional kit for accurate
System Accuracy: ±1°. azimuth measurement at 16 points around CVOR via menu
selection.
CVOR Ground Check Tolerances: The maximum spread of any
ground check error curves are less than 2.0°. DVOR
Standard Antenna VSWR monitoring and field detector ‘notch’
Equipment: Model 1150 includes built-in test equipment and test monitoring standard. Fully automatic DVOR ground check system
points necessary to achieve and maintain system performance standard.
with a minimum of maintenance.
CVOR & DVOR
Monitors: Dual parallel AND/OR configuration, built-in test Auto ground checks include a Fourier Analysis of the signal,
generator for monitor certification and calibration. automatic screen plot and printing of error curves for analysis,
thus reducing maintenance, down time and flight inspection
RMM: Comprehensive, includes alarms, pre alarms and requirements by signal verification after maintenance.
maintenance alerts with automatic dial out to any telephone
number. Smoke, intrusion sensors (optional) ANTENNA SPECIFICATIONS
Antenna Polarization: Horizontal.
CVOR MODULATION
VOR Reference: Sideband 9960 Hz frequency modulated at 30 Hz Antenna Configuration: Slotted or 4 Alford Loop - CVOR, 48+1
± .02% with a deviation ratio of 16 to 1 (±1). Amplitude modulates Alford Loop - DVOR.
the carrier at 30% ± 2%.
Frequency Range: 108 to 118MHz.
VOR Variable: 30Hz ± .02% amplitude modulates the carrier 30%
± 2%. Impedance: 50 ohms

DVOR MODULATION VSWR: <1.2:1.


VOR Reference: 30 Hz ± .02% amplitude modulates the carrier
30% ± 2%.

SELEX Sistemi Integrati Inc. www.www.selex-si-us.com


11300 W. 89th Street
Overland Park, Kansas 66214 USA
Tel: 913-495-2600
Toll Free: 1-800-765-0861
Fax: 913-492-0870
This publication is issued to provide outline information only and is
supplied without liability for errors or omissions. No part of it may
be reproduced or used unless authorized in writing. We reserve the
right to modity or revise all or part of this document without notice.