Professional Documents
Culture Documents
Revised 250120 Without PUF Waterproofing Comparative
Revised 250120 Without PUF Waterproofing Comparative
Revised 250120 Without PUF Waterproofing Comparative
TOP SHEET
AREA ( SFT) #REF!
S.No DESCRIPTION TOTAL AMOUNT COST PER SFT
Providing & laying HDPE Membrane waterproofing system below RCC foundation / raft.
Waterproofing should create 100% water tight and chemical barrier around the structure.
All complete to approval of PM.
Providing and installing positive side waterproofing treatment for “Raft Slab” by using
approved 1.2mm thick fully bonded HDPE sheet membrane before casting of Raft slab.
Membrane shall be installed in strict accordance with the manufacturer’s instructions and
shall provide an intimate bond to resist water migration. The fully bonded HDPE sheet
membrane shall consist of a multi layer composite film which consists of highly resilient
HDPE film, self adhesive polymer layer and a trafficable particulate layer. The fully bonded
HDPE sheet waterproofing membrane shall have following typical properties : 1) Colour-
White 2) Hydrostatic Head Resistance at laps - 70 m head of water as per ASTM D5385; 3)
Water migration Resistance: 70 m head of water as per ASTM D5385; 4) Elongation- 400%
5) Peel adhesion to concrete: >550N/m (ASTM D 903 Modified) 6) Low Temp Flexibility: Sqm
-25°C, pass (ASTM D 1970) 7) Puncture Resistance - 800N (as per ASTM E154)
Membrane shall be installed with standard 75mm selvedge laps, and end laps executed
with Fixer, applied as per manufacturer’s instructions. Membrane shall be laid over the
entire area and returned on to a vertical slab formwork. Hot applied materials or protective
screed shall NOT be permitted. All systems to be installed as per manufacturer's
recommendations, etc. complete with all lead and lift for all materials and labour and as
directed by PM.
Providing & laying HDPE Membrane waterproofing system on outside surface of RCC
retaining walls of approved self adhesive, cold applied, flexible 1.5mm thick waterproofing
membrane comprising of a self adhesive rubberized asphalt with a unique composite film
engineered for strength, flexibility & a smooth finish with a pre-marked minimum 50 mm
overlap aid applied on the uniform concrete surface. The self adheisve membrane shall
confirm to BS 8102:2009 for protection of all basement types and shall have following
minimum properties :
(i) Puncture resistance of 220 N (ASTM E154 -88)
(ii) Resistance to Hydrostatic head of > 50m (ASTM D 5385)
(iii) Tear resistance of 23N/mm (ASTM D 624 modified)
(iv) Tensile resistance of 4N/mm (ASTM D412 modified)
(v) Elongation of membrane (to ultimate failure of rubberised asphalt) - 200% (ASTM D412
modified)
(vi) The membrane should be resistant to sulphate, nitrates & salt in soil.
- Make 20mm x 20mm chase/rebate on the vertical wall for termination of the membrane.
The chase/rebate shall be adequately sealed with approved single component flexible
polyurethane sealant.
- The laid membrane shall be protected with a 25mm thick approved expanded polystyrene
of 24kg/cum density to be placed directly on membrane before backfilling. Sqm
Roof Waterproofing above Insulation: Providing and applying a solvent free two component
spray applied polyurathene waterproofing 1.2 mm thick. Spray Waterproofing shall be
highly reactive and can only be applied by special, two component spray equipment. The
mixed product should have 100% Solids Content as per DIN 53213, Density ratio of PA:
PB shall be 1.06:1.10 g/cm3, Tensile Strength should be in range of 8 – 10 Mpa as per
Sqm
DIN 53504, Elongation of > 400% as per Din 53504 and Green Certified. It shall have the
following features and benefits · be fast reacting sets within 30 sec, · have excellent
crack bridging capability shall be >2mm ·be root resistant passed as per DIN 4062, ·
should remains elastic at low temperatures including 300 GSM Geotextile with 50mm
overlap.
All around on the roof, at the parapet wall junction, an angular fillet of 50 mm X 50 mm
shall be trowel applied in cement-sand mortar Curing of the concrete screed & angle fillet
Metre
shall be done as per regular concrete curing practices, by means of regularly wetting a
hessian cloth.
Providing and applying a solvent free two component spray applied polyurathene
waterproofing 1.2 mm thick. P.U.shall be applied after necessary surface preparation
followed by application of moisture insensitive epoxy primer sand broadcasting as per
manufacturer specifications. Spray Waterproofing shall be highly reactive and can only be
applied by special, two component spray equipment. The mixed product should have
100% Solids Content as per DIN 53213, Density ratio of PA: PB shall be 1.06:1.10 g/cm3,
Tensile Strength should be in range of 8 – 10 Mpa as per DIN 53504, Elongation of >
400% as per Din 53504 and Green Certified. It shall have the following features and Sqm
benefits be fast reacting sets within 30 sec, have excellent crack bridging capability shall
be >2mm be root resistant passed as per DIN 4062, should remains elastic at low
temperatures. The application of entire roof waterproofing shall be done by authorized
applicator of approved manufacturer and all materials specified shall be sourced from
single manufacturer. Including 300 GSM protection geotextile.
Providing & laying a protection layer of 25 mm thick cement mortar admixed with Integral
f Sqm
waterproofing compound at site
TOTAL AMOUNT
1 Payment terms
3 Validity of quote
4 Client scope
5 Warrantee
As ACME is consistently quoting the lowest price and if the Technical Data Sheets
approved by the Consultants, the work may be awarded to M/s ACME
K - 02
TATEMENT R
e
ACME (Asian Paints) v Nina Percept (Pidilite) Civiltech Engineers
i
s Mr. Manish Sharma Mr. Manotsh Tiwari
Mr. Ankur Atrey e Mob 85274 98598 Mob 88608 00273
Mob 9599387534 d Mob 98711 20735
o
Quantity Rate Amount Quantity Rate Amount Remarks Quantity Rate
n
Revised on 24.Jan.2020 Revised on 24.Jan.2020 R0 submitted on 13012020
2
3
.
J
a
n
.
2
2415 310 748,650 0 2,415 447 1,079,505 2415 615
2
0
29,206,367 36,092,022
L1 L3 L5
45,303,230 30,391,109
L5 L2 L4
Amount Remarks
R1 submitted on 23012020
Considered :
Cleaning / Pre-
Ponding /
Grouting / Pipe
Sealing only at
2,033,430 junctions & at
top, filling of
Gap between
pipe & core cut
not included/
Gola
Pipe Sealing
item
1,456,000
considered in
item no. 3.1
Plan Area
12,156,264 Clause not
applicable
Plan Area
2,246,092 Clause not
applicable
considered
10% Vertical
7145728 Area in Plan
Area
Calculation
Plan Area
46650 Clause not
applicable
considered
10% Vertical
11,918,580 Area in Plan
Area
Calculation
Plan Area
217,500 Clause not
applicable
Plan Area
5,276,100 Clause not
applicable
Plan Area
1,025,100 Clause not
applicable
43,521,444
L4