Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

CUSTOMER NAME Appendix xx Project: ????

Minimum Wall Thickness 26 Jun 2015


Rev. P?
Design Code ASME I
Section PG-27.2.1 Tubing -up to and including 5 in. OD

Tube Location Economizer


Tube Material SA-178 A Carbon steel Welded tube
Tube Dimensions 50.8 mm x 3.43 mm 2 "x 0.135 "
Minimum wall 3.43 mm Ref. SA-450, Table 2 0.135 "
Maximum wall 4.05 mm Ref. SA-450, Table 2 0.159 "
Pressure 5,344 kPa Deltak boiler datasheet 775 psi
Temperature 269.3 °C Saturated 516.8 °F
Maximum Permissible Temp' 537.8 °C Ref. Table 1A, ASME IID 1,000.0 °F
Tube Temperature 319.3 °C 606.8 °F
Design Temperature 371.1 °C 700.0 °F
Allowable stress 85.5 MPa 12,400 psi

P= 5.344 MPa maximum allowable working pressure


D= 50.8 mm outside diameter of tube
S= 85.5 MPa maximum allowable stress (ASME section II part D)
w= 1.0 weld joint efficiency factor, Ref. Table PG-26
e= - thickness factor for expanded tube ends (PG-27.4, Note 4)
tmin = 1.793 mm 0.071 "
2.428 mm Alstom recommended thickness 0.096 "

Static Head 3.201 m PG-27.4.10 need not be included 10.5 ft


Density 768 kg/m³ 48.0 lb/ft³
Static Pressure 24.1 kPa 3.5 psig
Percentage 0.5 %

36247 - Boiler Pressure Parts Thickness.xlsx Prepared By


Economizer Leonine International Inc. Page 1 of 1