TECHNICAL SERVICE REPORT

Euro Facade Tech Manufacturing Sdn.Bhd.


Lincoln Square

Project Number: Test-costs:


00676-CN-00036-RZ 2500 RMB
Requestor:
Vincent Yan
Distribution List Customer:

Distribution List Sika:

SIKA SERVICES AG
Technical Service

Responsible: Technician:
Wenyou Ma Ryan Zhao
22/08/2019 15/07/2019

TECHNICAL SERVICE REPORT Sika (China) LTD


00676-CN-00036-RZ 28 Jindong Road, Suzhou Industrial Park,
2019/08/22, CN Jiangsu, China
Euro Facade Tech Manufacturing Sdn.Bhd. www.sika.com

1/6
TASK
Adhesion test with Sika® products on the submitted samples.

SUMMARY
1. Adhesion test
Test results show that the adhesive system below can achieve good bonding effect:
Sample: Misty lvory Lime stone
IPA + Sikaflex®-11FC Grey
IPA + Sika® Primer-210 + Sikaflex®-11FC Grey

REMARKS
The results only apply to the tested quality.
Constant/reproducible surface quality is required.
Any changes can result in adhesion loss.
Direct contact between Sikasil® and SikaHyflex® products with sulfur curing gaskets is not approved.
Surface pre-treatment always includes surface cleaning as first step (cf. para. "Method of Application" in the
relevant Product Data Sheet) and application of adhesion promoter as second step.
Compatibility test methods are based upon valid standards, RAL as well as other guidelines.
Compatibility test results between non-Sika materials and Sika sealants and adhesives are generally batch-related,
since Sika has no control over the manufacturing process of third-party products.
Nevertheless, the results may be transferred to other batches as long as it can be ensured that the formulations,
the raw materials, the production process or other important parameters which may influence the compatibility
are not altered.

TECHNICAL SERVICE REPORT Sika (China) LTD


00676-CN-00036-RZ 28 Jindong Road, Suzhou Industrial Park,
2019/22/08, CN Jiangsu, China
Euro Facade Tech Manufacturing Sdn.Bhd. www.sika.com

2/6
TEST METHODS
CQP 033-3 - Bead adhesion test for Industry silicones
CQP 034-1 - Conditions for accelerated ageing of test specimens
CQP 034-2 - Designation of failure patterns for bead adhesion tests

UTILITIES

CLEANER/ACTIVATORS Batch No. / best before


IPA /

PRIMER Batch No. / best before


Sika® Primer-210 3003464420

ADHESIVE/SEALANT BATCH NO. / BEST BEFORE


SikaFlex® 11FC Grey 00148816

SUBSTRATE Detail
Stone Sample 1: Misty lvory Lime stone
Supplier:Stone Empire Marketing Sdn Bhd

TECHNICAL SERVICE REPORT Sika (China) LTD


00676-CN-00036-RZ 28 Jindong Road, Suzhou Industrial Park,
2019/22/08, CN Jiangsu, China
Euro Facade Tech Manufacturing Sdn.Bhd. www.sika.com

3/6
Test method: CQP 033-3 - Bead adhesion test for Industry silicones

Substrate: Sample: Misty lvory Lime stone:Supplier:Stone Empire Marketing Sdn Bhd

Pre-Treatment 1 Pre-Treatment 2 t [min] Pre-Treatment 3 t [min] Adhesive Results


B B C E
IPA 10 Sikaflex®-11FC Grey 1 1 1 1
IPA 10 Sika® Primer-210 30 Sikaflex®-11FC Grey 1 1 1 1

TECHNICAL SERVICE REPORT Sika (China) LTD


00676-CN-00033-RZ 28 Jindong Road, Suzhou Industrial Park,
2019/08/08, CN Jiangsu, China
H.K.L METAL WORKS www.sika.com

4/6
Notation for the Results
Notation Exposure
A 1d KLR
B 7d KLR
C 7d WL 23°C + 2h KLR
D 7d 40°C/95%rh. + 2h KLR
E 7d 70°C + 2h KLR
F 1d 80°C
G 2h KLR
H 3d -30°C + 2h KLR
I 7d 80°C + 2h KLR
J 3d 80°C
K 2h KLR
L 7d CP + 2h KLR
M 7d CP + 1d -30°C + 2h KLR
N 10 cycles VDA + 2h KLR
O 20 cycles VDA + 2h KLR
P 7d WL 55°C + 2h KLR
Q 7d 35°C/90%rh + 2h KLR
R 7d WL 40°C + 2h KLR
S 7d 100°C + 2h KLR
T 7d 55°C/98%rh + 2h KLR
U 1000h 85°C/85%rh + 2h KLR
V 10 cycles (20h 85°C/85%rh + 4h -40°C) + 2h KLR
W 7d 40°C + 2h KLR

KLR Exposure at 23°C/50% r.h. acc. to ISO 554 also called RT, AC
WL Full Immersion in deionized water at indicated temperature
CP Cataplasma storage at 70°C fully saturated humidity ≈98%rh
VDA Cycletest acc. to VDA 621-415 (1 cycle = 7 days)
xh x hour(s)
xd x day(s)

The test results are analyzed as shown in the Tables below:


Note Assessment Bond
1 Bond satisfactory > 95% cohesion failure
2 Bond basically satisfactory > 75% cohesion failure
3 Bond not satisfactory > 25% cohesion failure
4 Bond not satisfactory < 25% cohesion failure
5 Bond not satisfactory 0% cohesion failure

Additional rating for the adhesive Rating of mixed rupture mode


Index Assessment
TU Tunnel effect/edge bonding
UC Adhesive is not fully cured
SCF Substrate close cohesive failure (substrate visible)
FS Foam structure on the bond surface (fine bubbles)
BA Bubbles in adhesive
ES Edge separation
NT Not tested

Additional rating for substrates


Index Assessment
BS Bubbles/voids on the substrat's surface
SF Substrate failure (failure in fibers or layers of non-coated substrates
CR Chipping of the coating (paints, etc)
PR Rupture in the primer
Cor Corroded substrate
PT Partial adhesion loss of primer to substrate (tunnel)
Note:
If no additional designation is given, the failure area (for adhesive failure) is between the adhesive and the layer applied last. Different failure
modes should be described.

TECHNICAL SERVICE REPORT Sika (China) LTD


00676-CN-00033-RZ 28 Jindong Road, Suzhou Industrial Park,
2019/08/08, CN Jiangsu, China
H.K.L METAL WORKS www.sika.com

5/6
Legal Note:
The information contained herein and any other advice are given in good faith based on Sika's current knowledge and experience
of the products when properly stored, handled and applied under normal conditions in accordance with Sika's
recommendations. The information only applies to the application(s) and product(s) expressly referred to herein. In case of
changes in the parameters of the application, such as changes in substrates etc., or in case of a different application, consult
Sika's Technical Service prior to using Sika products. The information contained herein does not relieve the user of the products
from testing them for the intended application and purpose. All orders are accepted subject to our current terms of sale and
delivery. Users must always refer to the most recent issue of the local Product Data Sheet for the product concerned, copies of
which will be supplied on request.

Validity:
The validity of this report expires if any of the parameters of the application(s) have changed, but in any event, two years after its
date of issuance.