SIKA SERVICES AG
Technical Service
Responsible: Technician:
Wenyou Ma Ryan Zhao
22/08/2019 15/07/2019
1/6
TASK
Adhesion test with Sika® products on the submitted samples.
SUMMARY
1. Adhesion test
Test results show that the adhesive system below can achieve good bonding effect:
Sample: Misty lvory Lime stone
IPA + Sikaflex®-11FC Grey
IPA + Sika® Primer-210 + Sikaflex®-11FC Grey
REMARKS
The results only apply to the tested quality.
Constant/reproducible surface quality is required.
Any changes can result in adhesion loss.
Direct contact between Sikasil® and SikaHyflex® products with sulfur curing gaskets is not approved.
Surface pre-treatment always includes surface cleaning as first step (cf. para. "Method of Application" in the
relevant Product Data Sheet) and application of adhesion promoter as second step.
Compatibility test methods are based upon valid standards, RAL as well as other guidelines.
Compatibility test results between non-Sika materials and Sika sealants and adhesives are generally batch-related,
since Sika has no control over the manufacturing process of third-party products.
Nevertheless, the results may be transferred to other batches as long as it can be ensured that the formulations,
the raw materials, the production process or other important parameters which may influence the compatibility
are not altered.
2/6
TEST METHODS
CQP 033-3 - Bead adhesion test for Industry silicones
CQP 034-1 - Conditions for accelerated ageing of test specimens
CQP 034-2 - Designation of failure patterns for bead adhesion tests
UTILITIES
SUBSTRATE Detail
Stone Sample 1: Misty lvory Lime stone
Supplier:Stone Empire Marketing Sdn Bhd
3/6
Test method: CQP 033-3 - Bead adhesion test for Industry silicones
Substrate: Sample: Misty lvory Lime stone:Supplier:Stone Empire Marketing Sdn Bhd
4/6
Notation for the Results
Notation Exposure
A 1d KLR
B 7d KLR
C 7d WL 23°C + 2h KLR
D 7d 40°C/95%rh. + 2h KLR
E 7d 70°C + 2h KLR
F 1d 80°C
G 2h KLR
H 3d -30°C + 2h KLR
I 7d 80°C + 2h KLR
J 3d 80°C
K 2h KLR
L 7d CP + 2h KLR
M 7d CP + 1d -30°C + 2h KLR
N 10 cycles VDA + 2h KLR
O 20 cycles VDA + 2h KLR
P 7d WL 55°C + 2h KLR
Q 7d 35°C/90%rh + 2h KLR
R 7d WL 40°C + 2h KLR
S 7d 100°C + 2h KLR
T 7d 55°C/98%rh + 2h KLR
U 1000h 85°C/85%rh + 2h KLR
V 10 cycles (20h 85°C/85%rh + 4h -40°C) + 2h KLR
W 7d 40°C + 2h KLR
KLR Exposure at 23°C/50% r.h. acc. to ISO 554 also called RT, AC
WL Full Immersion in deionized water at indicated temperature
CP Cataplasma storage at 70°C fully saturated humidity ≈98%rh
VDA Cycletest acc. to VDA 621-415 (1 cycle = 7 days)
xh x hour(s)
xd x day(s)
5/6
Legal Note:
The information contained herein and any other advice are given in good faith based on Sika's current knowledge and experience
of the products when properly stored, handled and applied under normal conditions in accordance with Sika's
recommendations. The information only applies to the application(s) and product(s) expressly referred to herein. In case of
changes in the parameters of the application, such as changes in substrates etc., or in case of a different application, consult
Sika's Technical Service prior to using Sika products. The information contained herein does not relieve the user of the products
from testing them for the intended application and purpose. All orders are accepted subject to our current terms of sale and
delivery. Users must always refer to the most recent issue of the local Product Data Sheet for the product concerned, copies of
which will be supplied on request.
Validity:
The validity of this report expires if any of the parameters of the application(s) have changed, but in any event, two years after its
date of issuance.
6/6