Course code/name
Rancidity is the complete or incomplete oxidation or hydrolysis of fats and oils when exposed to air, light,
moisture or by bacterial action. This can be results of unpleasant taste and odor. Hydrolysis or
autoxidation of fats is change of aldehydes and ketones short-chain. In oxidative rancidity oxygen is taken
up by the fat with the formation of peroxides. The degree of peroxide formation and the time taken for the
development of rancidity are differ among oils type.
Peroxide value is a measure of peroxide contained in oil which in this experiment it will be determined by
titration against thiosulphate solution in the presence of concentrated potassium iodide (KI) and starch as
the indicator. The assessment of hydroperoxides provides an estimate of the overall oxidation status for
lipids and lipid-containing foods especially in the primary phase of oxidation. The amount of free fatty
acids, also formed during lipid oxidation as a result of secondary can be assessed by titration against
potassium solution
In our daily life, a higher peroxide value at the beginning of the storage period has a negative effect on the
storage stability of the oil. For refined oils, manufacturers should aim for a peroxide value below 1. From
this value, the safety step of the free radical chain mechanism and the accumulation of hydroperoxides
can be determined. However, the peroxide value also can be indicator the quality of edible oils, because
hydroperoxides decompose during storage.
To determine the peroxide value of cooking oil (fresh palm oil and used palm oil)
Methodology:
Using a suitable flowchart, state the steps involve in this lab work.
The peroxide value (PV) is a very important characteristic of lipid quality. The assessment of
hydroperoxides provides an estimate of the overall oxidation status for lipids and lipid-containing foods
especially in the primary phase of oxidation, generally known as the induction period [ CITATION
AKa10 \l 1033 ]. In this experiment, sodium thiosulphate solution was used by using titration method and
starch solution used as an indicator during the titration. In the real world situation, cooking oil usually
been used in deep frying process and oil recycling is a common practiced in commercial and occasionally
in domestic cooking process. Basically, this type of cooking process will results to production of lipid
peroxidation product which is harmful to human health. This is due to the high temperatures in the
existence of air and moisture, which make the occurrence of oxidative degradation of amino acids and the
partial conversion of these lipids to volatile chain-scission products, non-volatile oxidized derivatives and
dimeric, polymeric or cyclic substances leading to the formation of toxic or carcinogenic compounds
[ CITATION Eru17 \l 1033 ]. Based on the result obtained in Table 1, fresh cooking oil used the least
amount of thiosulphate solution for titration which is 1.5 ml. The amount of sodium thiosulphate solution
consumed increased gradually based on the number of times the cooking oil had been consumed which is
2ml for (1x used), 2.5ml for (2x used) and 3ml for (3x used). Titration method usually been conduct for
analysing the oxidation process. In this experiment, starch solution was use as the indicator. Peroxide
value (PV) is related in measuring rancidity reactions and can be used as an indication of the quality and
stability of fats and oils [ CITATION FCE04 \l 1033 ].
Table 2 shows that the peroxide value (PV) had been computed using the formula below,
PV (meq peroxide per kg fat) = ( S x N ¿ / W x 100
Where,
S = mL of sodium thiosulphate solution used
As results shown above, the number of peroxide value increased gradually as it indicates fresh cooking oil
contained less amount of peroxide value which is 0.0015 meq/kg. While, the peroxide value increases as
the number of times the cooking oil been reused for cooking purposes. The repeated frying could cause
several oxidative and thermal reactions that result in a change of the physicochemical, nutritional and
sensory properties of the oil [ CITATION YBC00 \l 1033 ]. Generally, a fat is considered rancid when the
peroxide value is about 10 meq/Kg [ CITATION Gun96 \l 1033 ].
During the titration step, a few small errors might be the reason for inaccurate data such as inattentive
during titration which lead to overlook on the colour of solution. This will affect the accuracy data.
As conclusion, the number of peroxide value (PV) increases as the cooking oil been keep reused
for multiple times. It is because of oxidation and thermal reaction which happened during the
deep frying of oil under very high temperature. In real world, it is best possible to avoid from
reusing fresh cooking oil as it will affect our health. Consuming the fresh cooking oil for every
single deep frying session is the best solution maintaining low peroxide value (PV).
References :
a) Generation of hydroperoxides
R-HO2 ROOH
b) Generation of Iodine
KI CH3COOH HI CH3COO-K