RCD Pro
RCD Pro
V. Calculate the Ru
Ru= Mu 6.6103
ɸbd^2
V. Calculate the Ru
Ru= Mu 3.3052
ɸbd^2
V. Calculate the Ru
Ru= Mu 2.6827
ɸbd^2
V. Calculate the Ru
Ru= Mu 1.3414
ɸbd^2
V. Calculate the Ru
Ru= Mu 0.3573
ɸbd^2
pmax = 0.028375
pmin < p < max
therefore, use p = 0.009051
b. 3(h) 375 mm
Therefore,Use 12mm Ø Temp. Bar @ Spacing of 230 mmO.C.
b. 3 (h) 375 mm
DESIGN OF ONE - WAY SLAB
ROOF DECK LEVEL
c. 450 mm
Therefore,Use 10mm Ø Temp. Bar @ Spacing of 165 mmO.C.
DESIGN OF ONE - WAY SLAB
ROOF DECK LEVEL
ng of 60mm O.C.
acing of 40mmO.C.
DESIGN OF ONE - WAY SLAB
ROOF DECK LEVEL
ng of 130mm O.C.
acing of 90mmO.C.
DESIGN OF ONE - WAY SLAB
ROOF DECK LEVEL
ng of 55mm O.C.
acing of 40mmO.C.
DESIGN OF ONE - WAY SLAB
ROOF DECK LEVEL
ng of 125mm O.C.
acing of 85mmO.C.
DESIGN OF TWO-WAY SLAB
3RD FLOOR LEVEL
GIVEN:
Live Load = 1.9 KPa h= 125 mm VIII. Compute the required main bar spacing
f’c = 21 MPa As=pbd 674.6701 mm^2
fy = 275 MPa Ab= (π(Øbar)^2) /4 114.562 mm^2
ɣ of concrete 23.54 KN/m^3
Ls = 7.5 m S= Ab x 1000
Lb = 8m As
b = 1000 mm
Bar Ø = 12 mm
Temp. Bar Ø = 10 mm Discontinuous End
d' = 25 mm d= h'-d'-0.5Øbar = 94 mm
I. Calculate the service Loads
Considering 1 m strip : b = 1000mm IX. Calculate the Ru
DL= ɣ of concrete x h x b = 2.9425 Kn/m Ru=Mu/Øbd^2 0.2967
LL = 1. 9 Kpa x b = 1.9 kn/m
X. Calculate ρ, ρmin, and ρmax
II. Calculate for the factored Load ρ =(0.85 f'c/fy) [1-√(1-2Ru/0.85f'c)]
Wu= 1.2 DL + 1.6 LL 6.571 Kn/m p= 0.00409
pmin= 1.4
RATIO= S / L 0.75 fy
pmin= 0.00509
Negative Moment at Continuous Edge ( Case 4) pmin > p Therefore use pmin= 0.00509
a. Consider the Short Direction , L= 7.5 m
Cs= 0.087 XI. Compute the Required main bar spacing
Ms= CsWuLs^2 32.157 Kn/m As=pbd 674.6701 mm^2
b. Consider the Long Direction, L=8 m Ab= (π(Øbar)^2) /4 114.562 mm^2
Cb= 0.034
Ms= CbWuLs^2 14.2985 Kn/m S= Ab x 1000 231.23 mm
As say 230 mm
Positive Moment due to Dead Load ( Case 4)
a. Consider the Short Direction, L= 7.5 m ALONG SHORT DIRECTION ( MIDSPAN)
Cs= 0.056
Ms= CsWuLs^2 20.6986 Kn/m d= h'-d'-0.5Øbar = 94 mm
b. Consider the Long Direction, L=8 m
Cb= 0.015 XII. Calculate the Ru
Ms= CbWuLs^2 6.3082 Kn/m Ru=Mu/Øbd^2 1.6879
Positive Moment due to Live Load ( Case 4) XIII. Calculate p, pmin, pmax
a. Consider the short direction, L= 7.5 m ρ =(0.85 f'c/fy) [1-√(1-2Ru/0.85f'c)]
Cs= 0.096 p= 0.00756
Ms= CsWuLs^2 35.4834 kn/m pmin= 1.4
b. Consider the Long Direction, L= 8 m fy
Cb= 0.019 pmin= 0.00509
Ms= CbWuLs^2 7.99033 kn/m pmin < p okey use p = 0.00756
Negative Moment at Discontinuous Edges XIV. Compute the Required main bar spacing
Positive
MED's
Moment =
As=pbd 768.989 mm^2
8.3453
DESIGN OF TWO-WAY SLAB
3RD FLOOR LEVEL
Ab= (π(Øbar)^2) /4 114.562 mm^2
ALONG LONG DIRECTION MIDSPAN
d= h'-d'-0.5Øbar = 94 mm S= Ab/As x 1000 245.98mm
say 240 mm
III. Calculate Ru
Ru = Mu 0.9658 Continous End
ɸbd^2 d= h'-d'-0.5Øbar = 94 mm
S= Ab x 1000 231.23 mm
As say 230 mm.
GIVEN:
Live Load= 1.9 kpa
Span= 7.5 m
Height= 125mm
b= 1000 m
Bar Ø = 12 mm
Temp. Bar Ø= 10 mm
f'c = 21 Mpa
fy = 275 Mpa
ɣ of concrete = 23.54 kn/m^3
d' = 25 mm
Ls= 4m
Lb = 7.5
III. Calculate Ru
Ru=Mu/Øbd^2 0.2435
Discontinous End
DESIGN OF TWO-WAY SLAB
3RD FLOOR LEVEL
d = h - d' - 0.5Øbar 94 mm
RATIO = S/ L 0.75
d = h - d' - 0.5Øbar 94 mm
Continous End
d = h - d' - 0.5Øbar 94 mm
Discontinous End
d = h - d' - 0.5Øbar 94 mm
Continous End
d = h - d' - 0.5Øbar 94 mm
Discontinous End
d = h - d' - 0.5Øbar 94 mm
say 230 mm
d = h - d' - 0.5Øbar 94 mm
Continuous End
d = h - d' - 0.5Øbar 94 mm
Discontinous End
d = h - d' - 0.5Øbar 94 mm
d = h - d' - 0.5Øbar 94 mm
Discontinous End
d = h - d' - 0.5Øbar 94 mm
GIVEN:
Live Load = 1.9 kpa
Span= 8m
Height = 125 mm
b= 1000 mm
Bar Ø = 12 mm
Temp. Bar Ø = 10 mm
f'c = 21 Mpa
f'y = 275 Mpa
ɣ of concrete = 23. 54 Mpa
d' = 25 mm
Ls = 4m
Lb= 8m
III. Calculate Ru
Ru=Mu/Øbd^2 0.7854
Continuous End
d = h - d' - 0.5Øbar 94 mm
VI. Calculate Ru
Ru=Mu/Øbd^2 0.7433
Discontinous End
d = h - d' - 0.5Øbar 94 mm
IX. Calculate Ru
Ru=Mu/Øbd^2 0.3382
XII. Calculate Ru
Ru=Mu/Øbd^2 1.45567
Continous Edge
d = h - d' - 0.5Øbar 94 mm
XV. Calculate Ru
Ru=Mu/Øbd^2 0.879
DESIGN OF TWO-WAY SLAB
3RD FLOOR LEVEL
XVI. Calculate p, pmin, pmax
ρ =(0.85 f'c/fy) [1-√(1-2Ru/0.85f'c)]
p= 0.0023
pmin= 1.4/fy
pmin= 0.00509
pmin > p therefore use pmin = 0.00509
XVIII. Calculate Ru
Ru=Mu/Øbd^2 0.7856
XX.
Compute the Required Main bar Spacing
As=pbd 674.6701 mm^2
Ab= (π(Øbar)^2) /4 114.562 mm^2
S= Ab/As x 1000 275.89 mm
say 200 mm
DESIGN OF TWO-WAY SLAB
3RD FLOOR LEVEL
114.562 mm^2
231.23 mm
say 230 mm
114.562 mm^2
say 230 mm
DESIGN OF TWO-WAY SLAB
3RD FLOOR LEVEL
114.562 mm^2
1-2Ru/.85f'c)]
674.6701 mm^2
114.562 mm^2
say 230 mm
DESIGN OF TWO-WAY SLAB
3RD FLOOR LEVEL
x 1000 231.23 mm
say 230 mm.
XII. Calculate Ru
Ru=Mu/Øbd^2 0.8521
Continuous End
d = h - d' - 0.5Øbar 94 mm
Calculate the Ru
Ru=Mu/Øbd^2 0.5217
Discontinou End
d = h - d' - 0.5Øbar 94 mm
Calculate the Ru
Ru=Mu/Øbd^2 0.3484
III. Calculate for the factored load XI. Determine the Number of Bars
Wu = 1.2DL + 1.6LL 3.26 KN/m Use Øbar = 16 mm
Ab = π(Øbar)^2 201.06
IV. Calculate the ultimate moment 4
Mu = Wu(L)^2 26.06 KN - m N= As 4.7
8 Ab say 5 bars
XII. Calculate the Actual Area
V. Calculate the required steel ratio ρ As = N(Ab) 945.82
Try ρ = .5ρb
ρ = (.50)(.85)(f'c)(β)(600) 0.01891636 XIII. Check for Nominal Moment Capacity (Mn)
fy(600+fy) a = βC 106.25
ρ= As 0.01892
ρmin = 1.4 0.00509091 bd
fy Mn = .85(f'c)(a)(b)(d-.5a) 74677148
ρmin < ρ okey! 74.6771484
Use ρ = 0.01891636
Mn = As(fy)(d-.5a) 51207187.5
VI. Calculate ω, Ru, b and d 51.2071875
ω= ρfy 0.24771
f'c XIV. Calculate Vu and Vc
Vu = Wu(.5L-d) 12.216
Ru = ωf'c[1 - .59ω] 4.442 Mpa
BEAM 2.A (SINGLY REINFORCE) Mu = ɸMn = ɸRubd^2
"Both End Continuous" Mu 10819889
bd^2 =
GIVEN: ɸRu
DESIGN OF ROOF DECK BEAM
SINGLY REINFORCED
III. Calculate for the factored load XI. Determine the Number of Bars
Wu = 1.2DL + 1.6LL 12.30 KN/m Use Øbar = 16 mm
Ab = π(Øbar)^2 201.06
IV. Calculate the ultimate moment 4
Mu = Wu(L)^2 43.25 KN - m N= As 6.6
16 Ab say 7 bars
XII. Calculate the Actual Area
V. Calculate the required steel ratio ρ As = N(Ab) 1324.15
Try ρ = .5ρb
ρ = (.50)(.85)(f'c)(β)(600) 0.01891636 XIII. Check for Nominal Moment Capacity (Mn)
fy(600+fy) a = βC 148.75
ρ= As 0.01892
ρmin = 1.4 0.00509091 bd
fy Mn = .85(f'c)(a)(b)(d-.5a) 146367211
ρmin < ρ okey! 146.367211
Use ρ = 0.01891636
Mn = As(fy)(d-.5a) 100366088
VI. Calculate ω, Ru, b and d 100.366088
ω= ρfy 0.24771
f'c XIV. Calculate Vu and Vc
Vu = Wu(.5L-d) 41.830
Ru = ωf'c[1 - .59ω] 4.442 Mpa
BEAM 3.B (SINGLY REINFORCE) Mu = ɸMn = ɸRubd^2
"One End Continuous" Mu 6272399.29
bd^2 =
GIVEN: ɸRu
Live Load = 1.9 Kpa Try d = 1.5b
Span = 4m b(1.5b)^2 = 6272399.29
f'c = 21 Mpa b^3 = 2787733
DESIGN OF ROOF DECK BEAM
SINGLY REINFORCED
III. Calculate for the factored load XI. Determine the Number of Bars
Wu = 1.2DL + 1.6LL 12.54 KN/m Use Øbar = 16 mm
Ab = π(Øbar)^2 201.06
IV. Calculate the ultimate moment 4
Mu = Wu(L)^2 25.07 KN - m N= As 4.7
8 Ab say 5 bars
XII. Calculate the Actual Area
V. Calculate the required steel ratio ρ As = N(Ab) 945.82
Try ρ = .5ρb
ρ = (.50)(.85)(f'c)(β)(600) 0.01891636 XIII. Check for Nominal Moment Capacity (Mn)
fy(600+fy) a = βC 106.25
ρ= As 0.01892
ρmin = 1.4 0.00509091 bd
fy Mn = .85(f'c)(a)(b)(d-.5a) 74677148
ρmin < ρ okey! 74.6771484
Use ρ = 0.01891636
Mn = As(fy)(d-.5a) 51207187.5
VI. Calculate ω, Ru, b and d 51.2071875
ω= ρfy 0.24771
f'c XIV. Calculate Vu and Vc
Vu = Wu(.5L-d) 21.940
Ru = ωf'c[1 - .59ω] 4.442 Mpa
BEAM 4.B (SINGLY REINFORCE) Mu = ɸMn = ɸRubd^2
"Both End Continuous" Mu 7840499.11
bd^2 =
GIVEN: ɸRu
Live Load = 1.9 Kpa Try d = 1.5b
Span = 5m b(1.5b)^2 = 7840499.11
f'c = 21 Mpa b^3 = 3484666.27
fy = 275 MPa b= 151.607399
ɣ of concrete = 23.54 KN/m3 say b = 200 0.2 m
h= 125 mm bd^2 = 7840499.11
DESIGN OF ROOF DECK BEAM
SINGLY REINFORCED
III. Calculate for the factored load XI. Determine the Number of Bars
Wu = 1.2DL + 1.6LL 20.06 KN/m Use Øbar = 16 mm
Ab = π(Øbar)^2 201.06
IV. Calculate the ultimate moment 4
Mu = Wu(L)^2 31.34 KN - m N= As 4.7
16 Ab say 5 bars
XII. Calculate the Actual Area
V. Calculate the required steel ratio ρ As = N(Ab) 945.82
Try ρ = .5ρb
ρ = (.50)(.85)(f'c)(β)(600) 0.01891636 XIII. Check for Nominal Moment Capacity (Mn)
fy(600+fy) a = βC 106.25
ρ= As 0.01892
ρmin = 1.4 0.00509091 bd
fy Mn = .85(f'c)(a)(b)(d-.5a) 74677148
ρmin < ρ okey! 74.6771484
Use ρ = 0.01891636
Mn = As(fy)(d-.5a) 51207187.5
VI. Calculate ω, Ru, b and d 51.2071875
ω= ρfy 0.24771
f'c XIV. Calculate Vu and Vc
Vu = Wu(.5L-d) 45.134
Ru = ωf'c[1 - .59ω] 4.442 Mpa
DESIGN OF ROOF DECK BEAM
SINGLY REINFORCED
KN/m <
KN/m
mm <
mm
mm2
bars
say 5 bars
mm2
mm
KN - m
KN - m
KN
KN/m <
KN/m
mm <
mm
mm2
bars
say 7 bars
mm2
mm
KN - m
KN - m
KN
KN/m <
KN/m
mm <
mm
mm2
bars
say 5 bars
mm2
mm
KN - m
KN - m
KN
KN/m <
KN/m
mm <
mm
mm2
bars
say 5 bars
mm2
mm
KN - m
KN - m
KN
DESIGN OF DOUBLY REINFORCED BEAM3RD FLOOR LEVEL
when Vs ˂ 1/3(f'c)^(1/2)(bw)(d),
25 mm ф RSB
ompression side Smax = d/2 or 600mm
when Vs ˃ 1/3(f'c)^(1/2)(bw)(d),
KN d/2 = 125 mm
Say S = 125mm
when Vs ˂ 1/3(f'c)^(1/2)(bw)(d),
25 mm ф RSB
ompression side Smax = d/2 or 600mm
when Vs ˃ 1/3(f'c)^(1/2)(bw)(d),
KN d/2 = 200 mm
Say S = 200mm
when Vs ˂ 1/3(f'c)^(1/2)(bw)(d),
25 mm ф RSB
ompression side Smax = d/2 or 600mm
when Vs ˃ 1/3(f'c)^(1/2)(bw)(d),
KN d/2 = 150 mm
Say S = 150mm
when Vs ˂ 1/3(f'c)^(1/2)(bw)(d),
25 mm ф RSB
ompression side Smax = d/2 or 600mm
when Vs ˃ 1/3(f'c)^(1/2)(bw)(d),
KN d/2 = 175 mm
Say S = 175mm
DESIGN OF DOUBLY REINFORCED BEAM3RD FLOOR LEVEL
mm
mm
mm
mm
DESIGN OF DOUBLY REINFORCED BEAM3RD FLOOR LEVEL
mm
mm
mm
mm
DESIGN OF DOUBLY REINFORCED BEAM3RD FLOOR LEVEL
mm
mm
mm
mm
II. Assume Beam wt. = 25 % (DL + LL) ρ = 0.00586995 < 0.028375 OK!!!!
Calculate the Inherent Shear Strenght provided therefore Smax = d/2 or 600 mm
provided by the concrete, Vc
d/2 = 150 mm
Vc = 1/6(√f'c)(bw)(d) 57.2821962 KN
Say S = 150 mm
фVc = 48.6898668
II. Assume Beam wt. = 25 % (DL + LL) ρ = 0.00503138 < 0.028375 OK!!!!
Calculate the Inherent Shear Strenght provided therefore Smax = d/2 or 600 mm
provided by the concrete, Vc
d/2 = 175 mm
Vc = 1/6(√f'c)(bw)(d) 66.8292289 KN
Say S = 200 mm
фVc = 56.8048446
II. Assume Beam wt. = 25 % (DL + LL) ρ = 0.00586995 < 0.028375 OK!!!!
Calculate the Inherent Shear Strenght provided therefore Smax = d/2 or 600 mm
provided by the concrete, Vc
d/2 = 150 mm
Vc = 1/6(√f'c)(bw)(d) 45.8257569 KN
Say S = 150 mm
фVc = 38.9518934
II. Assume Beam wt. = 25 % (DL + LL) ρ = 0.00586995 < 0.028375 OK!!!!
Calculate the Inherent Shear Strenght provided therefore Smax = d/2 or 600 mm
provided by the concrete, Vc
d/2 = 150 mm
Vc = 1/6(√f'c)(bw)(d) 45.8257569 KN
Say S = 150 mm
фVc = 38.9518934
n Requirements
DESIGN OF T - BEAMS
2ND FLOOR LEVEL
DESIGN OF T - BEAMS
2ND FLOOR LEVEL
n Requirements
DESIGN OF T - BEAMS
2ND FLOOR LEVEL
n Requirements
DESIGN OF T - BEAMS
2ND FLOOR LEVEL
n Requirements
DESIGN OF TWO WAY SLAB
(Direct Design Method) 2nd Floor
M= Positive Moment
M = 42.77189 KN-m
M = 0.57(Mo) 257.52527 KN-m
Beam = 85%(+Column Strip)
36.35611 KN-m Column Strip
Slab = 15%(+Column Strip)
6.415784 KN-m
M = 12.2478761 KN-m
Middle Strip
Beam = 85%(+Column Strip)
M = .2116% positive moment 10.4106947 KN-m
114.7962 KN-m Slab = 15%(+Column Strip)
1.83718142 KN-m
V. Consider the Moment @ Short Direction
Middle Strip
δs = 0.27
L2/L1 = 2 M = .5244% Positive moment
135.046252 KN-m
Ln = 3.8 m
Use 16 mm ф RSB
Ab = 201.0619 mm
A&C B
Across D Across E Across F Across D Across E Across F
Mu 1.128094 82.923137 1.12809385 0.918590708 135.046252 0.91859071
b 1000 1000 1000 2000 2000 2000
d 122 122 122 122 122 122
Ru 0.084214 6.1903265 0.08421376 0.034287031 5.0406944 0.03428703
ρ 0.000307 0.0289793 0.00030696 0.0001248 0.02208796 0.0001248
Used ρ 0.0051 0.0289793 0.0051 0.0051 0.02208796 0.0051
As 622.2 3535.48 622.2 1244.4 5389.4628 1244.4
N 3.094569 17.584035 3.09456892 6.189137849 26.8049889 6.18913785
S 323.1468 56.869769 323.146785 161.5733927 37.3064881 161.573393
Used S 320 35 320 160 25 160
Position Top Bottom Top Top Bottom Top
Use 16 mm ф RSB
Ab = 201.0619 mm
h= 100 mm d= 134 mm
δs = 0.27
δb = 0.343 VI. Calculate the Ultimate Factored Load, Wu
bw = 200 mm
Ln = 7300 mm Wu = 1.2Wdl + 1.6Wll
d' = 20 mm Wu = 31.288 KN/m^2
Wdl = 23.54 KN/m
Wll = 1.9 KN/m Assume 1 m Strip
Wu = 31.288 KN/m
I. Calculate the slab thickness
VII. Check for the Depth of Shear,
h= (Ln(800+.73f'c)/36000+9000B Calculate the Value of Y
(min. valua.)
h = 4.357857 mm Y= 1.266 m
M= Positive Moment
M = 37.46407 KN-m
M = 0.57(Mo) 241.429941 KN-m
Beam = 85%(+Column Strip)
31.84446 KN-m Column Strip
Slab = 15%(+Column Strip)
5.619611 KN-m
M = 11.4823839 KN-m
Middle Strip
Beam = 85%(+Column Strip)
M = .2116% positive moment 9.76002627 KN-m
100.5505 KN-m Slab = 15%(+Column Strip)
1.72235758 KN-m
V. Consider the Moment @ Short Direction
Middle Strip
δs = 0.27
L2/L1 = 1.875 M = .5244% Positive moment
126.605861 KN-m
Ln = 3.8 m
Use 16 mm ф RSB
Ab = 201.0619 mm
A&C B
Across D Across E Across F Across D Across E Across F
Mu 1.057588 77.740441 1.05758799 0.861178789 126.605861 0.86117879
b 1000 1000 1000 2000 2000 2000
d 122 122 122 122 122 122
Ru 0.07895 5.8034311 0.0789504 0.032144092 4.725651 0.03214409
ρ 0.000288 0.0265218 0.00028773 0.000116993 0.02038527 0.00011699
Used ρ 0.0051 0.0265218 0.0051 0.0051 0.02038527 0.0051
As 622.2 3235.6551 622.2 1244.4 4974.00658 1244.4
N 3.094569 16.092828 3.09456892 6.189137849 24.7386792 6.18913785
S 323.1468 62.139481 323.146785 161.5733927 40.4225299 161.573393
Used S 320 35 320 160 25 160
Position Top Bottom Top Top Bottom Top
Use 16 mm ф RSB
Ab = 201.0619 mm
DESIGN OF TWO WAY SLAB
(Direct Design Method) 2nd Floor
- 0.5
0 75
0.256 78.84
1 90
- 2
0 75
0.91467 47.5599
1 45
Value of δ
δs = 0.27
δb = 0.343
DESIGN OF TWO WAY SLAB
(Direct Design Method) 2nd Floor
0.83
0 75
0.256 78.84
1 90
1.2
0 75
DESIGN OF TWO WAY SLAB
(Direct Design Method) 2nd Floor
0.91467 47.5599
1 45
Value of δ
@ long Span
δ = Ecb x I of beam/Ecs x I f slab
δs = 0.27
δb = 0.343
DESIGN OF COLUMN
b = 742.292692 mm
N = Ast/Ab = 26.0761505
= 0.00306794
GIVEN:
Total Reactions = 3547.35 KN
DL = 125.68 KN
Dimension = 250 mm x 250 mm
qa = 230 Kpa
ɣ of concrete = 23.5 Kn/cu.m
ɣ of Soil = 15.6 Kn/cu.m
fy = 275 Mpa
fc = 21 Mpa
main bar Ø = 25 mm
d' = 75 mm
Base of Footing = 4m
NOTE:
THE FIRST TASK IN THE DESIGN OF FOOTING IS THE DETERMINATION OF ITS DEPTH. THIS
REQUIRES SEVERAL CYCLE OF TRIAL AND ERROR PROCEDURE BECAUSE ITS VALUE AFFECTS THE EFFECTIVE
SOIL BEARING CAPACITY. THERE ARE SEVERAL RULES OF THUMB USED IN MAKING INITIAL THICKNES ESTIMATES, SUCH
AS 20% OF FOOTING WIDTH PLUS 75 MM.
A= 5.679045 m^2
L= 2.786754 m
say 3 m or 3000 mm
Therefore : Footing Dimension 3mx3m
Depth of footing
qu= (factored Load )/(Area of Footing )
qu= 624.64 Kpa
qu= 0.62464 Mpa
Vc=1/6 (f'c)bd
Vc=1/6 √(21)3000(d)
Vc= 2291.29 d
Vc=фVc
1872(837.5- d )= (0.85)(2291.287847)(d)
Solving For d:
d= 410.4624 mm
say d= 500 mm
Vc=1/3√(fc)bd
Vc=1/3√(21)(3)d
Vc=4.58257 d
Vc=фVc
(0.624)(936000-500d-d^2)=(0.85)(4.58257)(d)
Solving for d:
d= 746.91 mm
say d= 800 mm
Used d= 800 mm
p=0.85(f'c)/fx -√1-2Ru/0.85(f'c)
p= 0.005679
pmin= 0.0051
pmax= 0.75 pb
pmax= 0.012777
Used p= 0.00568
As= pbd 5112 mm^2
N= As/Ab 16.89078
Say 17- 25 mm ф RSB
NOTE:
THE FIRST TASK IN THE DESIGN OF FOOTING IS THE DETERMINATION OF ITS DEPTH.THIS REQUIRES
SEVERAL CYCLES OF TRIAL AND ERROR PROCEDURE BECAUSE ITS VALUE AFFECTS THE EFFECTIVE SOIL
BEARING CAPACITY. THERE ARE SEVERAL RULES OF THUMB USED FOR MAKING INITIAL THICKNESS ESTIMATES,
SUCH AS 20% OF FOOTING WIDTH PLUS 75 MM.
A= 650.87/201.86
A= 3.22336 m^2
L= 2.4567098 m
Say 3 m or 3000 mm
Therefore Footing Dimension= 3m x3m
Depth Of Footing
qu= (Factored Load)/(Area of Footing)
qu= 1.2 DL + 1.6 LL/L
1.2( 650.87)+ 1.6( 590)/3(3)
qu= 191.67155 Kpa
qu= 0.19167155 Mpa
Vu= 0.19167155(3000)(800-d)
Vu= 575.015(800-d)
Vc = 1/6(√f'c)(b)(d)
Vc= 2291.29 d Vc = 1/3(√f'c)(b)(d)
Vu= фVc
575.015(800-d)= (0.85)(2291.29)( d)
Solving For d:
d= 182.3554 mm
say 200 mm
Vc= 1/3(√f'c)(b)(d)
Vc= 1/3(√21)(200)(d)
Vc= 3.05505 d
Vu= фVc
0.19167155(600000-800d-d^2) = (0.85)(3.05505)(d)
Solving for d:
d= 468.13 mm
say d= 500 mm
p=0.85(f'c)/fx -√1-2Ru/0.85(f'c)
p= 0.00609434
pmin= 1.4/fy
pmin= 0.005091
Use p: 0.00609434
As= pbd
0.00609434*3000*300
As= 5484.906 mm^2
Number of 20 - mm bars:
3.14/4(20)^2(N)= 5484.906
N= 17.4589
Say 18 mm
Say 18- 20 mm ф RSB