Download as pdf or txt
Download as pdf or txt
You are on page 1of 192

Industrial Training Project Report

On
“Coal - Fired Steam Power Plants”

National Thermal Power Corporation SIMHADRI (Visakhapatnam)

(Submitted towards completion of industrial training at NTPC SIMHADRI)

Under the guidance of: Submitted by:

Shri B.Venkata Rao, Uppu Ashish,

DGM, Ash Handling Plant, B.Tech, Mechanical Engg.

NTPC SIMHADRI, (4th sem),

Visakhapatnam. GITAM University,

Visakhapatnam.

1
TRAINING SCHEDULE

DEPARTMENT PERIOD
11.05.2015
BOILER MAINTAINANCE to
16.05.2015
18.05.2015
TURBINE MAINTAINANCE to
23.05.2015
25.05.2015
OFFSITE MAINTAINANCE to
30.05.2015
01.06.2015
ASH HANDLING PLANT to
09.06.2015

2
CERTIFICATE

This is to certify that UPPU ASHISH, a student of 2012-2016 Batch


of B.Tech,Mechanical Engineering in 4th Year of GITAM University,
Visakhapatnam has successfully completed his industrial training at
NTPC Simhadri, Visakhapatnam for four weeks from 7th May to 9th
June 2015. He has completed the whole training as per the training
report submitted by him.

HR Manager
NTPC Simhadri,
Visakhapatnam

3
Acknowledgment
“It is not possible to prepare a project report without the assistance &
encouragement of other people. This one is certainly no exception.”

On the very outset of this report, I would like to extend my sincere &
heartfelt obligation towards all the personages who have helped me in
this endeavor. Without their active guidance, help, cooperation &
encouragement, I would not have made headway in the industrial
training

I am ineffably indebted to Mr. K.N. Reddy, AGM (MM-BMD); Mr.


D.Shravan, Dy. Manager (BMD-PP); Mr. Piyush Kanwar, Dy. Manager
(BMD-Mills); Mr. Balaji, Dy. Manager (BMD-RM); Mr. T.Prem Das, AGM
(MM-TMD & OS); Mr. Shridhar, Dy. Manager (MM-TMD) for
conscientious and encouragement to accomplish this assignment.

I am extremely thankful and pay my gratitude to my guide Mr. B.Venkata


Rao for his valuable guidance and support on completion of this project
in its presently.

I extend my gratitude to NTPC Ltd Simhadri and HR-EDC Dept. of NTPC


Ltd Simhadri for giving me this opportunity.

I also acknowledge with a deep sense of reverence, my gratitude


towards my parents, who has always supported me morally as well as
economically.

Any omission in this brief acknowledgement does not mean lack of


gratitude.

Thanking You

Ashish Uppu
4
TABLE OF CONTENTS

1. About NTPC……………………………………………… 6
2. About NTPC SIMHADRI……………………………. 14
3. NTPC power stations in India…………………… 18
4.Principal and Operation of a Thermal Power
Plant…………………………………………………………. 19
5.Principal components of a 500MW Thermal
Power Plant………………………………………………. 29
6.The Layout of NTPC Simhadri……………………. 45
7.Boiler and its auxiliaries……………………………. 48
8.The Steam Turbine Theory……………………… 118
9. Turbine and its auxiliaries……………………… 128
10. DM treatment
plant……………………………………………………….. 161
11. Cooling Towers…………………………………. 169
12. Circulating Water System…………………. 174
13. Principal components of CWS………….. 178
14. Ash Handling System……………………….. 183
15. Ways to increase the thermal efficiency of
power plants………………………………………….. 187
16. Losses during operation & maintenance of
a power plant…………………………………………. 190
5
About NTPC

NTPC Limited is the largest thermal power generating company of


India, Public Sector Company. It was incorporated in the year 1975 to
accelerate power development in the country as a wholly owned
company of the Government of India. NTPC is emerging as a diversified
power major with presence in the entire value chain of the power
generation business. Apart from power generation, which is the mainstay
of the company, NTPC has already ventured into consultancy, power
trading, ash utilization and coal mining. NTPC ranked 341st in the ‘2010,
Forbes Global 2000’ ranking of the World’s biggest companies. NTPC
became a Maharatna company in May, 2010, one of the only four
companies to be awarded this status.
Within a span of 31 years, NTPC has emerged as a truly national
power company, with power generating facilities in all the major regions of the
country. NTPC's core business is engineering, construction and operation
of power generating plants and providing consultancy to power utilities in
India and abroad.

The total installed capacity of the company is 31134 MW (including JVs)


with 15coal based and 7 gas based stations, located across the country.
In addition under JVs, 3 stations are coal based & another station uses

6
naphtha/LNG as fuel. By 2017, the power generation portfolio is
expected to have a diversified fuel mix with coal based capacity of
around 53000 MW, 10000 MW through gas, 9000 MW through Hydro
generation, about 2000 MW from nuclear sources and around 1000MW
from Renewable Energy Sources (RES). NTPC has adopted a multi-
pronged growth strategy which includes capacity addition through green
field projects, expansion of existing stations, joint ventures, subsidiaries
and takeover of stations.

NTPC has been operating its plants at high efficiency levels. Although the
company has 18.79% of the total national capacity it contributes 28.60%
of total power generation due to its focus on high efficiency. NTPC’s
share at 31 Mar 2001of the total installed capacity of the country was
24.51% and it generated 29.68%of the power of the country in 2008-09. Every
fourth home in India is lit by NTPC.170.88BU of electricity was produced by its
stations in the financial year 2005-2006. The Net Profit after Tax on March
31, 2006 was INR 58,202 million. The Net Profit after Tax for the quarter
ended June 30, 2006 was INR 15528 million, which is 18.65% more than
for the same quarter in the previous financial year. 2005). NTPC is as
second best utility in the world.

In October 2004, NTPC launched its Initial Public Offering (IPO)


consisting of 5.25% as fresh issue and 5.25% as offer for sale by
Government of India. NTPC thus became a listed company in November
2004 with the Government holding 89.5% of the equity share capital. In
February 2010, the Shareholding of Government of India was reduced
from 89.5% to 84.5% through Further Public Offer and the balance 10.5%
is held by FIIs, Domestic Banks, Public and others.

7
NTPC Limited
Type Public

Founded 1975

Headquarters Delhi, India

Key people R S Sharma, Chairman & Managing Director

Industry Electricity generation

Products Electricity

Revenue INR 416.37 billion (2008)

Net income INR 70.47 billion (2008)

Employees 23867 (2006)

Website http://www.ntpc.co.in

8
Strategies of NTPC

Technological Initiatives

 Introduction of steam generators (boilers) of the size of 800 MW.


 Integrated Gasification Combined Cycle (IGCC) Technology.
 Launch of Energy Technology Centre -A new initiative for
development of technologies with focus on fundamental R&D.
 The company sets aside up to 0.5% of the profits for R&D.
 Roadmap developed for adopting μClean Development.
 Mechanism to help get / earn μCertified Emission Reduction.

9
Corporate Social Responsibility

 As a responsible corporate citizen NTPC has taken up number of


CSR initiatives.
 NTPC Foundation formed to address Social issues at national
level
 NTPC has framed Corporate Social Responsibility Guidelines
committing up to 0.5% of net profit annually for Community
Welfare.
 The welfare of project affected persons and the local population
around NTPC projects are taken care of through well drawn
Rehabilitation and Resettlement policies.
 The company has also taken up distributed generation for remote
rural areas

Partnering government in various initiatives

 Consultant role to modernize and improvise several plants across


the country.
 Disseminate technologies to other players in the sector.
 Consultant role Partnership in Excellence Programme for
improvement of PLF of 15 Power Stations of SEBs.
 Rural Electrification work under Rajiv Gandhi Garmin Vidyutikaran.

Environment management

 All stations of NTPC are ISO 14001 certified.


 Various groups to care of environmental issues.
 The Environment Management Group.
 Ash tilization Division.
 Afforestation Group.
 Centre for Power Efficiency & Environment Protection.
 Group on Clean Development Mechanism.

10
 NTPC is the second largest owner of trees in the country after
the Forest department.

Vision
“To be the world’s largest and best power producer, powering India’s
growth.”

Mission
“Develop and provide reliable power, related products and services
at competitive prices, integrating multiple energy sources with
innovative and eco-friendly technologies and contribute to society.”

Core Values – BE COMMITTED

B Business ethics
E Environmentally and Economically Sustainable
C Customer Focus
O Organizational and Professional Pride
M Mutual Respect and Trust
M Motivating Self and Others
I Innovation and Speed
T Total Quality for Excellence
T Transparent and Respected Organization
E Enterprising
D Devoted

11
Journey of NTPC

12
A Qualitative study of the Company

13
About NTPC Simhadri
Simhadri Super Thermal Power Plant is a coal-fired power plant
located in the Visakhapatnam district of the Indian state of Andhra
Pradesh. The power plant is one of the coal fired power plants of NTPC,
a Government of India enterprise. The coal for the power plant is
sourced from Kalinga Block of Talcher Coal fields in Odisha. Power
generated by units 1 and 2, making up for 1,000 MW, is dedicated to
power distribution companies owned by the Government of Andhra
Pradesh. The remainder 1,000 MW, generated by units 3 and 4, is
allocated to the states of Odisha, Tamil Nadu, and Karnataka. Their
shares are decided arbitrarily, with unsold power being sold to Andhra
Pradesh.
NTPC Simhadri is a modern coal-fired power plant, and is a combination
of four independent generation units, with common water and fuel
sources, and common ash ponds. Each of the four units has a
nameplate capacity of 500 MW. Units 1 and 2 were built in the first
phase of development, and were commissioned in February 2002 and

14
August 2004, respectively, to meet urgent needs of power in the largely
agrarian Coastal Andhra and North-Coastal Andhra regions. Units 3 and
4 were built in the second phase, and commissioned in March 2011 and
March 2012, respectively. Since the operator of this plant is a
Government of India enterprise, and since the plant was built with
central government funds, power generated by units 3 and 4 are sold to
distribution companies based in neighboring states of Odisha, Tamil
Nadu, and Karnataka, over the National Grid, as power stocks. The
allocations are decided between NTPC and the three states' discoms.
Unsold units are offered to discoms of Andhra Pradesh for purchase at
market prices.
Coal for NTPC Simhadri is sourced from Talcher Coal Fields, Odisha,
and transported by East Coast Railway (ECoR), over the Kolkata-
Chennai trunk line, with a spur heading towards the plant at Duvvada.
NTPC Simhadri uses fresh water sourced from the Yeluru Canal as
working fluid (steam which turns the turbines). For cooling, however, the
plant uses seawater pumped in from the Bay of Bengal. Seawater, with
its salt content, is unfit to be used as working fluid, without desalination.

15
PROJECT PROFILE

Approved Capacity 2000 MW (4 X 500 MW)

Location Paravada Mandal, Visakhapatnam, AP

Source of Finance JBIC Loan and Internal Resources

Fuel Source Mahanadi Coal Fields, Talcher

Fuel Requirement 5.04 Million Tons of Coal per annum

Mode of Transportation Rail

DM Water Source Water from Yelluru Canal

Sweet Water Requirement 600 m3 / hr

Cooling Water Source Sea Water from Bay of Bengal

Sea Water Requirement 9100 m3 / hr

Main Contractor M/s BHEL

Power Evacuation AP TRANSCO (Via Kalpaka)

Beneficiary State Andhra Pradesh

16
Salient Features of NTPC Simhadri

• First Coastal Based Coal fired thermal Power Project of NTPC

• Biggest Sea Water Intake-Well in India (For Drawing Sea Water


from Bay of Bengal)

• Use of Sea Water for Condenser Cooling and Ash Disposal

• Asia’s Tallest Natural Cooling Towers (165 m), 6th in the


World

• Use of Fly-Ash Bricks in the Construction of all Buildings

• Coal Based Project of NTPC Whose Entire Power is allocated to


Home State (AP)

• Use of Monitors and Large Video Screens (LVS) as Man Machine


Interface (MMIs) for Operating the Plant

• Use of Process Analysis, Diagnosis and Optimization (PADO) for the


first time in NTPC

• Flame Analysis of Boiler by Dedicated Scanners for all Coal


Burners

• Boiler Mapping By Acoustic Pyrometers

• Use of Distributed Digital Control and Management Information


System (DDCMIS)

• Totally Spring Loaded Floating Foundation for all Major


Equipments Including TG

• Use of INERGEN as Fire Protection System for the 1st time in


NTPC

• Use of Digital Automatic Voltage Regulator (DAVR)

• Use of VFD in ID Fan

17
NTPC POWER STATIONS IN INDIA

18
Principle and Operation of a Thermal Power
Plant
Principle:

Any Steam Power Plant operates under the Simple Rankine Cycle.
Hence the Rankine cycle is often termed as Basic Power Plant Cycle.

The Rankine Cycle


The Rankine cycle is a thermodynamic cycle which converts heat into
work. The heat is supplied externally to a closed loop, which usually uses
water as the working fluid. This cycle generates about 80% of all electric
power used throughout the world, including virtually all solar, thermal,
biomass, coal and nuclear power plants. It is named after William John
Macquorn Rankine, a Scottish polymath. The thermal (steam) power plant
uses a dual (vapour+liquid) phase cycle. It is a closed cycle to enable
the working fluid (water) to be used again and again.

Layout of a Simple T-S diagram of a Simple


Rankine Cycle Rankine Cycle

The basic principle of the working of a Thermal Power Plant is quite


simple. The fuel used in the plant is burnt in the boiler, and the heat
generated is then used to boil water which is circulated through several

19
tubes, the steam that is generated is used to drive a turbine, which in
turn is coupled with a generator, which then produces the electricity.
A Rankine cycle describes a model of the operation of steam heat
engines most commonly found in power generation plants. Common
heat sources for power plants using the Rankine cycle are coal, natural gas,
oil, and nuclear. The Rankine cycle is sometimes referred to as a practical
Carnot cycle as, when an efficient turbine is used, the TS diagram will
begin to resemble the Carnot cycle. The main difference is that a pump
is used to pressurize liquid instead of a gas. This requires about 1/100th
(1%) as much energy as that compressing a gas in a compressor (as in the
Carnot cycle).The efficiency of a Rankine cycle is usually limited by the
working fluid. Without the pressure going super critical the temperature
range the cycle can operate over is quite small, turbine entry
temperatures are typically 565°C (the creep limit of stainless steel) and
condenser temperatures are around 30°C. This gives a theoretical
Carnot efficiency of around 63% compared with an actual efficiency of
42% for a modern coal-fired power station. This low turbine entry
temperature (compared with a gas turbine) is why the Rankine cycle is
often used as a bottoming cycle in combined cycle gas turbine power stations.
The working fluid in a Rankine cycle follows a closed loop and is re-used
constantly. The water vapor and entrained droplets often seen billowing
from power stations is generated by the cooling systems (not from the
closed loop Rankine power cycle) and represents the waste heat that
could not be converted to useful work.
Note that cooling towers operate using the latent heat of vaporization of
the cooling fluid. The white billowing clouds that form in cooling tower
operation are the result of water droplets which are entrained in the
cooling tower airflow; it is not, as commonly thought, steam. While many
substances could be used in the Rankine cycle, water is usually the fluid

20
of choice due to its favorable properties, such as nontoxic and un
reactive chemistry, abundance, and low cost, as well as its thermodynamic
properties. One of the principal advantages it holds over other cycles is
that during the compression stage relatively little work is required to drive
the pump, due to the working fluid being in its liquid phase at this point.
By condensing the fluid to liquid, the work required by the pump will only
consume approximately 1% to 3% of the turbine power and so give a
much higher efficiency for a real cycle. The benefit of this is lost
somewhat due to the lower heat addition temperature. Gas turbines, for
instance, have turbine entry temperatures approaching 1500°C.
Nonetheless, the efficiencies of steam cycles and gas turbines are fairly well
matched.
Ts diagram of a typical Rankine cycle operating between pressures of
0.06bar and 50bar.

T-S diagram of a Typical


Rankine cycle

There are four processes in the Rankine cycle, each changing the state
of the working fluid. These states are identified by number in the diagram
to the right

21
I. Process 1-2: The working fluid is pumped from low to high
pressure, as the fluid is a liquid at this stage the pump requires
little input energy.
II. Process 2-3: The high pressure liquid enters a boiler where it is
heated at constant pressure by an external heat source to become
a dry saturated vapor.
III. Process 3-4: The dry saturated vapor expands through a turbine,
generating power. This decreases the temperature and pressure of
the vapor and some condensation may occur.
IV. Process 4-1: The wet vapor then enters a condenser where it is
condensed at a constant pressure and temperature to become a
saturated liquid. The pressure and temperature of the condenser is
fixed by the temperature of the cooling coils as the fluid is
undergoing a phase-change.
In an ideal Rankine cycle the pump and turbine would be isentropic, i.e.,
the pump and turbine would generate no entropy and hence maximize
the net work output processes1-2and 3-4 would be represented by vertical lines
onthe Ts diagram. The Rankine cycle shown here prevents the vapor
ending up in the superheat region after the expansion in the turbine,
which reduces the energy removed by the condensers.

In a real Rankine cycle, the compression by the pump and the


expansion in the turbine are not isentropic. In other words, these
processes are non-reversible and entropy is increased during the two
processes. This somewhat increases the power required by the pump
and decreases the power generated by the turbine. In particular the
efficiency of the steam turbine will be limited by water droplet formation. As
the water condenses, water droplets hit the turbine blades at high speed
causing pitting and erosion, gradually decreasing the life of turbine

22
blades and efficiency of the turbine. The easiest way to overcome this
problem is by superheating the steam. On the Ts diagram above, state 3
is above a two phase region of steam and water so after expansion the
steam will be very wet. By superheating, state 3 will move to the right
of the diagram and hence produce a dryer steam after expansion.

Rankine Cycle with superheating

Rankine Cycle with Reheat

In this two turbines work in series on a common shaft. The first accepts
vapor from the boiler at a high pressure. After the vapor has passed
through the first turbine (also referred as H.P turbine), it renters the
boiler and is reheated before it is allowed to pass through the second
turbine (often referred to as L.P turbine).It prevents the vapor from
condensing during its expansion which can intensely damage the turbine
blades, and improves the efficiency of the cycle by decreasing the net
work output. To protect the reheat tubes, steam is not allowed to expand

23
deep into the two-phase region before it is taken for reheating, because
in that case the moisture particles in the steam while evaporating would
leave behind solid deposits in the form of scale which is difficult to
remove. A low reheat pressure may bring down the cycle efficiency.
Again, a high reheat pressure increases the moisture content at turbine
exhaust. Thus the reheat pressure is optimized. By increasing the
number of reheats, still higher steam pressures could be used, but
mechanical stresses increase at a higher proportion then the increase in
pressure, also increase. Hence more than two reheats have not been
used so far.

Rankine Cycle with Reheat

Regenerative Rankine Cycle

The main aim of the Regenerative Rankine cycle is to improve the cycle
efficiency by decreasing the net heat input. In Regenerative Rankine
cycle, after emerging from the condenser (possibly as a sub cooled
liquid) the working fluid is heated by steam tapped from the hot portion
of the cycle (i.e. from the intermediate stages of the turbine). On the

24
diagram shown, the fluid at 2 is mixed with the fluid at 4 (both at the
same pressure) to end up with a saturated liquid at 7.

Regenerative Rankine Cycle

Reheat-Regenerative Cycle

The reheating of steam is adopted when the vaporization pressure is


high. The effect of reheat alone on the thermal efficiency of the cycle is
very small. Regeneration or the heating up of feed water by steam
extracted from the turbine has a marked effect on cycle efficiency. The
Reheat-Regenerative Rankine cycle (with minor variants) is commonly
used in modern steam power stations. Another variation is where 'bleed
steam' from between turbine stages is sent to feed water heaters to
preheat thewateron its way from the condenser to the boiler.

25
Reheat – Regenerative Rankine
Cycle

Factors affecting thermal cycle efficiency

1. Initial steam pressure


2. Initial steam temperature
3. Reheat pressure and temperature, if reheat is used
4. Condenser pressure
5. Regenerative feed water heating

Operation-Fundamentals of Coal to Electricity:

Operation of a Steam Power Plant


26
27
MM

Mechanical Power to Electric Power

As the blades of the turbine rotate, the shaft of the generator which is coupled to that of the
turbine also rotates .It causes rotation of the exciter which produces an induced emf
(electric power)

28
Principle components of a 500MW thermal
power plant

A typical 500MW Thermal Power


Plant

Any 500MW thermal power plant comprises of the following


components:

1. Cooling tower
2. Cooling water pump
3. Transmission line (3-phase)
4. Unit transformer (3-phase)
5. Electric generator (3-phase)
6. Low pressure turbine
7. Feed Water Pump

29
8. Condenser
9. Intermediate pressure turbine
10. Steam governor valve
11. High pressure turbine
12. Deaerator
13. Feed heater
14. Coal conveyor
15. Coal hopper
16. Pulverized coal mill
17. Boiler drum
18. Ash hopper
19. Super heater
20. Forced draught fan
21. Re heater
22. Air intake tower
23. Economizer
24. Air pre heater
25. Electrostatic Precipitator (ESP)
26. Induced draught fan
27. Flue Gas

1. Cooling Tower
Cooling towers are heat removal devices used to transfer process
waste heat to the atmosphere. Cooling towers may either use the
evaporation of water to remove process heat and cool the working
fluid to near the wet-bulb air temperature or in the case of closed
circuit dry cooling towers rely solely on air to cool the working fluid to
near the dry-bulb air temperature. However, evaporative type cooling

30
towers are most commonly used. Common applications include
cooling the circulating water used in oil refineries, chemical plants,
power stations and building cooling. The towers vary in size from
small roof-top units to very large hyperboloid structures that can be
up to 200 meters tall and 100 meters in diameter, or rectangular
structures that can be over 40 meters tall and 80 meters long.
Smaller towers are normally factory-built, while larger ones are
constructed on site. The absorbed heat is rejected to the atmosphere
by the evaporation of some of the cooling water in mechanical
forced-draft or induced Draft towers or in natural draft hyperbolic
shaped cooling towers as seen at most nuclear power plants.

2. Cooling Water Pump


It pumps the water from the cooling tower to the condenser.

3. Three Phase Transmission line


Three phase electric power is a common method of electric power
transmission. It is a type of polyphase system mainly used to power
motors and many other devices. A three phase system uses less
conductive material to transmit electric power than equivalent single
phase, two phase, or direct current system at the same voltage. In a
three phase system, three circuits reach their instantaneous peak
values at different times. Taking current in one conductor as the
reference, the currents in the other two are delayed in time by one-
third and two-third of one cycle .This delay between “phases” has the
effect of giving constant power transfer over each cycle of the current
and also makes it possible to produce a rotating magnetic field in an
electric motor. At the power station, an electric generator converts
mechanical power into a set of electric currents, one from each

31
electromagnetic coil or winding of the generator. The current are
sinusoidal functions of time, all at the same frequency but offset in
time to give different phases. In a three phase system the phases are
spaced equally, giving a phase separation of one-third of one cycle.
Generators output at a voltage that ranges from hundreds of volts to
30,000 volts.

4. Unit transformer (3-phase)


At the power station, transformers step-up this voltage to one more
suitable for transmission. After numerous further conversions in the
transmission and distribution network the power is finally transformed
to the standard mains voltage (i.e. the “household” voltage). The
power may already have been split into single phase at this point or it
may still be three phase. Where the step-down is three phase at the
receiving stage, the output of this transformer is usually star
connected with the standard mains voltage being the phase-neutral
voltage. Another system commonly seen in North America is to have
a delta connected secondary with a center tap on one of the
windings supplying the ground and neutral. This allows for 240 V
three phase as well as three different single phase voltages( 120 V
between two of the phases and neutral , 208 V between the third
phase ( or wild leg) and neutral and 240 V between any two phase)
to be available from the same supply.

A unit Transformer 32
5. Electrical generator
An Electrical generator is a device that converts kinetic energy to
electrical energy, generally using electromagnetic induction. The task
of converting the electrical energy into mechanical energy is
accomplished by using a motor. The source of mechanical energy
maybe water falling through the turbine or steam turning a turbine (as
is the case with thermal power plants). There are several
classifications for modern steam turbines. Steam turbines are used in
our entire major coal fired power stations to drive the generators or
alternators, which produce electricity. The turbines themselves are
driven by steam generated in "boilers “or "steam generators" as they
are sometimes called. Electrical power stations use large steam
turbines driving electric generators to produce most (about 86%) of
the world’s electricity. These centralized stations are of two types:
fossil fuel power plants and nuclear power plants. The turbines used
for electric power generation are most often directly coupled to their-
generators .As the generators must rotate at constant synchronous
speeds according to the frequency of the electric power system, the
most common speeds are 3000 r/min for 50 Hz systems, and 3600
r/min for 60 Hz systems. Most large nuclear sets rotate at half those
speeds, and have a 4-pole generator rather than the more common
2-pole one.

An electric generator with an excitor 33


6. Low Pressure Turbine
Energy in the steam after it leaves the boiler is converted into
rotational energy as it passes through the turbine. The turbine
normally consists of several stages with each stages consisting of a
stationary blade (or nozzle) and a rotating blade. Stationary blades
convert the potential energy of the steam into kinetic energy and
direct the flow onto the rotating blades. The rotating blades convert
the kinetic energy into impulse and reaction forces, caused by
pressure drop, which results in the rotation of the turbine shaft. The
turbine shaft is connected to a generator, which produces the
electrical energy. Low Pressure Turbine (LPT) consists of 2x6
stages. After passing through Intermediate Pressure Turbine steam
is passed through LPT which is made up of two parts- LPC REAR &
LPC FRONT. As water gets cooler here it gathers into a HOTWELL
placed in lower parts of turbine.

7. Feed Water Pump


A Boiler feed water pump or simply a feed water pump is a specific
type of pump used to pump water into a steam boiler. The water may
be freshly supplied or returning condensation of the steam produced
by the boiler. These pumps are normally high pressure units that use
suction from a condensate return system and can be of the
centrifugal pump type or positive displacement type. Feed water
pumps range in size up to many horsepower and the electric motor is
usually separated from the pump body by some form of mechanical
coupling. Large industrial condensate pumps may also serve as the
feed water pump. In either case, to force the water into the boiler, the
pump must generate sufficient pressure to overcome the steam
pressure developed by the boiler. This is usually accomplished

34
through the use of a centrifugal pump. Feed water pumps usually run
intermittently and are controlled by a float switch or other similar
level-sensing device energizing the pump when it detects a lowered
liquid level in the boiler. Some pumps contain a two-stage switch. As
liquid lowers to the trigger point of the first stage, the pump is
activated. If the liquid continues to drop, (perhaps because the pump
has failed, its supply has been cut off or exhausted, or its discharge
is blocked) the second stage will be triggered. This stage may switch
off the boiler equipment (preventing the boiler from running dry and
overheating); trigger an alarm, or both.

8. Condenser
The steam coming out from the Low Pressure Turbine (a little above
its boiling pump) is brought into thermal contact with cold water
(pumped in from the cooling tower) in the condenser, where it
condenses rapidly back into water, creating near Vacuum-like
conditions inside the condenser chest allowing it to be pumped. If the
condenser can be made cooler, the pressure of the exhaust steam is
reduced and efficiency of the cycle increases. The surface
condenser is a shell and tube heat exchanger in which cooling water
is circulated through the tubes. The exhaust steam from the low
pressure turbine enters the shell where it is cooled and converted to
condensate (water) by flowing over the tubes as shown in the
adjacent diagram. Such condensers use steam ejectors or rotary
motor-driven exhausters for continuous removal of air and gases
from the steam side to maintain vacuum.

35
9. Intermediate Pressure Turbine
Intermediate Pressure Turbine (IPT) consists of 12 stages. When the
steam has been passed through HPT it enters into IPT. IPT has two
ends named as FRONT & REAR. Steam enters through front end
and leaves from Rear end.

10. Steam Governor Valve


Steam locomotives and the steam engines used on ships and
stationary applications such as power plants also required feed water
pumps. In this situation, though, the pump was often powered using
a small steam engine that ran using the steam produced by the boiler
a means had to be provided, of course, to put the initial charge of
water into the boiler (before steam power was available to operate
the steam-powered feed water pump).The pump was often a positive
displacement pump that had steam valves and cylinders at one end
and feed water cylinders at the other end; no crankshaft was
required. In thermal plants, the primary purpose of surface
condenser is to condense the exhaust steam from a steam turbine to
obtain maximum efficiency and also to convert the turbine exhaust
steam into pure water so that it may be reused in the steam
generator or boiler as boiler feed water. By condensing the exhaust
steam of a turbine at a pressure below atmospheric pressure, the
steam pressure drop between the inlet and exhaust of the turbine is
increased, which increases the amount heat available for conversion
to mechanical power. Most of the heat liberated due to condensation
of the exhaust steam is carried away by the cooling medium (water
or air) used by the surface condenser. Control valves are valves
used within industrial plants and elsewhere to control operating

36
conditions such as temperature, pressure, flow and liquid level by
fully or partially opening or closing in response to signals received
from controllers that compares a “set point” to a “process variable”
whose value is provided by sensors that monitor changes in such
conditions. The opening or closing of control valves is done by
means of electrical, hydraulic or pneumatic systems.

11. High Pressure Turbine


Steam coming from Boiler directly feeds into HPT at a temperature of
540°C and at a pressure of 170 kg/cm2. Here it passes through 12
different stages due to which its temperature goes down to 350°C
and pressure as 45 kg/cm2. This line is also called as CRH – COLD
REHEAT LINE. It is now passed to a REHEATER where its
temperature rises to 540°C and called as HRH-HOT REHEATED
LINE.

12. Deaerator
A Deaerator is a boiler feed device for air removal and used to
remove dissolved gases (an alternate would be the use of water
treatment chemicals) from boiler feed water to make it noncorrosive.
A deaerator is an open type feed water heater. A dearator typically
includes a vertical domed deaeration section as the deaeration boiler
feed water tank. A steam generating boiler requires that the
circulating steam, condensate, and feed water should be devoid of
dissolved gases, particularly corrosive ones and dissolved or
suspended solids. The gases will give rise to corrosion of the metal.
The solids will deposit on the heating surfaces giving rise to localized
heating and tube ruptures due to overheating. Under some
conditions it may give rise to stress corrosion cracking. Deaerator

37
level and pressure must be controlled by adjusting control valves the
level by regulating condensate flow and the pressure by regulating
steam flow. If operated properly, most deaerators will guarantee that
oxygen in the deaerated water will not exceed 7 ppb by weight
(0.005 cm3/L).

13. Feed water heater


A Feed water heater is a power plant component used to pre-heat
water delivered to a steam generating boiler. Preheating the feed
water reduces the irreversibility involved in steam generation and
therefore improves the thermodynamic efficiency of the system. This
reduces plant operating costs and also helps to avoid thermal shock
to the boiler metal when the feed water is introduced back into the
steam cycle. In a steam power (usually modeled as a modified
Rankine cycle), feed water heaters allow the feed water to be
brought up to the saturation temperature very gradually. This
minimizes the inevitable irreversibility associated with heat transfer to
the working fluid (water).

14. Coal conveyor


Coal conveyors are belts which are used to transfer coal from its
storage place to Coal Hopper. A belt conveyor consists of two
pulleys, with a continuous loop of material- the conveyor Belt – that
rotates about them. The pulleys are powered, moving the belt and
the material on the belt forward. Conveyor belts are extensively used
to transport industrial and agricultural material, such as grain, coal,
ores etc.

38
15. Coal Hopper
Coal Hoppers are the places which are used to feed coal to Coal Mill.
It also has the arrangement of entering Hot Air at 200°C inside it
which solves our two purposes:
1. If our Coal has moisture content then it dries it so that a proper
combustion takes place.
2. It raises the temperature of coal so that its temperature is more
near to its Ignite Temperature so that combustion is easy.

16. Pulverized Coal Mill


A pulverizer is a mechanical device for grinding coal for combustion
in a furnace in a Thermal power plant.

17. Boiler drum


Steam Drums are a regular feature of water tube boilers. It is
reservoir of water/steam at the top end of the water tubes in the
water-tube boiler. They store the steam generated in the water tubes
and act as a phase separator for the steam/water mixture. Usually,
the boiler drum is at an elevation of 75m. The difference in densities
between hot and cold water helps in the accumulation of the “hotter”-
water/and saturated –steam into steam drum. Made from high-grade
steel (probably stainless) and its working involve temperature of
390°C and pressure well above 350psi (2.4MPa). The separated
steam is drawn out from the top section of the drum. Saturated
Steam is drawn off the top of the drum. The steam will re-enter the
furnace in through a super heater, while the saturated water at the
bottom of steam drum flows down to the mud-drum /feed water drum
by down comer tubes accessories include a safety valve, water level

39
indicator and fuse plug. A steam drum is used in company of a mud-
drum/feed water drum which is located at a lower level. So that it
acts as a sump for the sludge or sediments which have a higher
tendency at the bottom.

18. Ash Hopper


A steam drum is used in the company of a mud-drum/feed water
drum which is located at a lower level. So that it acts as a sump for
the sludge or sediments which have a tendency to accumulate at the
bottom.

19. Super Heater


A Super heater is a device in a steam engine that heats the steam
generated by the boiler again increasing its thermal energy. Super
heaters increase the efficiency of the steam engine, and were widely
adopted. Steam which has been superheated is logically known as
superheated steam; non- superheated steam is called saturated
steam or wet steam. Super heaters are being applied most stationary
steam engines including power stations. The dry steam coming out
of the boiler drum passes through three stages of superheating.
Initially the main steam is passed through a low temperature super
heater followed by a divisional panel super heater and finally through
a platen super heater. The resulting steam obtained will be at 540o C
this is sent to the inlet of the HP turbine.

20. Force Draught Fan


External fans are provided to give sufficient air for combustion. The
forced draught fan takes air from the atmosphere and, warms it in the

40
air pre heater for better combustion, injects it via the air nozzles on
the furnace wall.

21. Re heater
Re heater is a heater which is used to raise the temperature of steam
which has exhausted from the high pressure turbine. The steam
entering the re heater is known as Cold Reheat (CR). The steam
leaving the re heater is known as Hot Reheat (HR).

22. Air Intake


Air is taken from the environment by an air intake tower which is fed
to the fuel.

23. Economizer
Economizers are mechanical devices intended to reduce energy
consumption, or to perform another useful function like preheating a
fluid. The term economizer is used for other purposes as well-Boiler,
power plant, heating, ventilating and air-conditioning. In boilers,
economizer are heat exchange devices that heat fluids , usually
water, up to but not normally beyond the boiling point of the fluid.
Economizers are so named because they can make use of the
enthalpy and improving the boiler’s efficiency. They are devices fitted
to a boiler which save energy by using the heat from the exhaust
gases from the boiler to preheat the cold water used to fill it (the feed
water). Modern day boilers, such as those in cold fired power
stations, are still fitted with economizer which is decedents of
Green’s original design. In this context there are turbines before it is
pumped to the boilers. A common application of economizer in steam
power plants is to capture the waste heat from boiler stack gases

41
(flue gas) and transfer thus it to the boiler feed water thus lowering
the needed energy input , in turn reducing the firing rates to
accomplish the rated boiler output . Economizer lower stack
temperatures which may cause condensation of acidic combustion
gases and serious equipment corrosion damage if care is not taken
in their design and material selection.

24. Air Pre heater


Air pre heater is a general term to describe any device designed to
heat air before another process (for example, combustion in a boiler).
The purpose of the air pre heater is to recover the heat from the
boiler flue gas which increases the thermal efficiency of the boiler by
reducing the useful heat lost in the flue gas. As a consequence, the
flue gases are also sent to the flue gas stack (or chimney) at a lower
temperature allowing simplified design of the ducting and the flue gas
stack. It also allows control over the temperature of gases leaving the
stack (chimney).

25. Electrostatic Precipitator (ESP)


An Electrostatic precipitator (ESP) or electrostatic air cleaner is a
particulate device that removes particles from a flowing gas (such as
air) using the force of an induced electrostatic charge. Electrostatic
precipitators are highly efficient filtration devices, and can easily
remove fine particulate matter such as dust and smoke from the air
steam. ESPs continue to be excellent devices for control of many
industrial particulate emissions, including smoke from electricity-
generating utilities (coal and oil fired), salt cake collection from black
liquor boilers in pump mills, and catalyst collection from fluidized bed
catalytic crackers from several hundred thousand ACFM in the

42
largest coal-fired boiler applications. The original parallel plate-
Weighted wire design (described above) has evolved as more
efficient (and robust) discharge electrode designs, today focus is on
rigid discharge electrodes to which many sharpened spikes are
attached , maximizing corona production. Transformer –rectifier
systems apply voltages of 50-100 Kilovolts at relatively high current
densities. Modern controls minimize sparking and prevent arcing,
avoiding damage to the components. Automatic rapping systems and
hopper evacuation systems remove the collected particulate matter
while on line allowing ESPs to stay in operation for years at a time.

26. Induced Draught Fan


The induced draft fan assists the FD fan by drawing out combustible
gases from the furnace, maintaining a slightly negative pressure in
the furnace to avoid backfiring through any opening. At the furnace
outlet and before the furnace gases are handled by the ID fan, fine
dust carried by the outlet gases is removed to avoid atmospheric
pollution. This is an environmental limitation prescribed by law, which
additionally minimizes erosion of the ID fan.

27. Flue gas stack


A Flue gas stack is a type of chimney, a vertical pipe, channel or
similar structure through which combustion product gases called flue
gases are exhausted to the outside air. Flue gases are produced
when coal, oil, natural gas, wood or any other large combustion
device. Flue gas is usually composed of carbon dioxide (CO2) and
water vapor as well as nitrogen and excess oxygen remaining from
the intake combustion air. It also contains a small percentage of
pollutants such as particulates matter, carbon mono oxide, nitrogen

43
oxides and sulphur oxides. The flue gas stacks are often quite tall, up
to 400 meters (1300 feet) or more, so as to disperse the exhaust
pollutants over a greater area and thereby reduce the concentration
of the pollutants to the levels required by government's
environmental policies and regulations.

44
The Layout of NTPC Simhadri

The plant consists of two stages: Stage 1 (consisting of unit 1 and


unit 2) and Stage 2 (consisting of unit 3 and unit 4).Each unit has an
average capacity of 500MW.The boilers used in all the units are sub
critical type and employ tilting tangential firing. Each unit of stage 1
comprises of nine coal mills (bowl mills) while each unit of stage 2
consists of ten coal mills. In addition to, an HP turbine and an LP
turbine the plant uses an IP turbine too. Each pressure part in a unit
employs three pumps out of which one is a standby and two are
under service. Similarly, each unit uses four air pre heaters; two are
under service while the other two are for standby. The plant uses DM
water for steam generation and raw water for cooling purpose. The
plant uses Natural Draught Cooling System. The lube oil that is used
for lubrication and cooling purpose is Servo prime 46. For governing
the speed of the turbine throttle governing is employed. The output of
the plant is distributed and transmitted through a three phase
transmission system (Switch yard). The switch yard is of a one and
half breaker bus configuration. It uses Global Positioning System for
time synchronization. The plant uses a two pole synchronous
brushless generator. (Water cooled stator and hydrogen cooled
rotor).

45
A GENERAL LAYOUT OF A UNIT OF NTPC SIMHADRI
46
BOILER MAINTAINANCE
DEPARTMENT

47
Boiler and its auxiliaries

Boiler:

According to IBR, any closed vessel exceeding 22.75 liters in capacity


and which is used expressively for generating steam under pressure and
includes any mounting or other fitting attached to such vessel, which is
wholly, or partly under pressure when the steam is shut off can be
termed as a steam boiler. A boiler is the central or an important
component of the thermal power plant which focuses on producing
superheated steams that is used for running of the turbines which in turn
is used for the generation of electricity. A boiler is a closed vessel in
which the heat produced by the combustion of fuel is transferred to
water for its conversation into steam of the desired temperature &
pressure. The steam generating boiler has to produce steam at the
highest purity, pressure and temperature required for the steam
turbine that drives the electrical generator.
The heat-generating unit includes a furnace in which the fuel is burned.
With the advantage of water-cooled furnace walls, super heaters, air
heaters and economizers, the term steam generator was evolved as a
better description of the apparatus.

The boiler is a rectangular furnace about 50 ft (15 m) on a side and 130 ft (40 m)
tall. Its walls are made of a web of high pressure steel tubes about 2.3
inches (60mm) in diameter. Pulverized coal is air-blown into the furnace
from fuel nozzles at the four corners and it rapidly burns, forming a large fireball
at the center. The thermal radiation of the fireball heats the water that
circulates through the boiler tubes near the boiler perimeter. The
water circulation rate in the boiler is three to four times the throughput
and is typically driven by pumps. As the water in the boiler circulates it
48
absorbs heat and changes into steam at 370 °C and 3,200 psi (22.1MPa). It
is separated from the water inside a drum at the top of the furnace. The
saturated steam is introduced into superheat pendant tubes that hang in
the hottest part of the combustion gases as they exit the furnace. Here
the steam is superheated to 540 °C to prepare it for the turbine. The steam
generating boiler has to produce steam at the high purity, pressure and
temperature required for the steam turbine that drives the electrical
generator. The generator includes the economizer, the steam drum, the
chemical dosing equipment, and the furnace with its steam generating
tubes and the super heating coils. Necessary safety valves are located
at suitable points to avoid excessive boiler pressure. The air and flue
gas path equipment include: forced draft (FD) fan, air pre heater (APH),
boiler furnace, induced draft (ID) fan, fly ash collectors (electrostatic
precipitator or bag house) and the flue gas stack.
Construction of boilers is mainly of steel stainless steel a n d
wr o u g h t i r o n . In l i ve s t e a m models, copper or brass is often use.

An internal section of a boiler


49
For utility purpose, it should generate steam uninterruptedly at operating
pressure and temperature for running steam turbines.
Boilers may be classified on the basis of any of the following
characteristics:
 Use
 Pressure
 Materials
 Size
 Tube Content
 Tube Shape and position
 Firing
 Fuel
 Fluid
 Circulations
 Furnace position
 Furnace type
 General shape
 Trade name
 Special features.

Use: The characteristics of the boiler vary according to the nature of


service performed. Customarily boiler is called either stationary or
mobile. Large units used primarily for electric power generation are
known as control station steam generator or utility plants.
Pressure: To provide safety control over construction features, all boilers
must be constructed in accordance with the Boiler codes, which
differentiates boiler as per their characteristics. Boilers with operating
pressures above 224 kgf/cm2 are known as supercritical boilers, while

50
boilers with operating pressures below 224 kgf/cm2 are known as
subcritical boilers.
Materials: Selection of construction materials is controlled by boiler code
material specifications. Power boilers are usually constructed of special
steels.
Size: Rating code for boiler standardize the size and ratings of boilers
based on heating surfaces. The same is verified by performance tests.
Tube Contents: In addition to ordinary shell type of boiler, there are two
general steel boiler classifications, the fire tube and water tube boilers.
Fire tube boiler is boilers with straight tubes that are surrounded by
water and through which the products of combustion pass. Water tube
boilers are those, in which the tubes themselves contain steam or water,
the heat being applied to the outside surface.
Firing: The boiler may be a fired or unfired pressure vessel. In fired
boilers, the heat applied is a product of fuel combustion. A non-fired
boiler has a heat source other than combustion.
Fuel: Boilers are often designated with respect to the fuel burned.
Fluid: The general concept of a boiler is that of a vessel to generate
steam. A few utility plants have installed mercury boilers.
Circulation: The majority of boilers operate with natural circulation. Some
utilize positive circulation in which the operative fluid may be forced
'once through' or controlled with partial circulation.
Furnace Position: The boiler is an external combustion device in which
the combustion takes place outside the region of boiling water. The
relative location of the furnace to the boiler is indicated by the
description of the furnace as being internally or externally fired.
The furnace is internally fired if the furnace region is completely
surrounded by water.

51
Furnace type: The boiler may be described in terms of the furnace type.

General Shape: During the evaluation of the boiler as a heat producer,


many new shapes and designs have appeared and these are widely
recognized in the trade.
Trade Name: Many manufacturers coin their own name for each boiler
and these names come into common usage as being descriptive of the
boiler.
Special features: Sometimes the type of boiler like differential firing and
Tangential firing are employed. NTPC Simhadri uses tangential firing.

Boilers are generally categorized as follows:


• Steel boilers
• Fire Tube type
• Water tube type
• Horizontal Straight tube

Fire tube boiler type:

Fire-tube boilers rely on hot gases circulating through the boiler inside
tubes that are submerged in water. These gases usually make several
passes through the tubes, thereby transferring their heat through the
tube walls and causing the water to boil on the other side. Fire-tube
boilers are generally available in the range of 20 through 800 boiler
horsepower (BHP) and in pressures up to 150 psi.

Water tube boiler type:


Here the heat source is outside the tubes and the water to be heated is
inside. Most high-pressure and large boilers are of this type. In the
water-tube boiler, gases flow over water-filled tubes. These water-filled
tubes are in turn connected to large containers called drums.

52
The boiler mainly has natural circulation of gases, steam and other
things. They contain vertical membrane water. The pulverized fuel which
is being used in the furnace is fixed tangentially. They consume
approximately 350 ton/hr of coal of about 1370kg/cm2 of pressure
having temperature of 540oC. The first pass of the boiler has a
combustion chamber enclosed with water walls of fusion welded
construction on all four sides. In addition there are four water platens to
increase the radiant heating surface.
Beside this platen super heater re heater sections are also suspended in
the furnace combustion chamber. The first pass is a high heat zone
since the fuel is burn in this pass.
The second pass is surrounded by steam cooled walls on all four sides
as well as roof of the boiler. A horizontal super heater, an economizer &
two air heaters are located in the second pass.
Large boiler capacities are often specified in terms of tons of steam
evaporated per hour under specified steam conditions.
Raw materials for boilers:

• Coal from mines


• Ambient air
• Water from natural resources (river, ponds)
• Generating heat energy
• Air for combustion
• Working fluid for steam generation, possessing heat energy

A 500MW steam generator consumes about 8000 tons of coal every


day. It will be considered good, if it requires about 200 cubic meter of
DM water in a day. It will produce about 9500 tons of Carbon dioxide
every day.

53
Specifications of the boiler (at 100% load)

1) Boiler type: radiant reheat, controlled circulation with rifle tubing, dry
bottom, single drum, dry-bottom type unit, top supported, balanced
draft furnace. (BHEL make).

2) Evaporation SH outlet : 1.725 t/hr


RH outlet : 1.530 t/hr

3) Water Pressure after stop valve : 178 kgf/cm2

4) Steam Temperature at SH outlet: : 5400C

5) Steam Temperature at RH inlet: : 344.10C

6) Steam Temperature at RH outlet: : 5400C

7) Steam Pressure at RH inlet : 42.85 kgf/cm2

8) Steam Pressure at RH outlet: : 43.46 kgf/cm2

9) Feed Water Temperature at ECO : 2560C

10) Furnace Design Pressure : +660 mmwc

54
Boiler drum

It is a type of storage tank much higher placed than the level at which
the boiler is placed, and it is also a place where water and steam are
separated. First the drum is filled with water coming from the
economizer, from where it is brought down with the help of down-
comers, entering the bottom ring headers. From there they enter the
riser, which are nothing but tubes that carries the water (which now is a
liquid-vapor mixture), back to the drum. Now, the steam is sent to the
super heaters while the saturated liquid water is again circulated through
the down-comers and then subsequently through the risers till all the
water in the drum turns into steam and passes to the next stage of
heating that is superheating.
NOTE: For a 660 MW plant, the boiler does not employ any drum;
instead the water and steam go directly into the super heater because
the pressure employed being higher than the critical pressure of water
on further stages of heating will eventually turn completely into steam
without absorbing any latent heat of vaporization since the boiling part in
the T-s curve no longer passes through the saturation dome rather its
goes above the dome.

Sub-critical boiler Super-critical boiler


55
The boiler drum is of fusion-welded design with welded hemi-spherical
dished ends. It is provided with stubs for welding all the connecting
tubes i.e. down comers, risers, pipes, saturated steam o u t l e t .
The function of steam drum internals is to separate th e
water from the steam generated in the furnace walls and to reduce the
dissolved solid contents of the steam below the prescribed limit of 1ppm
and also take care of the sudden change of steam demand for boiler.
The secondary stage of two opposed banks of closely spaced
thin corrugated sheets, which direct the steam and force the remaining
entertained water against the corrugated plates. Since the velocity is
relatively low this water does not get picked up again but runs
down the plates and off the second stage of the two steam outlets.
F r o m t h e s e c o n d a r y s e p a r a t o r s t h e s t e a m f l o ws u p wa r d s
t o t h e series of screen dryers, extending in layers across the length of
the drum. These screens perform the final stage of separation.

In the boiler drum, steam volume increases to 1,600 times from water
and produces tremendous force

Steam Drum Internals


56
In the boiler drum, the steam volume increases to 1,600 times from
water and produces tremendous force. The working fluid within the boiler
drum undergoes evaporation. It is supported on U-structures suspended
on a rigid supporting beam.

Boiler drum lifting in progress

Boiler Drum Specifications

57
The steam drum contains steam separating equipment and internal
piping for distribution of chemicals to the water, for distribution of feed
water and for blow down of the water to reduce solids concentration.

Steam drum internal view

Steam separator

58
Once water enters the boiler or steam generator, the process of adding
the latent heat of vaporization or enthalpy is underway. The boiler
transfers energy to the water by the chemical reaction of burning some
type of fuel. The water enters the boiler through a section in the
convection pass called the economizer. From the economizer it passes
to the steam drum. Once the water enters the steam drum it goes down
the down comers to the lower inlet water wall headers. From the inlet
headers the water rises through the water walls and is eventually turned
into steam due to the heat being generated by the burners located on the front
and rear water walls (typically).As the water is turned into steam/vapor in
the water walls, the steam/vapor once again enters the steam drum.
The steam/vapor is passed through a series of steam and water
separators and then dryers inside the steam drum. The steam
separators and dryers remove the water droplets from the steam and the
cycle through the water walls is repeated. This process is known as
natural circulation. The boiler furnace auxiliary equipment includes coal
feed nozzles and igniter guns, soot blowers, water lancing and observation ports
(in the furnace walls) for observation of the furnace interior.
Furnace explosions due to any accumulation of combustible gases after
a trip out are avoided by flushing out such gases from the combustion
zone before igniting the coal. The steam drum (as well as the super
heater coils and headers) have air vents and drains needed for initial
start-up. The steam drum has an internal device that removes moisture
from the wet steam entering the drum from the steam generating tubes.
The dry steam then flows into the super heater coils.

59
Boiler Furnace

Furnace is primary part of boiler where the c h e m i c a l e n e r g y o f


fuel is converted to thermal energy by
combustion. Furnace is designed for efficient
a n d c o m p l e t e combustion. Major factors that assist for
efficient combustion are a mo u n t o f f u e l i n s i d e t h e f u r n a c e
a n d t u r b u l e n c e , wh i c h c a u s e s rapid mixing between fuel and air.
In modern boilers, water-cooled furnaces are used. In general, oil fired
furnace is employed in the boiler. Normally about 65% of furnace volume
is enough for an oil-fired boiler as compared to the corresponding P.F.
fired boiler. Oil-fired furnace is generally closed at the bottom, as
there is no need to remove slag as in case of P.F. fired boiler. The
bottom part will have small amount of slope to prevent film boiler
building in the bottom tubes. If boiler has to design for both P.F. as
well as oil, the f u r n a c e h a s t o b e d e s i g n e d f o r c o a l , a s
o t h e r w i s e h i g h e r h e a t l o a d i n g wi t h P . F. wi l l c a u s e
s l o g g i n g a n d h i g h f u r n a c e e xi t g a s temperature.
The furnace walls are composed of tubes. The space between the tubes
is fusion welded to form a complete gas tight seal. The furnace arch is
composed of fusion welded tubes. The furnace extended side walls are
composed of fin welded tubes. The back pass front (furnace) roof is
compared of tubes peg fin welded. The spaces between the tubes and
openings are closed with fin material so a completely metallic surface is
exposed to the hot furnace gases. Poured insulation is used at each
horizontal buck stay to form a continuous band around the furnace
thereby preventing flue action of gases between the casing and water
walls. Bottom designs used in these coal fired units are of the open
hopper type, often referred to as the dry bottom type.

60
A water cooled furnace

61
Super Heaters

The steam from the boiler drum is then sent for superheating. This takes
place in three stages. In the first stage, the steam is sent to a simple
super heater, known as the low temperature super heaters (LTSH), after
which the second stage consists of several divisional panel super
heaters (DPSH) or radiant pendent super heaters (RPSH). The final
stage involves further heating in the Platen super heaters (PLSH), after
which the steam is sent through the Main Steam (MS) piping for driving
the turbine.
Superheating is done to increase the dryness fraction of the exiting
steam. This is because if the dryness fraction is low, as is the case with
saturated steam, the presence of moisture can cause corrosion of the
blades of the turbine. Super heated steam also has several merits such
as increased working capacity, ability to increase the plant efficiency,
lesser erosion and so on. It is also of interest to know that while the
super heater increases the temperature of the steam, it does not change
the pressure. There are different stages of super heaters besides the
sidewalls and extended sidewalls. The first stage consists of LTSH (low
temperature super heater), which is conventional mixed type with upper
& lower banks above the economizer assembly in rear pass. The other is
Divisional Panel Super heater which is hanging above in the first pass of
the boiler above the furnace. The third stage is the Platen Super heater
(placed above the furnace in convection path) from where the steam
goes into the HP turbine through the main steam line. The outlet
temperature & pressure of the steam coming out from the super heater
is 5400 Celsius & 157 kg/cm2. After the HP turbine part is crossed the
steam is taken out through an outlet as CRH (Cold Re-heat steam) to be
re-heated again as HRH (Hot Re-heat steam) and then is fed to the IPT
62
(Intermediate pressure turbine) which goes directly to the LPT (Low
pressure turbine) through the IP-LP cross-over.

The enthalpy rise of steam in a given section of the super heater should
not exceed

 250 – 420 kJ/kg for High pressure. > 17 MPa

 < 280 kJ/kg for medium pressure. 7 Mpa – 17 MPa

 < 170 kJ/kg for low pressure. < 7 MPa

Convective Super heaters

63
Platen Super heaters

Pendant Super heaters

64
Super heater specifications
LTSH DPSH PSH
No. of tubes 744 432 400
Outer dia in 44.5 44.5 54.0
mm
Joining Butt Butt Butt
Max. steam 405 (H) 513 550
temperature 444 (P)
Max. gas 450 (H) 524 629
temperature 469 (P)

65
Water walls

The water from the bottom ring header is then transferred to the water
walls, where the first step in the formation of steam occurs by absorbing
heat from the hot interior of the boiler where the coal is burned
continuously. This saturated water steam mixture then enters the boiler
drum.
In a 500 MW unit, the water walls are of vertical type, and have rifled
tubing whereas in a 660 MW unit, the water walls are of spiral type till an
intermediate ring header from where it again goes up as vertical type
water walls. The advantage of the spiral wall tubes ensures an even
distribution of heat, and avoids higher thermal stresses in the water walls
by reducing the fluid temperature differences in the adjacent tubes and
thus minimizes the sagging produced in the tubes.

The above figure depicts the difference between the vertical water
wall and the spiral water wall type of tubing where the vertical water
walls have the rifle type of tubes to increase the surface area unlike
the spiral ones that have plain, smooth surfaces.

66
Heating and evaporation of feed water supplied to the boiler from the
economizers takes place within the water tubes. These are vertical tubes
connected at the top and bottom to the headers. These tubes receive
water from the boiler drum by means of down comers connected
between drum and water walls lower header. Approximately 50% of the
heat released by the combustion of the fuel in the furnace is absorbed
by the water walls.

Tangent tube The construction consists of water wall placed side by


side nearly touching each other. An envelope of thin sheet of steel called
"SKIN CASING" is placed in contact with the tubes, which provides a
seal against furnace leakage.

Tangent water tube

Membrane Water tube A number of tubes are joined by a process of


fusion welding or by means of steel strips called 'fins pressurized
furnace is possible with the related Advantages

67
• Increase in efficiency

• Better load response simpler combustion control.

• Quicker starting and stopping

• Increased availability of boiler.

• Heat transfer is better

• Weight is saved in refractory and structure

• Erection is made easy and quick

Membrane water tube

Down comers

There are six down comers in (500 MW) which carry water from boiler
drum to the ring header. They are installed from outside the furnace
to keep density difference for natural circulation of water & steam.

68
Water wall specifications

Front Side Rear Roof


Wall Wall Wall
OD (mm) 51 51 51 57
D.thickness 5.6 5.6 5.6 6.3
Joining BUTT BUTT BUTT BUTT
Design pressure 208.8 208.8 208.8 203.7
of tube
Max. Pressure 197.8 197.8 197.8 192.7
of tube
DES.MET.TEMP 394 394 394 412

69
Safety valves

Device attached to the boiler for automatically relieving the pressure of


steam before it becomes great enough to cause bursting. The common
spring-loaded type is held closed by a spring designed to open the valve
when the internal pressure reaches a point in excess of the calculated
safe load of the boiler. Safety valves are installed on boilers according to
strict safety norms and IBR recommendation.

A spring loaded safety valve

Boiler stop valves

A steam boiler must be fitted with a stop v a l v e ( a l s o k n o w n


as a crown valve) which isolates the
s t e a m boiler and its pressure from the process or plant. It
is generally an angle pattern globe valve of the screw-down variety.
70
The stop valve is not designed as a t h r o t t l i n g v a l v e , a n d
s h o u l d b e f u l l y o p e n o r c l o s e d . I t s h o u l d always be
opened slowly to prevent any sudden rise in downstream pressure and
associated water hammer, and to help restrict the fall in boiler
pressure and any possible associated priming.

Boiler stop valve

Three types of safety valves are commonly employed at NTPC Simhadri

 Electrically operated valve


 Pneumatically operated valve
 Manually operated valve

71
Economizer

The economizer is a tube-shaped structure which contains water from


the boiler feed pump. This water is heated up by the hot flue gases
which pass through the economizer layout, which then enters the drum.
The economizer is usually placed below the second pass of the boiler,
below the Low Temperature Super heater. As the flue gases are being
constantly produced due to the combustion of coal, the water in the
economizer is being continuously being heated up, resulting in the
formation of steam to a partial extent. Economizer tubes are supported
in such a way that sagging, deflection & expansion will not occur at any
condition of operation. In other words, Boiler Economizers are feed-
water heaters in which the heat from waste gases is recovered to raise
the temperature of feed-water supplied to the boiler. It reduces the
exhaust gas temperature and saves the fuel. Modern power plants use
steel-tube-type economizers. It is divided into several sections of 0.6 –
0.8 m gap.

An Economizer

72
6oC raise in feed water temperature by the economizer corresponds to a
1% saving in fuel consumption. 220 C reduction in flue gas temperature
increases the boiler efficiency by 1%.

Location and arrangement

 Ahead of air-heaters
 Following the primary super-heater or re-heater
 Counter-flow arrangement
 Horizontal placement (to facilitate draining)
 Stop valve and non-return valve incorporated to ensure
recirculation in case of no feed-flow

Plain tube: Several banks of tubes with either-in-line or staggered


type formation which induces more turbulence than the in-line
arrangement. This gives a higher rate of heat transfer and requires
less surface but at the expense of higher draught loss.

73
Welded Fin- tube: Fin welded design is used for improving the heat
transfer.

Fin welded design

Feed pipe: Any pipe or connected fitting wholly or partly under pressure
through which feed water passes directly to a Boiler and which does not
form an integral part thereof.

Steam pipe: Any pipe through which steam passes from a Boiler to a
prime mover or other user or both, if the pressure at which steam passes
through such pipe exceeds 3. 5 Kilograms per square centimeter above
atmospheric pressure or such pipe exceeds 254 millimeters in internal
diameter.

Economizer Specifications

Material Carbon steel


SA210 GRA1
No. of coils 184
Outer diameter of tubes (in mm) 38.1
Actual thickness 5.3
Des.pr of tubes 217.8
Des.pr of headers 219.7

74
Deaerator

A deaerator is a device that is widely used for the removal of air and
other dissolved gases from the feed water to steam-generating boilers.
In particular, dissolved oxygen in boiler feed water will cause serious
corrosion damage in steam systems by attaching to the walls of metal
piping and other metallic equipment and forming oxides (rust). Water
also combines with any dissolved carbon dioxide to form carbonic acid
that causes further corrosion. Most deaerators are designed to remove
oxygen down to levels of 7 ppb by weight (0.005 cm³/L) or less.
There are two basic types of deaerators, the tray-type and the spray-
type:
 The tray-type (also called the cascade-type) includes a vertical
domed deaeration section mounted on top of a horizontal
cylindrical vessel which serves as the deaerated boiler feed water
storage tank.

 The spray-type consists only of a horizontal (or vertical) cylindrical


vessel which serves as both the deaeration section and the boiler
feed water storage tank.

75
Re heater

Purpose: to re-heat the steam from HP turbine to 5400C

It is composed of three sections:

 radiant wall re heater arranged in front & side water walls


 rear pendant section arranged above goose neck
 front section arranged between upper heater platen & rear water
wall hanger tubes

The arrangement and construction of a re-heater is similar to that of a


super-heater. In large modern boiler plant, the reheat sections are mixed
equally with super-heater sections. The pressure drop inside re-heater
tubes has an important adverse effect on the efficiency of turbine.
Pressure drop through the re-heater should be kept as low as possible.
The tube diameter is to be kept between 42 – 60mm. Its design is similar
to convective super-heaters. The Overall Heat Transfer Coefficient lies
between 90 – 110 W/m2 K. Reheating is another method of increasing
the cycle efficiency.

Re heater specifications

Max. operating pressure in kgf/cm2 46.7


Design pressure in kgf/cm2 52.4
Max. steam temperature in 0C 540
Max. gas side mean temp in 0C 593
Outer diameter (in mm) 54.0
Total no. of tubes 888
Joining butt

76
Coal system: Coal burners

Coal burners comprise of a coal nozzle, steel tip, seal plate and tilting
link mechanism, housed in coal compartment in all four corners of the
furnace and connected with coal pipes. One end (outlet) is rectangular
and another end is cylindrical. The burner can be tilted on a pivot pin.
The angle of tilt for the burner is about -300 to +300. The nozzle tip has
separate coal and air passages. Coal and air passages are divided into
several parts. Each boiler of one unit consists of eight pulverized coal
burners. The pulverized coal is mixed with primary air flow which carries
the coal mixture to each of the four corners of the furnace burner
nozzles and into the furnace. Coal is pulverized to achieve optimum
efficiency.

Coal burners
77
Fuel- Oil system

Purpose:

(a) To establish initial boiler light up.

(b) To support the furnace flame during low load operation up to 15%
MCR load.

The Fuel oil system consists of

 Fuel oil Pumps


 Oil heaters
 Filters
 Steam tracing lines

The main objective is to get filtered oil at correct pressure and


temperature.

The Fuel Oil system prepares any of the two designated fuel oil for use
in oil burners (16 per boiler, 4 per elevation) to establish the above two
stated purposes. To achieve this, the system incorporates fuel oil
pumps, oil heaters, and filters, steam tracing lines which together ensure
that the fuel oil is progressively filtered, raised in temperature, raised in
pressure and delivered to the oil burners at the requisite atomizing
viscosity for optimum efficiency in the furnace.

Both the oil and coal burner nozzles fire at a tangent to an imaginary
circle at the furnace centre. The turbulent swirling action thus produces,
promotes the necessary mixing of the fuels and air to ensure complete
combustion of the fuel. A vertical tilt facility of the burner nozzles, which
is controlled by the automatic control system of the boiler, ensures
constant reheat outlet steam temperature at varying boiler loads.

78
Tangential Firing in a boiler furnace

In the tangential firing system the furnace itself constitutes the burner.
Fuel and air are introduced through the furnace through four wind box
assemblies located in the furnace corners. The fuel and air streams from
the wind box nozzles are directed to a firing circle in the centre of the
furnace. The rotative or cyclonic action that is the characteristic of this
type of firing is most effective in turbulently mixing the burning fuel in a
constantly changing air and gas atmosphere.

Oil burners:

Design Considerations

• Atomization of oil

• Properly shaped jet

• Complete combustion

• Excess air should be minimum

• Ready accessibility for repairs

79
The three main oils used in the oil burners are:

a) Light Diesel Oil

b) Heavy fuel oil

c) Low sulphur heavy stock (LSHS).

Heavy oil guns are used for stabilizing flame at low load carrying. Warm
up oil guns are used for cold boiler warm up during cold start up and
igniters are used for start up and oil flame stabilizing.

Operating Principle (Atomization):

Atomization breaks the fuel into fine particles that readily mixes with the
air for combustion. Oil should be divided up into small particles for
effective atomization.

The advantages of atomization are:

a) Atomizing burners can be used with heavier grades of oil.

b) Can be adopted to large applications because of its large capacity


range.

c) Complete combustion is assured by the ability of the small particles to


penetrate in turbulent combustion.

Atomization of fuel oil is done by means of oil guns.

Oil burners are classified according to the method used for atomization,
as follows:

a) Air-atomized burners

b) Steam-atomized burners

c) Mechanically atomized burners


80
Air atomizing systems are not recommended for heavy oil system as
they tend to chill the oil and decrease atomization quality.

Steam atomization system uses auxiliary steam to assist in the


atomization of the oil. The steam used in this method should be slightly
superheated and free from moisture. As in the case of air atomizing
system, the steam here is used for both atomizing as well as heating the
fuel as it pass through the tip and into the furnace. The main advantages
of steam atomizing burners over other are:

a) Simplicity of its design

b) Initial cost of installation is low

c) Low pumping pressure

d) Low preheating temperature.

HFO being a highly viscous fluid is atomized using auxiliary steam. Upon
passing hot steam, the temperature of HFO increases, this decreases
the viscosity of HFO and hence the oil can be freely transported from the
oil sump to the boiler furnace. This process is known as Steam Tracing.

81
Wind box assembly

The fuel firing equipment consists of four wind box assemblies located in
the furnace corners. Each wind box assembly is divided in its height into
a number of sections or compartments. The coal components (fuel air
compartment) contain air (intermediate air compartments). Combustion
air (secondary air) is admitted to the intermediate air compartments and
each fuel compartment (around the fuel nozzle) through sets of lower
dampers. Each set of dampers is operated by a damper drive cylinder
located at the side of the wind box. The drive cylinder at each elevation
(25 m to 35 m) are operated either remote manually or automatically by
the secondary air damper control system. Some of the (auxiliary) air
components between coal nozzles contain oil guns. Retractable High
Energy Arc (HEA) igniters are located adjacent to the retractable oil
guns. These igniters directly light up the oil guns.

Wind box Arrangement


82
All auxiliary air dampers regulate the wind box to furnace DP as per the
set point which is generated with respect to Boiler Load Index. All fuel air
dampers regulate in proportion to the fuel firing rate. Oil dampers are
used to maintain a rich mixture of air/oil at the time of Oil Firing. Over fire
dampers are used to reduce SOx & NOx percentage.

The function of the wind box component dampers is to proportion the


amount of secondary air admitted to an elevation pf fuel components in
relation to that admitted to adjacent elevation of auxiliary air components

Wind box Arrangement

83
An overview of Firing System

84
Coal bunkers and Feeders

Coal Bunker: These are in process storage silos used for s t o r i n g


c r u s h e d c o a l f r o m t h e c o a l h a n d l i n g s ys t e m. G e n e r a l l y,
these are made up of welded steel plates. Normally, there are six such
bunkers supplying coal of the corresponding mills. These are located on
top of the mills so as to aid in gravity feeding of coal.
Coal Feeder: Coal feeders are used to regulate the flow of coal from
bunker to the pulverizer. Each mill is provided with a drag link
chain/ rotary/ gravimetric f e e d e r t o t r a n s p o r t r a w c o a l f r o m
t h e b u n k e r t o t h e i n l e t c h u t e , leading to mill at a desired rate.

There are principally three types of feeders namely:


 Chain Feeder
 Belt Feeder or gravimetric feeder
 Table type belt Feeder
NTPC Simhadri employs gravimetric pulverizer to feed the Coal from
Bunker to Pulverizer as per requirement. It comprises of a leveling bar to
check the level of coal in the bunker. It uses a specialized belt conveyer
whose belt speed can be varied as per the requirement. The amount of
Coal entry is controlled by the speed of the drive pulley. The drive pulley
is connected through the motor with variable speed drive. Either a DC
Motor or a Motor with Magnetic clutch is used.

Gravimetric feeder
85
Bunker and feeder
arrangement

Gravimetric Feeder

Gravimetric Feeder used in NTPC Simhadri 86


Coal mills (Pulverizers)

As the name suggests the coal particles are grinded into finer sized
granules. The coal which is stored in the bunker is sent into the mill,
through the conveyor belt which primarily controls the amount of coal
required to be sent to the furnace. It on reaching a rotating bowl in the
bottom encounters three grinding rolls which grinds it into fine powder
form of approx. 200 meshes per square inch. the fine coal powder along
with the heated air from the FD and PA fan is carried into the burner as
pulverized coal while the trash particles are rejected through a reject
system.
Types of coal pulverizers include:
 Impact

 Attrition

 Crushing
Sometimes these pulverizers employ all the three techniques all
together.

CLASSIFICATION OF MILLS

VERTICAL SPINDLE TUBE

BOWL/ PRESSURIZED
BALL & RACE

XRP E MILLS MPS


(BHEL) (BABCOCK)

87
Classification as per speed

The plant uses high speed bowl mills for crushing the coal.

Necessity of pulverizing the coal: The economic motives for the


introduction and development of pulverized fuel firing are:
i) Efficient utilization of cheaper low grade coals.
ii) Flexibility in firing with ability to meet fluctuating loads.
iii) Elimination of breaking losses.
iv) Better response to automatic control.
v) Ability to use high combustion air temperature for increasing the
overall efficiency of boiler.
vi) High availability.

v) Ability to burn a wide variety of coals.

Operating principle: The coal is to be ground is fed into the mill at or


near the centre of the revolving bowl. It passes between the grinding ring
in the revolving bowl and rolls as centrifugal force causes the material to
travel towards the outer perimeter of the bowl. The springs, which load
the rolls, impart the pressure necessary for grinding. The partially
pulverized coal continues up over the edge of the bowl.

88
Hot air enters the mill side housing below the bowl, is directed upward
past the bowl, into the deflector liners, then upward again into the
deflector openings at the top of the inner cone, then out through the
venturi and multiple port outlet assembly. As the air passes upward
around the bowl it picks up the partially pulverized coal. The lighter
particles are carried up through the deflector openings. The deflector
blades in the openings impart a spinning action to the material with the
degree of spin, set by the angle of opening of the blades, determining
the size of the finished product. Any oversize material is returned down
the inside of the inner cone to the bowl for additional grinding. When
pulverized to the desired extent, the pulverized fuel air mixture leaves
the mill and enters the piping system. Either constant airflow or variable
airflow methods are adopted. Any tramp iron or dense, difficult to grind
foreign material in the feed, if carried over the top of the bowl it drops out
through the air steam to the lower part of the mill side housing. Pivoted
scrapers attached to the bowl hub sweep the tramp iron or other material
around to the tramp iron discharge spout. The tramp iron spout is fitted
with a valve. Under normal operation, this valve remains open and
material is discharged into a sealed pyrite hopper. The valve is closed
only while the hopper is being emptied. Excessive spillage of coal with
rejects indicates that a mill is not functioning properly and remedial steps
should be taken as soon as possible to correct the situation. Normally
the causes for excessive spillage are a) Over feeding b) Too low a
journal spring pressure c) Too low airflow d) Too low a mill outlet
temperature e) excessively worn out grinding elements or improper mill
setting. The pulverizer operates under positive pressure, except the
suction mills. Seal air system provides clean air to a Chamber
surrounding seal and seal chamber to prevent hot air and coal dust from
escaping to the atmosphere or contaminating the gear bore lube oil.

89
Seal air is also supplied to each roller journal trunnion shaft to prevent
coal dust from entering the roller journal bearings.
Factors affecting the performance of the mill:
1. Size of the raw coal
2. Raw coal grind ability
3. Raw coal moisture content
4. Pulverized fuel fineness
5. Mill wear
6. Percentage ash in raw coal
The Bowl Mill is one of the most advanced designs of coal pulveriser
presently manufactured by BHEL. It possesses the following
advantages:
i) Low Power consumption.
ii) Reliability.
iii) Minimum maintenance and time required.
iv) Wide capacity with good turndown ratio
v) Ability to handle wide range of coals
vi) Quite and vibration less operation.
Design considerations:
a) Air temperatures up to 400 ° C can be used in these mills enabling the
mills to efficiently dry, grind and classify high moisture coals.
b) Expected wear surfaces are lined with removable type wear resisting
plates/ liners. Suitable access doors are available for easy replacement.
c) Undesirable foreign materials/ difficult to ground materials from coal
fall out and removed through tramp iron spout. This greatly reduces the
possibility of damage to mill parts.
d) Mill output can be raised from minimum to maximum in small
increments depending on boiler needs by varying the output of the
feeder and mill is sensitive to these variations in load. In order to obtain

90
rated capacity of the mill, it is necessary to have sufficient hot air
entering the mill to dry the coal and classifier deflector vanes set so as to
obtain the required fineness reasonably close to the value for which the
mills are designed.
e) Some size of mills is provided with built in lubrication system and
some size of mills with external lube oil system. However for all sizes of
mills the water cooler is fixed in the gear case, except for the HP series
of mills, where the cooler is also external. The journal bearings are
lubricated by oil filled in through the hole in the shaft. The oil level and
quality in the sump is to be maintained within the specified limits.
f) Sufficient journal spring pressure with not more than 0.5-mm clearance
between spring assembly head and journal head must be there to
achieve rated capacity at the required fineness. Because of space
limitation double coil springs are used, inner coil carrying approximately
25% of the total load, while the outer coil carries 75% of load. The
springs are wound in opposite direction to prevent possible interlocking
of the coils. Ring-roll clearances for efficient operation are obtained by
adjusting the stop bolts. If proper compression and ring-roll clearances
are not set, mill capacity reduces and the coal spillage increases.
g) Trunnion shaft supporting the journal assembly is mounted on
Trunnion shaft bushings. Rubber is bonded in between the two
concentric metal bearings and is capable of accommodating oscillating
motions, vibration etc. without wear or lubrication. Worm gear drive is
selected for bowl mills.
Bowl mill designation:
Suction type mills are designated as XRS whereas pressurized mills as
XRP and HP.
The nomenclature of each letter is as follows:
X - Frequency of power supply (50 cycles /sec)

91
R - Raymond, the inventor of bowl mills.
S - Suction type with exhauster coming after the mill
P - Pressurized type, with primary air fan coming before the mill.
H - High Performance mills.
The size of the mill is designated by the three numericals that follow the
above. For example, XRP 803 means, it is a Raymond Pressurized Bowl
Mill having the nominal bowl diameter of 80 inches with three numbers of
rollers grinding assemblies.
Constructional features:
a. Mill Drive and Bowl Assembly :
Mill Drive and Bowl Assembly consist of the main vertical shaft assembly
with Bearings, Worm gear, Worm shaft, Worm shat bearing etc.
Lubricant is maintained to the level of the centre line of the worm gear in
the Mill base. This lubricates the Bearings and Worm Gear- Worm shaft
in the Mill Base, when the Mill is in operation. The Bowl Assembly
consists of Bull Ring Assembly (Mounted on the Bowl), Skirt Scrapper
Assembly and vane wheel assembly (Attached to the Bowl). In
conventional design mills the fixed air guide vanes are provided in place
of rotating vane wheel assembly.
b. Mill Side and Liner Assembly :
The Hot Primary Air required for drying and carrying pulverized coal
enters the Mill, in the Mill side and air inlet housing. The Mill side and
Liner Assembly are insulated to prevent heat loss from primary air to the
atmosphere, or to the gearbox.
c. Separator Body Assembly :
The Separator body assembly consists of Journal Pressure Spring
Assemblies. Classifier Assembly and Deflector, Intermediate and Journal
Frame Liner Assemblies of Vane Wheel Assembly OR Separator body

92
liner separator bottom liners and air guide vanes of the conventional
design.
d. Roller Journal Assembly :
The Roller Assembly consists of Journal Shaft, Journal Bearings,
Journal Housings, Grinding Roll and Journal Head and Trunnion Shaft
Assembly and Vane Wheel Liners for Journal Head and Upper Journal
Housing. Three roller assemblies are there in a mill. Lub oil in the
Journal Assembly provides Stand Oil Lubrication for the bearings.
e. Mill Discharge Valve Assembly :
The Mill Discharge Valve Assemblies consists of four Multiport Outlet
and Mill Discharge Valves mounted on the multiple port outlet plate. Air
Cylinders operate the flaps in the Mill Discharge Valves. Solenoid Valves
and Limit Switches are provided to effect and indicate the open or close
position of the flap.
f. Coupling :
The Mill and Motor are coupled together by a flexible coupling. (Gear
Type or Bibby Type) for effecting the transmission from the motor to the
Mill. This type of coupling is also known as resilient coupling.
g. Tramp Iron Spout Assembly :
The Tramp Iron Spout Assembly consists of Tramp Iron Spout Body.
Tramp Iron Spout Adapter and Valve Gate. This assembly is mounted on
Mill base to guide the rejects from the Mill side and Liner Assembly to
pyrite Hopper assembly.
h. Pyrite Hopper Assembly :
The Pyrite Hopper Assembly consists of Pyrite Hopper Body and an
outlet valve, which is manually operated. The Pyrite Hopper Body will be
mounted with Tramp Iron spout Assembly. Using the outlet valve, the
rejects can be removed from Pyrite Hopper through a conveyor or wheel
barrow for every half an hour of mill operation. In a pressurized mill

93
before opening the Flap valve of Pyrite Hopper, the Tramp Iron Valve
should be closed to prevent hot primary air leaking into the atmosphere.
Specification of bowl mill:
Capacity 66.3T/Hr
Pulverizer Speed 600 RPM
Power 525 KW
Rolls 3
Coal 55 HGI, 14% Moisture
Fineness 70% thru 200 Mesh
Principle features of bowl mill:
 Grinding chamber
 Classifier mounted above it
 Pulverization takes place in rotating bowl
 Rolls rotating free on journal do the crushing
 Heavy springs provide the pressure between the coal and the rolls
 Rolls do not touch the grinding rings
 Tramp iron and foreign material discharged.

Internal and external features of a bowl mill


94
Seal air fan

Seal air fan is provided to mills (rollers and gear box) and feeders
(bearings) to prevent ingress of coal dust into area of application and to
protect the bearings from coal particle deposition. Suction of Seal air fan
is taken from PA fan discharge. It is located at 0 meter in boiler area.

Internal view of a bowl mill

95
Air System

The mill produces Pulverized coal 80% of which passes through 200
mesh. Primary air mixed with Pulverized coal (PF) is carried to the coal
nozzle in the wind box assembly. PF from coal nozzle is directed
towards the centre of boiler burning zone. Pre-heated secondary air
enters boiler and surrounds the PF and help in combustion. The primary
air is supplied by Primary Air (PA) fan and the secondary air is supplied
by Forced Draft (FD) fan. Also to dispose the flue gases into the
atmosphere and to maintain a negative pressure, for combustion, within
the boiler furnace an Induced Draft (ID) fan is employed. A fan is
capable of imparting energy to the air/gas in the form of a boost
in pressure. The boost is dependent on density for a given fan at
a given speed. The higher the temperature, the lower is
the boost. Fan performance (Max. capability) is represented as volume
vs. pressure boost.

The basic information needed to select a fan is:

 Air or Gas flow (Kg/hr).


 Density (function of temperature and pressure).
 System, resistance (losses).
Classification of Fans
In boiler practice, we meet the following types of fans.
 Axial fans: I n t h i s t yp e t h e mo ve me n t o f a i r o r g a s i s
p a r a l l e l t o i t s e xi t o f rotation. These fans are better suited to
low resistance applications. T h e a x i a l f l o w f a n u s e s t h e
s c r e w l i k e a c t i o n o f a m u l t i p l i e d rotating shaft, or
propeller, to move air or gas in a straight through path. Here both

96
the axes inlet air and outlet air flow are parallel to the axis of the
fan.

Axial fan

 Centrifugal (Radial) fans: This fan moves gas or air perpendicular


to t h e a xi s o f r o t a t i o n . T h e r e a r e a d va n t a g e s wh e n t h e
a i r mu s t b e moved in a system where the frictional resistance is
relatively high. The blade wheel whirls air
c e n t r i f u g a l l y b e t w e e n e a c h p a i r o f blades and forces it
out peripherally at high velocity and high static pressure. More air
is sucked in at the eye of the impeller. As the air leaves the
revolving blade tips, part of its velocity is converted into additional
static pressure by scroll shaped housing. Here the axis of the inlet
air is parallel to the fan axis and that of the outlet air is
perpendicular to the fan axis.

Radial fan

97
Classification of blades

There are three types of blades:


 Backward curved blades.
 Forward curved blades.
 Radial blades.
Fans used in Thermal Power Plant
Usually, there are three fans used in any thermal power plant. They are:

1. Induced draught fan: The induced Draft Fans are generally of Axial -
Impulse Type. Impeller nominal diameter is of the order of 2500 mm.
The fan consists of the following sub-assemblies:
 Suction Chamber or housing
 Inlet Vane Control or Inlet dampers
 rotor with two sleeve bearings
 Outlet Guide Vane Assembly
 Shaft seal
There are two induced draught fans per boiler, both operating. In 500
MW fans are single-stage, double-inlet centrifugal fans (NDVZ type). The
outlet guides are fixed in between the c a s e o f t h e d i f f u s e r a n d t h e
c a s i n g . Th e s e g u i d e va n e s s e r ve t o direct the flow axially and to
stabilize the draft-flow caused in the i m p e l l e r . Th e s e o u t l e t b l a d e s
a r e r e m o va b l e t y p e f r o m o u t s i d e . During operation of the fan
itself these blades can be replaced one by one. Periodically, the outlet
blades can be removed one at a time to find out the extent of wear on
the blade. If excessive wear is noticed the blade can be replaced by a
new blade. The inlet dampers can be adjusted externally. The rotor
consists of a hollow shaft with an impeller joined by means of a flange.
The fan housing is sealed at the shaft passage to the outside by means
of labyrinth seals. The rotor is placed between oil-lubricated sleeve

98
bearings. The fan is adapted to ten changing operating conditions by
varying the speed of the fan and also by adjustable inlet dampers
arranged in the front of the impeller on either side. The main purpose of
an ID fan is to suck the flue gas through all the above mentioned
equipments and to maintain the furnace pressure. ID fans use 1.41% of
plant load for a 500 MW plant. It also maintains the furnace draft.

An ID fan

ID fan specifications

Fan type: NDZV 47 S No. of boilers: Two

Medium: Flue Gas Temperature: 150°c

Capacity: 587m3/s Total head: 490mmwc

Density: 0.793 kg/m3 Speed: 545 rpm

Coupling: REYNOLDS Fan Regulation: VFD & IGV

Motor Rating: 4000 kW

99
ID fan designation
NDZV 47 S
Here NDZV implies Radial Double Suction simply supported
47 implies Impeller Tip diameter in decimeter
S implies Type of Impeller
2. Forced draught (FD) fan: There are two FD fans per boiler. T h e f a n ,
n o r ma l l y o f t h e s a me t yp e a s I D F a n , c o n s i s t s o f t h e
following components:
 Suction bend
 Inlet housing
 Fan housing
 Main bearings (anti-friction bearings)
 Impeller with adjustable blades and pitch control mechanism
 Guide vane casing with guide vanes
 Diffuser.
The centrifugal and setting forces of the blades are taken up by
the blade bearings. The blade shafts are placed in combined radial and
axial antifriction bearings which are sealed off to the outside. The angle
of-incidence of the blades may be adjusted during operation. T h e
characteristic pressure volume curves of the fan may
be c h an g e d in a la r g e r a ng e wi t h o u t e ss e n ti a l l y
modifying the efficiency. The fan can then be
e a s i l y a d a p t e d t o c h a n g i n g operating conditions.

An FD fan

100
The rotor is accommodated in cylindrical roller bearings and an
inclined ball bearing at the drive side adsorbs the axial thrust. An oil-
hydraulic servo motor (also known as a power cylinder) flanged to the
impeller and rotating with it adjusts the blades during operation
lubrication and cooling these bearings is assured by a combined
oil level and circulating lubrication system. Turbine oil with a viscosity of
61.2 – 74.8 mm2/sec at 400C is employed.

FD fan Specifications
Fan type: AP1-26/16 No. of boilers: Two
Medium: Atmospheric Air Capacity: 267m3/s
Total head: 410mmwc Density: 1.060 kg/ m3
Speed: 980 rpm Coupling: Spacer Type
Fan regulation: Blade Pitch Control Motor rating: 1430 kW
Volts: 3300 volt

101
The forced draft fans, also known as the secondary air fans are used to
provide the secondary air required for combustion, and to maintain the
wind box differential pressure. The features of the FD fans are: axial
flow, single stage, impulse fan. FD fans use 0.36% of plant load for a
500 MW plant.
FD fan designation:
The model no. of the FD fan used at NTPC Simhadri is AP1 26/16,
where A refers to the fact that it is an axial flow fan, P refers to the fan
being progressive, 1 refers to the fan involving a single stage, and the
numbers 26 and 16 refer to the distances in decimeters from the centre
of the shaft to the tip of the impeller and the base of the impeller,
respectively. Similar designation is followed for PA fans.

3. Primary air (PA) fan: There are two primary air fans per boiler. The fan
consists of the following components:
 Suction bend
 Fan housing with guide vanes (stage 1)
 Main bearings (anti-friction bearings)
102
 Rotor, consisting of shaft, impellers with adjustable blades and
pitch control mechanism.
 Guide vane housing with guide vanes.
 Diffuser
On its impeller side, the suction bend is designed as an inlet nozzle.
Guide vanes of axial flow type are installed in the fan and guide vane
housings, in order to guide the flow. Suction bend and diffuser are
connected to the fan housing via expansion joints. The fan is driven from
the inlet side.
The centrifugal and setting forces of the blades are taken up by
the blade bearings. The blade shafts are placed in combined radial and
axial antifriction bearings which are sealed off to the outside. The angle
of-incidence of the blades may be adjusted during operation.
The rotor is accommodated in cylindrical roller bearings and an
inclined ball bearing at the drive side adsorbs the axial thrust. An oil-
hydraulic servo motor (also known as a power cylinder) flanged to the
impeller and rotating with it adjusts the blades during operation
Lubrication and cooling these bearings is assured by a combined
oil level and circulating lubrication system. Turbine oil with a viscosity of
61.2 – 74.8 mm2/sec at 400C is employed.
PA fan has a flange mounted design, single stage suction, NDFV
type, backward curved bladed radial fan and operates on the principle of
energy transformation due to centrifugal forces. Some amount of
the velocity energy is converted to pressure energy in the spiral
casing. The fan is driven at a constant speed
a n d t h e f l o w i s controlled by varying the angle of the inlet vane
control. The special feature of the fan is that is provided with inlet
guide vane control with a positive and precise link mechanism. The
primary air fans are used to carry the pulverized coal particles from the
103
mills to the boiler. They are also used to maintain the coal-air
temperature. The specifications of the PA fan used at the plant under
investigation are: axial flow, double stage, reaction fan. A PA fan uses
0.72% of plant load for a 500 MW plant.

A PA fan

PA fan Specifications

Fan type: AP2-20/12 No. of boiler: Two

Medium: Atmospheric Air Capacity: 186m3/s

Total head: 1195mmwc Density: 1.060 kg/ m3

Speed: 1480 rpm Coupling: Spacer Type

Fan regulation: Blade Pitch Control Motor rating: 2800 kW

Volts: 11000 volt

104
Air Pre heater

Air pre heater absorbs waste heat from the flue gases and transfers
this heat to incoming cold a i r , b y me a n s o f c o n t i n u o u s l y
r o t a t i n g h e a t t r a n s f e r e l e me n t o f specially formed metal plates.
Thousands of these high efficiency elements are spaced and
compactly arranged within 12 sections. Sloped compartments of
radially divided cylindrical shell called the rotor. The housing
surrounding the rotor is provided with duct c o n n e c t i n g b o t h t h e
e n d s a n d i s a d e q u a t e l y s c a l e d b y r a d i a l a n d circumferential
scaling.

Location and Functioning of an air pre heater

Air pre heaters can further be classified as:


 Primary air pre heater (size: 27.5)
 Secondary air pre heater (size: 30)

105
Air pre heater is a general term to describe any device designed to heat
air before another process (for example combustion in a boiler). It is a
heat transfer surface in which air temperature is raised by transferring
heat from other medium such as flue gas. The purpose of the air pre
heater is to recover the heat from the flue gas from the boiler to improve
boiler efficiency by burning fuel with warm air which increases
combustion efficiency, and reduces useful heat lost from the flue. As a
consequence, the gases are sent to the chimney or stack at a lower
temperature (to meet emission norms, for example) allowing simplified
design of the ducting and stack.
APH is the last heat exchanger in the boiler flue gas circuit. To achieve
maximum boiler efficiency maximum possible useful heat must be
removed from the gas before it leaves the APH. However certain
minimum temperature has to be maintained in the flue gas to prevent
cold end corrosion.
Functions:
An air pre-heater heats the combustion air where it is economically
feasible. These are used for pre-heating the primary and secondary air
before entering the furnace.

The pre-heating helps the following:


 Igniting the fuel.
 Improving combustion.
 Drying the pulverized coal in pulverizer.
 Reducing the stack gas temperature and increasing
 The boiler efficiency.
Advantages:
1. Increase in boiler efficiency.
2. Stability of combustion increases by use of hot air.

106
3. Intensify and improved combustion. Intensified combustion permits
faster load variation and fluctuation.
4. Permitting to burn poor quality of coal.
5. High heat transfer rate in the furnace and hence lesser heat
transfer area requirement.
6. Less un burnt fuel particle in flue gas thus combustion and both
efficiency is improved.
In the case of pulverised coal combustion, hot air can be used for
heating the coal as well as for transporting the pulverised coal to
burners. This being a non-pressure part will not warrant shutdown of unit
due to corrosion of heat transfer surface which is inherent with lowering
of flue gas temperature.
Types:
1. Recuperative type
a. Tubular air heater
b. Plate type air heater

2. Regenerative type
a. Ljungstrom type
b. Rothemuhle type

The APH used at NTPC Simhadri is a Ljungstrom regenerative type


APH.
Construction:
Air Pre heater consists of:
 Connecting plates
 Housing
 Rotor
 Heating surface elements
107
 Bearings
 Sector plates and Sealing arrangement
In this design, the whole air pre heater casing is supported on the boiler
supporting structure itself with necessary expansion joints in the ducting.
The vertical rotor is supported on thrust bearings at the lower end and
has oil bath lubrication. Oil in bath is cooled by water circulating in coils
inside a cooler. The top end of the rotor has a simple roller bearing to
hold the shaft in a vertical position.

Guide Bearing Assembly Support Bearing Assembly

The rotor is built up on the vertical shaft with radial supports and cages
for holding the baskets in position. Radial and circumferential seal plates
are also provided to avoid leakages of gases or air between the sectors
or between the duct and the casing while in rotation. Air pre heater
baskets elements are made up of zigzag corrugated plates pressed into
a steel basket giving sufficient annular space in between for the gas to
pass through. These plates are corrugated to give more surface area per
108
unit mass for efficient heat transfer and also to give it the rigidity for
stacking them into the baskets.

Radial seal
The Heating Elements used are Hot End Baskets, Hot Intermediate
Baskets and Cold End Baskets. The material used for Cold end in the
basket is a special type of steel (corten steel (trade name)) which has
high resistance to the low temperature sulphur corrosion, thus
prolonging operational life. In the hot end mild steels are used. The

109
optimal geometric shape is usually corrugated and sizes are
determined based on design modeling and experimental data. The
turbulence of air and gas flow through the package increases the heat
transfer rate.

Arrangement of Heating Elements

The air pre heater is rotated by means of an electric drive motor through
a rack and a pinion. The power from the motor is transmitted via a shaft
to the rack and then the pinion. The power from the pinion is transmitted
to the rotor assembly of the APH through another shaft. In case, the
electric motor fails an air motor is used in its place which is driven by
compressed air from the compressor house. The air motor can be put up
to 3 hrs of service as a temporary drive till the electric motor is repaired.

A Regenerative air pre heater 110


Ljungstrom Regenerative Air Pre heater

Working:
A regenerative type air pre-heater absorbs waste heat from flue gas and
transfers this heat to the incoming cold air by means of continuously
rotating heat transfer elements of specially formed metal sheets. In other
words, the flue gas flows through a closely packed matrix with
consequent increase in matrix temp. And subsequently air is passed
through the matrix to pick up the heat. A bi-sector APH preheats the
combustion air. Thousands of these high efficiency elements are spaced
and compactly arranged within sector shaped compartments of a radially
divided cylindrical shell called the rotor. The housing surrounding the
rotor is provided with duct connections at both ends, and is adequately
sealed by radial and axial sealing members forming an air passage
through one half of the APH and a gas passage through the other. The
rotor itself is the medium of heat transfer in this system, and is usually
composed of some form of carbon steel structure. As the rotor slowly

111
revolves the elements alternately pass through the air and gas
passages; heat is absorbed by the element surfaces passing through the
hot gas stream, then as the same surfaces pass through the air stream,
they release the heat to increase the temperature of the combustion of
process air. It rotates quite slowly in order (around 1-5 RPM) to allow
optimum heat transfer first from the hot exhaust gases to the element,
then as it rotates, from the element to the cooler air in the other sectors.
During initial startup of the boiler flue gases are not readily produced but
it is required to pre heat the air hence special air pre heaters called
Steam Cold Air Pre heaters (SCAPH) are used. These air pre heaters
use auxiliary steam to pre heat the incoming air into the boiler during
initial start up. Once, combustion in the boiler takes place flue gases are
released which are diverted to APHs for preheating of air.

112
Working of an air pre heater

Advantages of Ljungstrom Regenerative Air Pre heater:

 Significant reduction in overall size and weight.


 Easy and economic replacement of heating surface with separate
cold end and hot end packs.
 Min. metal temp. at cold end is higher. This metal temp. oscillates
some 20-22ºC above and below mean of air entering temp. and gas
exit temp.
Problems:
 High Air leakages resulting high fan power.
 Dust carry over to furnace is high causing ash erosion of boiler tubes
in burner panels.
 Baskets are subjected to abrasive wear, hence frequent replacement
of the baskets are called for
 Prone to air heater fire, the problem is aggravated during oil firing
APH Performance:
 Higher than expected leakage would decrease the condition of
improved working.
 Higher inlet flue gas temperature is rather rare, but this could be one
reason for high exit temperature.
 Optimum flue gas temperature is required for effective ESP
performance
 Unequal temperature at air heater exit should be investigated.
113
Performance of APH may be degraded due to the following reasons:
Seal Leakage, Erosion, Corrosion, High Press Drop Across APH, APH
Fire.

APH Specifications
Number of air pre heater per unit: 2
Heater size: 27-VI-(T)-74” casing
2
Approx heating surface: 19000 m each
Rotor drive motor: 15 H.P.
Speed reduction ratio: 110:1
Approx oil capacity: 13 Gallons
Solenoid drive: electrical & air motor

Mechanism: rack & pinion


HEATING ELEMENTS
Hot end: carbon steel du type
Hot intermediate: carbon steel du type
Cold end: Corten steel nf type
Value 110 V, A.C

Ai r cir cul ati on S ystem Ar rangement:


P r i m a r y a i r s y s t e m : Ambient air is drawn into the primary air
ducting by two 50% duty, motor driven axial reaction fans. Air
discharging from each fan is divided into two parts, one passes first
through an air pre-heater then through a gate into the P.A bus duct. The
second goes to the cold air duct. The mix of both is used to carry the
pulverized coal to the boiler.
Secondary air system: Ambient air is drawn into the secondary air
system by two 50% duty, motor driven axial reaction forced draft fans

114
with variable pitch control. Air discharging from each fan passes first
through an air preheated then through an isolating damper into the
secondary air bust duct. The cross over duct extends around to each
side of the boiler furnace to form two secondary air to burner ducts. At
the sides of the furnace, the ducts split to supply air to two corners. Then
split again to supply air to each of nineteen burner/air nozzle elevations
in the burner box.

Primary and secondary air systems


Energy Losses in the boiler

 Heat loss from furnace surface.


 Unburned carbon losses.
 Incomplete combustion losses.
 Loss due to hot ash.
 Loss due to moisture in air and fuel.
 Loss due to combustion generated moisture.
 Dry Exhaust Gas Losses.

115
Overview of air system

Arrangement of Boiler Auxiliaries


116
TURBINE MAINTAINANCE
DEPARTMENT

117
Steam Turbine theory
A steam turbine is a mechanical device that extracts thermal energy
from pressurized steam, and converts it into useful mechanical work.
Here steam expands from high pressure to low pressure. The steam
turbine is a form of heat engine that derives much of its improvement in
thermodynamic efficiency from the use of multiple stages in the
expansion of the steam.

Basic operation of a Steam turbine

Characteristics of a Steam turbine:

 It can be operated from <1 MW to >1300MW

 High-pressure steam flows through the turbine blades and turns the
turbine shaft.

 The shaft of the turbine is coupled to the generator shaft to produce


electricity.

 Power output is proportional to the steam pressure drop in the


turbine.

118
Operating Principle:

A steam turbine’s two main parts are the cylinder (casing) and the rotor.
As the steam passes through the fixed blades or nozzles it expands
and its velocity increases. The high-velocity jet of steam s t r i k e s
t h e f i r s t s e t o f m o vi n g b l a d e s . T h e k i n e t i c e n e r g y o f t h e
steam changes into mechanical energy, causing the shaft to rotate. The
steam then enters the next set of fixed blades and strikes the
next row of moving blades. As the steam flows through the turbine, its
pressure and temperature decreases, while its volume increases. The
decrease in pressure and temperature occurs as the steam
transmits .energy to the shaft and performs work. After passing
through the last turbine s t a g e , t h e s t e a m e x h a u s t s i n t o t h e
c o n d e n s e r o r p r o c e s s s t e a m system. The kinetic energy of
the steam changes into mechanical erringly through the impact
(impulse) or reaction of the steam against the blades.

Turbine classification
Based on the principle of action of steam turbines nay be classified as:
Impulse Turbine:
In Impulse Turbine steam expands in fixed nozzles. The high velocity
steam from nozzles does work on moving blades which causes the
shaft to rotate. The essential features of impulse t u r b i n e a r e
that all pressure drops occur at nozzles and not
o n blades. This is obtained by making the blade passage of constant
cross-section area. A simple impulse turbine is not very efficient
because it does not fully use the velocity of the steam. Many impulse
turbines are velocity compounded. This means they have two or
more sets of moving blades in each stage. A single-stage impulse

119
turbine is known as the de Laval turbine. Tip leakage is a major problem
in an impulse turbine. For higher efficiency, twisted (or warped) blades
are used in the later stages of the turbine. Steam velocity can be
maximized by having maximum pressure drop in the nozzles. Hence in
100% Impulse steam Turbine, whole pressure drop will be in stationary
blades or nozzles. To sustain high velocity impulse stage should be very
robust in construction.

Reaction Turbine:
In this type of turbine pressure is reduced at both fixed & m o v i n g
blades. Both fixed& moving blades act as nozzles.
T h e e xp a n s i o n o f s t e a m t a k e s place on moving blades. A
reaction turbine uses the "kickback" force of the s t e a m a s i t
l e a ve s t h e m o vi n g b l a d e s a n d fi xe d b l a d e s h a ve t h e s a m e
shape and act like nozzles. Thus, steam expands,
l o o s e s pressure and increases in velocity as it passes through both
sets of blades. The pressure drop suffered by steam while passing
through moving blades causes additional conversion of pressure energy
into kinetic energy within these blades, thus giving rise to reaction and
adding to the propelling force. The blade passage cross-sectional area is
varied (converging type). All reaction turbines are pressure-
compounded turbines. A 100% Impulse or Reaction stage is purely a
theoretical assumption not practically feasible.
Parson’s turbine is a special reaction turbine in which equal enthalpy
drops occur in the fixed and moving blades.
In a reaction turbine, with reduction of inlet pressure, specific volume
increases, thus also increasing the volume flow rate, thereby requiring
increased flow area. This requires increased blade height and mean

120
wheel diameter. For higher efficiency, twisted (or warped) blades are
used in the later stages of the turbine.

Steam turbines may also be classified into the


following categories:
According to the direction of steam flow
 Axial turbines
 Radial turbines
According to the steam conditions at
inlet to turbines
 Low-pressure turbines
 Medium -pressure turbines
 High-pressure
 Turbines of very high pressures

121
 Turbines of supercritical pressures
According to their usage in industry
 T u r b i n e s wi t h c o n s t a n t s p e e d o f r o t a t i o n p r i ma r i l y
u s e d f o r driving alternators.
 Steam turbines with variable speed meant for
d r i v i n g t u r b o blowers, air circulators, pumps etc.
 Turbines with variable speed: Turbines of this type are usually
 e mp l o ye d i n s t e a me r s , s h i p s a n d r a i l wa y l o c o mo t i ve s
( t u r b o locomotives)
Compounding:
In a steam turbine, if steam is allowed to expand in a single row of
nozzle, the velocity at exit from the nozzles is very large.
Subsequently, the rotational speed of the turbine can be high, in
the range of 30,000 rpm. Such high rotational speeds cannot be
properly utilized due to friction losses, centrifugal stresses, and
energy losses at exit. Therefore, steam turbines are
compounded by expanding the steam in a number of stages.
Following are the types of compounded turbine:
 Velocity Compounded Turbine:
Like simple turbine it has only one set or row of nozzles & entire
steam pressure drop takes place there. The kinetic energy of steam on
the nozzles is utilized in moving the blades. The role of fixed blades is to
change the direction of steam jet & to guide it.
 Pressure Compounded Turbine:
This is basically a no. of single impulse turbines in series or on the same
shaft. The exhaust of first turbine enters the nozzle of the next
turbine. Total pressure drop of steam does not take on first

122
nozzle ring but divided equally on all of them. The pressure drop
occurs only in the nozzles, not in the moving blades.

Pressure Compounding of a steam turbine

 Pressure Velocity Compounded Turbine:


It is just the combination of the two compounding has the advantages
of allowing bigger pressure drops in each stage & so f e we r
s t a g e s a r e n e c e s s a r y. He r e f o r g i ve n p r e s s u r e d r o p t h e
turbine will be shorter length but diameter will be increased.

123
Velocity compounding of a Steam Turbine

The turbine cycle


Fresh steam from boiler is supplied to the turbine through the
emergency stop valve. From the stop valves steam is supplied to
control valves situated on HP cylinders on the front bearing end.
After expansion through 12 stages at the HP cylinder steam flows back
to boiler for reheating and reheated steam from t h e b o i l e r
c o ve r t o t h e i n t e r m e d i a t e p r e s s u r e t u r b i n e t r o u g h t wo
i n t e r c e p t o r va l ve s a n d f o u r c o n t r o l va l ve s m o u n t e d o n t h e
I P turbine.
After flowing trough IP turbine steam enters the middle part of the LP
turbine through cross over pipes. In LP turbine the exhaust steam
condenses in the surface condensers welded directly to the exhaust part
of LP turbine.
The selection of extraction points and cold reheat pressure has been
done with a view to achieve the highest efficiency. These are two
extractions from HP turbine, four from IP turbine and o n e f r o m
LP turbine. Steam at 1.10 to 1.03 g/cm2 (abs) is
supplied for the gland sealing. Steam for this purpose is

124
obtained f r o m d e a e r a t o r t h r o u g h a c o l l e c t i o n wh e r e
p r e s s u r e o f s t e a m i s regulated.
From the condenser condensate is pumped with the help of 3x50%
capacity condensate pumps to deaerator through the low pressure
regenerative equipments.
Feed water is pumped from deaerator to the boiler through the HP
heaters by means of 3x50% capacity feed pumps connected before the
HP heaters.

The Turbine Cycle

Governing of Steam Turbines


Fundamentally governing means to control the output of the turbine by
varying the inlet steam flow by means of throttling valves of the turbine.
The valves are controlled by the governor.
The basic functions of Turbine governing are:

125
1. Safe start up & shut down of machine
2. To change the output of the machine as per requirement
3. To protect the machine from damage
4. To protect the machine from over speeding during load throw off
5. To control speed and load on the turbine (operation of control
valves)
6. To ensure safety of the turbine under unacceptable operating
conditions (operation of emergency stop valves and NRVs)
Types of governing
 Throttle governing: In throttle controlled turbines, steam flow is
controlled by opening and closing of all the control valves
simultaneously to the extent required by load and admitting the
steam to the group of nozzles located on the entire periphery.
 Nozzle governing: In nozzle controlled turbines, steam flow is
controlled by sequential opening or closing of control valves allowing
steam to flow to associated nozzle groups.
Types of governing systems
The governing system can be one of the following types:
• Mechanical: In mechanical governing system, the speed
transducer is a mechanical centrifugal type speed governor, which
actuates control valves through mechanical linkages. Currently,
purely mechanical governing systems for utility turbines are
obsolete.

• Hydro-mechanical: In hydro-mechanical governing system, speed


transducer is usually mechanical centrifugal type speed governor.
It is connected to hydraulic system either hydraulically or
mechanically. In hydraulic system, signal is amplified so that
control valve servomotors can be actuated.

126
• Hydraulic: In hydraulic governing system, speed transducer is a
centrifugal pump, whose discharge pressure is proportional to
square of speed. This signal is sent to hydraulic converter /
transformer which generate a signal proportional to valve opening /
closure required. Before applying the signal to control valve
servomotors, the same is suitably amplified
• Electro-hydraulic: This system provides very good combination
of electrical measuring & signal processing and hydraulic controls.
It offers many advantages over other three types of governing
systems and is popular in large steam turbine units due to growing
automation of turbine and generator sets.

Thus the individual TG governing system imply a need to

 withstand a full load rejection safely

 Provide appropriate contributions to system frequency control.

127
Turbine and its auxiliaries
The Main turbine
The 500MW turbines is predominantly of reaction-condensing- tandem-
compound, three cylinder- horizontal, disc and diaphragm, reheat type
with throttle governing and regenerative system of feed water heating
and is coupled directly with A.C. Generator. The turbine is suitable for
sliding pressure operation to avoid throttling losses at partial loads. It
c o mp r i s e s o f s e p a r a t e HP , I P a n d L P c yl i n d e r s , wh o s e
r o t o r s a r e mo u n t e d o n a s i n g l e s h a f t . Th e HP t u r b i n e i s a
s i n g l e c yl i n d e r a n d comprises of 18 stages whereas the IP and LP
turbines re double flow cylinders having 12 stages & 6 stages
respectively. The individual turbine rotors and the Generator rotor are
connected by rigid couplings. The HP & IP turbine rotor are rigidly
compounded & IP rotor by lens type semi flexible coupling. All the
three rotors are aligned on four bearings of which the bearing no.2 is
combined with thrust bearing.
The main superheated steam branches off into two streams from
the boiler and passes through four combined emergency stop
valve (main stop valves) and control valves by a
simple throttle governing system, before entering the
g o v e r n i n g w h e e l chamber of the HP turbine. After expanding
in the 12 stages in the HP turbine the steam returned in the boiler for
reheating. On the two exhaust lines of HP turbine, swing check valves
are provided to prevent hot steam from the re heater flowing back into
the HP turbine.
The reheated steam from the boiler enter IP turbine via interceptor
valves and control valves and after expanding enters the LP
turbine stage via 2 numbers of cross over pipes.

128
In the LP stage the steam expands in axially opposite direction to
counteract the trust and enters the condenser placed d i r e c t l y
below the LP turbine. The cooling water flowing
throughout the condenser tubes condenses the steam
a n d t h e condensate collected in the hot well of the condenser.
The condensate collected is pumped by means of 3x50% duty
condensate pumps through LP heaters to deaerator f r o m
where the boiler feed pump delivers the water to
boiler t h r o u g h H P h e a t e r s t h u s
f o r m i n g a c l o s e d c y c l e .

A 500 MW Steam Turbine (Cross-sectional view)

HP Turbine

The outer casing of the HP turbine is of the barrel type, which prevents
mass accumulation with high thermal stresses, and has neither axial nor
a radial flange. Barrel-type casing permits quick startup and high rate of
change of load. The guide blade carrier is axially split and kinematically
supported. The space between the outer casing and the inner casing is
129
fed from admission steam to HP turbine. This steam is drained through
HP casing during start up which promotes quicker heating of inner
casing which results in lesser problems of differential expansion. The
inner casing is attached in the horizontal and vertical planes in the barrel
casing so that it can freely expand radially in all directions and axially
from a fixed point (HP- inlet side). The HP turbine is provided with a
balance piston in the admission side to counter act the axial thrust
caused by steam forces. HP turbine is provided with 18 stages of
reaction blades. The HP casing is made of creep resisting Chromium-
Molybdenum-vanadium (Cr-Mo-V) steel casing. The steam chests which
accommodate the control valves are also made of the same material in
the form of castings. The HP rotor is machined from single Cr-Mo-V steel
forging with integral discs. The blades are attached to their respective
wheels by ‘T’ root fastenings. In all the moving wheels, balancing holes
are also machined to reduce the axial thrust. The HP turbine rotor is also
fitted with a balancing drum to eliminate the axial thrust.

A HP turbine

130
Characteristics of a HP turbine

• Single flow

• double shell casing

• Inner casing : Vertically split


• Outer casing: Barrel type
• Single exhaust in L/H

• Mono block rotor

• Reaction blading with integral shroud

• Rigid coupling

• Casing mounted valves

• Transported as single unit

IP Turbine

It is of double flow construction and consists of two casinos. Both are


axially split and the inner casing kinematically supported and carries the
guide blades. The inner casing is attached to the outer casing in such a
manner as to be free to expand axially from a fixed point and radially in
all directions. IP turbine has 12 stages per flow. The IP turbine casing is
made of two parts. The front part is made of creep resisting Chromium-
Molybdenum-Vanadium steel casings and the exhaust part is of steel
fabricated structure. The two parts are connected by a vertical joint. The
control valves of IP turbine are mounted on the casing itself. In an IP
turbine the nozzle boxes are cast integral with the casing itself. The IP
rotor has seven discs integrally forged with rotor while the last four discs

131
are shrunk fit. The shaft is made of high creep resisting Cr-Mo-V steel
forgings. The blades on the integral discs are secured by ‘T’ root
fastenings while on shrunk fit disc by ‘fork root’ fastenings. It provides
opposed double flow in the two blade sections and compensates axial
thrust. Steam after reheating enters the inner casing from Top & Bottom.
Outer casing is subjected to only low pressure and low temperature
conditions

An IP Turbine

An IP turbine
Cross sectional view of an IP
turbine 132
Characteristics of IP turbine

• Single / double flow

• Double shell casing

• Horizontally split
• Two exhaust in L/H

• Mono block rotor

• Reaction blading

• Rigid coupling

• Usually transported as single unit

LP Turbine

The casing of the double-flow LP cylinder is of three-shell design. The


shells are axially split and of rigid welded construction. The inner shell
taking the first row of guide blades is attached kinematically in the middle
shell. Independent of the outer shell, the middle shell, is supported at
four points on longitudinal beams. LP turbine is provided with 6 reaction
stages/flow. The LP turbine rotor consists of shrunk fit discs mounted on
a shaft. The shaft is a forging of Cr-Mo-V steel while the discs are of high
strength nickel steel forgings. Blades are secured to the respective discs
by riveted fork root fastenings. The LP turbine casing consists of three
parts i.e. one middle part and two exhaust parts. The three parts are
fabricated from weld able mild steel. The exhaust casings are bolted to
the middle casings by a vertical flange. The casings are divided in the
horizontal plane through the turbine centre line.

133
Steam enters the middle casing from top and then divides into twp
equal, axially opposed flows, to pass through four stages. The last but
one stage on each side is ‘Baumann’s stages’. They expand a part of
the steam down to the condenser pressure and allow rest of the steam
to expand through the last stages. To protect the IP cylinder against
excessive internal pressure, four atmospheric relief valves are provided
in the exhaust hoods. Each valve assembly has 1 mm thick gasket ring
clamped between valve seats and valve disc. If due to some reasons the
pressure at exhaust hood rises to 1.2 abs, then the valve disc tries to lift
and thereby rupture the gasket ring, thus allowing the steam to exhaust
into the atmosphere in the turbine hall

Characteristics of an LP turbine

• Double flow

• Three shell casing

• Horizontally split

• Mono block rotor

• Reaction blading

• Rigid coupling

134
An LP turbine

Cross-sectional view of an LP An LP turbine


turbine

135
Blading

The entire turbine is provided with reaction blading. The guide blades
and moving blades of the HP and IP parts and the front rows of the LP
part with inverted T-roots and shrouding are milled from one piece. The
last stages of the LP part consists of twisted, drop-forged moving blades
with fir tree roots inverted in corresponding grooves of the rotor and
guide blade rows made of sheet steel.

Bearings

The HP turbine is supported by two bearings, a journal bearing at the


front end of the turbine and a combined journal and thrust bearing
directly adjacent to the coupling with the IP rotor. The IP and LP rotors
have a journal bearing each at the end of the shaft. The thrust bearing
takes up residual thrust from both the directions. The bearing
temperatures are measured by thermocouples. No of general bearing
are 6 and the no of thrust bearing are 1. These Bearings are usually
forced lubricated and have provision for admission of jacking oil. The
function of the journal bearing is to support the turbine rotor. The journal
bearing consists of the upper & lower shells, bearing cap, spherical
block, spherical support and key. The bearing shells are provided with a
Babbitt face. Bearing is pivot mounted on the spherical support to
prevent the bending movement on the rotor. A cap which fits in to the
corresponding groove in the bearing shell prevents vertical movement of
the bearing shell. The bearing shells are fixed laterally by key. Each key
is held in position in the bearing pedestal by two lateral collars. The
Temperature of the bearings at every instant is monitored. Upper and
lower shell can be removed without the removal of Rotor. To do this
shaft is lifted slightly by means of jacking device but within the clearance

136
of shaft seal. The lower bearing shell can be turned upward to the top
position and removed. The thrust bearing is normally Mitchell type and is
usually combines with a journal bearing, housed in spherically machined
steel shell. The bearing between the HP and IP rotors is of this type,
while the rest are journal bearings.
Sealing glands
To eliminate the possibility of steam leakage to atmosphere from the
inlet and exhaust ends of the cylinder, labyrinth glands of the axial
clearance type are provided which provide a trouble free frictionless
sealing. These glands seal the steam in the cylinders against
atmosphere.
Each gland sealing consists of a number of thin sealing strips which in
the HP and IP parts are alternatively caulked into grooves in the shafts
and surrounding sealing rings. The sealing strips in the LP part are only
caulked into the sealing rings. These rings are split into segments which
are forced radially against a projection by helical springs and are able to
yield in the event of rubbing.

Labyrinth seal glands


137
Emergency Stop Valves and Control Valves
The turbine is equipped with emergency stop valves to cut off steam
supply and with control valves to regulate steam supply. Emergency
Stop Valves (ESV) are provided in the main stream line and the
interceptor valves (IV) are provided in the hot reheat line.
Emergency stop valves are actuated by servomotor controlled by the
protection system. ESV remains fully open or fully close. The stop valves
are spring- operated single-seat type. Control valves are actuated by the
governing system through servomotors to regulate steam supply as
required by the load. Valves are single seat type.
The HP turbine is equipped with four initial steam stop and control
valves. A stop and control valve with stems arranged at right angles to
each other are combined in a common body.
The IP turbine has four combined reheat stop and control valves. The
reheat stop valves are spring loaded single-seat valves. The control
valves operate in parallel and are fully open in the upper load range. In
the lower load range, they control the steam flow to the IP turbine and
ensure stable operation even when the turbo set is supplying only the
station load.
Turbine Governing System
The turbine has an electro-hydraulic governing system. An electric
system measures and controls speed and output, and operates the
control valves hydraulically in conjunction with an electro-hydraulic
converter. The electro-hydraulic governing system permits run-up control
of the turbine up to the rated speed and keeps speed swings following
sudden load shedding low. The linear-output characteristic can be very
closely set even during operation.

138
An Electro Hydraulic Governor

Barring Gear
The barring gear is mounted on the LP rear bearing cover to mesh with
spur gear on the LP rotor rear coupling. The primary function of the
barring gear is to rotate the turbo-generation rotors slowly and
continuously during start-up and shut down periods when changes in
rotor temperature occur.
When a turbine is shut down, cooling of its inner elements continues for
many hours. If the rotor is allowed to remain standstill during this cooling
period, distortion of rotor begins almost immediately. This distortion is
caused by flow of hot vapors to the upper part of the casings, resulting in
upper half of the turbine beings at a higher temperature, than lower half.
Hence to eliminate the possibility of distortion during shut-down, barring
gear is used to keep the rotor revolving until the temperature change has
stopped and casings have become cool.

139
The same phenomenon is also observed during starting of the turbine,
when steam is supplied to the sealing to create the vacuum. If the rotor
is stationary, there would be non- uniform heating of the rotor which will
result in distortion of rotors. The barring gear during starting of turbine,
would slowly rotate the turbine-generator rotor, and thereby resulting in
the uniform heating of rotor. Thus any distortion on the rotor would be
avoided. During starting, period operation of the barring gear eliminates
the necessity of ‘breaking away’ the turbine generator rotors from stand-
still and thereby provides for a more uniform, smooth and controlled
starting.
Turbine Oil system
Functions:
1. For lubricating and cooling the bearings.
2. Driving the hydraulic turning gear during interruptions to operation,
on start up and shutdown.
3. Jacking up the shaft at low speeds (turning gear operation, start-up
and shut-down)
Oil System
When the machine is running, the main oil pump situated in the bearing
pedestal draws oil from the main oil tank by injectors and conveys it to
the pressure system for lubrication. The return oil is drained into the
tank. During ‘the start up and shut down condition’, one of the two full
load auxiliary oil pumps circulates the oil.
When the main and full load auxiliary oil pumps fail, the lubrication oil is
maintained by a DC- driven emergency oil pump.
The jacking oil required for supporting the shaft system is supplied by
one of the two jacking oil pumps, which takes its suction from the main
oil tank. Two oil vapor extractors are mounted on the MOT to produce

140
slight vacuum in the main oil tank and the bearing pedestals to draw off
any oil vapors. There are 2x100% oil coolers and a duplex filter on the
oil line to thrust bearings. Main oil tank is provided with a basket filter.

Oil specification
 Name of Oil Servo Prime 46
 Specific Gravity at 500C 0.852
 Kinematic viscosity at 500C 28 centistokes
 Flash point 2010C (min.)
 Pour point -6.60C (max.)
 Ash percentage by weight 0.01%
 Mechanical impurities Nil

Main Oil Tank


The main oil tank not only serves as a storage tank but also for
detrainment the oil.
The capacity of the tank is such that the full quantity of oil is circulated
not more than 8 times per hour. This results in a retention time of
approx. 7 to 8 minutes from entry into the tank to suction by the pump.
This time allows sedimentation and detrainment of the oil.
Oil returning to the tank from the oil supply system first flows through a
submerged inlet into the riser section of the tank where the first stage
deaeration takes place as the oil rises to the top of the tank. Oil flows
from the riser section through the oil strainer into the adjacent section of
the tank where it is then drawn off on the opposite side by the suction
pipe of the oil pumps.

141
Main Oil Pump
The main oil pump is situated in the front bearing pedestal and supplies
the entire turbine with oil that is used for bearing lubrication, cooling the
shaft journals and as primary and test oil. It is coupled with turbine rotor
through a gear coupling. The main oil pump is driven direct from the
turbine shaft via the coupling. These pumps also convey oil in the
suction branches of the main oil pump for oil injector, which maintains a
steady suction flow to main oil pump. It takes over when the turbine
speed is greater than 2800 rpm.
Auxiliary Oil Pump
The auxiliary oil pump is a vertical one stage rotary pump with a radial
impeller and spiral casing. It is fixed to the cover of the oil tank and
submerges into the oil with the pump body. It is driven by an electric
motor that is bolted to the cover plate of the main oil tank. The pump
shaft bearing in the pump casing and a grooved ball bearing in the
bearing yoke. The bearings are lubricated from the pressure chamber of
the pump; the sleeve bearing via a bore in the casing; the grooved ball
bearing via lube line. Generally, three in number, two AC motor driven
and one DC motor driven. Supplies oil during turbo-set starting and
stopping when the turbine is running at speed lower than 2800 rpm
supplies oil to governing system as well as to the lubrication system. It
also serves as standby to main centrifugal oil pump.
Emergency Oil pump
This is a centrifugal pump, driven by D.C. electric motor. It is vertical
type. This automatically cuts in whenever there is failure of A.C. supply
at power station and or the lub oil pressure falls below a certain value.
This pump can meet the lubrication system requirement under the
conditions mentioned above.

142
Shaft lift oil pump (Jacking Oil Pump)
The lift oil pump is a self-priming screw-spindle pump with three spindles
and internal bearings. It is a jack-screw immersion pimp situated on the
tank. The pump supplies high pressure (about 12 kgf/cm2) oil from the
main oil tank in order to lift the turbine rotor at low speeds, thus
preventing damage to the bearings when shaft speeds are too low for
hydrodynamic lubrication to take place. The pump is driven by a three
phase A.C. motor. The pressure oil piping of the lifting oil pump that is
not in operation is closed by the check valves. The pressure in the
system is kept constant by means of the pressure limiting valve. When
the turbine is started up or shut down, the hydraulic lifting device is used
to increase or maintain the oil film between the rotor and bearings. The
necessary torque from the hydraulic turning device or from the manual
turning device is reduced in this way. The bearings are relieved by high
pressure oil that is forced under the individual bearing pins, thus raising
the rotor. In order to avoid damage to the bearings, the lifting oil pump
must be switched on below a certain speed. The drain from the bearings
is connected back to the oil tank only.
Oil coolers
The oil of the lubrication and governing system is cooled in the oil
coolers. The cooling medium for these coolers is circulating water. It
Consists of tube nest, inner & outer shell & water boxes. The pressure of
the cooling water is kept lower than that of oil to avoid its mixing with oil
in the event of tube rupture.
Five oil coolers have been foreseen, out of which four are for continuous
operation and one remains as a standby, provided the cooling water
temperature is not more than 360C. The oil coolers are in parallel for
maintenance purposes, the oil and cooling water system to any one of
the oil coolers may be cut off. Oil temperature controller is employed for

143
maintaining the lub oil temp at rated value by controlling the flow through
the coolers.
Duplex oil filter
It is provided to filter the oil before supply. The duplex filter consists of
two filter bodies and is fitted with a changeover device which enables the
filters to be switched as desired.
Three-way control valve
It is electrically driven and has the function of regulating the lubricating
oil temperature. Possible oil flow paths for regulating the oil temperature
are:
1. All lubricating oil flows through the oil cooler.
2. Lubricating oil flows through oil cooler and by-pass piping
3. All lubricating oil flows through the by-pass piping.
Condensate system
Condensate: The steam after condensing in the condenser is known as
condensate, and is extracted out of the hot well by condensate
extraction pump and taken to the deaerator through drain cooler, gland
steam condenser and series of LP heaters.
This contains the following:
Low Pressure heaters
Turbine is provided with non-controlled extractions which a r e
utilized for heating the condensate from turbine
b l e e d i n g s y s t e m . There are four 10W pressure LP heaters in
which the last four extractions are used. LP Heater-1 has two parts LPH-
1A a n d L P H - 1 B l o c a t e d i n t h e u p p e r p a r t s o f
c o n d e n s e r A a n d condenser B respectively. These are of
horizontal type with shell and tube construction. LP heaters 2, 3 and
4 are of similar construction a n d t h e y a r e mo u n t e d i n a r o w a t

144
4 m l e ve l . Th e y a r e o f ve r t i c a l construction with brass tubes the
ends of which are expanded into tube plate. The condensate flows
in the "U" tubes in four passes and extraction steam washes the
outside of the tubes. Condensate passes through these four L.P.
heaters in succession. These heaters are equipped with necessary
safety valves in the steam space level indicator for visual level
indication of heating steam. Condensate pressure vacuum gauges
are employed for measurement of steam pressure etc.

LPT

1ST STAGE

Stages of LP heating

An LP heater
145
Condensate Extraction Pumps

The function of these pumps is to pumps out the condensate to the


desecrator through ejectors, gland steam cooler, a n d L P h e a t e r s .
These pumps are of vertical barrel or canister,
double suction, multi stage, diffuser type. The
suction barrel is installed on the pump floor. Internal
bearings (Leaded bronze bearings) installed in a
column pipe and the top casing is provided for
supporting the pump shaft against the radial load.
Upper and lower bearings (leaded bronze) are
installed in the stuffing box and suction bell. The
weight of the pump rotor and the hydraulic thrust
acting on the rotor in the axial directions are
supported by the thrust bearings in the motor. These
pumps are driven by 1120 KW induction motor,
delivering 810000 kg/hr of condensate water against
307m of total dynamic head at the rated condition.
T h e s e p u m p s h a v e f o u r s t a g e s a n d s i n c e t h e suction is

146
at a negative pressure, special arrangements have been m a d e
for providing sealing. This pump is rated generally
f o r 160m3/ hr. at a pressure 13.2 Kg/cm2. They are 3 per unit of 50%
capacity each located near the condenser hot well. Here the suction is
under vacuum.

Condenser Extraction pumps

Hot well 147


Specifications of CEP

A Condenser Extraction Pump


148
Deaerator

One per unit located around 18m level in CD bay. The presence of
certain gases, principally oxygen, carbon dioxide and ammonia
dissolved in water is generally considered harmful because of their
corrosive attack on metals, particularly at elevated temperatures. One of
the most important factors in the prevention of internal corrosion in
modern boilers and associated plant therefore, is that the boiler feed
water should be free as far as possible from all dissolved gases
especially oxygen. This is achieved by embodying into the boiler feed
system a deaerating unit, whose function is to remove dissolved gases
from the feed water by mechanical means. Particularly the unit must
reduce the oxygen content of the feed water to as low as possible or
desired, depending upon the individual circumstances, residual oxygen
content in condensate at the outlet of deaerating plant usually specified
0.005/liter or less. Water is sprayed in atmosphere of steam. Oxygen
and free CO2 removed. This preheated water having minute traces of
dissolved gases flows into second stage where water is in contact with
fresh steam. The steam then rises to first stage and carries residual
gases. Water is stored in storage tank for further use. The main sources
of this steam are Extraction steam, CRH (cold reheat steam), auxiliary
steam.

Parts of a deaerator are

• Tubular type gauge glass.

• High level alarm switch.

• Low level alarm switch.

• Pressure gauge.
Deaerator level controller
149
• Safety valves

• Isolating valves for steam pipes.

Specifications of a deaerator

• Design pressure - 9.0 kg/cm2

• Operating pressure - 6.8 kg/cm2

• Capacity - 170 m3

• No. of trays - 576

• No. of spray valves - 108

• No. of safety valves - 6

An Overview of deaerator and hot well

150
A Deaerator

151
Feed water system

The main equipments coming under this system are:

Booster Pump
Each boiler feed pump is provided with a booster pump in its suction line
which is driven by the main motor of the boiler feed pump. By the use of
a booster pump in the main pump suction line, always there will be
positive suction pressure which will remove the possibility of Cavitation.
Each pump set consists of a Weir type FAIE 64 booster stage pump and
a Weir type FK4E36 pressure stage pump.
The Weir type FAIE 64 booster stage pump is a single stage, horizontal,
axial split casing type, having the suction and discharge branches
integrally cast in the casing lower half, thus allowing the pump internals
to be removed without disturbing the suction and discharge pipe work or
the alignment between the pump and discharge.
The pump shaft is sealed at the drive end and non-drive end by Crane
mechanical seals. The rotating assembly is supported by plain white
metal lined journal bearings and axially located by Glacier double tilting
pad thrust bearing.

152
Specifications
 Single stage, horizontal, axial split casing
 Aim: to obtain positive suction pressure in order to avoid cavitation
 suction temp : 164 0c
 suction pressure : 9.06 bar
 discharge pressure : 20.3 bar
 speed : 1494 rpm
 power consumption : 608 kW

Boiler Feed Pumps


They are three per unit of 50% capacity each located in the 0m level in
the TG bay. The pump is Weir type FK4E36 pressure stage pump. It is a
multi- stage pump. This pump is horizontal at zero level and of barrel
design driven by an Electric motor through a hydraulic coupling. All the
bearings of pump and motor are forced lubricated by a suitable oil
lubricating system with adequate protection to trip the pump if the
lubrication oil pressure falls below a preset value. The pump internals
are designed as a cartridge which can be easily removed for
maintenance without disturbing the suction and discharge pipe work, or
the alignment of the pump and the turbo coupling. The pump is sealed
at the drive end and non-drive end by labyrinth glands.
The pump casing consists of a forged steel barrel with welded suction,
discharge branches; inter stage tapping and mounting feet.
The high-pressure boiler feed pump is very expensive m a c h i n e
which calls for a very careful operation and skilled
m a i n t e n a n c e . Th e s a f e t y i n o p e r a t i o n a n d e f f i c i e n c y o f t h e
f e e d pump depends largely on the reliable operation and
maintenance. Operating staff must be able to find out the causes of

153
defect at the very beginning which can be easily removed without
endangering t h e o p e r a t o r o f t h e p o we r p l a n t a n d a l s o wi t h o u t
t h e e xp e n s i ve dismantling of the high pressure feed pump.
The feed pump consists of pump barrel, into which is mounted the inside
stator together with rotor. The hydraulic part is e n c l o s e d b y t h e
h i g h p r e s s u r e c o v e r a l o n g w i t h t h e b a l a n c i n g d e vi c e .
The suction side of the barrel and the space in the
h i g h pressure cover behind the balancing device are enclosed by the
low pressure covers along with the stuffing box casings. The
brackets o f t h e r a d i a l b e a r i n g o f t h e s u c t i o n s i d e a n d
r a d i a l a n d t h r u s t bearing of the discharge side are fixed to
the low pressure covers. T h e e n t i r e p u m p s a r e
m o u n t e d o n a f o u n d a t i o n f r a m e . T h e hydraulic
coupling and two claws coupling with coupling guards a r e a l s o
d e l i ve r e d a l o n g wi t h t h e p u m p . W a t e r c o o l i n g a n d o i l
lubricating are provided with their accessories. The use of Mechanical
seal reduces the losses of feed water in the stuffing box to maintain and
working ability of the feed pump increases. Cooling is carried out by the
circulation of water between the stuffing box space and the cooler. Even
after stopping the pump stuffing box cooling should be continued as its
cooling circuit is different from the seal coolers. Coolers are designed to
keep the stuffing box space temperature below 800C. The rotating
assembly is supported by plain white metal lined journal bearings and
axially located by Glacier double tilting pad thrust bearing. BFP have two
main uses namely, to give the required pressure to the feed water before
entering into boiler and to supply water for de superheating in the boiler.

154
Sectional view of a Boiler Feed pump
Specifications

 single cylinder turbine


 axial flow type
 No of stages  14
 Normal speed  5275 rpm
 Steam pr.  6.33 kg/cm2
 Output  5732 kW
 Steam cons.  36 tons/hr

Turbine Driven Boiler Feed Pump

The single cylinder turbine is of the axial flow type. The live steam
flows through the emergency stop valve and then through the main
Control Valves 5 nos. (Nozzle governing). These valves regulate the
steam supply through the turbine in accordance with load

155
requirements. The control valves are actuated by a lift b a r
which is raised or lowered via a lever system by the
r e l a y cylinder mounted on the turbine casing.
The journal bearings supporting the turbine shaft are arranged in the
two bearing blocks. The front end -bearing block also houses the
thrust bearing, which locates the turbine shaft and takes up "the
axial forces”. There are 14 stages of reaction balding. The
balancing piston is provided at the. Steam admission side to
compensate the axial thrust to the maximum extent. Since the
axial thrust varies with the load, the residual thrust is taken up
by the thrust bearing. T h e l e a k o f f f r o m t h e b a l a n c i n g p i s t o n
i s c o n n e c t e d b a c k t o t h e turbine after 9th stage. The turbine is
provided with hydraulic and electro-hydraulic governing system. A
primary oil pump is used as a speed sensor for hydraulic governing and
shall Probes are used as a speed sensor for electro hydraulic governing.
Whenever steam is drawn from the cold reheat line or a u xi l i a r y
s u p p l y, s t e a m f l o w i s c o n t r o l l e d b y a u xi l i a r y c o n t r o l va l ve .
D u r i n g t h i s p e r i o d t h e ma i n c o n t r o l va l ve s ( 4 n o s . ) wi l l
r e m a i n f u l l y o p e n e d a n d t h e b yp a s s va l ve a c r o s s i t wi l l
r e m a i n c l o s e d . ( B yp a s s r e m a i n s c l o s e d f o r a s h o r t p e r i o d
wh e n c h a n g e , over from IP steam to CRH takes place).The steam
exhaust for the BFP- Turbine is connected to the main condenser and
the turbine glands are sealed by gland steam.

The turbine is provided with a hand barring facility. The turbine rotor is
connected to the pressure pump through detachable coupling and to the
booster pump through a set of reduction gears. A plate type filter is
provided and either one can be isolated during the running of the
turbine. The control oil pressure is around 5 to 8 ata and the lubricating

156
oil pressure is 0.8 to 1.7 atm. The oil temperature after the coolers is to
be maintained at 450C to 480C.

Turbine driven Boiler Feed Pump

157
High Pressure Heaters

They are three in number and are situated in the TG bay. These are
regenerative feed water heaters operating at h i g h p r e s s u r e a n d
l o c a t e d b y t h e s i d e o f t u r b i n e . T h e s e a r e generally
vertical type and turbine bleed steam pipes are connected to them. HP
heaters are connected in series on feed waterside and by such
arrangement, the feed water, after feed pump enters t h e HP
heaters. The steam is supplied to these heaters form
t h e bleed point of the turbine through motor operated valves.
These heaters have a group bypass protection on the feed waterside.
In the event f tube rupture in any of the HPH and the level of the
condensate rising to dangerous level, the group protection
device d i v e r t s a u t o m a t i c a l l y t h e f e e d w a t e r
d i r e c t l y t o b o i l e r , t h u s bypassing all the three HP heaters.

Following fittings are generally provided on the HP heaters


 Gauge glass for indicating the drain level.
 Pressure gauge with three way cock.
 Air Vent cock.
 Safety valve shell side.
 Seal pot.
 Isolating valves.
 High level alarm switch.

An HP heater 158
An HP heater

159
OFFSITE MAINTAINANCE

160
DM water treatment plant
As the types of boiler are not alike their working pressure and operating
conditions vary and so do the types and methods of water
treatment. Water treatment plants used in t h e r m a l p o w e r
plants are designed to process the raw water to
water low in dissolved solids known as "dematerialized w a t e r " . N o
doubt, this plant has to be engineered very
carefully keeping in view the type of raw water to
t h e t h e r m a l p l a n t , i t s treatment costs and overall economics.
T h e t y p e o f d e m i n e r a l i z a t i o n p r o c e s s chosen for a
power station depends on three main factors:
 The quality of the raw water.
 The degree of de-ionization i.e. treated water quality
 Selectivity of resins.
Water treatment process which is generally made up
o f t w o sections:
 Pretreatment section
 Demineralization section
Pretreatment section
Pretreatment plant removes the suspended solids such as clay, silt,
organic and inorganic matter, plants and other microscopic
organism. The turbidity may be taken as of two types of suspended
solids in water. Firstly, the separable solids and s e c o n d l y t h e
non separable solids (colloids). The
c o a r s e components, such as sand, silt etc, can be removed from the
water by simple sedimentation. Finer particles however, will not settle in
any reasonable time and must be flocculated to produce the
large p a r t i c l e s w h i c h a r e a b l e t o s e t t l e . L o n g t e r m

161
a b i l i t y t o r e m a i n suspended in water is basically a function of
both size and specific g r a v i t y . T h e s e t t l i n g r a t e o f t h e
c o l l o i d a l a n d f i n e l y d i v i d e d (approximately 0.01 to 1
micron) suspended matter is so slow that removing them from
water by plain sedimentation is tank shaving o r d i n a r y d i m e n s i o n s i s
i m p o s s i b l e . S e t t l i n g ve l o c i t y o f f i n e l y divided and collide
particles under gravity also are so small that ordinary
sedimentation is not possible. It is necessary, therefore, to use
procedures which agglomerate the small particles into
larger a g g r e g a t e s , wh i c h h a ve p r a c t i c a l s e t t l i n g ve l o c i t i e s .
T h e t e r m "Coagulation" and "flocculation" have been used
indiscriminately to describe process of turbidity removal.
"Coagulation" means to bring together the suspended particles.
The process describes the e f f e c t p r o d u c e d b y t h e a d d i t i o n
of a chemical Al (SP) g to a colloidal dispersion
r e s u l t i n g i n p a r t i c l e d e s t a b i l i z a t i o n b y a reduction of force
tending to keep particles apart. Rapid mixing is i m p o r t a n t a t t h i s
stage to obtain. Uniform dispersion of the
chemical and to increase opportunity for particles to
particle c o n t a c t . T h i s o p e r a t i o n i s d o n e
b y f l a s h m i x e r i n t h e clarifier. Second stage of
formation of settle able particles f r o m destabilized
colloidal sized particles is termed a
"flocculation". Here coagulated particles grow in size by attaching to
each other. In contrast to coagulation where the primary force is
electro static or intrinsic, "flocculation" occurs
b y c h e m i c a l bridging. Flocculation is obtained by gentle and
prolonged mixing w h i c h c o n v e r t s t h e s u b m i c r o s c o p i c
c o a g u l a t e d p a r t i c l e i n t o discrete, visible & suspended

162
particles. At this stage particles are l a r g e e n o u g h t o s e t t l e
r a p i d l y u n d e r t h e i n f l u e n c e o f g r a v i t y anomaly be removed.
This is best at pH ~6.5 - 7.0 & higher retention time.

For removing the organic matter chlorine as a biocide is dosed in


clarifier. It is essential to remove organic matter because it may lead to
fouling of ion exchange resin in DM Plant. Also the organic matter at
high temperature may get converted to CO2 & cause metal corrosion in
boiler system. To completely eliminate the organic matter a slight excess
of chlorine is dosed (~ 0.5ppm at Clarifier O/l).The clarified water so
produced is passed through filter beds (Graded Sand / Anthracite can be
used) to remove any floating turbid matter. This is called filtered water.
This water is being used for drinking purpose & for demineralization.

Raw water being pre treated

If pretreatment of the water is not done


e f f i c i e n t l y t h e n t h e consequences are as follows:

 S i 0 2 m a y e s c a p e wi t h wa t e r wh i c h wi l l i n c r e a s e t h e
a n i o n loading.
 Organic matter may escape which may cause organic fouling i n
the anion exchanger beds. In the 'pre-treatment
163
plant chlorine addition provision is normally
m a d e t o c o m b a t organic contamination.
 Cation loading may unnecessary increase due to addition
of Ca (OH)2 in excess of calculated amount for raising the pH
of t h e wa t e r f o r m a xi mu m f l o e f o r m a t i o n a n d a l s o
A K O r Dg m a y p r e c i p i t a t e o u t . I f l e s s t h a n
calculated amount of Ca (OH)2 is added,
p r o p e r p H f l o c c u l a t i o n w i l l n o t b e obtained and
silica escape to demineralization section will occur, thereby
increasing load on anion bed.
Demineralization section
This filter water is now used for d e mi n e r a l i z i n g p u r p o s e a n d
i s f e d t o c a t i o n e xc h a n g e r b e d , b u t enroute being first de
chlorinated, which is either done by passing through activated
carbon filter or injecting along the flow of water, a n e q u i va l e n t
a mo u n t o f s o d i u m s u l p h i t e t h r o u g h s o m e s t r o k e pumps.
Excess chlorine is removed in ACF.At ACF O/l Turbidity <0.1 NTU &
Free Cl2 <0.1ppm. The absorbed chlorine is released by backwash
whenever Free Cl2 >0.1ppm or the end of rated cycle whichever is
earlier. The residual chlorine which is- maintained in clarification plant to
remove organic matter from raw water is now detrimental to action resin
and must be eliminated before its entry to this bed. Normally, the
typical scheme of demineralization up to the .mark against average
surface water is three bed systems with a provision of removing
gaseous carbon dioxide from water before feeding to Anion
Exchanger.

Resins, which are built on synthetic matrix of a styrene divinely benzene


copolymer, are manufactured in such a way that these have the ability

164
to, exchange one ion for another, hold it temporarily in chemical
combination and give it to a strong electrolytic solution. Suitable
treatment is also given to them in such a way that a particular resin
absorbs only a particular group of i o n s . Re s i n s , wh e n a b s o r b i n g
and releasing cationic portion of d i s s o l v e d s a l t s , i s
c a l l e d c a t i o n , e x c h a n g e r r e s i n a n d w h e n removing
anionic portion is called anion exchanger resin. Preset trend is of
employing 'strongly acidic cation exchanger resin and s t r o n g l y
b a s i c a n i o n e xc h a n g e r r e s i n i n a D M P l a n t o f m o d e r n
t h e r ma l p o w e r s t a t i o n . W e ma y s e e t h a t t h e c h e m i c a l l y
a c t i ve group in a cationic resin is SO x -H (normally represented
by RH) and in an anionic resin the active group is either tertiary
amine or quaternary ammonium group (normally the resin is
represented by R O H ) . Th e r e a c t i o n o f e xc h a n g e m a y b e
f u r t h e r r e p r e s e n t e d a s below

Cation Resin
R-H + Na  R-Na + H2SO4
K K HCl
Mg Mg
Ca Ca HNO3
In the form of Resins in Removed in
Salts H2CO3 degasser tower

Anion Resin
R-OH + H2SO4  R-SO4 + H2O
HCl
HNO3
Mineral acid obtained Resins in
from cation exhausted form

165
The water from the ex-cation contains carbonic acid also sufficiently,
which is very weak acid difficult to be removed by strongly basic anion
resin and causing hindrance to remove silicate ions from the bed. It is
therefore a usual practice to remove carbonic acid before it is led to
anion exchanger bed; this is done in a degasser.

DM plant storage tanks and degasser towers

In the degasser, the ex-cation water is trickled in fine streams


from top of a tall tower packed with, rasching rings, and compressed
air is passed from the b o t t o m. Ca r b o n i c a c i d b r e a k s i n t o C0 2
a n d wa t e r me c h a n i c a l l y ( H e n r y ' s L a w ) w i t h t h e
c a r b o n d i o x i d e e s c a p i n g i n t o t h e atmosphere.
T h e wa t e r i s a c c u mu l a t e d i n s u i t a b l e s t o r a g e ta n k below the
tower, called degassed water dump from where the same is led to anion
exchanger bed, using acid resistant pump.
H2CO3  H2O + CO2
The ex-anion water is fed to the mixed bed exchanger (regenerative
type ion exchanger resin beds both strong and weak) containing
both cationic resin and anionic resin. This bed not only takes
care of sodium slip from cation but also silica slip from anion
exchanger very effectively. The final output from t h e m i x e d
bed is Exira-ordinarily pure water having less
t h a n 0.2/mho conductivity 7.0 and silica content less than 0.02 pm. Any

166
deviation from the above quality means that the resins in
mixed b e d a r e e x h a u s t e d a n d n e e d r e g e n e r a t i o n ,
r e g e n e r a t i o n o f t h e mixed bed first calls for suitable, back
washing and settling, so that the two types of resins are separated from
each other. Lighter anion r e s i n r i s e s t o t h e t o p a n d th e h e a vi e r
c a t i o n r e s i n s e t t l e s t o t h e bottom. Both the resins are then
regenerated separately with alkali and acid, rinsed to the desired value
and air mixed, to mix the resin a g a i n t h o r o u g h l y . I t i s t h e n p u t
t o f i n a l r i n s i n g t i l l t h e d e s i r e d quality is obtained. It may be
mentioned here that there are two types of s t r o n g l y b a s i c a n i o n
e xc h a n g e r . T yp e I I r e s i n s a r e s l i g h t l y l e s s basic than type I,
but have higher regeneration efficiency than type I. Again as type II
resins are unable to remove silica effectively, t yp e I r e s i n s a l s o
h a ve t o b e u s e d f o r t h e p u r p o s e . A s s u c h , t h e general
condition so far prevailing in India, is to employ type II resin in
anion exchangers bed and type I resin in mixed bed (for the
anionic portion). It is also a general convention to regenerate the above
two resins under through fare system i.e. the caustic soda
entering into mixed bed for regeneration, of type I anion resin, is
u t i l i z e d t o r e g e n e r a t e t yp e I I r e s i n i n a n i o n e xc h a n g e r b e d .
T h e c o n t e n t o f u t i l i z i n g t h e a b o ve r e s i n a n d m o d e o f
r e g e n e r a t i o n i s now days being switched over from the
economy to a higher cost s o a s t o h a v e m o r e s t r i n g e n t
q u a l i t y c o n t r o l o f t h e f i n a l D M water.

R-OH + HCl  RCl + H20

2 R-OH + H2SO4  R2SO4 +2H20

167
At anion O/l, pH 8-9, Conductivity < 20 umhos/cm , Silica< 200 ppb will
be achieved.

Cation and anion exchange


resin unit in a DM plant

Internal Treatment

This final D.M. effluent is then either led to hot well of the condenser
directly as make up to boilers, or being stored in D.M. Water
storage tanks first and then pumped for makeup purpose to boiler feed.
As the D.M. Water has a good affinity to absorb carbon dioxide and
oxygen, and both are extremely harmful to metal surfaces for their
destruction like corrosion, these have to b e r e m o v e d b e f o r e i t
i s f e d t o b o i l e r . T h i s i s b e i n g d o n e i n desecrator.
S t i l l t h e r e s i d u a l o xyg e n wh i c h i s r e ma i n i n g i n t h e water is
neutralized by a suitable doze of hydrazine, at the point a f t e r
d e s e c r a t o r . To h a ve f u r t h e r m i n i mu m c o r r o s i o n , t h e p H
o f f e e d wa t e r i s t o b e ma i n t a i n e d a t a r o u n d 9 .0 f o r wh i c h
p u r p o s e ammonia in suitable doze is added to this make up water at a
point along with hydrazine as stated above.

168
Cooling towers
Necessity
Cooling water system plays a vital role in dissipation of waste heat in
power station. More than 60 % of total heat input to the plant is finally
dissipated as waste heat. The waste heat from the power plant is carried
away by circulating water and ultimately gets dissipated in cooling tower.

Where water supply is not consistent, closed loop cooling system with cooling tower
is used.

Types
 Natural draught cooling tower (NDCT): These are structures
supported on RCC columns, Most of the structure is empty shell
but the lower portion contains a cooling stack over which hot water
is distributed by RCC channel or pipe system. The lower portion of
the shell is open to allow the air to go to the cooling stack
supported on the RCC columns, which are designed for horizontal
load due to wind. A pond is constructed below the toer to catch the
cooled water and make-up water for circulation. As the warm water
falls in the stack, it gives its heat to the air there, which becomes

169
lighter than the ambient air and a draft is created due to chimney
action. In this case, cooling is dependent on dry bulb temperature
i.e. better in humid conditions. Natural draft cooling towers are
normally adopted near coastal areas where humidity is generally
very high. But the capital cost of NDCT is about 60% than that of
IDCT and FDCT put together.
 Induced draught cooling tower (IDCT): In this system the fan is
located at the top and air enters from the openings located at the
ground level. Air, mixed with vapors, is discharged through a fan
stack located at the top of the tower. In this case, moist air is
discharged higher in the atmosphere thereby dispersing to a
greater distance from the tower. There is a cylindrical RCC
structure supported on RCC columns. Hot water is taken to the top
of the tower by steel pipes and discharged on the packing with
distribution system of precast RCC trough and tubes. Eliminators
of asbestos are provided at the top to arrest the droplets. The fan
is located at the top to draw air from the cylinder for dispersion.
Hot water is cooled by the induced air travelling up. Cold water is
collected in the pond located below the cooling tower where make
– up water is also discharged.
 Forced draught cooling tower (FDCT): Here, motor driven fans
located at the base, i.e. ground level, below air into the tower from
the sides. The top of the tower is open to the air vapor discharge.
The main draw back in this type of tower is that exit velocity is low
and this results in recirculation of hot air into the fan intake. Thus,
the efficiency of the tower is reduced. The other disadvantages of
FDCTs are: High velocity from the fan located at the base makes it
difficult to distribute air evenly over the whole of packing. Low
height, low velocity of air and low wind velocity generally results in
170
recirculation of hot air. This results in rise in cold water
temperature and reduction in efficiency. Frequent clogging due to
organic matter and thus reduction in efficiency.
At NTPC Simhadri, each unit has one Natural Draft Cooling Tower.
Principle:

Natural Draft CT depends on the airflow caused by natural driving


pressure due to the density difference between the cool outside air and
hot humid air inside. The driving pressure “P” is given by

P = (density (o) – density (i) fill exit)* H

Normally the density difference is low. Hence “H” has to be more in order
to achieve “P”. The Hyperbolic profile of NDCT offers great resistance to
outside wing loading and superior strength when compared to other
forms. It has little to do with inside air flow.

DETAILS OF NDCTs OF STAGE-I (2X500 MW)

• No. of NDCTs: 2

• Height of NDCT: 165 m

• Bottom diameter: 100 m

• Top diameter: 70 m

• Total no of Racker columns: 88 per NDCT

• Shell thickness: 300-350 mm


A Natural Draught Cooling Tower

171
An Induced Draft Cooling Towers A Forced Draft Cooling Towers

Types of Cooling Towers

172
Inner view of an NDCT

Drift Eliminators

173
Circulating water system
Modern high capacity thermal power stations require enormous quantity
of water for steam production. This steam has to be recycled again to
generate power. For recycling steam, it has to be condensed into water.
Circulating water is a system that is used for condensing the steam.

Circulating Water System at NTPC


Simhadri
USES OF CIRCULATING WATER
 Condensing of steam
 Cooling of dm cooling water
 Ash evacuation
 Bottom de ashing
 Fly ash removal

174
Theory of circulation
Water must flow through the heat absorption surface of the boiler in
order that it is evaporated into steam. In d r u m t yp e u n i t s
( n a t u r a l a n d c o n t r o l l e d c i r c u l a t i o n ) t h e wa t e r i s circulated
from the drum through the generating circuits and then back to
the drum where the steam is separated and directed to the super
heater. The water leaves the drum through the down comers a t a
t e mp e r a t u r e s l i g h t l y b e l o w t h e s a t u r a t i o n t e m p e r a t u r e . Th e
f l o w t h r o u g h t h e f u r n a c e wa l l i s a t s a t u r a t i o n t e mp e r a t u r e .
H e a t a b s o r b e d i n wa t e r wa l l i s l a t e n t h e a t o f va p o r i z a t i o n
c r e a t i n g a mixture of steam and water. The ratio of the weight of the
water to the weight of the steam in the mixture leaving the heat
absorption surface is called Circulation ratio.

Water circulation system in a Thermal


Power Plant

175
The types of boiler circulating system are:
 Natural circulation system
 Controlled circulation system
 Combines circulation system
Natural circulation system
Water delivered to steam generator from f e e d h e a t e r i s a t a
t e mp e r a t u r e we l l b e l o w t h e s a t u r a t i o n va l u e corresponding
to that pressure. Entering first the economizer it is h e a t e d t o
about 30-40˚C below saturation temperature. From
economizer the water enters the drum and thus joins the circulation
system. Water entering the drum flows through the down
comer and enters ring heater at the bottom. In the water walls a part of
the w a t e r i s c o n v e r t e d t o s t e a m a n d t h e m i x t u r e f l o w s
b a c k t o t h e drum. In the drum, the steam is separated, and sent to
super heater f o r s u p e r h e a t i n g a n d t h e n s e n t t o t h e
high pressure turbine. Remaining wat er mi xes
w i t h t h e i n c o m i n g w a t e r f r o m t h e economizer and
the cycle is repeated. The circulation in this case takes place on the
thermo-siphon principle. The down comers contain relatively cold water
whereas the riser tubes contain a steam water mixture. Circulation
takes place at such a rate that the driving force and the frictional
resistance in water walls are balanced.
As the pressure increases, the difference in density between water and
steam reduces. Thus the hydrostatic head available will not be able to
overcome the frictional resistance for a flow corresponding t o t h e
minimum requirement of cooling of water wall tubes.
T h e r e f o r e n a t u r a l c i r c u l a t i o n i s l i mi t e d t o t h e b o i l e r wi t h
d r u m operating pressure around 175 kg/cm².

176
Natural circulating system

Controlled circulation system


Beyond 80 kg/cm² of pressure, circulation is to be assisted with
mechanical pumps to overcome the frictional losses. To regulate the
flow through various tubes, orifice plates are used. This system is
applicable in the high sub-critical regions (200 kg/cm²).

Combined circulation system


Beyond the critical pressure, phase t r a n s f o r m a t i o n i s a b s e n t ,
a n d h e n c e o n c e t h r o u g h s y s t e m i s adopted.
H o we ve r , i t h a s b e e n f o u n d t h a t e ve n a t s u p e r
c r i t i c a l p r e s s u r e , i t i s a d va n t a g e o u s t o r e c i r c u l a t e t h e
wa t e r t h r o u g h t h e f u r n a c e t u b e s a n d s i m p l i f i e s t h e
s t a r t u p p r o c e d u r e . A t y p i c a l operating pressure for such a
system is 260 kg/cm².

177
Principal Components of CWS
Condenser
There are two condensers entered to the two exhausters of the LP
turbine. These are surface type condensers with two pass arrangement.
Cooling water pumped into each condenser by a vertical CW pump
through the inlet pipe. Water enters the inlet chamber of the front water
box, passes horizontally through the brass tubes to the water box at the
other end, takes a turn, passes through the upper cluster of tubes and
reaches the outlet chamber in the front water box. From there, cooling
water leaves the condenser through the outlet pipe and discharged into
the discharge duct.
Steam exhausted from the LP turbine washing the outside of the
condenser tubes losses its latent heat to the cooling water in the steam
side of the condenser. This condensate collects in the hot well, welded
to the bottom of the condensers.

Sectional view of a condenser


178
Ejectors
There are two 100% capacity ejectors of the steam eject type. The
purpose of the ejector is to evacuate air and other non-condensing
gases from the condensers and thus maintain the vacuum in the
condensers.
A 3 stage ejector using steam from the deaerator with 11 ata header as
the working medium is employed. In addition to the main ejectors there
is a single starting ejector which is used for initial pulling of vacuum up to
500mm of Hg. It consists of nozzle through which the working steam
expands; the throat of the nozzle is connected to the air pipe from the
condenser.
C.W. pumps
The pumps which supply the cooling water to the condensers are called
circulating water pumps. There are two such pumps for each unit with
requisite capacity.
These pumps are normally vertical, wet pit, mixed flow type, designed for
continuous heavy duty; suitable for water drawn through an open gravity
intake channel terminating in twin-closed ducts running parallel to the
main building.
The fluid through the suction bow/eye provided with stream lined guide
vanes, whose function is to prevent pre-whirl and impart hydraulically
correct flow to the liquid. The propeller, in turn, imparts motion to the
fluid. The purpose of the discharge bowl provided with streamlined
diffuser vanes, is to direct the flow of water into the discharge column.
Bulk requirement of water is used in thermal plants for the purpose of
cooling the steam in condensers. The requirement of water for this
purpose is of the order of 1.5-to2.0 cusecs/MW of installation where
sufficient water is available once through system is used.

179
Specifications
 Discharge : 31000m3/hr
 Head:28m
 rpm:330rpm
 2 pumps per unit (60%)

A CW pump

A Plate Heat Exchanger for


cooling auxiliary cooling
water

An Overview CW system

An Overview of CW system
180
Auxiliary cooling water system
Usually a part of the water to condenser is tapped off and supplied for
the following sub-systems:
Turbine lub oil and gas cooler directly from CW pump discharge
Bearing cooling system
DM plant
General services and miscellaneous cooling.

181
ASH HANDLING PLANT

182
Ash Handling System
The ash produced in the boiler is transported to ash dump area by
means of sluicing type hydraulic ash handling system, which consists
of Bottom ash system, Ash water system and Ash slurry system.
Bottom ash system
In the bottom ash system the ash d i s c h a r g e d f r o m t h e
f u r n a c e b o t t o m i s c o l l e c t e d i n t w o w a t e r compounded
scraper through installed below bottom ash hoppers. The ash is
continuously transported by means of the scraper chain c o n ve yo r
o n t o t h e r e s p e c t i ve c l i n k e r g r i n d e r s wh i c h r e d u c e t h e l u m p
sizes to the required fineness. The crushed ash from
t h e bottom ash hopper from where the ash slurry is further transported
to operation, the bottom ash can is discharged directly
i n t o t h e sluice channel through the bifurcating chute bypass the
grinder. The position of the flap gate in the bifurcating chute
bypasses the grinder. The position of the flap gate in the bifurcating
chute is to be manually changed. The main types of hoppers used in
power stations are:
1. Water Filter Hoppers: This consists of a tank made of steel plate.
The bottom ash from the boiler falls into water filled tank and is
immediately quenched large pieces of ash break up due to
thermal shock, thus the ash collected will be fairly small size and
during the disposal not much difficulty in terms of crushing aspects
will be encountered. These hoppers may or may not be lined with
refractory which goes off too frequently due to temperature
variations. The unlined hoppers have problems on corrosion for
which special coating are recommended.

183
2. Quencher cooled Ash hopper: This uses a series of quenchers
located near the top of the hoppers which provide fine spray of
water. This ensures that the ash is cooled sufficiently to prevent
after combustion and simitering within the hopper. The spray water
also keeps the refractory lining of the hopper cool. The quencher
type hoppers are not very effective as far as the breaking up of ash
due to thermal shocks is concerned. If there is a tendency of slag
accumulation of large pieces clinker grinders are normally used.

Bottom ash handling system

Fly ash system


The flushing apparatus are provided under E . P . h o p p e r s ( 4 0
n o s . ) , e c o n o m i z e r h o p p e r s ( 4 n o s . ) , a i r p r e heaters (2
n o s . ) , a n d s t a c k h o p p e r s ( 4 n o s . ) . Th e f l y a s h g e t s mixed
with flushing water and the resulting slurry drops into the a s h
s l u i c e c h a n n e l . L o w p r e s s u r e wa t e r i s a p p l i e d t h r o u g h t h e
nozzle directing tangentially to the section of pipe to
create t u r b u l e n c e a n d p r o p e r m i x i n g o f a s h
w i t h w a t e r . F o r t h e maintenance of flushing apparatus
plate valve is provided between apparatus and connecting tube.

184
Fly ash handling system

Ash water system


High pressure water required for bottom ash h o p p e r q u e n c h i n g
n o z z l e s , b o t t o m a s h h o p p e r s p r a yi n g , c l i n k e r grinder
sealing scraper bars, cleaning nozzles, bottom ash hopper s e a l
through flushing, economizer hopper flushing nozzles and
sluicing trench jetting nozzles is tapped from the high
p r e s s u r e water ring mainly provided in the plant area. Low pressure
water required for bottom ash hopper seal through make up, scraper
conveyor make up, flushing a p p a r a t u s j e t t i n g n o z z l e s f o r
a l l f l y a s h h o p p e r s e x c e p t i n g economizer hoppers, is
t r a p p e d f r o m l o w p r e s s u r e wa t e r r i n g s mainly provided in the
plant area.
Ash slurry system
Bottom ash and fly ash slurry of the system is sluiced up to ash pump
along the channel with the acid of high pressure water jets located
at suitable intervals along the channel. Slurry pump suction line
consisting of reducing elbow with drain v a l v e , r e d u c e r a n d

185
b u t t e r f l y v a l v e a n d p o r t i o n o f s l u r r y p u m p delivery line
consisting of butterfly valve, pipe & fitting has also been provided.

Ash slurry pump

Electrostatic Precipitator with fly ash hoppers


186
Ways to increase the thermal efficiency of
power plants:
The basic idea behind all the modifications to increase the thermal
efficiency of a power cycle is the same: Increase the average
temperature at which heat is transferred to the working fluid in the
boiler, or decrease the average temperature at which heat is
rejected from the working fluid in the condenser. That is, the
average fluid temperature should be as high as possible during heat
addition and as low as possible during heat rejection.
Lowering the Condenser Pressure (Lowers Tlow,avg): Steam exists as
a saturated mixture in the condenser at the saturation temperature
corresponding to the pressure inside the condenser. Therefore, lowering
the operating pressure of the condenser automatically lowers the
temperature of the steam, and thus the temperature at which heat is
rejected. The effect of lowering the condenser pressure on the Rankine
cycle efficiency is illustrated on a T-s diagram in Fig.1. For comparison
purposes, the turbine inlet state is maintained the same. The colored
area on this diagram represents the increase in net work output as a
result of lowering the condenser pressure from P4 to P4’. The heat input
requirements also increase (represented by the area under curve 2-2),
but this increase is very small. Thus the overall effect of lowering the
condenser pressure is an increase in the thermal efficiency of the cycle.

187
Effect of lowering of the condenser pressure on efficiency

Superheating the Steam to High Temperatures (Increases Thigh, avg):


The average temperature at which heat is transferred to steam can be
increased without increasing the boiler pressure by superheating the
steam to high temperatures. The effect of superheating on the
performance of vapor power cycles is illustrated on a T-s diagram in
Fig.2. The colored area on this diagram represents the increase in the
net work. The total area under the process curve 3-3 represents the
increase in the heat input. Thus both the net work and heat input
increase as a result of superheating the steam to a higher temperature.
The overall effect is an increase in thermal efficiency, however, since the
average temperature at which heat is added increases.

Effect of superheating the steam to high temperatures


188
Increasing the Boiler Pressure (Increases Thigh, avg): Another way of
increasing the average temperature during the heat-addition process is
to increase the operating pressure of the boiler, which automatically
raises the temperature at which boiling takes place. This, in turn, raises
the average temperature at which heat is transferred to the steam and
thus raises the thermal efficiency of the cycle. The effect of increasing
the boiler pressure on the performance of vapor power cycles is
illustrated on a T-s diagram in Fig.3. Notice that for a fixed turbine inlet
temperature, the cycle shifts to the left and the moisture content of
steam at the turbine exit increases. This undesirable side effect can be
corrected, however, by reheating the steam, as discussed in the next
section.

Effect of increasing boiler pressure to increase efficiency

189
Losses during operation & maintenance of
a power plant
1) SURFACE ROUGHNESS:
It increases friction & resistance. It can be due to Chemical deposits,
Solid particle damage, and Corrosion Pitting & Water erosion. As a
thumb rule, surface roughness of about 0.05 mm can lead to a decrease
in efficiency of 4%.

2) LEAKAGE LOSS:
 Inter stage Leakage
 Turbine end Gland Leakages
 About 2 - 7.5 kW is lost per stage if clearances are increased by
0.025 mm depending upon LP or HP stage.

3) WETNESS LOSS:
 Drag Loss: Due to difference in the velocities of the steam &
water particles, water particles lag behind & can even take
different trajectory leading to losses.
 Sudden condensation can create shock disturbances & hence
losses.
 About 1% wetness leads to 1% loss in stage efficiency.

4) OFF DESIGN LOSSES:

 Losses resulting due to turbine not operating with design terminal


conditions.
 Change in Main Steam pressure & temperature.
190
 Change in HRH pressure & temperature.
 Condenser Back Pressure
 Convergent-Divergent nozzles are more prone to Off Design
losses then Convergent nozzles as shock formation is not there in
convergent nozzles.

5) PARTIAL ADMISSION LOSSES:


 In Impulse turbines, the controlling stage is fed with means of
nozzle boxes, the control valves of which open or close
sequentially.
 At some partial load some nozzle boxes can be partially open /
completely closed.
 Shock formation takes place as rotor blades at some time are full
of steam & at some other moment, devoid of steam leading to
considerable losses.

6) LOSS DUE TO EROSION OF LP LAST STAGE BLADES:


 Erosion of the last stage blades leads to considerable loss of
energy. Also, it is the least efficient stage.
 Erosion in the 10% length of the blade leads to decrease in 0.1%
of efficiency

191
Conclusion
As an undergraduate of GITAM University I would like to say that this
training program is an excellent opportunity for us to get to the ground
level and experience the things that we would have never gained
through going straight into a job. I am grateful to GITAM University and
NTPC Ltd Simhadri for giving us this wonderful opportunity. The main
objective of the industrial training is to provide an opportunity to
undergraduates to identify, observe and practice how engineering is
applicable in the real industry. It is not only to get experience on
technical practices but also to observe management practices and to
interact with fellow workers. It is easy to work with sophisticated
machines, but not with people. The only chance that an undergraduate
has to have this experience is the industrial training period. I feel I got
the maximum out of that experience. Also I learnt the way of work in an
organization, the importance of being punctual, the importance of
maximum commitment, and the importance of team spirit. The training
program having several destinations was a lot more useful than staying
at one place throughout the whole one month. It was an advantage for
me to be in the O & M-MM Division where I have boosted up my skills
and abilities. The conclusion that I can make is that NTPC Ltd Simhadri
is the right place for students to do their industrial training. In my opinion,
I have gained lots of knowledge and experience needed to be successful
in a great engineering challenge, as in my opinion, Engineering is after
all a Challenge, and not a Job.

192

You might also like