PHILOSOPHY OF OPERATION 
 
SADELMI – DEMIN PLANT 
 
HOFUF 
 
 
 
 

2
SECTION ‐ 1 
 FILTERATION SYSTEM 
 
 
The plant can be categorized into following four phases. 
 
1.  Filtration system 
2.  First Stage RO 
3.  Second Stage RO 
4.  DEMIN 
 
1.  FILTRATION SYSTEM: 
 
Description: 
 
In  filtration  system,  there  are  three  filter  feed  pumps  and  an  Automatic  Media 
filter.  
 
General operation philosophy of Filtration system: 
 
The  pumps  feed  the  filter  and  the  treated  water  through  the  filter  will  flow 
towards the first stage RO that is split into two even streams. 
 
The filtration system is comprised of the following. 
 
1.  Filter Feed Pumps 
2.  Automatic Media Filter 
3.  Filter Backwash Pumps 
4.  Air Blower 
5.  Dosing Pump 
 
 
 
 
 
 
 
 

3
1.1 FILTER FEED PUMPS 
 
There are three Filter‐feed pumps as follows. 
 
Filter Feed pump – 1 / P1001 
Filter Feed pump – 2 / P1002 
Filter Feed pump – 3 / P1003 
 
Filter feed pumps operate in two modes: 
 
1.1‐A Automatic Mode: 
 
The selector switch of each pump on the local control panel should be in Remote 
position and HMI Auto position. 
 
Filter feed pumps in Auto mode will be running in two cases. 
 
CASE – I 
 
Filter Feed pumps will run in 2 Duty/ 1 Standby fashion when both the RO first 
stage streams are in operation (Service Mode). In case of single stream operation, 
there will be 1 filter feed pump duty and the other two will be standby. 
 
Feed pump P1001 is designated for Stream A operation whereas Feed pump 1002 
shall be designated for Stream B operation. 
 
Incase  of  failure  of  pump  for  any  respective  stream,  the  third  pump  P1003  will 
take over and there will be a trip indication for the faulty pump. 
 
CASE – II 
 
When a filter undergoes backwash, the feed pump 1003 shall be running during 
Rinsing. 
 
Interlocks: 
 
a)  All filter‐feed pumps will be interlocked with a low level switch in the Raw 
Water Tank to keep from dry – running. 
b)  All filter‐feed pumps will be interlocked with overload signal, as in case of 
overload the pump must stop immediately. 
 

4
1.1‐B Manual Mode: 
 
There are two cases in manual mode. 
 
CASE‐I 
 
The pumps can be operated manually either from the control room or the local 
station. 
 
From Control Room: 
 
The  selector  switch  is  in  Remote  position  on  the  control  panel.  The  selector 
switch for the same pump in the HMI will be in manual. The pump will operate as 
long as the switch remains in manual. Incase of overload or low level in the tank, 
the pump will stop. 
 
From Local Station: 
 
The selector  switch will be in  Local  position  in the  control room,  and the  pump 
will operate with start/stop pushbuttons on the local station near by. 
 
TIP: The HMI will sense the operation of the pump in Manual as described above 
through the feedback signal to the PLC. 
 
FAULTS AND ALARMS ACKNOWLEDGEMENTS: 
 
1.  In case of pump failure during operation for any stream due to overload, 
the respective standby pump will automatically take over without stopping 
the plant and there will only be a trip indication on the local panel in the 
control room. The alarm will be logged. 
 
2.  In  case,  when  both  streams  are  continuingly  running  in  auto  mode  and 
more  than  one  pump  fails,  the  fault  lamp  should  be  lit  and  alarm  must 
annunciate. The system will shutdown, all the valves will close. 
 

5
1.2 AUTOMATIC FILTER 
 
The HMI shall include a separate screen for the filter operation that will have two 
modes of operation for the filter. 
 
1.2‐A Automatic Operation: 
 
For  Automatic  Operation,  the  filter  should  be  put  in  Automatic  mode  from  the 
HMI Filters Screen with the selector (soft) switch. This will allow the two streams 
of  1st  Stage  RO  to  operate  in  complete  Auto  mode.  For  any  stream,  Filter  feed 
pump and high‐pressure pump should also be in Auto position from the HMI and 
Remote position from the MCC. 
 
1.2‐B Manual Operation (From HMI): 
 
For the manual operation of the Filter, the HMI screen for the Automatic Media 
filter  shall have  soft  push  buttons  for  each mode  of  operation  of  the  filter with 
respect to treatment. 
 
In Manual Operation, the filter will be set in Manual mode from the HMI with the 
soft switch and the desired function will be initiated e.g. Backwash, service, rinse, 
air scour from the soft push buttons. 
 
1.2‐C Modes of Operation
 
Automatic Filter has six motorized valves: 
1.  Service Inlet Valve (SIV)    VM1001 
2.  Service Outlet Valve (SOV)    VM1002 
3.  Backwash Inlet Valve (BIV)    VM1003 
4.  Backwash Outlet Valve (BOV)  VM1004 
5.  Rinse Valve (RNV)      VM1006 
6.  Air Scour Valve (ASV)    VM1005 
 
 
 
 
 
 
 
 

6
 
 
 
 
 
 
 
 
 
 
 
 
 
 
We can divide the operation sequence of filter into two modes. This automatic 
sequence will be applicable only when the soft switch in the HMI screen for the 
Automatic Media Filter will be in Automatic operation position. 
 
1.  Service Mode: 
2.  Backwash Mode: 
a.  Drain 
b.  Air Scour 
c.  Backwash 
d.  Rinse 
 
1.2‐C‐1 SERVICE MODE:
 
In this mode, Service inlet valve and service outlet valve will open. Where as, all 
other valves will be closed.  
Service  Backwash  Backwash 
Service Inlet  Rinse  Air Scour 
Outlet  Inlet  Outlet 

OPEN  OPEN  CLOSE  CLOSE  CLOSE  CLOSE 

 
1.2‐C‐2 BACKWASH MODE:  (Total Duration: 25 Minutes) 
 
The  filters  will  be  backwashed  once  the  differential  pressure  switch  closes  to 
confirm the difference in pressure between the filter inlet and outlet point. 
Once the system is in backwash mode, the filter will further go into following four 
steps. 

7
 
Step –1  
 
DRAIN: (Duration: 3 Minutes) 
 
In this mode, Backwash outlet valve and rinse valve will open. Where as, all other 
valves will be closed. 
Service  Backwash  Backwash 
Service Inlet  Rinse  Air Scour 
Outlet  Inlet  Outlet 

CLOSE  CLOSE  CLOSE  OPEN  OPEN  CLOSE 

 
Step –2 
 
AIR SCOUR: (Duration: 3 Minutes) 
 
In this mode, Backwash Outlet valve and Air Scour valve will open. Where as, all 
other valves will be closed. Air blower shall also run. 
Service  Backwash  Backwash 
Service Inlet  Rinse  Air Scour 
Outlet  Inlet  Outlet 

CLOSE  CLOSE  CLOSE  OPEN  CLOSE  OPEN 

*See Air Blower. 
 
Step – 3 
 
BACKWASH: (Duration: 14 Minutes) 
 
In this mode, Backwash inlet valve and Backwash outlet valve will open. Where 
as, all other valves will be closed. 
Service  Backwash  Backwash 
Service Inlet  Rinse  Air Scour 
Outlet  Inlet  Outlet 

CLOSE  CLOSE  OPEN  OPEN  CLOSE  CLOSE 

* See Filter Backwash Pumps. 
Backwash pump must run in the duration of step – 3 (backwash).  
 
 
 

8
Step – 4 
 
RINSE: (Duration: 5 Minutes) 
 
In  this  mode,  Service  inlet  valve  and  Rinse  valve  will  open.  Where  as,  all  other 
valves will be closed. 
Service  Backwash  Backwash 
Service Inlet  Rinse  Air Scour 
Outlet  Inlet  Outlet 

OPEN  CLOSE  CLOSE  CLOSE  OPEN  CLOSE 

 
During  rinse,  the  filter  feed  pump  as  assigned  by  the  present  changeover 
sequence will run. 
 
As soon as Rinse finishes the filters will go back to normal (Service) mode. 
 
1.2‐D PROVISION OF MANUAL BACKWASH FROM HMI:
 
The manual backwash from HMI system will be carried out as follows: 
 
The  filter  should  be  switched  to  Manual  mode  from  the  soft  switch  in  the  HMI 
Screen. 
 
The  soft‐switch  for  manual  backwash  in  the  SCADA  will  get  the  filter  and  RO 
stream out from service mode. 
 
There will be soft‐pushbuttons for Drain, Air scour, Backwash and rinse in SCADA. 
 
During  Rinse  (Step  –4)  and  Backwash  (Step  –3)  in  manual  mode,  the  required 
pumps will also start/stop manually from the HMI. 
 
FAULTS AND ALARMS ACKNOWLEDGEMENTS: 
 
There is an open/close (built in limit switch) feedback fed from each valve to the 
PLC. Every time the valve opens or closes, the limit switch should give feedback 
within the preset time. Incase of failure of any valve there will be an alarm in the 
HMI and the system will go out of service. The Alarm screen will flash the faulty 
valve. The alarm must be acknowledged and cleared before the system goes back 
to service again. 

9
1.3 FILTER BACKWASH PUMPS 
 
There are two Filter‐backwash pumps as follows. 
 
Filter Backwash pump – 1 / P1004 
Filter Backwash pump – 2 / P1005 
 
Filter‐backwash pumps operate in two modes: 
 
1.3‐A Automatic Mode: 
 
The  selector  switch  of  each  pump  on  the  control  panel  should  be  in  Remote 
position and HMI Auto position. 
 
Filter  backwash  pumps  will  run  when  the  filter  is  in  Backwash  Mode  (Step  –3 
Backwash). 
 
Backwash pump will operate in One duty / 1 standby fashion. 
 
Interlocks: 
 
a.  All  backwash  pumps  will  be  interlocked  with  a  low  level  switch  in  the 
Backwash tank to keep from dry – running. 
b.  Each backwash pump will be interlocked with overload signal, as in case of 
overload the pump must stop immediately. 
 
1.3‐B Manual Mode: 
 
There are two cases in manual mode. 
 
CASE‐I 
 
The pumps can be operated manually either from the control room or the local 
station. 
 
From Control Room: 
 
The selector switch is in Remote position on the local control panel. The selector 
switch for the same pump in the HMI will be in manual. The pump will operate as 

10
long as the switch remains in manual. Incase of overload or low level in the tank, 
the pump will stop. 
 
From Local Station: 
 
The selector  switch will be in  Local  position  in the  control room,  and the  pump 
will operate with start/stop pushbuttons on the local station. 
 
TIP: The HMI will sense the operation of the pump in Manual as described above 
through the feedback signal to the PLC. 
 
 
 
FAULTS AND ALARMS ACKNOWLEDGEMENTS: 
 
1.  In case of pump failure during operation due to overload or no feedback 
signal the standby pump will automatically take over without stopping the 
sequence and there will only be a trip indication on the local panel in the 
control room. Alarm will be logged. 
 
 

11
1.4 AIR BLOWER: 
 
There are two Air Blowers as follows. 
 
Air Blower  / AB3001 
 
Air blower operates in two modes: 
 
1.  Automatic Mode 
2.  Manual Mode 
 
1.4‐A Automatic Mode: 
 
The selector switch on the control panel should be in Remote position and HMI 
Auto position. 
 
Air blower will run when a filter is in Backwash Mode (Step –2 Air Scour). 
 
In  case  of  failure  of  the  air  blower  during  operation  due  to  overload  or  by 
emergency stop. Alarm will annunciate and the fault lamp shall be lit. 
 
Interlocks: 
 
a.  The  air  blowers  will  be  interlocked  with  overload  signal,  as  in  case  of 
overload the blower must stop immediately. 
 
1.4‐B Manual Mode: 
 
There are two cases in manual mode. 
 
CASE‐I 
 
The blowers can be operated manually either from the control room or the local 
station. 
 
From Control Room: 
 
The selector switch is in Remote position on the local control panel. The selector 
switch for the same blower in the HMI will be in manual. The blower will operate 
as long as the switch remains in manual. Incase of overload the blower will stop. 

12
From Local Station: 
 
The selector  switch will be in  Local  position  in the  control room,  and the  pump 
will operate with start/stop pushbuttons on the local station. 
 
TIP:  The  HMI  system  will  sense  the  operation  of  the  blower  in  Manual  as 
described above through the feedback signal to the PLC. 
 
 
 
FAULTS AND ALARMS ACKNOWLEDGEMENTS: 
 
1.  In case of blower failure during operation due to overload or no feedback 
signal, there will only be a trip indication on the local panel in the control 
room. The alarm must annunciate. 
 

13
 
 
SECTION ‐ 2 
DOSING PUMPS 
 
 
 
2.1 Operation Modes: 
Dosing pumps shall have a separate HMI screen with respective Auto off Manual 
Soft switches to allow both Auto and Manual operation modes. 
 
Dosing pumps will operate according to the following philosophy. 
 
1.  Pre‐chlorination 
2.  De‐chlorination 
3.  Acid 
4.  Antiscalant 
 
2.2 Pre‐chlorination Dosing Pump: 
 
The  pre‐chlorination  dosing  pump  in  Auto  mode  (HMI  Soft  Switch)  and  Remote 
from the dosing pump control panel will always be interlocked with the filter feed 
pumps auto operation. Whereas in case feed pumps are running in manual, the 
dosing pump should also be operated in manual in the same way from the HMI 
soft switch. 
 
2.3 De‐chlorination & Antiscalant dosing pumps: 
 
Following  cases  shall  be  considered  for  the  operation  of  De‐chlorination  & 
Antiscalant dosing pumps. 
 
2.3‐A Case‐1 
 
The  de‐chlorination  and  Antiscalant  dosing  pumps  in  Auto  mode  (HMI  Soft 
Switch)  and  Remote  from  the  dosing  pump  control  panel  will  always  be 
interlocked  with  the  high  pressure  pump  Auto  operation  in  the  respective 
stream. 

14
2.3‐B Case‐2 
 
The  de‐chlorination  dosing  pump  in  Auto  mode  (HMI  Soft  Switch)  and  Remote 
from  the  dosing  pump  control  panel  will  always  be  interlocked  with  the  Auto 
operation  of  the  filter  feed  pumps  while  the  startup  flushing  or  shutdown 
flushing  (details  will  follow  in  the  next  chapter)  of  the  respective  RO  streams  is 
underway. 
 
Whereas in case high pressure pumps are running in manual, the dosing pumps 
should also be operated in manual in the same way from the HMI soft switch. 
 
* For case‐II, the Antiscalant dosing pump will not be considered. 
 
2.4 Acid dosing pumps: 
 
Acid dosing pumps in Auto mode (HMI Soft Switch) and Remote from the dosing 
pump  control  panel  will  always  be  interlocked  with  the  Auto  operation  of  the 
high pressure pump of the respective stream. 
 
Whereas in case high pressure pumps are running in manual, the dosing pumps 
should also be operated in manual in the same way from the HMI soft switch. 

15
 
SECTION – 3 
FIRST PASS RO STREAMS 
 
 
 
3.1 STAGES OF OPERATION: 
 
The  RO  sequence  can  be  broken  down  to  three  stages  considering  startup  till 
shutdown as below: 
 
1.  Startup flushing 
2.  Service 
3.  Shutdown flushing 
 
The  RO  system  consists  of  two  streams  and  each  includes  following  automatic 
components. 
 
1.  De‐chlorination dosing Pump (As described in previous Section) 
2.  Antiscalant Dosing pump  (As described in previous Section) 
3.  Acid dosing pump (As described in previous Section) 
4.  High Pressure Pump / P1006A , P1007B 
5.  Feed Motorized Valve / VM1007A, VM1010B 
6.  Dump Motorized Valve / VM1008A, VM1011B 
7.  Flush Motorized Valve / VM1009A, VM1012B 
8.  1st Pass Break Tank Level Switch / LS2001 
 
3.2 GENERAL OPERATION PHILOSOPHY OF RO SYSTEM: 
 
For the normal operation, the Filter Feed pumps are put in auto mode (HMI SOFT 
SWITCHES) and Remote position on the control panel, the High‐Pressure Pump is 
also put in auto (HMI SOFT SWITCH) and remote on the control panel, Feed line 
Motorized  valve,  Flush  Line  Motorized  Valve  are  ready  to  receive  open  signal 
and the unit will go in operation. 

16
 
3.2‐A STARTUP FLUSHING 
 
At  first,  startup  flushing  occurs  for  preset  time  duration  (2  min)  considering 
adequate pressure built up before the system goes to service.  
In startup flushing, only feed pumps run, de‐chlorination dosing pumps will inject 
SBS, feed line and flush‐motorized valves are open. 
 
3.2‐B SERVICE 
 
After startup flushing, the unit goes into Service. High‐pressure pump starts.  
Antiscalant  and  Acid  dosing  initiates  whereas  the  de‐chlorination  continuingly 
remains active. Flush Motorized valve closes. 
 
3.2‐C SHUTDOWN FLUSHING 
 
Thus, the system in service keeps topping up the 1st Pass Break tank until the high 
level is reached. At this moment when the tank is topped up fully as limited by 
the level switch, the unit goes into Shutdown Flushing. 
 
During  shutdown  flushing  the  high‐pressure  pump  stops.  Acid  and  Antiscalant 
dosing  shall  be  inactive.  Feed  pump  for  the  respective  stream  will  run 
continuingly  whereas  the  flush  motorized  valve  will  open  again.  The  unit 
undergoes shutdown flushing for the preset duration (e.g. 4 minutes). After the 
shutdown flushing the system is ideal until the 1st Pass Break tank (Product tank) 
level goes down to a preset level. 
 
3.2‐D FAULT SHUTDOWN 
 
Fault shutdown occurs in the following three conditions: 

a)  Very Low/High Pressure 
 
When  the  pressure  in  the  system  is  below  the  low‐pressure  set  point  or 
above  the  high‐pressure  set  point  the  system  will  shutdown  right  away 
with  the  fault  indication  and  alarm  without  shutdown  flushing.  Feed 
pumps, High‐pressure pump and all the dosing pumps will stop. 

17
 
b)  HIGH ORP 
 
When the ORP value reaches the upper limit (Preset 375mV), the system 
will  immediately  shutdown  without  shutdown  flushing,  dump  motorized 
valve  will  open  whereas,  feed  pumps,  high  pressure  pump  and  dosing 
pumps  will  stop.  The  feed  line  Motorized  valve  closes.  There  is  an  alarm 
with fault indication. 

c)  Low level Feed Tank 
 
Incase there is low level (20 %) in the Raw Water Tank, the whole system 
stops  immediately  without  shutdown  flushing  with  Fault  Indication  and 
Alarm. 
 
3.2‐E ALARM 
 
Generated Alarm is going to be logged in the HMI system. The nature of 
alarm can also be interpreted from relative parameters.  

18
3.3 HIGH PRESSURE PUMP 
 
There is one high‐pressure pump in each stream as follows. 
 
High Pressure Pump – Stream A / P1006A 
High Pressure Pump – Stream B / P1007B 
 
High Pressure pumps operate in two modes: 
 
3.3‐A Automatic Mode: 
 
The selector switch of the pump on the local control panel should be in Remote 
position and HMI Auto position. 
 
Interlocks: 
 
a)  High  Pressure  pump  will  be  interlocked  with  the  filter  feed  pump 
operation as the filter feed pump must be running when the high pressure 
pump is in operation. 
b)  The high‐pressure pump will be interlocked with overload signal, as in case 
of overload the pump must stop immediately. 
 
3.3‐B Manual Mode: 
 
There are two cases in manual mode. 
 
CASE‐I 
 
The pumps can be operated manually either from the control room or the local 
station. 
 
From Control Room: 
 
The  selector  switch  is  in  Remote  position  on  the  control  panel.  The  selector 
switch for the same pump in the HMI will be in manual. The pump will operate as 
long as the switch remains in manual. Incase of overload or low level in the tank, 
the pump will stop. 

19
From Local Station: 
 
The selector  switch will be in  Local  position  in the  control room,  and the  pump 
will operate with start/stop pushbuttons on the local station near by. 
 
TIP: The HMI will sense the operation of the pump in Manual as described above 
through the feedback signal to the PLC. 
 
FAULTS AND ALARMS ACKNOWLEDGEMENTS: 
 
a)  In case of pump failure during operation for any stream due to overload, 
the respective pump must immediately stop and the stream will be out of 
service with alarm and fault indication. 
 
b)  The alarm must be acknowledged and Reset in order to bring the system 
back in operation. 

20
SECTION – 4 
SECOND PASS RO STREAMS 

4.1 GENERAL DESCRIPTION:
 
The  second  pass  RO  operates  when  the  high‐pressure  pump  is  in  Auto  mode 
(HMI Soft switch) and the Flush motorized valve is ready to operate automatically 
for the respective stream. 
 
The Second pass RO consists of following automatic components. 
 
1.  High Pressure Pumps / P2001A, P2002B 
2.  Flush Motorized Valve / VM2001A, VM2002B 
3.  Mixed Bed Feed Tank Level Switch / LS3001 
 
4.1‐A STARTUP 
 
Every  time  the  unit  starts,  the  flushing  motorized  valve  will  open  for  2  minutes 
startup  flushing  where  as  the  high  pressure  pump  will  remain  stopped.  After 
startup flushing, flush‐motorized valve will close and the high pressure pump will 
start and continue till the Mixed Bed tank is topped up and there is no low level 
in the 1st pass break tank or until and unless the high pressure pump is switched 
off from the Automatic operation. 
 
4.1‐B SHUTDOWN 
 
There will be two cases in the shutdown of the plant as follows. 
 
CASE‐I 
 
When  the  high‐pressure  pump  is  switched  from  remote  to  off  position  or  from 
Auto  to  off  position  in  the  HMI,  the  high‐pressure  pump  will  immediately  stop 
and  the  flush  motorized  opens  again  for  4  minutes.  After  4  minutes  the  flush‐
motorized valve is closed and the system is ideal. 
 
CASE‐II 
 
The  high  level  is  reached  in  the  Mixed  bed  Tank,  the  system  will  undergo  the 
same shutdown sequence as in Case‐I. 

21
 
 
4.2 HIGH PRESSURE PUMP 
 
There is one high‐pressure pump in each stream as follows. 
 
High Pressure Pump – Stream A / P2001A 
High Pressure Pump – Stream B / P2002B 
 
High Pressure pumps operate in two modes: 
 
4.2‐A Automatic Mode: 
 
The selector switch of the pump on the local control panel should be in Remote 
position and HMI Auto position. 
 
Interlocks: 
 
The  high‐pressure  pump  will  be  interlocked  with  overload  signal,  as  in  case  of 
overload the pump must stop immediately. 
 
4.2‐B Manual Mode: 
 
There are two cases in manual mode. 
 
CASE‐I 
 
The pumps can be operated manually either from the control room or the local 
station. 
 
From Control Room: 
 
The  selector  switch  is  in  Remote  position  on  the  control  panel.  The  selector 
switch for the same pump in the HMI will be in manual. The pump will operate as 
long as the switch remains in manual. Incase of overload or low level in the tank, 
the pump will stop. 

22
From Local Station: 
 
The selector  switch will be in  Local  position  in the  control room,  and the  pump 
will operate with start/stop pushbuttons on the local station near by. 
 
TIP: The HMI will sense the operation of the pump in Manual as described above 
through the feedback signal to the PLC. 
 
FAULTS AND ALARMS ACKNOWLEDGEMENTS: 
 
a)  In case of pump failure during operation for any stream due to overload, 
the respective pump must immediately stop and the stream will be out of 
service with alarm and fault indication. 
 
b)  The alarm must be acknowledged and Reset in order to bring the system 
back in operation. 
 
4.3 FAULT SHUTDOWN 
 
Fault shutdown occurs in the following three conditions: 

a)  Very Low/High Pressure 
 
When  the  pressure  in  the  system  is  below  the  low‐pressure  set  point  or 
above  the  high‐pressure  set  point  the  system  will  shutdown  right  away 
with  the  fault  indication  and  alarm  without  shutdown  flushing.  Feed 
pumps, High‐pressure pump and all the dosing pumps will stop. 
 
 
b)  Low level Feed Tank 
 
Incase  there  is  low  level  (20  %)  in  the  1st  Pass  Break  Tank,  the  whole 
system stops immediately without shutdown flushing with Fault Indication 
and Alarm. 
 
3.2‐E ALARM 
 
Generated Alarm is going to be logged in the HMI system. The nature of alarm 
can also be interpreted from relative parameters. 