650 VA - 800 kVA
Contemporary business conditions force companies to have higher accuracy, and ELEN solidly fulfills its
share of duty in this challenging environment. Founded in 1988, ELEN is a fast growing Uninterruptible
Power Supply (UPS) manufacturing company, focused on R&D and production of UPS Systems. For a large
variety of utilization purposes, ELEN provides increased performance, reliability, and minimum total-life
cost of UPS. Its unique solutions raise the bar and therefore, strengthen ELEN’s consistency as a
worldwide-known brand. Located in Istanbul, Turkey, ELEN manufactures UPS Systems for more than 50
countries covering 5 continents. For satisfaction at the highest degree, the Company provides versatile
products tailored for customers by its 300 employees. Right along with the effort to understand the customer
needs, ELEN shows its meticulousness also in the manufacturing process, and produces all the components
including the metal parts. With the efforts of its R&D department of 30 researchers, ELEN strives to offer
innovative solutions in energy sector to meet the global needs. Acknowledged for its continuous innovation,
ELEN collects and combines the feedbacks in different utilization fields to improve its corporate culture.
Pursuing this ambition, ELEN considers itself as the best candidate to be your partner in power protection.
Certificates
Single Phase X X
Single Phase X X 93
Single Phase X X
A4 Single Phase X X
Three/Single Phase X X
Three/Single Phase X X
Three Phase X
Three Phase X
Three Phase X 94 95
Three Phase X 94 95
Three Phase X 94 95
Three Phase 94 95
CONNECTED TO DC BUSBAR
E1 Series 10-20 kVA Three Phase
Three Level Inverter
Digital Power Factor Correction
NEW TECHNOLOGY
Three level inverter
High and stable online efficiency (up to 94%)
High input PF (≥0.99)
Low input current THD (≤5%)
Low output voltage THD (≤2%)
Short response time (≤2ms)
High input and output performance
RELIABLE & USER FRIENDLY
Parallel option up to 4 units
Intelligent redundancy management (n, n+1 and n+x)
Programmable high overload capacity
Short circuit protection
Low investment and operation cost
Short return on investment time
Highest efficiency eco-mode (up to 98%)
Reduced weight/volume/footprint
Wide input voltage tolerances (-25%, +20%)
Energy-saving sleep mode
Short circuit, lightning and surge protection
Remote emergency power off (EPO)
Generator compatibility
1-7A adjustable battery charger
Extended battery life with intelligent battery management
Automatic and manual battery test
LCD interface
Remote monitoring panel (optional)
512 real time event log
Battery capacity, load percentage and ambient temperature display
SNMP (optional), RS232, RS485, Modem, MODBUS communication
Remote monitoring and management software
Dry contacts and custom inputs
Smart fan control
Internal battery
Manual bypass
Easy installation and maintenance
10-year spare part availability
7/24 technical support and customer service
STANDARDS
EN 62040-1 (Safety)
EN 62040-2 (EMC)
EN 62040-3
CE, ISO 9001:2008, ISO 14001, GOST
E1 SERIES
UPS TECHNICAL SPECIFICATIONS
Sn (kVA) 10 15 20
POWER
≤ %110 60 min.
OVERLOAD
≤ %125 10 min.
CAPACITY
≤ %150 1 min.
Online
EFFICIENCY
Eco-mode
Safety EN 62040-1
STANDARDS
EMC EN 62040-2
Performance EN 62040-3
NEW TECHNOLOGY
Three level topology
High and stable online efficiency (up to 95%)
High input PF ( ≥0.99)
Low input current THD (≤4%)
High output PF (0.9)
Low output voltage THD (≤2%)
Short response time (≤2ms)
High input and output performance
RELIABLE
Parallel option up to 6 units
Intelligent redundancy management (n, n+1 and n+x)
After failure, high efficiency and safety test with regenerative mode
Wide input voltage tolerances (-25%,+20%)
Variable input low voltage depending on loading percentage (up to -36%)
Automatic soft-start
Adjustable rectifier soft-start time
Cold start
From panel and remote emergency power off
Short circuit, lightning and surge protection
USER-FRIENDLY
Low investment and operating cost
Short return on investment time
Higher efficiency with eco-mode (up to 98%)
Reduced weight/volume/footprint
Touch screen TFT LCD user interface
Multi language options up to 10 languages
Advance data and event log
1024 real time event log and easy download
Data analyzing over user interface
Multi communication options
RS232/RS485 (standard)
USB Port (standard)
SNMP (standard)
Advance monitoring options (standard)
Remote monitoring and management software
Programmable dry contacts
Optimum generator compatibility
Long battery life with intelligent battery management
Flexible battery count
Automatic and manual battery test
Smart fan control
10-year spare part availability
7/24 technical support and customer service
STANDARDS
EN 62040-1 (Safety)
EN 62040-2 (EMC)
CE, ISO 9001:2008, ISO 14001, GOST
E2 SERIES
UPS TECHNICAL SPECIFICATIONS
Sn (kVA) 30 60 90 120 160 200
POWER
Pn (kW) 27 54 81 108 144 180
Voltage 380 / 400 / 415 Vac 3- ph + N
Voltage Tolerances -%15, +%20 (without downgrading), -%36 (depending on load percentage)
Frequency 50 / 60 Hz
INPUT Frequency Tolerances ± %10
Power Factor ≥ 0,99
THDi <%4
Dual Input Optional
Voltage 380 /400 / 415 Vac 3-ph + N
Voltage tolerances Adjustable up to -25%, +20%
BYPASS
Frequency 50/60 Hz
Frequency tolerances adjustable up to ± 10%
Maintenance bypass Standard
Voltage 380 /400 / 415 Vac 3-ph + N
Voltage tolerances ± %1 (static load), ± %5 (dynamic load)
Frequency 50/60 Hz (selectable)
OUTPUT Frequency tolerances ± % 0,1 (self-synchronize), ± %1 (mains-synchronize, adjustable up to ± 5%)
Power Factor 0,9
THDv < 2% (linear load), < 5% (non-linear load)
Crest Factor 3:1
≤ %110 60 min.
OVERLOAD
≤ %125 10 min.
CAPACITY
≤ %150 1 min.
%100 Load up to %95
Online
EFFICIENCY %50 Load up to %95
Eco-mod %98
Technology Three level IGBT rectifier & inverter
Control DSP, SPWM
Classification in accordance with EN 62040-3 VFI - SS - 111(Voltage Frequency Independent)
Paralleling Units Up to 6
Communication SNMP(Optional), USB, RS232, RS485, MODBUS
GENERAL Remote Monitoring Remote panel(Optional)
Programmable Dry Contacts 3 (standard)
Programmable Custom Inputs 4
Charge With Temperature Compensation Optional
Cold Start Standard
Touch Screen TFT LCD User Interface Standard
Operating temperature from 0 °C up to +40 °C (from 20 °C to 25 °C for maximum battery life)
Relative humidity 0% - 95% (without condensation)
ENVIRONMENT
Maximum altitude ≤ 2000 m
Noise Level (dB (A)) <60 <65 <70
W (mm) 480 480 480 480 480 480
Dimensions D (mm) 750 1050 590 900 1000 1060
UPS CABINET H (mm) 1090 1090 1225 1225 1225 1850
Degree of Protection IP20
Colour RAL9005
Battery Quantity 40 ± 4 (adjustable)
Type VRLA AGM
BATTERY
Internal Battery Quantity (max.) 40 -
Internal Battery Capacity (Ah) 7-9 -
Safety EN 62040-1
STANDARDS
EMC EN 62040-2
UPS LIFETIME 10 Years
ELEN reserves the right, at its sole discretion, to change, amend and modify the information given above without prior notice.
E3 Series 250-800 kVA Three phase
Three Level IGBT Rectifier & Inverter
Digital Signal Processing (DSP) Technology
NEW TECHNOLOGY
Three level topology
High and stable online efficiency (up to 95,5%)
High input PF ( ≥0.99)
Low input current THD ( ≤%4)
High output PF (0.9)
Low output voltage THD ( ≤2%)
Short response time (≤2ms)
High input and output performance
RELIABLE
Parallel option up to 6 units
Intelligent redundancy management (n, n+1 and n+x)
Variable input low voltage depending on loading percentage (up to -36%)
Programmable high overload capacity
Short circuit protection
Local and remote emergency power off
External bypass (Optional)
Optimum generator compatibility
USER-FRIENDLY
Low investment and operating cost
Short return on investment time
Reduced weight/volume/footprint
Higher efficiency with eco-mode (up to 98%)
Self-loading (regenerative mode)
Adjustable input / output voltage & selectable frequency
Extended battery life with intelligent battery management
Automatic and manual battery test with adjustable period and duration
o Touch screen TFT LCD user interface
RS232/RS485
USB Port
SNMP
Advance monitoring options
1024 real time event log and easy download
Multi language options
Remote monitoring and management software
Programmable dry contacts
Custom inputs
Maintenance bypass
Easy installation and maintenance
10-year spare part availability
E3 SERIES
UPS TECHNICAL SPECIFICATIONS
Sn (kVA) 250 300 400 500 600 800 1000
POWER
Pn (kW) 225 270 360 450 540 720 900
Voltage 380 / 400 / 415 Vac 3-ph + N
Voltage Tolerances ± 15% (without downgrading), -36% (depending on load percentage)
Frequency 50 / 60 Hz
INPUT Frequency Tolerances ± 10%
Power Factor ≥ 0,99
THDi < 3%
Dual Input Optional
Voltage 380 / 400 / 415 Vac 3-ph + N
Voltage tolerances ± 10% (adjustable)
BYPASS
Frequency 50 / 60 Hz
Frequency tolerances ± 4% (adjustable up to ± 10%)
Maintenance Bypass Standard Standard
Voltage 380 / 400 / 415 Vac 3-ph + N
Voltage tolerances ± 1% (static load), ± 5% (dynamic load)
Frequency 50 / 60 Hz (selectable)
OUTPUT Frequency tolerances ± 0.1% (self-synchronize), ± 1% (mains-synchronize, adjustable up to ± 5%)
Power Factor 0,9
THDv < 2% (linear load), < 5% (non-linear load)
Crest Factor 3:1
≤ %110 60 min.
OVERLOAD
≤ %125 10 min.
CAPACITY
≤ %150 1 min.
%100 Load %95,5
Online
EFFICIENCY %50 Load %95
Eco-mod %98
Technology Three level rectifier & inverter
Control DSP, SPWM
Classification in accordance with EN 62040-3 VFI - SS - 111(Voltage Frequency Independent)
Paralleling Units Up to 6
GENERAL Communication SNMP, USB, RS232, RS485, MODBUS
Remote Monitoring Remote monitoring panel(Optional)
Dry Contacts Programmable 3 dry contacts
Custom Inputs Generator, Battery temperature sensor, Remote EPO, Remote Start/Stop
Touch Screen TFT LCD User Interface Standard
Operating Temperature from 0 °C up to +40 °C (from 20 °C to 25 °C for maximum battery life)
Relative Humidity 0% - 95% (without condensation)
ENVIRONMENT
Maximum Altitude ≤ 2000 m
Noise level dB(A) <70 <75
W (mm) 705 705 705 705
Dimensions D (mm) 1260 2150 3350 4250
UPS CABINET H (mm) 1600 1600 1600 1600
Weight (kg) 850 1000 1380 1600 1700
Degree of Protection IP20
Colour RAL9005
Battery Quantity 56
BATTERY
Type VRLA AGM
Safety EN 62040-1
STANDARDS
EMC EN 62040-2
UPS LIFETIME 10 Years
ELEN reserves the right, at its sole discretion, to change, amend and modify the information given above without prior notice.
E4 Series 20-120 kVA Three phase
Modular Technology
Hot-Swappable Modules
Three Level IGBT Rectifier & Inverter
DSP Control
NEW TECHNOLOGY
Three level topology
High and stable online efficiency (up to 94,5%)
High input PF ( ≥0.99)
Low input current THD ( ≤4%)
Low output voltage THD ( ≤2%)
Short response time (≤2ms)
High input and output performance
RELIABLE
Multi-master paralleling
Hot-swappable power and battery modules
Increasing power capacity or back-up time without any risks of downtime
High flexibility, maximum availability and reduced mean time to repair (MTTR)
Self-loading (regenerative mode) for safe tests after repair and high efficiency loading tests
Wide input voltage tolerances (-25%, +%20)
Variable input low voltage depending on loading percentage (up to -36%)
Automatic soft-start
Adjustable rectifier soft-start period
Local and remote emergency power off (EPO)
Short circuit, lightning and surge protection
USER-FRIENDLY
Low operating and cooling cost
Short return on investment (ROI) time
Higher efficiency with eco-mode (up to 98%)
Reduced weight/volume/footprint
Touch screen TFT LCD user interface
Multi language options
Advanced data, event logging and analyzing over user interface
1024 real time event log and easy download
Data analysis via panel
Multi communication options
RS232/RS485 (standard)
USB Port (standard)
SNMP (standard)
Advance monitoring options (standard)
Remote monitoring and management
Programmable dry contacts and programmable custom inputs
Optimum generator compatibility
Long battery life with intelligent battery management
Flexible battery count
Automatic and manual battery test
Smart fan control
10-year spare part availability
7/24 technical support and customer service
STANDARDS
EN 62040-1 (Safety)
EN 62040-2 (EMC)
CE, ISO 9001:2008, ISO 14001, GOST
E4 SERIES
UPS TECHNICAL SPECIFICATIONS
Module 1 2 3 4 5 6
Sn (kVA) 20 40 60 80 100 120
POWER
Pn (kW) 18 36 54 72 90 108
Voltage 380 / 400 / 415 Vac 3-ph + N
Voltage Tolerances - 25%, +20% (without downgrading), -36% (depending on load percentage)
Frequency 50 / 60 Hz
INPUT
Frequency Tolerances ± 10%
Power Factor ≥ 0,99
THDi < 4%
External Bypass Optional
Voltage 380 / 400 / 415 Vac 3-ph + N
Voltage Tolerances up to - 25%, +20% (adjustable)
BYPASS
Frequency 50 / 60 Hz
Frequency Tolerances up to ± 10% (adjustable)
Maintenance Bypass Standard
Voltage 380 / 400 / 415 Vac 3-ph + N
Voltage Tolerances ± 1% (static load), ± 5% (dynamic load)
Frequency 50 / 60 Hz (selectable)
OUTPUT Frequency Tolerances ± 0.1% (self-synchronize), ± 1% (bypass-synchronize, adjustable up to ± 5%)
Power Factor 0,9
THDv < 2% (linear load), < 5% (non-linear load)
Crest Factor 3:1
≤ %110 60 min.
OVERLOAD
≤ %125 10 min.
CAPACITY
≤ %150 1 min.
%100 Load %95
Online
EFFICIENCY %50 Load %94,5
Eco-mode %98
Technology Three level rectifier & inverter, Hot-swappable modular
Control DSP, SPWM
Classification in accordance with EN 62040-3 VFI - SS - 111(Voltage Frequency Independent)
Communication SNMP, USB, RS232, RS485, MODBUS
Remote Monitoring Remote monitoring panel (optional)
GENERAL Programmable Dry Contacts 3 (standard), 7 (optional)
Programmable Custom Inputs 4
Temperature Compensated Charge Optional
Touchscreen TFT LCD Display Standard
Safety EN 62040-1
STANDARDS
EMC EN 62040-2
UPS LIFETIME 10 Years
ELEN reserves the right, at its sole discretion, to change, amend and modify the information given above without prior notice.
D1 Series 160-800 kVA Three phase
IGBT Rectifier
Digital Signal Processing (DSP) Technology
NEW TECHNOLOGY
IGBT rectifier
High efficiency (up to 92%)
High input PF (≥0.99)
Low input current THD (≤4%)
Low output voltage THD (≤2%)
Short response time (≤2ms)
High input and output performance
RELIABLE
Parallel option up to 6 units
Intelligent redundancy management (n, n+1 and n+x)
Variable input low voltage depending on loading percentage (up to -36%)
Programmable high overload capacity
Short circuit protection
Local and remote emergency power off
Dual input(Optional)
Optimum generator compatibility
USER-FRIENDLY
Reduced weight/volume/footprint
Higher efficiency with eco-mode (up to 98%)
Self-loading (regenerative mode)
Adjustable input / output voltage & selectable frequency
Extended battery life with intelligent battery management
Automatic and manual battery test with adjustable period and duration
Touch screen TFT LCD user interface (optional for 400-500-600 kVA)
RS232/RS485 (standard)
USB Port (standard)
SNMP (standard)
• Advance monitoring optiones (standard)
1024 real time event log and easy download
Multi language options up to 10 languages
512 real time event log and easy download
Multi communication options
Remote monitoring and management software
Programmable dry contacts
Custom inputs
Maintenance bypass
Easy installation and maintenance
10-year spare part availability
7/24 technical support and customer service
STANDARDS
EN 62040-1 (Safety)
EN 62040-2 (EMC)
CE, ISO 9001:2008, ISO 14001,GOST
D1 SERIES
UPS TECHNICAL SPECIFICATIONS
Sn (kVA) 160 200 250 300 400 500 600 800 1000
POWER
Pn (kW) 128 160 200 240 320 400 480 640 800
Voltage 380 / 400 / 415 Vac 3- ph + N
Voltage Tolerances ± 15% (without downgrading), -36% (depending on load percentage)
Frequency 50 / 60 Hz
INPUT Frequency Tolerances ± %10
Power Factor ≥ 0,99
THDi <%4
Dual input Optional
Voltage 380 /400 / 415 Vac 3-ph + N
Voltage Tolerances ± %10 (adjustable)
BYPASS
Frequency 50/60 Hz
Frequency Tolerances ± %4 (adjustable up to ± 10%)
Maintenance Bypass Standard
Voltage 380 /400 / 415 Vac 3-ph + N
Voltage Tolerances ± 1% (static load), dynamic load in accordance with VFI-SS-11
Frequency 50/60 Hz (selectable)
OUTPUT Frequency Tolerances ± 0.1% (self-synchronize), ± 4% (mains-synchronize, adjustable up to ± 5%)
Power Factor 0,8 (0,9 optional)
THDv < 2% (linear load), < 5% (non-linear load)
Crest Factor 3:1
≤ %110 up to 60 min.
OVERLOAD
≤ %125 up to 10 min.
CAPACITY
≤ %150 up to 1 min.
Online up to %92
EFFICIENCY
Eco-mod up to %98
Technology True online-double conversion, IGBT rectifier
Control DSP, SPWM
Paralleling units up to 6
Communication SNMP, USB, RS232, RS485, MODBUS
GENERAL Remote monitoring Remote panel (Optional)
Dry contacts Programmable 7 dry contacts
Custom inputs Generator, Battery temperature sensor, Remote EPO
Touchscreen TFT LCD Display Optional
NEW TECHNOLOGY
IGBT rectifier
High efficiency (up to 92%)
High input PF (≥0.99)
Low input current THD (≤4%)
Low output voltage THD (≤2%)
Short response time (≤2ms)
High input and output performance
RELIABLE
Parallel option up to 6 units
Intelligent redundancy management (n, n+1 and n+x)
Variable input low voltage depending on loading percentage (up to -36%)
Programmable high overload capacity
Short circuit protection
Remote emergency power off
Dual input(Optional)
Optimum generator compatibility
USER-FRIENDLY
Reduced weight/volume/footprint
Higher efficiency with eco-mode (up to 98%)
Self-loading (regenerative mode)
Adjustable input / output voltage & selectable frequency
Extended battery life with intelligent battery management
Automatic and manual battery test with adjustable period and duration
User-friendly LCD interface
Multi language options up to 10 languages
512 real time event log and easy download
Multi communication options
Remote monitoring and management software
Programmable dry contacts
Custom inputs
Manual bypass
Easy installation and maintenance
10-year spare part availability
7/24 technical support and customer service
STANDARDS
EN 62040-1 (Safety)
EN 62040-2 (EMC)
CE, ISO 9001:2008, ISO 14001, GOST
C1 SERIES
UPS TECHNICAL SPECIFICATIONS
Sn (kVA) 30 40 60 80 100 120
POWER
Pn (kW) 24 32 48 64 80 96
NEW TECHNOLOGY
ThreeThree level inverter
High and stable online efficiency (up to 94%)
High input PF (≥0.95)
Low output voltage THD (≤2%)
Short response time (≤2ms)
High input and output performance
RELIABLE & USER FRIENDLY
Low investment and operation cost
Short return on investment time
Reduced weight/volume/footprint
Wide input voltage tolerances (- 25%, +20%)
Cold start
Energy-saving sleep mode
Short circuit, lightning and surge protection
Remote emergency power off (EPO)
Generator compatibility
1-5A adjustable charger (optional)
Extended battery life with intelligent battery management
Automatic battery test
LCD interface and LED operation mode indicator
Remote monitoring panel (optional)
128 event log
Battery capacity and load percentage display
SNMP (optional) and RS232 communication
Remote monitoring and management software
Dry contacts
Internal battery
Easy installation and maintenance
5-year spare part availability
7/24 technical support and customer service
STANDARDS
EN 62040-1 (Safety)
EN 62040-2 (EMC)
CE, ISO 9001:2008, ISO 14001, GOST
B1 SERIES
UPS TECHNICAL SPECIFICATIONS
POWER 10
≤ %110 30 min.
OVERLOAD ≤ %125 60 sec.
CAPACITY
≤ %150 10 sec.
Battery quantity 20 30
BATTERY Battery capacity (Ah) 7-9
External Battery Cabinet Socket Standard
Safety EN 62040-1
STANDARDS
EMC EN 62040-2
ELEN reserves the right, at its sole discretion, to change, amend and modify the information given above without prior notice.
B2 Series 10-15-20 kVA Three-Single phase
Three Level Inverter
Digital Power Factor Correction
NEW TECHNOLOGY
Three level inverter
High and stable online efficiency (up to 94%)
High input PF (≥0.99)
Low input current THD (≤5%)
Low output voltage THD (≤2%)
Short response time (≤2ms)
High input and output performance
RELIABLE & USER FRIENDLY
Programmable high overload capacity
Short circuit protection
Low investment and operation cost
Short return on investment time
Highest efficiency eco-mode (up to 98%)
Reduced weight/volume/footprint
Wide input voltage tolerances (-25%, +20%)
Energy-saving sleep mode
Short circuit, lightning and surge protection
Remote emergency power off (EPO)
Generator compatibility
1-7A adjustable battery charger
Extended battery life with intelligent battery management
Automatic and manual battery test
LCD interface and LED operation mode diagram
Remote monitoring panel (optional)
512 real time event log
Battery capacity, load percentage and ambient temperature display
SNMP (optional), RS232, RS485, Modem, MODBUS communication
Remote monitoring and management software
Dry contacts and custom inputs
Internal battery
Manual bypass
Easy installation and maintenance
10-year spare part availability
7/24 technical support and customer service
STANDARDS
EN 62040-1 (Safety)
EN 62040-2 (EMC)
CE, ISO 9001:2008, ISO 14001, GOST
B2 SERIES
UPS TECHNICAL SPECIFICATIONS
POWER kVA 10 15 20
≤ %110 30 min.
OVERLOAD ≤ %130 10 min.
CAPACITY
≤ %150 1 min.
Online up to
EFFICIENCY
Eco-mode up to
Safety EN 62040-1
STANDARDS
EMC EN 62040-2
ELEN reserves the right, at its sole discretion, to change, amend and modify the information given above without prior notice.
A1 Series 1-2- 3 kVA Single Phase
Online
Power Factor Correction
≤ %110 30 min.
Safety EN 62040-1
STANDARDS
EMC EN 62040-2
ELEN reserves the right, at its sole discretion, to change, amend and modify the information given above without prior notice.
A2 Series 6-10 kVA Single Phase
Three Level IGBT Inverter
Power Factor Correction
NEW TECHNOLOGY
Three level inverter
High and stable online efficiency (up to 94%)
High input PF (≥0.99)
Low input current THD (≤5%)
Low output voltage THD (≤2%)
Short response time (≤2ms)
High input and output performance
RELIABLE & USER FRIENDLY
Low investment and operating cost
Short return on investment time
Reduced weight/volume/footprint
Wide input voltage tolerances (-25%, +20%)
Cold start
Energy-saving sleep mode
Short circuit, lightning and surge protection
Remote emergency power off (EPO)
Generator compatibility
1-5A adjustable charger (optional)
Extended battery life with intelligent battery management
Automatic battery test
LCD interface and LED operation mode indicator
Remote monitoring panel (optional)
128 event log
Battery capacity and load percentage display
SNMP (optional) and RS232 communication
Remote monitoring and management software
Dry contacts
Smart fan control
Internal battery
Easy maintenance
5-year spare part availability
7/24 technical support and customer service
STANDARDS
EN 62040-1 (Safety)
EN 62040-2 (EMC)
CE, ISO 9001:2008, ISO 14001, GOST
A2 SERIES
UPS TECHNICAL SPECIFICATIONS
POWER (kVA) 6 10
≤ %110 30 min.
Safety EN 62040-1
STANDARDS
EMC EN 62040-2
ELEN reserves the right, at its sole discretion, to change, amend and modify the information given above without prior notice.
A3 Series10-15-20 kVA Single Phase
Three Level IGBT Inverter
Digital Power Factor Correction
NEW TECHNOLOGY
Three level inverter
High and stable online efficiency (up to 94%)
High input PF ( ≥0.99)
Low input current THD (≤5%)
Low output voltage THD (≤2%)
Short response time (≤2ms)
High input and output performance
RELIABLE & USER FRIENDLY
Programmable high overload capacity
Short circuit protection
Low investment and operation cost
Short return on investment time
Highest efficiency eco-mode (up to 98%)
Reduced weight/volume/footprint
Wide input voltage tolerances (-25%, +20%)
Energy-saving sleep mode
Short circuit, lightning and surge protection
Remote emergency power off (EPO)
Generator compatibility
1-7A adjustable battery charger
Extended battery life with intelligent battery management
Automatic and manual battery test
LCD interface and LED operation mode diagram
Remote monitoring panel (optional)
512 real time event log
Battery capacity, load percentage and ambient temperature display
SNMP (optional), RS232, Modem, MODBUS communication
Remote monitoring and management software
Dry contacts and custom inputs
Smart fan control
Internal battery
Manual bypass
Easy installation and maintenance
5-year spare part availability
7/24 technical support and customer service
STANDARDS
EN 62040-1 (Safety)
EN 62040-2 (EMC)
CE, ISO 9001:2008, ISO 14001, GOST
A3 SERIES
UPS TECHNICAL SPECIFICATIONS
POWER (kVA) 10 15 20
≤ %110 30 min.
≤ %130 1 min.
OVERLOAD
CAPACITY ≤ %150 10 sec.
Online %94
EFFICIENCY
Eco-mode %98
Safety EN 62040-1
STANDARTS
EMC EN 62040-2
ELEN reserves the right, at its sole discretion, to change, amend and modify the information given above without prior notice.
A4 Series 1 - 10 kVA Single Phase
Three Level IGBT Inverter
Digital Power Factor Correction
Rack and Tower Usage
NEW TECHNOLOGY
Three level inverter
High and stable online efficiency (up to 94%)
High input PF ( ≥0.99)
Low input current THD (≤5%)
Low output voltage THD (≤2%)
Short response time (≤2ms)
High input and output performance
RELIABLE & USER FRIENDLY
Can be installed on the floor or in rack cabinets for networking applications
Rotatable display
Low investment and operation cost
Short return on investment time
Reduced weight/volume/footprint
Wide input voltage tolerances (-25%, +20%)
Energy-saving sleep mode
Short circuit, lightning and surge protection
Remote emergency power off (EPO)
Extended battery life with intelligent battery management
Automatic and manual battery test
LCD interface and LED operation mode diagram
Remote monitoring panel (optional)
128 real time event log
Battery capacity, load percentage and ambient temperature display
SNMP (optional), RS232 communication
Remote monitoring and management software
Dry contacts and custom inputs
Internal battery
Easy installation and maintenance
5-year spare part availability
7/24 technical support and customer service
STANDARDS
EN 62040-1 (Safety)
EN 62040-2 (EMC)
CE, ISO 9001:2008, ISO 14001, GOST
A4 SERIES
UPS TECHNICAL SPECIFICATIONS
POWER 1 2 3 6 10
≤ %110 30 min.
OVERLOAD ≤ %125 1 min.
CAPACITY
≤ %150 10 min.
Dimensions (WxDxH) (mm) Tower 131 x 600 x 437 131 x 600 x 437
Rack 482 (19”) x 600 x 131 (3U) 482 (19”) x 600 x 131 (3U)
Safety EN 62040-1
STANDARD
EMC EN 62040-2
ELEN reserves the right, at its sole discretion, to change, amend and modify the information given above without prior notice.
L1 Series 650 VA -1250VA
Line - Interactive
Cold start
Silent operation
Easy installation
STANDARDS
EN 62040-1 (Safety)
EN 62040-2 (EMC)
110% Continuously
Technology Line-Interactive
Control Microprocessor
Communication not available USB (standard), RS232 (optional)
Transfer time < 5ms < 5ms
GENERAL Remote monitoring UPSilon UPSilon
Cold start Standard Standard
Power inlet IEC320-C13/C14 IEC320 - C13 / C14
Power outlet 1 x F-type 4 x F-type 1 x F-type 4 x F-type
Safety EN 62040-1
STANDARDS
EMC EN 62040-2
*1 PC: computer case + 17'' LCD Monitor
ELEN reserves the right, at its sole discretion, to change, amend and modify the information given above without prior notice.
L2 Series 1 - 3kVA
Line - Interactive
Sine Wave
Cold Start
Silent operation
Internal battery
STANDARDS
EN 62040-1 (Safety)
EN 62040-2 (EMC)
110% 30 min.
Technology Line-Interactive
Control Microprocessor
Communication SNMP(Optional), RS232
GENERAL
Transfer time < 5ms
Remote monitoring SNMPView, UPSilon
Cold start Standard
Safety EN 62040-1
STANDARDS
EMC EN 62040-2
ELEN reserves the right, at its sole discretion, to change, amend and modify the information given above without prior notice.
R1 Series 6 - 30kVA - Single Phase
SERVO VOLTAGE STABILIZER
Microprocessor Control
User Friendly
High Safety
TECHNOLOGY
High efficiency
Steady operation
Maximum sensibility
RELIABLE
Automatic Activation
Overload protection
USER FRIENDLY
Reduced weight/volume/footprint
Multilanguage option
Fan backup
2-year warranty
STANDARDS
TECHNICAL SPECIFICATIONS
POWER (kVA) 6 10 15 20 30
VOLTAGE
Frequency 50 / 60 Hz
Output Voltage 220V
Output Voltage tolerances Adjustable between ±1% and ±5%
Regulation Speed (V/sn) 80 40
%110 30 min.
OVERLOAD
%125 10 min.
CAPATICY
%150 1 min.
Overload
Protection
General Failure
Output Protection Contactor Standard
Control Microprocessor
Graphic LCD Panel Standard
Input
Output
Indicators with light Input
Overload
GENERAL General Failure
True RMS Input Voltage
True RMS Output Voltage
Measurements True RMS Output Current
Frequency
Load Percentage
Efficiency ≥ % 95
Cooling Fan backup
Bypass switch Standard
Dimensions (W x D x H) (mm) 450 x 350 x 300 560 x 380 x 300 600 x 440 x 320 550 x 550 x 770 600 x 600 x 780
PHYSICAL
SPECIFICATION Degree of protection IP20
Color RAL9005
ELEN reserves the right, at its sole discretion, to change, amend and modify the information given above without prior notice.
R3 Series 30 - 800kVA - Three Phase
SERVO VOLTAGE STABILIZER
Microprocessor Control
User Friendly
High Safety
TECHNOLOGY
High efficiency
Steady operation
Maximum sensibility
RELIABLE
Automatic Activation
Overload protection
USER FRIENDLY
Reduced weight/volume/footprint
Multilanguage option
Fan backup
STANDARDS
TECHNICAL SPECIFICATIONS
POWER (kVA)
VOLTAGE
Frequency 50 / 60 Hz
Output Voltage 380/400/415V (Phase-Phase)
Output Voltage tolerances Adjustable between ±%1 and ±%5
Regulation Speed (V/sn) 80 40
≤ %110 30 min.
OVERLOAD
≤ %130 10 min.
CAPATICY
≤ %150 1 min.
Overload
Protection
General Failure
Output Protection Contactor Standard
Control Microprocessor
Graphic LCD Panel Standard
Input
Output
Indicators with light
GENERAL Overload
General Failure
True RMS Input Voltage
True RMS Output Voltage
Measurements True RMS Output Current
Frequency
Load Percentage
Efficiency ≥ % 97
Cooling Fan backup
Bypass switch Standard
Depth (mm)
PHYSICAL
SPECIFICATION Height (mm)
Degree of protection IP20
Color RAL9005
LIFE TIME 10 Years
ELEN reserves the right, at its sole discretion, to change, amend and modify the information given above without prior notice.
SR1 Series 6 - 30kVA - Single Phase
STATIC VOLTAGE STABILIZER
Microprocessor Control
Thyristor Controlled Technology
High Reliability
TECHNOLOGY
High Efficiency
Steady Operation
Maximum Sensibility
RELIABLE
Automatic activation
Overload protection
USER FRIENDLY
Reduced weight/volume/footprint
Multilanguage option
Fan redundancy
STANDARDS
POWER (kVA) 6 10 15 20 30
VOLTAGE
Frequency 50 / 60 Hz
Output Voltage 220V
Output Voltage Tolerances Between ±2% and ±5%
Regulation Speed (V/sec) 500
%110 30 min.
OVERLOAD
%125 10 min.
CAPATICY
%150 1 min.
Overload
Protection
General Failure
Output Protection Contactor Standard
Control Microprocessor
Graphic LCD Panel Standard
Input
Output
Indicators With Light Input
GENERAL Overload
General Failure
True RMS Input Voltage
True RMS Output Voltage
Measurements True RMS Output Current
Frequency
Load Percentage
Efficiency ≥ %96
Cooling Fan redundancy
Bypass Switch Standard
Microprocessor Control
Thyristor Controlled Technology
High Reliability
TECHNOLOGY
High Efficiency
Steady Operation
Maximum Sensibility
RELIABLE
Automatic activation
Overload protection
USER FRIENDLY
Reduced weight/volume/footprint
Multilanguage option
Fan redundancy
STANDARDS
TECHNICAL SPECIFICATIONS
POWER (kVA)
VOLTAGE
Frequency 50 / 60 Hz
Output Voltage 380/400/415V (Phase to Phase)
Output Voltage Tolerances Between ±2% and ±5%
Regulation Speed (V/sec) 500
%110 30 min.
OVERLOAD
%125 10 min.
CAPATICY
%150 1 min.
Overload
Protection
General Failure
Output Protection Contactor Standard
Control Microprocessor
Graphic LCD Panel Standard
Input
Output
Indicators With Light
GENERAL Overload
General Failure
True RMS Input Voltage
True RMS Output Voltage
Measurements True RMS Output Current
Frequency
Load Percentage
Efficiency ≥ % 97
Cooling Fan redundancy
Bypass Switch Standard
Microprocessor Control
User Friendly
High Reliability
TECHNOLOGY
High Efficiency
With 3 / 4 pole
Steady Operation
Maximum Sensibility
RELIABLE
Automatic activation
Adjustable transfer
USER FRIENDLY
Reduced weight/volume/footprint
Multilanguage option
Fan redundancy
STANDARDS
EN 62310-1 (Safety)
EN 62310-2 (EMC)
TECHNICAL SPECIFICATIONS
%110 60 min.
%130 10 min.
Safety EN 62310-1
STANDARDS
EMC EN 62310-2
ELEN reserves the right, at its sole discretion, to change, amend and modify the information given above without prior notice.
Accessories
SNMP
UASNMP007-1
REMOTE PANEL
Remote panels are designed to monitoring remotely ups
informations like operation mode, voltage, current etc.
UAR001
PARALLELING KIT
A parallel system may be designed by connecting outputs of multiple uninterruptible power supplies to a common load switch.
A parallel system will safely supply loads that are overly sensitive against electric power outages. In a parallel system, when any of
UPSs malfunction and become offline, other UPSs continue to supply the load, thereby preventing any interruption with supply to load.
UAA006-1 C10-40 KVA
UAA006-2 C60-120 KVA, D160 kVA
UAA006-3 D200-300 KVA
UAA006-4 D400-800 KVA
COLD START
When there is no utility power and the UPS is off, the cold start feature will switch the UPS and connected equipment onto battery power.
Accessories
ISOLATION TRANSFORMERS
Isolation transformers are used for safety in high sensitive applications.
UAT3-C030X C 30 kVA UPS UAT3-D250X D 250 kVA UPS
UAT3-C040X C 40 kVA UPS UAT3-D300X D 300 kVA UPS
UAT3-C060X C 60 kVA UPS UAT3-D400X D 400 kVA UPS
UAT3-C080X C 80 kVA UPS UAT3-D500X D 500 kVA UPS
UAT3-C100X C 100 kVA UPS UAT3-D600X D 600 kVA UPS
UAT3-C120X C 120 kVA UPS UAT3-D700X D 700 kVA UPS
UAT3-D160X D 160 kVA UPS UAT3-D800X D 800 kVA UPS
UAT3-D200X D 200 kVA UPS
DUAL INPUT
Dual input option is used to supply the UPS from two different utility. Second input may be different utility company,
different power transformer, different UPS output etc.