Designing Chemical-Injectios Systems PDF
Engineering Practice
Designing Chemical-
Injection Systems 1. 2. 3.
Mohammad Toghraei
Vista Projects
4.
Follow these guidelines
to properly introduce Chemical
Transfering
Flow
Injection
preparation metering
various additives into
process streams FIGURE 1. Careful attention to each of these steps will help to ensure predictable
performance from any chemical-injection system
hroughout the chemical process maximum effort should be made to • Will the presence of the chemical be
rates are chosen in a way that ensures batch operations or a vessel-in-vessel of instantaneous, very-low pressure
the injection system covers all of the system with continuous overflow. at the injection point could cause an
possible operating scenaros. 4. Choosing the appropriate injec- unknown flowrate at the destination.
Qmax is considered to be 1.5 to 2 tion system. The injection pump ca- The use of a back-pressure regulator
times the normal flowrate. From the pacity is usually calculated by multi- is especially critical if the discharge
other side, chemical-injection systems plying Qmax by the maximum dosage. pipe has a backward U shape in its
are one of the few process systems The idea is to choose a system that can route to the destination point (for ex-
that are expected to be fully accurate inject the chemical at a specific flow- ample, if the injection pipe goes over
even during the startup. Because of rate with sufficient accuracy across the pipe rack).
this, Qmin is usually taken as 25% of a wide range of potential destination To satisfy the required precision of
the normal flowrate. flowrates. This means that the injec- the system, the injection pump should
When there is more than one usage tion system should have enough pre- be able to accommodate almost every
for a given chemical in a plant, there is cision and good accuracy. A good in- flowrate below its capacity. For ex-
always the chance of offloading to the jecting pump can satisfy the precision ample, if the design capacity of an
wrong tank, or connecting the wrong requirements, while an appropriate injection pump is 1,000 L/h, it can
chemical tote tank to the injection control system guarantees quick pac- be expected that this pump can pro-
system. This can be prevented by the ing of the destination flow, which dic- vide an accurate flowrate from 1,000
use of suitable signage or by using tates the accuracy of the system. L/h down to possibly 10 L/h. This can
purposefully incompatible hardware Usually, injection systems possess a be done by adding a variable-speed
that can prevent any unintended capacity of less than 5 m3/h (but some- device (VSD) to the electric motor of
chemical flow. times up to 10 m3/h). The required ac- the pump or stroke-adjustment sys-
3. Correct preparation. In most curacy is usually better than 1–2%. tem. The stroke-adjustment system
cases, chemicals are transported to The only process parameter that a can be operated either manually or
the process plant in a concentrated so- chemical injection system needs to via a servo-mechanism. Variable-
lution or powder form. Therefore, the monitor and follow accurately is the frequency devices (VFDs) are one
most popular chemical-preparation flowrate of the injected stream. To sat- popular type of VSD.
system involves a dilution system. isfy the required precision, a positive- To satisfy the accuracy requirements
Two issues should be considered in displacement pump (PD) is often used. of the chemical-injection system, users
this regard: the first is whether the PD pumps with high accuracy are need to make sure that the injection
viscosity of a chemical is suitable for called metering or dosing pumps. The system follows the process flowrate
the selected pump, and the second is most popular types of dosing pumps over its entire turndown ratio very
whether the diluted chemical has ex- are piston, plunger and diaphragm quickly. To ensure such swift respon-
perienced enough aging time. pumps. A gravity-flow pump or cen- siveness, the injection system needs a
The issue of sufficient aging, for trifugal pump usually cannot meet the good control system. A combined feed-
both dilution and solution formation, required accuracy for chemical-injec- back/feedforward control system is the
is generally applicable to polymer- tion systems. ideal choice for complicated cases such
based chemicals. Polymers (with their When setting up injection piping, as acid-injection situations. The feed-
chain of atoms) are usually “cramped” a dedicated pipe should be used for forward portion of the control system
in concentrated form. To be most effec- each injection pump. Using a shared is a ratio control system that forces the
tive, a chemical polymer must be in its injection pump for more than one in- chemical flowrate to follow the desti-
“un-cramped” molecular form. jection point is not a good practice, as nation flowrate. The feedback portion
Thus, a specific amount of time it may result in variable flowrates of is a control loop that is governed by a
should be given for the diluted polymer different chemical streams to differ- property in the resultant stream. The
to settle slowly into its un-cramped ent destinations. This goes against control system can order the VFD or
form. Severe agitation cannot acceler- the main objective of an injection sys- automatic stroke-adjustment mecha-
ate this process, and may be detrimen- tem, which is to deliver specific (and nism (or both in a split-range control
tal for polymers, especially those with accurate) flowrates at the desired system).
long chains (such as flocculants). This injection point. For less complicated cases, a simple
goes against the general practice that When using PD pumps, it is critical feedback control would be sufficient.
usually involves severe mixing for to use a pressure safety valve (PSV) at For the purpose of pump sizing, the
better chemical mixing. Therefore, the the discharge side of the pump. Usually decision on the capacity of the dosing
mixing of polymeric chemicals should a back-pressure regulator is placed at pump is critical. To make sure that
be done more gently, with the impel- the discharge side of the pump to en- the dosing pump can handle all the
ler tip speed limited to avoid polymer sure that the injection system delivers situations, Qmax times maximum
chain breakage. an accurate specified flowrate in all dosage is typically used to define the
When there is a need for two-stage cases, even when there is fluctuation most appropriate capacity for the
dilution (that is, aging, followed by di- in destination pressure. dosing pump.
lution), the system could be designed If the system does not have a back- 5. Determining the right dosage.
as a two-container system, using pressure regulator, the occurrence The reported dosage of a specific chem-
50 CHEMICAL ENGINEERING WWW.CHE.COM NOVEMBER 2012
TABLE 2. PARAMETERS INVOLVED
IN CHEMICAL-STORAGE CALCULATIONS
Engineering Practice Interruptible Non-
interruptible
A Minimum stock to be maintained, days 30 10
B Allowance to compensate delivery 2t 1.5t
ical to be added to a process stream is duration (t), days
usually a range, but the exact dosage C Allowance to make sure the shipment Maximum shipment size
required for a given process stream can be off-loaded completely
is a site-specific number. In many Source: Hudson, Jr., Herbert E., “Water Clarification Processes, Practical Design and Evaluation,”
cases, the right dosage is determined Van Nostrand Reinhold Co., 1981, p. 250.
by some kind of simulation (such as Notes: Interruptible chemicals are those without which there could be an interruption in plant
operations; Non-interruptible chemicals are those that are less critical, so their absence does not
a jar test) carried out in the labora- necessarily interrupt plant operation or product quality.
tory. However, if this measured dosage
happens to be outside of the published of residual chemicals in the system, than a flowmeter to avoid any inaccu-
range, it should be taken cautiously. while underfeeding reduces the ef- racy. In the verification process using
For example, if this dosage is bigger ficacy of the additive. In some cases, the manual method, the volume of the
than the highest end of the range, it both the overfeeding and underfeed- injected chemical is measured at a
could indicate that the chemical may ing of the additive make the injection specific time. By having these two pa-
not be suitable for that application. ineffective (this is the case for the in- rameters, volume and time, the flow-
If the measured dosage is below the jection of coagulants). rate can be calculated.
lowest range of the industry- accepted 6. Verifying the injection dosage. 7. Determining the injection point.
range, then possibly its high effective- The most popular way to verify the Generally speaking, by injecting a
ness is already reflected in its price. amount of injection is to use a draw- chemical two things happen: The
If this chemical is not more expensive down calibration column. In addition chemical will be mixed with the des-
than others, the case should be exam- to all provisions to make sure the tination fluid, and the chemical can
ined. right dosage is injected to the system, be reacted with the destination fluid.
Overfeeding and underfeeding the system also needs to verify the All injected chemicals need mixing to
should be avoided, if possible. As a injection flowrate using an accurate blend them with the process stream,
general statement, overfeeding cre- method. The verification method usu- but not all of them will undergo re-
ates waste and worsens the impact ally uses a manual procedure rather actions with that stream. In reality,
Circle 1 on p. 60 or go to adlinks.che.com/40273-01
52 CHEMICAL ENGINEERING WWW.CHE.COM NOVEMBER 2012
both of these phenomena start to chemical to the main stream from the ing within 100 pipe diameters. In such
happen at the same time. To be ef- body of the main pipe. Of the two jet cases, a multiple orifice diffuser is
fective, a chemical should be injected mixing methods, side-entry jet mixing used instead of quill. As a rough rule
far enough from the point of interest is not very popular in chemical injec- of thumb, for destination pipes with
to make sure the mixing and reac- tion systems, because it is only suit- diameters larger than 22 in., multiple
tion can both go to completion. When able when two streams (the injected orifice diffusers should be used. n
there are multiple injection locations additive and the main stream), have Edited by Suzanne Shelley
and the chemicals are reactive to each roughly the same flowrate, density,
other, they should be separated by at and viscosity. However, these condi- Author
Mohammad Toghraei, M.Sc.
least 3–5 min to ensure they have tions are not common for the majority P.Eng., is a senior process
enough time to react with the desti- of chemical injection systems. engineer with Vista Projects
(330-4000 4th St. SE, Cal-
nation flow and not with each other. Coaxial jet mixing is often called gary, Alberta, Canada T2G
8. Choosing the appropriate injec- “injection by quills.” If the viscosity of 2W3; Phone: 403-255-3455;
Fax: 403-258-2192; Email:
tion tool. An injected chemical may the chemical is below 50 cP, the use mohammad.toghraei@
experience either mixing or reaction, of injection quills might be sufficient vistaprojects.com), and an in-
structor of several process en-
or both, in the process stream with- to ensure good mixing. However, for gineering courses with Prog-
ress Seminars Inc. (http://
out any extra provision in the sys- higher-viscosity chemicals, a static www.progress-seminars.com). Toghraei has more
tem. However, it can be challenging mixer might be needed downstream than 20 years of experience in the field of indus-
trial water treatment, with a focus on the treat-
to achieve good mixing. The primary of the injection quill. If injection is ment of wastewater from oil and petrochemical
form of mixing injected chemicals carried out using quills, but there is complexes. For the past nine years, he has taken
on different technical and leadership roles in
with the main stream is via jet mix- no static mixer in use, then a mixing water treatment areas of steam-assisted grav-
ing — either coaxial jet mixing or length of less than 100 times the desti- ity drainage (SAGD) projects. He holds a B.Sc. in
chemical engineering from Isfahan University of
side-entry jet mixing — in the pipe. nation pipe diameter is expected. Technology, and an M.Sc. in environmental engi-
neering from the University of Tehran, and is a
Side-entry jet mixing uses a T-shape For large pipe sizes, a simple injec- member of the Assn. of Professional Engineers
fitting, which brings the injected tion quill cannot guarantee good mix- and Geoscientists of Alberta (APEGA).
Circle 18 on p. 60 or go to adlinks.che.com/40273-18