ENG 7704
W
H 2 3
Design of Steel Structures
Tamer Sabrah
Ph.D Candidate of Civil Engineering 1 fixed 4 hinged
6.0 m
Uniform Service Level Load, w
Dead Load = 1.50 kN/m’
Session 2 - 2007
Live Load = 2.50 kN/m’
Concentrated Service Level Wind Load,
1 H Æ 10.0 kN acting towards the right at Joint 2 2
3 4
The STAAD Graphical Environment will be invoked and the following screen
will appear:
5 6
1
2. BUILDING MODEL (STRUCTURE) GEOMETRY
1. ENTERING JOB INFORMATION.
How to Define the Frame Geometry?
You MUST put a job name here 1. Create nodes at certain coordinates and then connect
in between these nodes.
2. Use Construction lines
3. Draw it AutoCAD and Import as “.dxf ” file.
4. Using the Staad editor
5. Combination of all the above.
To the more
complicated
7 8
9 10
Load: W 410 X 39
In which we can define the applied loads, load cases,
load combinations.
Material
In which we can define the material properties.
(ex. E, density, etc.)
11 12
2
Assigning the sections created to the model Supports
13 14
15 16
You may change the member orientation by Right Click on the member, 4. DEFINING LOADS
Select Properties
Change in the Geometry Angle Beta
17 18
3
For example: Live Load Case can be Load Case No. 2, and Wind Load is the load case No. 3
Dead Load Case can be Load Case No. 1
19 20
21 22
23 24
4
Live Load Uniform load = - 2.5 kN/m Wind Load Nodal (concentrated) load = 10 kN/m
25 26
27 28
5
To add the pre-print commands click After assigning the command to the members; the members should be highlighted
Pre-Print
as shown and the correct green mark must be beside the command
Define Commands
31 32
35 36
6
STAAD performs Analysis and Design simultaneously.
In order to perform Analysis and Design, select the Run Analysis
option from the Analyze menu.
STAAD Analysis engine is suitable for this tutorial. Click on the Run Analysis button.
37 38
Visualization of Results
The solving process is shown in a pop-up screen!
Note:
As shown in Tutorial 1 :
Generally, in any
You can use the icons shown above to see the
program, try to make
straining actions (BMD, SFD, NFD, Deflections) some checks about the
shapes of deflections,
BMD, SFD. Also check
the level of reactions.
Just to make sure that
there is no significant
input error.
39 40
When you make right click on any member and then click Properties
OR > Viewing the Output File
you will find the properties window as shown
During the analysis process, STAAD creates an Output file.
This file provides important information on whether the analysis
was performed properly.
For example, if STAAD.Pro encounters an instability problem during
the analysis process, it will be reported in the output file.
Alternatively, we can select the File | View | Output File | STAAD Output
option from the top menu.
41 42
7
Shear / Bending moment diagrams and values for each load case and at different Deflection diagrams and values for each load case and at different
sections of the Beam. sections of the Beam.
43 44
Strut
4.5
m
1 fixed 4
6.0 m
If we had some members are link members, which only take the axial forces ---
Make Moment release to the members ends, this is done from the Member
Specification Definition
45 46
Member Specification
From the Specification Menu
Select Beam
47 Add moment release command for the Start and the End of the member 48
8
Assign the Release commands to the Link Member
Repeat Analysis
Questions ?
Thanks