The products in ‘‘ENTES Power Quality and Energy” group are designed to measure various
electrical parameters. With their communication features all measurements can be tracked
from a single monitoring center. Energy quality and efficiency analysis can be performed with
network analyzers in electrical distribution/transmission systems, such as industrial facilities
and buildings.
Network Analyzers
MPR-3X Series
MPR-4X Series
MPR-6X Series
MPR-5X Series
EPM-07 Series
NEW
us
Outage Records
Operating Hour
Dimensions / mm
Digital Output
I neutral
Pulse Output
Digital Input
Event Logs
Pcs/Box
RS-485
THD-V
(RTC)
THD-I
Alarm
Meter
Product Code
MPR-32 72x72 24
MPR-34-11 72x72 1 1 24
MPR-34S-11 72x72 1 1 24
MPR-34-20 72x72 2 24
MPR-34S-20 72x72 2 24
8
Print Date: 03.2014
Power Quality and Energy
Network Analyzers (LCD)
MPR-3X Series
MEASURED PARAMETERS
Phase - Neutral Voltages (VLN) Neutral Currents (In) Active Power (P)
Phase - Phase Voltages (VLL) Total Current (I) Reactive Power (Q)
MPR-32
77
50
72
68
72
TYPE PR25
MPR-3X Series (3 Phase without neutral Aron connection) MPR-3X Series (3 Phase connection in balanced networks) Aux Suply
V1 V2 V3 N 230 Va.c.
1 2
OUT IN RS485
- + - + + - NC
I1 l2 l3
3 S1 S2 S1 S2 S1 S2
4
9
Print Date: 03.2014
Power Quality and Energy
Network Analyzers (LCD)
MPR-3X Series
SPECIFICATIONS
MPR-32 MPR-34-11 MPR-34S-11 MPR-34-20 MPR-34S-20
ENCLOSURE
Dimensions 72x72x50 mm
Display LCD, with backlight
MEASUREMENTS
Voltage
Measurement Range 10-300 VAC (L-N),10-500 VAC (L-L)
Measurement Range with Transformer 10-999 kV
Voltage Accuracy 0,5% ± 1 digit
Input Impedance 1,8 MΩ
Burden (Input Load) <0,5 VA
Current
Current Accuracy 0,5% ± 1 digit
Nominal Current 1A,5A
Measurement Minimum Current 5mA
Measurement Range 50mA-5A 0,5% +- 1 digit
Measurement with Transformer 50mA-10kA
Burden (Input Load) <1 VA
Overload Current 1,2 In
Power/Energy
Active Power Accuracy 0.5% ± 1 digit
Reactive Power Accuracy 1(s)% ± 1 digit
Active Energy Accuracy Class 1
Reactive Energy Accuracy Class 2
Active Power Range 0-1 GW
Reactive Power Range 0-1 GVAr
Apparent Power Range 0-1 GVA
Active Energy Indicating Range 9 999 999,9 kwh
Reactive Energy Indicating Range 9 999 999,9 kVArh
SUPPLY
Supply Voltage 185-315 VAC
Supply Frequency 45-65 Hz
Power Consumption <4 VA
INPUT/OUTPUT STRUCTURE
Digital Input Pulse Width - 20/500 ms
Digital Input Operating Voltage - 12...48 VAC/DC
Switching Current - Max. 50mA
Switching Voltage - Max. 30 VDC
Pulse Width - 20-500 ms (Adjustable)
AMBIENT CONDITIONS
Operating Temperature -10 / +550C
0
Storage Temperature -20 / +70 C
Ambient Humidity 95%
STANDARDS
Applied Standards IEC 61326-1,61010,62053,61557-12
CONNECTIONS
Mounting Front Panel Mounting
Connection Terminals Screw terminal with socket
Connection Types 3 phase neutral, 3 phase, 3 phase (Aron)
COMMUNICATION
Communication RS-485/ RS-485/
- - MODBUS RTU - MODBUS RTU
Interface/Protocol
Transfer Speed - - 1200 - 115200 bps - 1200 - 115200 bps
10
Print Date: 03.2014
Power Quality and Energy
Network Analyzers (LCD)
MPR-4X Series
NEW
MPR-4X Series New-Generation Network Analyzers
With their compact design and 45mm depth, MPR-4X series new
generation network analyzers occupy less space in the panels and
have a wide range of operating voltage (45-265 VAC/DC). In
addition up to 8 MB internal memory, they offer wide I/O solutions with
their replaceable modular structure based on customer requirements
and areas of application.
MPR-4X Series offer a wide range of analog and digital inputs/outputs
and relay outputs with their I/O modules.
us
Operating Hours
Real Time Clock
Outage Records
Harmonics 1-51st
Max., Min. Cos,
Voltage/Current
Dimensions / mm
Pulse Counter
Digital Output
I neutral
Relay Output
Pulse Output
Unbalances
Digital Input
Event Logs
AI mA/V
Memory
RS-485
AO mA
THD-V
THD-I
Alarm
Meter
Product Code AO V
96x96
MPR-45 * * * * * * * * *
96x96 8MB
MPR-45S * * * * * * *
MPR-46 96x96
* * * * * * * * * *
MPR-46S 96x96
* * * * * * * 8MB
*
96x96 8MB
MPR-47S * * * * * * * *
Modular structure Standard
11
Print Date: 03.2014
Power Quality and Energy
Network Analyzers (LCD)
MPR-4X Series
MEASURED PARAMETERS
Active Energy Import
Phase - Neutral Voltages (VLN) Neutral Currents (In) Active Power (P)
(kWh or Mwh)
Active Energy Export
Phase - Phase Voltages (VLL) Total Current (I) Reactive Power (Q)
(kWh or MWh)
Reactive Energy Capacitive
Average Phase-Neutral Voltage Power Factor (P.F) Apparent Power (S)
(kVArh or MVArh)
Reactive Energy Inductive
Average Phase-Phase Voltage Cos Total Active Power (P)
(kVArh or MVArh)
Max. Demand Frequency (Hz) Total Reactive Power (Q) Voltage/Current Unbalances
Phase Currents (IL) Max. / Min. Values Total Apparent Power (S)
MPR-45 / MPR-45S
MPR-46 / MPR-46S
MPR-47S
63
46
Current Measurement Power
Suply Power
AkımMeasurement
Current Ölçümü Suply
99
96
Modül
l1 l2 l3 l4
k1 l1 k2 l2 k3 l3 k4 l4 Power Suply
MPR-4X Series (3 Phase without neutral Aron connection) MPR-4X/7X Series (3 Phase neutral connection)
Current Measurement
Modules
L1 L2 L3 L4 N GND B A TR
V1 V2 V3 V4 N GND A B TR
12
Print Date: 03.2014
Power Quality and Energy
Network Analyzers (LCD)
MPR-4X Series
SPECIFICATIONS
MPR-45 MPR-45S MPR-46 MPR-46S MPR-47S
ENCLOSURE
Dimensions 96x96x45mm
Protection Class Terminals = IP20, Enclosure Protection Class = IP51
Display LCD, with backlight
MEASUREMENTS
VOLTAGE
Measurement Range 5 - 690 VAC (L-N) 5-400 VAC (L-L)
Measurement Range with Transformer 1-400.0kV Transformer Ratio: 1-5000
Accuracy 1
Input Impedance >1M Ω
Burden (Input Load) <0,5 VA
CURRENT
Nominal Current In : 5A / 1A
Minimum Current 5 mA
Measurement Range 50 mA - 6 A Accuracy: 0.5% ± 1 Digit
Measurement Range with Transformer 50 mA -10000 A
Burden 0,5 VA
Overload Current 1,2 In continuous
Short Time Overload (1s) 10xIn
POWER/ENERGY
Active Power Range: 0 - 1 GW,Accuracy: 0.5% ± 1 Digit
Reactive Power Range: 0 - 1 GVAr,Accuracy: 1% ± 1 Digit
Apparent Power Range: 0 - 1 GVA, Accuracy: 1% ± 1 Digit
Power Factor Range: ±1.00, Accuracy : ± 0,02
Active Energy Range: 0 - 99 999 999 kWh or MWh, Accuracy: 1% 1 class
Reactive Energy Range: 0 - 99 999 999 kVArh or MVArh, Accuracy : 2% class 2
Demand Period 1,2,5,10,15,20,30,60 minimum adjustable
Frequency 45-65 Hz
SUPPLY
45 - 265 VAC/DC
50/60 Hz
<5 VA
PULSE OUTPUT
Energy Pulse Output * Active Energy Output (1kVArh/pulse
(1kWh/pulse - 50MWh/pulse)
*Reactive Energy Output - 50MVArh/pulse)
* Max. 50 mA
* 1005..24 VDC
…2500 ms
Pulse Width
* Max. 30 VDC
MEMORY
*
Internal Memory Size - 8MB - 8MB
COMMUNICATION
Communication Interface/Protocol - RS-485 / MODBUS RTU - RS-485 / MODBUS RTU
Transfer Speed - 2400-115200 bps - 2400-115200 bps
AMBIENT CONDITIONS
0
Operating Temperature - 5 / +55 C
0
Storage Temperature - 25 / +70 C
Overvoltage Category III
Pollution Degree II
Ambient Humidity 90%
STANDARDS
Applied Security Standards EN 61557-12, EN 61326-1, EN 61000-6-2, EN 61000-6-3, EN 61000-6-4
EN 62053, EN 60068, EN 61010
CONNECTIONS
Mounting front panel mounting with Rear terminals
Connection Terminals screw terminal with socket
Connection Types 3 phase neutral, 3 phase, 3 phase (Aron)
13
Print Date: 03.2014
Power Quality and Energy
us
0/4-20mA Analog
RS-485 Comm.
0/2-10V Analog
Neutral Current
Alarm Contact
THD-I, THD-V
LCD Display
Digital Input
Pcs/Box
Memory
Output
Output
Product Code
MPR-50 8
MPR-52S-10 8
MPR-60S 8
MPR-60S-10 8
MPR-60S-20 8
MPR-60S-21 8
MPR-60S-40 8
MPR-60S-41 8
MPR-63 8
MPR-63-10 8
MPR-63-20 8
MPR-63-21 8
MPR-63-40 8
MPR-63-41 8
MPR-63-42 2 8
14
Print Date: 03.2014
Power Quality and Energy
Network Analyzers
MPR-50 / MPR-52S / MPR-60S / MPR-63
MEASURED PARAMETERS
Active Energy Import
Phase - Neutral Voltages (VLN) Neutral Currents (In) Active Power (P)
(kWh veya Mwh)
Active Energy Export
Phase - Phase Voltages (VLL) Total Current (I) Reactive Power (Q)
(kWh veya MWh)
Inductive Reactive Energy
Average Phase-Neutral Voltage Power Factor (P.F) Apparent Power (S) (kVArh veya MVArh)
Capacitive Reactive Energy
Average Phase-Phase Voltage Cos Total Active Power (P)
(kVArh veya MVArh)
Phase Currents (IL) Max. / Min. Values Total Apparent Power (S)
MPR-50
MPR-52S / MPR-60S
MPR-63
Internet/
Intranet/VPN GSM Network
RS-485 RS-485
EMG-12 GEM-10
15
Print Date: 03.2014
Power Quality and Energy
Network Analyzers
MPR-50 / MPR-52S / MPR-60S / MPR-63
85 - 265 VAC/DC
50/60 Hz
INPUT/OUTPUT/STRUCTURE
Digital Input - 2 2 (MPR60S-10/20/40) 2 (MPR63-10/20/40/42)
Digital Output - - 2 (MPR60S-21/41) 2 (MPR63-21/41)
PULSE OUTPUT
- Max. 50 mA
- 5..24 VDC
- 100 …2500 ms
- Max. 30 VDC
MEMORY
Data Record - Selectable 28 parameters with time stamp (15000 record)
Memory Size - 1MB
COMMUNICATION
Communication Interface/Protocol - RS-485 / MODBUS RTU
Transfer Speed - 1200 - 38400 bps
AMBIENT CONDITIONS
- 5 / +550C
- 25 / +700C
III
II
90%
STANDARDS
Applied Security Standards EN-61010-1
Applied EMC Standards EN-61000-6-2, EN-61000-6-4
Applied Mechanical Endurance
EN 60529
Standards
CONNECTIONS
front panel mounting
screw terminal with socket
3 phase neutral (3P4W); 3 phase (3P3W); 3 phase (Aron)
16
Print Date: 03.2014
Power Quality and Energy
Network Analyzers
MPR-50 / MPR-52S / MPR-60S / MPR-63
MPR63-42
k l K L k l K L
L3 L3
k l N
k l
N
1 2 3 4 5 6 1 2 3 4 5 6
L1 L2 L3 L1 L2 L3
Current Measurement Inputs Current Measurement Input
Analog Analog
Output RS-485 Output RS-485
7 8 9 10 11 12 13 14 15 16 7 8 9 10 11 12 13 14 15 16
L1 L2 L3 N L1 L2 L3 N
GND A B TR GND A B TR
1. Relay 1 2. Relay 2 3. Input 1 4. Input 2 External 1. Relay 1 2. Relay 2 3. PulseA 4. PulseR External
Supply Supply
17 18 19 20 21 22 23 24 25 26 17 18 19 20 21 22 23 24 25 26
1A
1A
Dimensions
3 Phase without neutral Aron connection
K L
L1
L2 k l 91
K L
L3
k l
82
N
1 2 3 4 5 6
L1 L2 L3
Current Measurement Inputs
96
64
Analog
Output RS-485
7 8 9 10 11 12 13 14 15 16
L1 L2 L3 N
GND A B TR
70
96
1. Relay1 2. Relay2 3. PulseA 4. PulseR External
Supply
17 18 19 20 21 22 23 24 25 26 TYPE PR 19
1A
PulseA PulseR _ L1
+
Max:30VDC N
Connection diagrams are given as references. For the latest connection diagrams, please refer to the user manual or www.entes.com.tr.
17
Print Date: 03.2014
Power Quality and Energy
Network Analyzers
MPR-53 / EPM-07
us
RS-485 Comm.
Neutral Current
Pulse Counter
Alarm Contact
CT-25 (120A)
Digital Input
Pcs/Box
THD-V
THD-I
Product Code
EPM-07-96 12
EPM-07-DIN 12
EPM-07S-96 12
EPM-07S-DIN 12
MPR-53-96 12
MPR-53-DIN 12
MPR-53S-DIN 12
MPR-53CS-DIN 12
MPR-53S-96 12
MPR-53CS-96 12
MPR-53S-DIN-CT25 12
EPM-07S-DIN-CT25 12
18
Print Date: 03.2014
Power Quality and Energy
Network Analyzers
MPR-53 / EPM-07
MEASURED PARAMETERS
Reactive Energy Inductive
Phase - Neutral Currents (VLN) Total Current (I) Apparent Power (S)
(kVArh or MVArh)
Reactive Energy-Capacitive
Phase - Phase Voltages (VLL) Cos Total Active Power (P)
(kVArh or MVArh)
Average Phase-Neutral Voltage Frequency (Hz) Total Reactive Power (Q) Maximum Demand
Average Phase - Phase Voltage Active Power (P) Total Apparent Power (S) Maximum / Minimum Values
Active Energy-Import
Phase Currents (IL) Reactive Power (Q) (kWh or Mwh)
Active Energy-Export
Neutral Current (In)
(kWh or Mwh)
EPM-07 / 07S
MPR-53 / MPR-53S
MPR-53CS
Internet/
Intranet/VPN GSM Network
RS-485 RS-485
EMG-12 GEM-10
19
Print Date: 03.2014
Power Quality and Energy
Network Analyzers
MPR-53 / EPM-07
INPUT/OUTPUT STRUCTURE
Digital Input 2
Digital Input Pulse Width 20ms.
12...48 VAC/DC
NPN transistor
Maximum 50 mA
5..24VDC Maximum 30V DC
100ms pulse period, 80ms pulse width
COMMUNICATION
Communication Interface/Protocol - MODBUS RTU(RS-485) -
Parity - no, odd, even -
Address - 1_247 -
Transfer Speed - 2400-38400 bps -
AMBIENT CONDITIONS
0
-5 / +50 C
III
II
STANDARDS
Applied Security Standards EN 61010-1
Applied EMC Standards EN 61000-6-2, EN 61000-6-4
Applied Mechanical Endurance
EN 60529
Standards
CONNECTIONS
Front Panel Mounting (PR 19) / Rail mounting (PK 26)
screw terminal with socket
3 phase neutral,3 phase, 3 phase (Aron)
20
Print Date: 03.2014
Power Quality and Energy
Network Analyzers
MPR-53 / EPM-07
Relay Output
(PK 26 - DIN6)
MPR-53S (3 Phase Neutral) MPR-53S (3 Phase without Neutral with Aron) Dimensions
91
82
90
96
Auxiliary Auxiliary
Supply Voltage Measurement Current Measurement Current Measurement
Input Supply Voltage Measurement
Input Input Input
70
96
TYPE PR 19
(12-48V DC)
- + - +
45.0
90.0
Auxiliary
Voltage Measurement Current Measurement
Supply
14.0
TYPE DIN / PK 26
Connection diagrams are given as references. For the latest connection diagrams, please refer to the user manual or www.entes.com.tr.
21
Print Date: 03.2014
Power Quality and Energy
us
EPR-04S-DIN-CT25
CT-25
Apparent Power (VA)
R. Energy (kVArh)
RS-485 Comm.
Energy Pulse
Measurement
Digital Input
Dual Energy
Demand
Pcs/Box
Cos
Product Code
W
EPR-04-96 12
EPR-04-DIN 12
EPR-04S-96 12
EPR-04S-DIN 12
EPR-04S-DIN-CT25 12
EPR-04, EPR-04S
ENCLOSURE INPUT/OUTPUT STRUCTURE
Dimensions 96x96mm PR19, DIN6 PK26 Digital Input 2
Protection Class IP40 Front Panel,IP54 Optional Digital Input Pulse Width 20ms
Weight 0,5kg/pcs VAC/DC
Display Red LED; Height 10mm NPN Transistor
MEASUREMENT Maximum 50mA
Voltage 5...24 VDC Maximum 30 VDC
Measurement Range 10-300 VAC (L-N), 10-500 VAC (L-L) 100ms period 80ms width
Measurement Range with Transformer 10-200kV
AMBIENT CONDITIONS
Accuracy 1%±1 digit [(10%-110%)xFull scale]
-5 / +550C
Input Impedance 1.8 MΩ
III
Burden (Input Load)
Current II
Nominal Current Ambient Humidity 90%
5,5A
Minimum Current 50mA STANDARDS
Measurement Range 50mA-5,5A Applied Security Standards EN 61010-1
Measurement Range with Transformer 50mA-10kA Applied EMC Standards EN 61000-4-5, EN 61000-4-4,
Burden EN 61000-4-2, EN 61000-4-11
Over Load Current 1,2 In Applied Mechanical Endurance
Standards EN 60529
Power/Energy
Active Power Range 0-215 MW CONNECTIONS
Reactive Power Range Front Panel Mounting (PR 19) / Rail mounting (PK 26)
Apparent Power Range screw terminal with socket
Active Energy Range 3 phase neutral,3 phase, 3 phase (Aron)
9 999 999,9 Mwh
Reactive Energy Range
ES-32LS:
It communicates over the RS-485 port by storing energy
measurements in the ModBus registers.
ES-32 series have MID certificate which is accepted as a
measurement standard in European countries.
MID (Optional)
RS-485 Comm.
Pcs/Box
Product Code
Optional
Internet/
Intranet/VPN GSM Network
RS-485 RS-485
EMG-12 GEM-10
23
Print Date: 03.2014
Power Quality and Energy
90
IL1
96
IL2 IL3
Max: 30 VDC
( 12-48V DC )
Current Measurement Input
Pul C InC In1 In2 RS485 Max: 30 VDC
_ ( 12-48V DC )
+ 13 14 15 16 17 18 19 20 21 22 Pul C InC In1 In2 RS485
_
GND A B TR + 13 14 15 16 17 18 19 20 21 22
Pul 1 Pul 2 GND A B TR
Pul 1 Pul 2
Auxiliary
Voltage Measuring Input 70
L1 L2 L3 N Supply Voltage Measuring Input Auxiliary
7 8 9 10 11 12 L1 L2 L3 N Supply 96
7 8 9 10 11 12
1A
L1 TYPE PR 19
1A
N L1
N
EPR-04S (3 Phase without Neutral with Aron) EPR-04S (3 Phase without Neutral) 10.8 30.1 7.6 9.5
L1 K L K L
L1 60.6
L2 k l k l K L
L2
L3 K L k l K L
L3
k l k l
45.0
90.0
1 2 3 4 5 6
IL1 IL2 IL3
1 2 3 4 5 6
IL1 IL2 IL3 Current Measurement Input
Current Measurement Input Max: 30 VDC
( 12-48V DC )
Max: 30 VDC _ Pul C InC In1 In2 RS485
14.0
( 12-48V DC ) 13 14 15 16 17 18 19 20 21 22
8.5
+
_ Pul C InC In1 In2 RS485 GND A B TR
13 14 15 16 17 18 19 20 21 22
+
GND A B TR
Pul 1 Pul 2 106.0
Pul 1 Pul 2
Voltage Measuring Input Auxiliary 26.5 21.5 10.0
Auxiliary L1 L2 L3 N Supply
Voltage Measuring Input
L1 L2 L3 N Supply 7 8 9 10 11 12 53.0
58.0
1A
7 8 9 10 11 12
L1
1A
L1 N TYPE DIN / PK 26
N
63 19
49
45
(PK 26 - DIN6)
EPR-04S (3 Phase Neutral) EPR-04S (3 Phase without Neutral with Aron)
35
45
87
+ +
_ _
PUL2L
PUL2H
PUL1L
PUL1H
IN1L
IN1H
IN2L
IN2H
Gnd A B TR Gnd A B TR
RS-485 RS-485
Auxiliary Voltage Measurement Current Measurement Auxiliary Voltage Measurement Current Measurement
Supply Input Input Supply Input Input
Un IL1 IL2 IL3 Un IL1 IL2 IL3
~ L1 L2 L3 N ~ L1 L2 L3 N
1A 1A N
L1
k l
K Lk l
L2 L1 k l
K Lk K L k l
L3 l L2
K L K L
N L3
Connection Diagram
EPR-04S (3 Phase without Neutral) EPR-04S (3 Phase without Neutral with Aron)
Max: 30 VDC Max: 30 VDC
+ +
_
_ N
Nötr çıkış
Nötr giriş
6 6
(12-48V DC) (12-48V DC) SO+ N L SO+
- + - + - + - + SO- SO-
6 4 6 4
PUL2L
PUL2H
PUL1L
PUL1H
IN1L
IN1H
IN2L
IN2H
Nominal 24V DC
Gnd A B TR
PUL2L
PUL2H
PUL1L
PUL1H
IN1L
IN1H
IN2L
IN2H
Auxiliary Voltage Measurement Current Measurement Auxiliary Voltage Measurement Current Measurement
Yük
L2 K L k l
Phase
K Lk
Out
L3 l L2
K L k l
L3 L L
K L
Connection diagrams are given as references. For the latest connection diagrams, please refer to the user manual or www.entes.com.tr.
24
Print Date: 03.2014